SmartClass Fiber OLTS-85P Optical Loss Test Set with Patch Cord Microscope
Handheld Tier 1 optical loss test set with an integrated patch cord microscope for loss, length, polarity and end-face certification.
- Optical interface
- Interchangeable adapter LC/PC, LC/APC
- Detector type
- InGaAs
- Wavelength range/settings
- 800 to 1700 nm/in 1 nm steps
- Calibrated wavelengths
- 850, 980, 1310, 1490, 1550, 1625 nm
Overview
The VIAVI SmartClass Fiber OLTS-85P is a handheld optical loss test set (OLTS) for Tier 1 certification of installed fiber optic links. It combines fiber end-face inspection with loss, length and polarity testing in a single instrument, and is available in dedicated multimode, single-mode and quad versions.
An optical loss test set measures the length and optical loss of a fiber link or channel and checks its polarity. These measurements are required by installation standards such as TIA 568.3, ISO 11801 and ISO/IEC 14763-3 and are referred to as basic or Tier 1 fiber certification. The OLTS-85/85P applies pass/fail limits from these standards and tests two fibers at two wavelengths in one run, with results from both the local and remote unit saved on the local device.
Inspection and reporting
The instrument supports end-face inspection with automated pass/fail analysis on both the local and remote device, and the light sources are encircled-flux compliant. Results are shown on a 3.5-inch color touch screen; fiber certification reports are generated through the FiberChekPRO reporting software, and the SmartClass Fiber, J-Reporter and ReportPRO software packages are available for download. The unit starts instantly from sleep mode and the Li-ion battery pack is rated for a full working day.
Key Features
- Comprehensive Tier 1 fiber testing to TIA/ISO/IEC standards
- Dedicated multimode, single-mode and quad versions
- Fiber end-face inspection with automated pass/fail analysis on both local and remote devices
- Integrated saving of both local and remote results on the local device
- Encircled flux compliant light sources
- Pass/fail results against industry standard limits
- Length and optical loss measured on two fibers at two wavelengths
- Polarity verification
- Instant on from sleep mode
- Easily generated fiber certification reports
- 3.5” color touch screen
- Direct reports via FiberChekPRO reporting software
- All-day battery life
- Integrated patch cord microscope for LC connector inspection
Specifications
| Optical interface |
Interchangeable adapter LC/PC, LC/APC
Optional 2014-style adapters: SC, ST, FC, DIN, E2000 and UPP 2.5 mm and UPP 1.25 mm
|
|---|---|
| Detector type | InGaAs |
| Wavelength range/settings | 800 to 1700 nm/in 1 nm steps |
| Calibrated wavelengths | 850, 980, 1310, 1490, 1550, 1625 nm |
| Power measurement range | –75 to +15 dBm |
| Max. permitted input level | +15 dBm |
| Absolute measurement uncertainty |
±0.15 dB (±3.5%)
Valid for calibrated wavelengths 1310 nm, 1490 nm, 1550 nm at reference conditions, at -22 dBm (CW), 23°C ±3K, 9µm test fiber with SC/PC ceramic connector. Intrinsic uncertainty for 850 nm (at -20 dBm), 980 nm and 1625 nm (at -22 dBm) is ±0.25 dB (±6%)
|
| Overall measurement uncertainty, 850 nm |
±0.35 dB ±0.25 nW
-75 dBm to +26 dBm, -5°C to +45°C
|
| Overall measurement uncertainty, 980 nm |
±0.35 dB ±0.25 nW
-75 dBm to +26 dBm, -5°C to +45°C
|
| Overall measurement uncertainty, 1310 nm |
±0.25 dB ±0.05 nW
-75 dBm to +26 dBm, -5°C to +45°C
|
| Overall measurement uncertainty, 1490 nm |
±0.25 dB ±0.05 nW
-75 dBm to +26 dBm, -5°C to +45°C
|
| Overall measurement uncertainty, 1550 nm |
±0.25 dB ±0.05 nW
-75 dBm to +26 dBm, -5°C to +45°C
|
| Overall measurement uncertainty, 1625 nm |
±0.35 dB ±0.05 nW
-75 dBm to +26 dBm, -5°C to +45°C
|
| Overall measurement uncertainty, 800 nm to 1300 nm |
±0.7 dB ±25 nW
Overall measurement uncertainty for 800 to 1700 nm (non-calibrated wavelengths)
|
| Overall measurement uncertainty, 1300 nm to 1550 nm |
±0.4 dB ±5 nW
Overall measurement uncertainty for 800 to 1700 nm (non-calibrated wavelengths)
|
| Overall measurement uncertainty, >1550 nm |
±0.7 dB ±5 nW
Overall measurement uncertainty for 800 to 1700 nm (non-calibrated wavelengths)
|
| Linearity | 0.1 dB |
| Automatic offset nulling | Yes |
| Measurement units | dB, dBm, Watt |
| Display resolution | 0.01 dB/0.0001 µW |
| Power meter functions | Absolute, relative, pass/fail, Auto λ, Tone detection |
| Warm-up time | None, instant-on |
| Optical interface (multimode) |
Interchangeable adapter FC/PC
Optional 2155-style adapters: SC, ST, and LC
|
|---|---|
| Optical interface (single-mode) |
Interchangeable adapter SC/PC
Optional 2155-style adapters: FC, ST and LC
|
| Source type and wavelengths (multimode) | LED source, 850 nm ± 20 nm, 1300 nm ± 20 nm |
| Source type and wavelengths (single-mode) | Fabry-Perot laser diode, 1310 nm ± 20 nm, 1550 nm ± 20 nm |
| Spectral width (multimode) | 50/170 nm |
| Spectral width (single-mode) | 5/5 nm |
| Launch condition (multimode) |
Encircled Flux compliant to TIA-526-14 and IEC 61280-4-1
At the output of the EF-TRC. Variations between EF measurement equipment may occur but EF compliance can be expected with a 95% confidence factor. Valid for IEC 61280-4-1 at 850 nm
|
| Output power, settable in 0.1 dB steps (multimode) | –22 to –25 dBm |
| Output power, settable in 0.1 dB steps (single-mode) | 0 to –3 dBm |
| Stability (15 min/8 hr) |
±0.02/0.2 dB
At constant temperature, after a 20-minute warm-up
|
| Source modes | CW, tone, auto-λ, multi-λ |
| Tone generator | 270 Hz, 1 kHz, 2 kHz |
| Testing speed, remote mode |
<6 seconds
Two wavelengths, one direction, auto wavelength detection (excludes referencing and connection times)
|
|---|---|
| Testing speed, loopback mode |
≤3 seconds
Two wavelengths, one direction, auto wavelength detection (excludes referencing and connection times)
|
| Pass/fail limit standards | TIA 568.3, ISO 11801 and ISO/IEC 14763-3, link validation |
| Fiber types (multimode) | 50/125 μm or 62.5/125 μm |
| Fiber types (single-mode) | 9/125 µm |
| Nominal test wavelengths (multimode) | 850/1300 nm |
| Nominal test wavelengths (single-mode) | 1310/1550 nm |
| Maximum length measurement (multimode) | 12 km |
| Maximum length measurement (single-mode) | 100 km |
| Length measurement accuracy |
± 1.5 m plus ± 1% of length
For multimode up to 1 km range, for singlemode up to 10 km range
|
| Loss measurement uncertainty |
<0.2 dB
After 20 min warm up, at constant temperature, no charging. Multimode with 50/125 µm fibers (NA = 0.20); single-mode with 9/125 µm fibers (NA = 0.10)
|
| External inspection probe | USB connected P5000i digital inspection probe supported |
|---|
| Display | High-contrast 3.5” color LCD with touch-screen functionality |
|---|---|
| Data memory | Up to 10.000 loss test results (>1000 including inspection) |
| Data readout | Via client USB interface, and wireless via USB WiFi/Bluetooth adapter (option) |
| Electrical interfaces | 2 x USB host, 1x micro USB, Ethernet |
| Power supply | 12 V, 2A with interchangeable wall plug for EU, UK, US, and AU |
| Battery |
Li-ion pack 3.7 V, 20 Wh
Optional 8 NiMH/dry batteries
|
| Battery life (Li-ion battery pack) | >12 hr |
| Recommended recal. interval | 3 years |
| Operating temperature range | –5˚ to +45˚C (23˚ to 113˚F) |
| Storage temperature range | –25˚ to +55˚C (–13° to 131°F) |
| Dimensions (H x W x D) | 208 x 153 x 64 mm (8.2 x 6.0 x 2.5 in) |
| Weight | 850 g (1.85 lb) |
| Optical interface |
FMAX LC duplex
Many other adapters available
|
|---|---|
| Auto pass/fail analysis standards | IEC 61300-3-35 and custom limits |
| Live image | 320 x 240 x 8 bit grey, 10 fps |
| Light source | Blue LED, 100.000+ hours life |
| Lighting technique | Coaxial |
| Magnification field-of-view, horizontal (low/high) | 740/370 µm |
| Magnification field-of-view, vertical (low/high) | 550/275 µm |
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- Tier 1 (basic) fiber optic certification
- Measuring length and optical loss of installed fiber links (two fibers, two wavelengths)
- Ensuring correct polarity
- Inspecting fiber end faces on patch cords and bulkheads
- Troubleshooting of optical links and channels
- Certifying installations to TIA 568.3, ISO 11801 and ISO 14763-3