Anritsu ACCESS Master MT9085 Series handheld OTDR front view with touchscreen
Anritsu / Series · OTDRs

ACCESS Master MT9085 Series Handheld All-in-One OTDR with 8-inch Touchscreen

Handheld all-in-one OTDR with 8-inch touchscreen, built-in light source and power meter, and up to 46 dB dynamic range

Wavelength
1310/1550 nm ±25 nm
Dynamic Range (HR)
46/46 dB
Dynamic Range (ER)
25/25 dB
Dead Zone (Backscatter)
≤3.8/4.3 m
View Models

Overview

The Anritsu ACCESS Master MT9085 series is a compact handheld all-in-one tester for optical pulse tests (OTDR), optical loss and power measurements, and optical fiber end-face inspection. Applications range from installation and maintenance (I&M) of trunk fibers in core, metro, mobile fronthaul and mobile backhaul networks to troubleshooting access networks, such as locating breaks in drop cables.

The series keeps the hard keys and rotary knob of earlier ACCESS Master models and adds an 8-inch color LCD touchscreen. The pressure-sensitive touchscreen accepts input without removing work gloves. Three main units are offered: MT9085A (Standard Dynamic Range), MT9085B (Enhanced Dynamic Range) and MT9085C (High Performance Dynamic Range), each combined with an OTDR module option that sets the wavelengths.

Optical Pulse Test (OTDR)

The OTDR measures fiber transmission loss and length and detects events such as breaks in fiber continuity. Single mode and multimode fibers are supported, with models covering 850, 1300, 1310, 1490, 1550, 1625 and 1650 nm. The Fiber Visualizer function displays events such as splices, connectors and PON splitters as schematic icons with loss and reflectance Pass/Fail results. Two realtime sweep modes (high-speed and high S/N) help locate fiber bends, and PON analysis supports up to 1 × 128 branches.

Optical Power/Loss Measurement

A stabilized light source and a power meter are built in through the OTDR port as standard. Optional dedicated-port power meters enable optical loss test set (OLTS) measurements with one tester, and an optional visual fault locator shows light leaking at fiber breaks.

End-Face Inspection and Data Management

With the external G0306C Video Inspection Probe (sold separately), the instrument displays the connector ferrule end face and performs automatic Pass/Fail evaluation to IEC 61300-3-35. Measurement data can be saved as original files (.sor, .vipi), .csv, screen captures or PDF reports, and transferred via USB memory, USB cable, WLAN or Ethernet (USB adapters required). Remote control is available through a web browser GUI or remote commands.

Models in this series

Model Description
MT9085A-053
ACCESS Master MT9085A-053 Handheld OTDR, 1310/1550 nm Single Mode, Standard Dynamic Range
Handheld all-in-one OTDR with 1310/1550 nm single-mode testing, 39/37.5 dB dynamic range, built-in light source and power meter
Details →
MT9085A-057
ACCESS Master MT9085A-057 1310/1550/1625 nm SMF Handheld OTDR
Standard-class handheld ACCESS Master OTDR with 1310/1550/1625 nm single-mode wavelengths for macrobend analysis and fiber I&M.
Details →
MT9085A-063
ACCESS Master MT9085A-063 Handheld OTDR, 1310/1550 nm SM and 850/1300 nm MM
Standard-dynamic-range handheld all-in-one OTDR for single mode and multimode fiber at 1310/1550 nm and 850/1300 nm with 8-inch touchscreen.
Details →
MT9085B-053
ACCESS Master MT9085B-053 1310/1550 nm SMF Handheld OTDR (Enhanced Dynamic Range)
Handheld all-in-one OTDR with 1310/1550 nm single-mode wavelengths, 42/41 dB dynamic range and an 8-inch touchscreen
Details →
MT9085B-055
ACCESS Master MT9085B-055 Handheld OTDR, 1310/1550/1650 nm SMF with Built-in Filter for Live Circuit Maintenance
Enhanced-model ACCESS Master handheld OTDR with 1310/1550 nm and filtered 1650 nm single-mode wavelengths for in-service fiber maintenance.
Details →
MT9085B-056
ACCESS Master MT9085B-056 1310/1490/1550 nm SMF OTDR for FTTx/PON Installation and Maintenance
Handheld enhanced-range OTDR at 1310/1490/1550 nm for FTTx/PON installation and maintenance, with 42/41/41 dB dynamic range.
Details →
MT9085B-057
ACCESS Master MT9085B-057 Enhanced Dynamic Range OTDR, 1310/1550/1625 nm Single Mode
Handheld all-in-one OTDR with 1310/1550/1625 nm single-mode wavelengths and 40/39/38 dB dynamic range for macrobend analysis.
Details →
MT9085B-058
ACCESS Master MT9085B-058 Handheld OTDR, 1310/1490/1550/1625 nm SM
Enhanced-range ACCESS Master handheld OTDR with 1310/1490/1550/1625 nm single-mode wavelengths for FTTx/PON and CWDM band evaluation.
Details →
MT9085B-063
ACCESS Master MT9085B-063 Enhanced SMF/MMF Handheld OTDR (1310/1550 nm SM, 850/1300 nm MM)
Handheld all-in-one OTDR for single-mode and multimode fiber at 1310/1550 nm SM and 850/1300 nm MM, with 42/41 dB SM dynamic range
Details →
MT9085C-053
ACCESS Master MT9085C-053 High Performance 1310/1550 nm SMF Handheld OTDR
High-performance handheld OTDR with 1310/1550 nm single-mode wavelengths, 46/46 dB dynamic range, built-in light source and power meter.
Details →
MT9085C-057
ACCESS Master MT9085C-057 High Performance 1310/1550/1625 nm Handheld OTDR
High Performance ACCESS Master handheld OTDR with 1310/1550/1625 nm single-mode wavelengths and up to 46 dB dynamic range.
Details →

Key Features

  • 8-inch LCD touchscreen with visibility in direct sunlight
  • Touchscreen, rotary knob and dedicated hard keys for efficient operation
  • Pressure-sensitive touchscreen operable with work gloves
  • Fiber Visualizer function for simple fiber path analysis with Pass/Fail evaluation
  • High-speed and high S/N real-time sweep modes for fast fiber bend location
  • 46 dB dynamic range max. and 0.8 m event dead zone
  • Identification of each splitter event for up to 1 × 128 PON branches
  • Built-in stabilized light source and optical power meter as standard
  • Optional optical power meters, visual fault locator and external fiberscope
  • Optical fiber end-face inspection with Pass/Fail evaluation to IEC 61300-3-35
  • Installation Test function for automatic measurement of multiple fibers
  • Bi-directional measurement and analysis function
  • Live fiber detection and OTDR connection check
  • Cable Certification Test function with PDF report output
  • Scenario Manager Lite for automated testing without a PC
  • Telcordia SR-4731 trace format support
  • 1 GB internal memory for up to 50,000 traces
  • Remote GUI control by web browser and remote commands
  • Password protection function
  • 12-hour battery operation

Specifications

OTDR by Model
Wavelength
MT9085C-053
1310/1550 nm ±25 nm
Dynamic Range (HR)
MT9085C-053
46/46 dB
Typical; subtract 1 dB for guarantee. SNR = 1, averaging 180 sec., 25°C
Dynamic Range (ER)
MT9085C-053
25/25 dB
Pulse width: 100 ns (ER Mode), Distance range: 100 km
Dead Zone (Backscatter)
MT9085C-053
≤3.8/4.3 m
IOR = 1.500000
Wavelength
MT9085C-057
1310/1550/1625 nm ±25 nm
Dynamic Range (HR)
MT9085C-057
46/46/44 dB
Typical; subtract 1 dB for guarantee. SNR = 1, averaging 180 sec., 25°C
Dynamic Range (ER)
MT9085C-057
25/25/23 dB
Pulse width: 100 ns (ER Mode), Distance range: 100 km
Dead Zone (Backscatter)
MT9085C-057
≤3.8/4.3/4.8 m
IOR = 1.500000
Wavelength
MT9085B-053
1310/1550 nm ±25 nm
Dynamic Range
MT9085B-053
42/41 dB
Typical; subtract 1 dB for guarantee. SNR = 1, averaging 180 sec., 25°C
Dead Zone (Backscatter)
MT9085B-053
≤5/5.5 m
IOR = 1.500000
Wavelength
MT9085B-055
1310/1550 nm ±25 nm, 1645 nm to 1655 nm
1650 nm port with built-in filter for in-service live circuits
Dynamic Range
MT9085B-055
42/41/35 dB
Typical; subtract 1 dB for guarantee. At 1650 nm: with background light, 1310/1550 nm, –19 dBm CW light. Product introduction lists 41/41/35 dB
Dead Zone (Backscatter)
MT9085B-055
≤5/5.5/6.5 m
IOR = 1.500000
Wavelength
MT9085B-056
1310/1490/1550 nm ±25 nm
Dynamic Range
MT9085B-056
42/41/41 dB
Typical; subtract 1 dB for guarantee
Dead Zone (Backscatter)
MT9085B-056
≤6/6.5/6.5 m
IOR = 1.500000
Wavelength
MT9085B-057
1310/1550/1625 nm ±25 nm
Dynamic Range
MT9085B-057
40/39/38 dB
Typical; subtract 1 dB for guarantee
Dead Zone (Backscatter)
MT9085B-057
≤6/6.5/7.5 m
IOR = 1.500000
Wavelength
MT9085B-058
1310/1490/1550/1625 nm ±25 nm
Dynamic Range
MT9085B-058
42/41/41/40 dB
Typical; subtract 1 dB for guarantee
Dead Zone (Backscatter)
MT9085B-058
≤7/7.5/7.5/8.5 m
IOR = 1.500000
Wavelength
MT9085B-063
1310/1550 nm ±25 nm, 850/1300 nm ±30 nm
HYBRID (SMF/MMF)
Dynamic Range
MT9085B-063
42/41 dB (SMF), 29/28 dB (MMF)
Typical; subtract 1 dB for guarantee. At 50 μm/125 μm MM fiber the dynamic range drops by about 3.0 dB
Dead Zone (Backscatter)
MT9085B-063
≤5/5.5 m, ≤4/5 m (3/4 m typ.)
IOR = 1.500000
Wavelength
MT9085A-053
1310/1550 nm ±25 nm
Dynamic Range
MT9085A-053
39/37.5 dB
Typical; subtract 1 dB for guarantee
Dead Zone (Backscatter)
MT9085A-053
≤5/5.5 m
IOR = 1.500000
Wavelength
MT9085A-057
1310/1550/1625 nm ±25 nm
Dynamic Range
MT9085A-057
37/35.5/32.5 dB
Typical; subtract 1 dB for guarantee
Dead Zone (Backscatter)
MT9085A-057
≤6/6.5/7.5 m
IOR = 1.500000
Wavelength
MT9085A-063
1310/1550 nm ±25 nm, 850/1300 nm ±30 nm
HYBRID (SMF/MMF)
Dynamic Range
MT9085A-063
39/37.5 dB (SMF), 29/28 dB (MMF)
Typical; subtract 1 dB for guarantee. At 50 μm/125 μm MM fiber the dynamic range drops by about 3.0 dB
Dead Zone (Backscatter)
MT9085A-063
≤5/5.5 m, ≤4/5 m (3/4 m typ.)
IOR = 1.500000
OTDR Common
Fiber Type Single Mode (SMF) 10/125 μm ITU-T G.652
Options 063: HYBRID (SMF/MMF)
Pulse Width (SMF) 3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns
Pulse Width (MMF)
MT9085A-063, MT9085B-063
3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000 ns
850 nm: Does not support 1000, 2000, 4000 ns
Dead Zone (Fresnel) ≤1 m, 0.8 m (typ.)
Pulse width: 3 ns, return loss: 40 dB, 25°C, IOR = 1.500000
Measurement Mode
MT9085C-053, MT9085C-057
HR/ER
HR: High Resolution mode for short dead zone; ER: Enhanced Range mode for PON measurement
Laser Safety IEC 60825-1: 2014 CLASS 1
Complies with 21CFR1040.10 and 1040.11 except for conformance with IEC 60825-1 Ed.3., as described in Laser Notice No. 56
Vertical Scale 0.1, 0.2, 0.5, 1.0, 2.0, 5.0, 10.0 dB/div
IOR Setting 1.300000 to 1.700000 (0.000001 steps)
Units km, m, kft, ft, mi
Sampling Points Up to 150,001
Either high density value is selected depending on distance range
Sampling Resolution 0.05 m to 60 m
Reflectance Accuracy (Single mode) ±2 dB
When measuring the non-connected end of an approximately 25 km length fiber, Distance range: 50 km, Pulse width: 2 μs
Reflectance Accuracy (Multimode) ±4 dB
When measuring the non-connected end of an approximately 4.5 km length fiber, Distance range: 10 km, Pulse width: 100 ns
Distance Accuracy ±1 m ±3 × measurement distance × 10^-5 ± marker resolution
Excluding IOR uncertainty
Loss Measurement Accuracy (Linearity) ±0.05 dB/dB or ±0.1 dB (whichever is greater)
Distance Range (Single mode) 0.5, 1, 2.5, 5, 10, 25, 50, 100, 200, 300 km
Distance Range (Multimode) 0.5, 1, 2.5, 5, 10, 25, 50, 100 km
Event Pass/Fail Threshold (reflective and non-reflective events) 0.01 to 9.99 dB (0.01-dB steps)
User defined
Reflectance Threshold 70.0 to 20.0 dB (0.1-dB steps)
User defined
Fiber End/Break Threshold 1 to 99 dB (1-dB steps)
User defined
Number of Detected Events up to 99
Macrobend detection supported
OTDR Trace Format Telcordia universal. SOR, issue 2 (SR-4731)
Real Time Sweep 0.15 sec.
Resolution: Low Density
Loss Modes 2-point loss, dB/km, 2-point LSA, splice loss, ORL
Averaging Modes Timed (1 to 3600 s)
Other Functions Live Fiber detect, Connection check, Trace overlay and comparison, Template function, USB keyboard support, Remote control, Remote GUI, Password protection feature
Light Source (standard, through OTDR port)
Wavelength Same as OTDR
CW, 25°C
Spectral Width ≤5 nm (1310 nm), ≤10 nm (850/1300/1490/1550/1625 nm), ≤3 nm (1650 nm)
CW, 25°C
Wavelength Accuracy 850/1300/1310/1490/1550/1625 nm: ±30 nm; 1650 nm: ±5 nm
CW, 25°C
Output Power –5 ±1.5 dBm
CW, 25°C
Output Stability ≤0.1 dB
CW, –10°C to 50°C (±1°C) difference between max/min. values over 1 minute, SM fiber 2 m
Modes of Operation CW, 270 Hz, 1 kHz, 2 kHz
Modulation +1.5% with 10 minute warm up
Power Meter (standard, through OTDR port)
Maximum Input +10 dBm
Not available if Option 004, 005 or 007 is ordered
Measurement Range –50 to –5 dBm
Accuracy ±6.5%
CW input, –20 dBm at 1550 nm, 23°C ±2, Anritsu reference single mode fiber with FC/UPC connector
Setting Wavelengths 1310, 1550, 1625, 1650 nm
Options 053, 055, 057, 063
Setting Wavelengths
MT9085B-056, MT9085B-058
1310, 1490, 1550, 1625 nm
Options 056, 058
Features Store reference, loss table
Loss Test Set Power Meter Options
Measurement Range
MT9085A/B/C-007
–67 to +6 dBm (CW, 1310 nm)
Peak power, subtract 3 dB for modulated tones; –60 to +3 dBm @850 nm
Measurement Range
MT9085A/B/C-004
–50 to +23 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones
Measurement Range
MT9085A/B/C-005
–43 to +30 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones
Fiber Type
MT9085A/B/C-007
Single Mode: 10 μm/125 μm (G.652), Multimode: 62.5 μm/125 μm
Fiber Type
MT9085A/B/C-004, MT9085A/B/C-005
Single Mode: 10 μm/125 μm (G.652)
Option 005: PC only for UPC connector
Wavelength Range
MT9085A/B/C-007
800 nm to 1700 nm
Wavelength Range
MT9085A/B/C-004, MT9085A/B/C-005
1200 nm to 1700 nm
Setting Wavelengths
MT9085A/B/C-007
850, 1300, 1310, 1383, 1490, 1550, 1625, 1650 nm
Setting Wavelengths
MT9085A/B/C-004, MT9085A/B/C-005
1310, 1383, 1490, 1550, 1625, 1650 nm
Optical Connector
MT9085A/B/C-007
Universal – uses LP-XX adapters
Optical Connector
MT9085A/B/C-004
Universal – uses JXXXX adapters (same as OTDR)
Optical Connector
MT9085A/B/C-005
Universal – uses MA9005B adapters
Accuracy
MT9085A/B/C-007
±5% (1310 nm/1550 nm), ±0.5 dB (850 nm)
CW, at –10 dBm, 25°C, Anritsu reference SM fiber with FC/UPC connector, after zero offset
Accuracy
MT9085A/B/C-004, MT9085A/B/C-005
±5% (1310 nm/1550 nm)
Option 004: CW at –10 dBm; Option 005: CW at 0 dBm; 25°C, after zero offset
Reflectance
MT9085A/B/C-004
≥36 dB
Using SM fiber (ITU-T G.652)
Modulation
MT9085A/B/C-004, MT9085A/B/C-005, MT9085A/B/C-007
CW, 270 Hz, 1 kHz, 2 kHz
Operating Temperature and Humidity
MT9085A/B/C-004, MT9085A/B/C-005, MT9085A/B/C-007
0°C to +50°C, <80% (non-condensing)
Visual Light Source (Option 002)
Central Wavelength
MT9085A/B/C-002
650 nm±15 nm (at 25˚C)
Optical Output
MT9085A/B/C-002
0 ±3 dBm (CW)
Output Optical Fiber
MT9085A/B/C-002
10 μm/125 μm, SMF (ITU-T G.652)
Optical Connector
MT9085A/B/C-002
2.5 mm universal
Laser Safety
MT9085A/B/C-002
IEC 60825-1: 2014 CLASS 3R
Operating Temperature and Humidity
MT9085A/B/C-002
0°C to +50°C, <80% (non-condensing)
General
Dimensions (without protector) 270 (W) × 165 (H) × 61 (D) mm, 10.6 × 6.5 × 2.4 inches
Mass (without protector) 1.6 kg without battery, 1.9 kg including battery
Dimensions (with protector, option 010) 284 (W) × 200 (H) × 77 (D) mm, 11.2 × 7.9 × 3 inches
Mass (with protector, option 010) 2.6 kg including battery
Display 8-inch touch screen TFT-Color LCD
Interface USB 2.0: Type A × 3 (memory), USB1.1: MicroB × 1 (USB mass storage)
USB power supply is 500 mA
Wireless Interface WLAN via USB adapter connected to USB port
Product introduction lists WLAN/Bluetooth via USB adapter
Data Storage Internal memory: 1 GB (up to 50,000 traces), External memory (USB): up to 32 GB
Power Supply 12 V(dc), 100 V(ac) to 240 V(ac), Allowable input voltage range: 90 V to 264 V, 50 Hz/60 Hz
Battery Type Lithium ion
Battery Operating Time 12 hours
Telcordia GR-196-CORE Issue 2, September 2010; typical, backlight Low, sweeping halted at 25˚C
Battery Recharge Time <5 hours (power off)
Power Consumption 20 W max (recharging), 4 W standard (low backlight, sweep stopped)
Power Saving Functions Backlight off: Disable/1 to 99 minutes, Auto shutdown: Disable/1 to 99 minutes
Languages English, Simplified Chinese, Traditional Chinese, French, German, Italian, Korean, Portuguese, Russian, Spanish, Swedish and Japanese
User selectable
Environmental and Compliance
Operating Temperature and Humidity –10°C to +50°C, <80% (non-condensing)
Storage Temperature and Humidity –20°C to +60°C, <80% (non-condensing)
Vibration Conforming to MIL-T-28800E Class 3
Ingress Protection Rating IEC60529 IP51
Shock MIL-T-28800E Style A (46 cm height, 8 corners, 6 faces; 14 drops in total, power off)
Bump: IEC 60068-2-27, JIS C60068-2-27; Shock-on-desk: MIL-T-28800E (45° angle or 100 mm lifted edge, 4 drops in total, power on)
CE EMC 2014/30/EU, EN61326-1, EN61000-3-2; LVD 2014/35/EU, EN61010-1; RoHS 2011/65/EU, (EU) 2015/863, EN IEC 63000: 2018
UKCA EMC S.I. 2016 No.1091, EN 61326-1, EN61000-3-2; LVD S.I. 2016 No.1101, EN 61010-1; RoHS S.I. 2012 No.3032, EN IEC 63000:2018
Battery Pack Z0921A and AC Adapter Z1625A
Battery Lithium Ion secondary battery, 11.1 V, 4200 mAh
Battery Dimensions and Mass 53 (W) × 19 (H) × 215 (D) mm, 330 g (typ.)
Battery Environmental Conditions Charging: +5°C to +30°C, ≤80% RH; Discharging: –20°C to +60°C, ≤80% RH; Storage: –20°C to +50°C, ≤80% RH
AC Adapter Rated AC Input 100 V(ac) to 240 V(ac), 50 Hz/60 Hz
AC Adapter Rated DC Output 12 V(dc), 5 A
AC Adapter Environmental Conditions Operating: 0°C to +45°C, 20 to 80% RH; Storage: –20°C to +70°C, 10 to 90% RH

Applications

  • Installation and maintenance of trunk fibers
  • Core networks
  • Metro networks
  • Mobile fronthaul
  • Mobile backhaul
  • Access network troubleshooting
  • Drop cable break location
  • PON-based FTTx
  • Long haul and ultra-long haul networks
  • Premise networks
  • In-service live circuit maintenance
  • Macrobend analysis
  • Base station installation and maintenance
  • Cable certification testing

Options & Accessories

Option Description
MT9085A/B/C-025 FC-APC Connector — Key width 2.0 mm; can only connect APC-type optical fiber
MT9085A/B/C-026 SC-APC Connector — Can only connect APC-type optical fiber
MT9085A/B/C-037 FC Connector
MT9085A/B/C-038 ST Connector
MT9085A/B/C-039 DIN47256 Connector
MT9085A/B/C-040 SC Connector
MT9085A/B/C-002 Visual Fault Locator — Built-in visual light source option
MT9085A/B/C-004 SMF Optical Power Meter — –50 to +23 dBm
MT9085A/B/C-005 SMF High Power Optical Power Meter — –43 to +30 dBm
MT9085A/B/C-007 SMF/MMF Optical Power Meter — –67 to +6 dBm
MT9085A/B/C-010 Protector — Front Protector B0584A cover supplied with belt as standard
W3971AE MT9085 Series Operation Manual — Printed. Electronic version included on accessory CD Z1991A.
W3972AE MT9085 Series SCPI Remote Control Operation Manual — Printed. Electronic version included on accessory CD Z1991A.
B0745A Softcase
B0582A Soft carrying case — With shoulder strap. Can also accommodate main unit with fitted Option 010 Protector
B0583A Hard transit case — Dimensions 420 (W) × 330 (H) × 148 (D) mm
B0549 Hard carrying case
B0584A Front cover — Option 010 Protector cover only
Z0921A Battery Pack — Li-ion Secondary battery, 11.1 V(dc), 4200 mAh
Z1632A Battery Charger — Li-ion battery charger
J1295 Car plug cord
J0617B Replaceable optical connector (FC-PC) — For OTDR port, for option power meter port
J0618D Replaceable optical connector (ST) — For OTDR port, for option power meter port
J0618F Replaceable optical connector (HMS-10/A) — For OTDR port, for option power meter port
J0619B Replaceable optical connector (SC-PC) — For OTDR port, for option power meter port
J0739A Replaceable optical connector (FC-APC) — For OTDR port
J1697A Replaceable optical connector (SC-APC) — For OTDR port
J0057 Optical adapter FC type — FC-FC connector (JJ adapter)
J1335A MU/LC connector adapter — Ferrule connection adapter 2.5 mm → 1.25 mm for visual light source (Option 002 only)
MA9005B-37 Adapter for FC connector — For option power meter port (MT9085A/B/C-005)
MA9005B-38 Adapter for ST connector — For option power meter port (MT9085A/B/C-005)
MA9005B-40 Adapter for SC connector — For option power meter port (MT9085A/B/C-005)
LP-FC FC-PC power meter adapter — For option power meter port (MT9085A/B/C-007)
LP-ST ST-PC power meter adapter — For option power meter port (MT9085A/B/C-007)
LP-SC SC-PC power meter adapter — For option power meter port (MT9085A/B/C-007)
J1530A SC plug-in converter (UPC(P)-APC(J)) — Converts main unit SC/UPC connector to SC/APC
J1531A SC plug-in converter (APC(P)-UPC(J)) — Converts main unit SC/APC connector to SC/UPC
J1532A FC plug-in converter (UPC(P)-APC(J)) — Converts main unit FC/UPC connector to FC/APC
J1533A FC plug-in converter (APC(P)-UPC(J)) — Converts main unit FC/APC connector to FC/UPC
J1534A LC-SC plug-in converter (for SM, SC(P)-LC(J)) — Converts main unit SC connector to LC (SMF only)
J1535A LC-SC plug-in converter (for MM, SC(P)-LC(J)) — Converts main unit SC connector to LC (MMF 62.5/125 μm only)
Z0914A Ferrule cleaner — 1 pc
Z0915A Replacement reel for ferrule cleaner — 6 pcs for Z0914A
Z0284 Adapter cleaner — Stick type (200 pcs/set)
G0306C Video Inspection Probe — X400 magnification fixed. Displays fiber end-face condition on ACCESS Master screen and performs Pass/Fail evaluation; also supports end-face evaluation on PC with MX900030A software
J1950A USB-Ethernet converter — For remote GUI connection
NETWORKS NETWORKS PC analysis software — OTDR waveform analysis and report creation on Microsoft Windows PC (sold separately)

Documents & Resources