ACCESS Master MT9085 Series Handheld All-in-One OTDR with 8-inch Touchscreen
Handheld all-in-one OTDR with 8-inch touchscreen, built-in light source and power meter, and up to 46 dB dynamic range
- Wavelength
- 1310/1550 nm ±25 nm
- Dynamic Range (HR)
- 46/46 dB
- Dynamic Range (ER)
- 25/25 dB
- Dead Zone (Backscatter)
- ≤3.8/4.3 m
Overview
The Anritsu ACCESS Master MT9085 series is a compact handheld all-in-one tester for optical pulse tests (OTDR), optical loss and power measurements, and optical fiber end-face inspection. Applications range from installation and maintenance (I&M) of trunk fibers in core, metro, mobile fronthaul and mobile backhaul networks to troubleshooting access networks, such as locating breaks in drop cables.
The series keeps the hard keys and rotary knob of earlier ACCESS Master models and adds an 8-inch color LCD touchscreen. The pressure-sensitive touchscreen accepts input without removing work gloves. Three main units are offered: MT9085A (Standard Dynamic Range), MT9085B (Enhanced Dynamic Range) and MT9085C (High Performance Dynamic Range), each combined with an OTDR module option that sets the wavelengths.
Optical Pulse Test (OTDR)
The OTDR measures fiber transmission loss and length and detects events such as breaks in fiber continuity. Single mode and multimode fibers are supported, with models covering 850, 1300, 1310, 1490, 1550, 1625 and 1650 nm. The Fiber Visualizer function displays events such as splices, connectors and PON splitters as schematic icons with loss and reflectance Pass/Fail results. Two realtime sweep modes (high-speed and high S/N) help locate fiber bends, and PON analysis supports up to 1 × 128 branches.
Optical Power/Loss Measurement
A stabilized light source and a power meter are built in through the OTDR port as standard. Optional dedicated-port power meters enable optical loss test set (OLTS) measurements with one tester, and an optional visual fault locator shows light leaking at fiber breaks.
End-Face Inspection and Data Management
With the external G0306C Video Inspection Probe (sold separately), the instrument displays the connector ferrule end face and performs automatic Pass/Fail evaluation to IEC 61300-3-35. Measurement data can be saved as original files (.sor, .vipi), .csv, screen captures or PDF reports, and transferred via USB memory, USB cable, WLAN or Ethernet (USB adapters required). Remote control is available through a web browser GUI or remote commands.
Models in this series
| Model | Description | |
|---|---|---|
| MT9085A-053 |
ACCESS Master MT9085A-053 Handheld OTDR, 1310/1550 nm Single Mode, Standard Dynamic Range
Handheld all-in-one OTDR with 1310/1550 nm single-mode testing, 39/37.5 dB dynamic range, built-in light source and power meter |
Details → |
| MT9085A-057 |
ACCESS Master MT9085A-057 1310/1550/1625 nm SMF Handheld OTDR
Standard-class handheld ACCESS Master OTDR with 1310/1550/1625 nm single-mode wavelengths for macrobend analysis and fiber I&M. |
Details → |
| MT9085A-063 |
ACCESS Master MT9085A-063 Handheld OTDR, 1310/1550 nm SM and 850/1300 nm MM
Standard-dynamic-range handheld all-in-one OTDR for single mode and multimode fiber at 1310/1550 nm and 850/1300 nm with 8-inch touchscreen. |
Details → |
| MT9085B-053 |
ACCESS Master MT9085B-053 1310/1550 nm SMF Handheld OTDR (Enhanced Dynamic Range)
Handheld all-in-one OTDR with 1310/1550 nm single-mode wavelengths, 42/41 dB dynamic range and an 8-inch touchscreen |
Details → |
| MT9085B-055 |
ACCESS Master MT9085B-055 Handheld OTDR, 1310/1550/1650 nm SMF with Built-in Filter for Live Circuit Maintenance
Enhanced-model ACCESS Master handheld OTDR with 1310/1550 nm and filtered 1650 nm single-mode wavelengths for in-service fiber maintenance. |
Details → |
| MT9085B-056 |
ACCESS Master MT9085B-056 1310/1490/1550 nm SMF OTDR for FTTx/PON Installation and Maintenance
Handheld enhanced-range OTDR at 1310/1490/1550 nm for FTTx/PON installation and maintenance, with 42/41/41 dB dynamic range. |
Details → |
| MT9085B-057 |
ACCESS Master MT9085B-057 Enhanced Dynamic Range OTDR, 1310/1550/1625 nm Single Mode
Handheld all-in-one OTDR with 1310/1550/1625 nm single-mode wavelengths and 40/39/38 dB dynamic range for macrobend analysis. |
Details → |
| MT9085B-058 |
ACCESS Master MT9085B-058 Handheld OTDR, 1310/1490/1550/1625 nm SM
Enhanced-range ACCESS Master handheld OTDR with 1310/1490/1550/1625 nm single-mode wavelengths for FTTx/PON and CWDM band evaluation. |
Details → |
| MT9085B-063 |
ACCESS Master MT9085B-063 Enhanced SMF/MMF Handheld OTDR (1310/1550 nm SM, 850/1300 nm MM)
Handheld all-in-one OTDR for single-mode and multimode fiber at 1310/1550 nm SM and 850/1300 nm MM, with 42/41 dB SM dynamic range |
Details → |
| MT9085C-053 |
ACCESS Master MT9085C-053 High Performance 1310/1550 nm SMF Handheld OTDR
High-performance handheld OTDR with 1310/1550 nm single-mode wavelengths, 46/46 dB dynamic range, built-in light source and power meter. |
Details → |
| MT9085C-057 |
ACCESS Master MT9085C-057 High Performance 1310/1550/1625 nm Handheld OTDR
High Performance ACCESS Master handheld OTDR with 1310/1550/1625 nm single-mode wavelengths and up to 46 dB dynamic range. |
Details → |
Key Features
- 8-inch LCD touchscreen with visibility in direct sunlight
- Touchscreen, rotary knob and dedicated hard keys for efficient operation
- Pressure-sensitive touchscreen operable with work gloves
- Fiber Visualizer function for simple fiber path analysis with Pass/Fail evaluation
- High-speed and high S/N real-time sweep modes for fast fiber bend location
- 46 dB dynamic range max. and 0.8 m event dead zone
- Identification of each splitter event for up to 1 × 128 PON branches
- Built-in stabilized light source and optical power meter as standard
- Optional optical power meters, visual fault locator and external fiberscope
- Optical fiber end-face inspection with Pass/Fail evaluation to IEC 61300-3-35
- Installation Test function for automatic measurement of multiple fibers
- Bi-directional measurement and analysis function
- Live fiber detection and OTDR connection check
- Cable Certification Test function with PDF report output
- Scenario Manager Lite for automated testing without a PC
- Telcordia SR-4731 trace format support
- 1 GB internal memory for up to 50,000 traces
- Remote GUI control by web browser and remote commands
- Password protection function
- 12-hour battery operation
Specifications
|
Wavelength
MT9085C-053 |
1310/1550 nm ±25 nm |
|---|---|
|
Dynamic Range (HR)
MT9085C-053 |
46/46 dB
Typical; subtract 1 dB for guarantee. SNR = 1, averaging 180 sec., 25°C |
|
Dynamic Range (ER)
MT9085C-053 |
25/25 dB
Pulse width: 100 ns (ER Mode), Distance range: 100 km |
|
Dead Zone (Backscatter)
MT9085C-053 |
≤3.8/4.3 m
IOR = 1.500000 |
|
Wavelength
MT9085C-057 |
1310/1550/1625 nm ±25 nm |
|
Dynamic Range (HR)
MT9085C-057 |
46/46/44 dB
Typical; subtract 1 dB for guarantee. SNR = 1, averaging 180 sec., 25°C |
|
Dynamic Range (ER)
MT9085C-057 |
25/25/23 dB
Pulse width: 100 ns (ER Mode), Distance range: 100 km |
|
Dead Zone (Backscatter)
MT9085C-057 |
≤3.8/4.3/4.8 m
IOR = 1.500000 |
|
Wavelength
MT9085B-053 |
1310/1550 nm ±25 nm |
|
Dynamic Range
MT9085B-053 |
42/41 dB
Typical; subtract 1 dB for guarantee. SNR = 1, averaging 180 sec., 25°C |
|
Dead Zone (Backscatter)
MT9085B-053 |
≤5/5.5 m
IOR = 1.500000 |
|
Wavelength
MT9085B-055 |
1310/1550 nm ±25 nm, 1645 nm to 1655 nm
1650 nm port with built-in filter for in-service live circuits |
|
Dynamic Range
MT9085B-055 |
42/41/35 dB
Typical; subtract 1 dB for guarantee. At 1650 nm: with background light, 1310/1550 nm, –19 dBm CW light. Product introduction lists 41/41/35 dB |
|
Dead Zone (Backscatter)
MT9085B-055 |
≤5/5.5/6.5 m
IOR = 1.500000 |
|
Wavelength
MT9085B-056 |
1310/1490/1550 nm ±25 nm |
|
Dynamic Range
MT9085B-056 |
42/41/41 dB
Typical; subtract 1 dB for guarantee |
|
Dead Zone (Backscatter)
MT9085B-056 |
≤6/6.5/6.5 m
IOR = 1.500000 |
|
Wavelength
MT9085B-057 |
1310/1550/1625 nm ±25 nm |
|
Dynamic Range
MT9085B-057 |
40/39/38 dB
Typical; subtract 1 dB for guarantee |
|
Dead Zone (Backscatter)
MT9085B-057 |
≤6/6.5/7.5 m
IOR = 1.500000 |
|
Wavelength
MT9085B-058 |
1310/1490/1550/1625 nm ±25 nm |
|
Dynamic Range
MT9085B-058 |
42/41/41/40 dB
Typical; subtract 1 dB for guarantee |
|
Dead Zone (Backscatter)
MT9085B-058 |
≤7/7.5/7.5/8.5 m
IOR = 1.500000 |
|
Wavelength
MT9085B-063 |
1310/1550 nm ±25 nm, 850/1300 nm ±30 nm
HYBRID (SMF/MMF) |
|
Dynamic Range
MT9085B-063 |
42/41 dB (SMF), 29/28 dB (MMF)
Typical; subtract 1 dB for guarantee. At 50 μm/125 μm MM fiber the dynamic range drops by about 3.0 dB |
|
Dead Zone (Backscatter)
MT9085B-063 |
≤5/5.5 m, ≤4/5 m (3/4 m typ.)
IOR = 1.500000 |
|
Wavelength
MT9085A-053 |
1310/1550 nm ±25 nm |
|
Dynamic Range
MT9085A-053 |
39/37.5 dB
Typical; subtract 1 dB for guarantee |
|
Dead Zone (Backscatter)
MT9085A-053 |
≤5/5.5 m
IOR = 1.500000 |
|
Wavelength
MT9085A-057 |
1310/1550/1625 nm ±25 nm |
|
Dynamic Range
MT9085A-057 |
37/35.5/32.5 dB
Typical; subtract 1 dB for guarantee |
|
Dead Zone (Backscatter)
MT9085A-057 |
≤6/6.5/7.5 m
IOR = 1.500000 |
|
Wavelength
MT9085A-063 |
1310/1550 nm ±25 nm, 850/1300 nm ±30 nm
HYBRID (SMF/MMF) |
|
Dynamic Range
MT9085A-063 |
39/37.5 dB (SMF), 29/28 dB (MMF)
Typical; subtract 1 dB for guarantee. At 50 μm/125 μm MM fiber the dynamic range drops by about 3.0 dB |
|
Dead Zone (Backscatter)
MT9085A-063 |
≤5/5.5 m, ≤4/5 m (3/4 m typ.)
IOR = 1.500000 |
| Fiber Type |
Single Mode (SMF) 10/125 μm ITU-T G.652
Options 063: HYBRID (SMF/MMF) |
|---|---|
| Pulse Width (SMF) | 3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns |
|
Pulse Width (MMF)
MT9085A-063, MT9085B-063 |
3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000 ns
850 nm: Does not support 1000, 2000, 4000 ns |
| Dead Zone (Fresnel) |
≤1 m, 0.8 m (typ.)
Pulse width: 3 ns, return loss: 40 dB, 25°C, IOR = 1.500000 |
|
Measurement Mode
MT9085C-053, MT9085C-057 |
HR/ER
HR: High Resolution mode for short dead zone; ER: Enhanced Range mode for PON measurement |
| Laser Safety |
IEC 60825-1: 2014 CLASS 1
Complies with 21CFR1040.10 and 1040.11 except for conformance with IEC 60825-1 Ed.3., as described in Laser Notice No. 56 |
| Vertical Scale | 0.1, 0.2, 0.5, 1.0, 2.0, 5.0, 10.0 dB/div |
| IOR Setting | 1.300000 to 1.700000 (0.000001 steps) |
| Units | km, m, kft, ft, mi |
| Sampling Points |
Up to 150,001
Either high density value is selected depending on distance range |
| Sampling Resolution | 0.05 m to 60 m |
| Reflectance Accuracy (Single mode) |
±2 dB
When measuring the non-connected end of an approximately 25 km length fiber, Distance range: 50 km, Pulse width: 2 μs |
| Reflectance Accuracy (Multimode) |
±4 dB
When measuring the non-connected end of an approximately 4.5 km length fiber, Distance range: 10 km, Pulse width: 100 ns |
| Distance Accuracy |
±1 m ±3 × measurement distance × 10^-5 ± marker resolution
Excluding IOR uncertainty |
| Loss Measurement Accuracy (Linearity) | ±0.05 dB/dB or ±0.1 dB (whichever is greater) |
| Distance Range (Single mode) | 0.5, 1, 2.5, 5, 10, 25, 50, 100, 200, 300 km |
| Distance Range (Multimode) | 0.5, 1, 2.5, 5, 10, 25, 50, 100 km |
| Event Pass/Fail Threshold (reflective and non-reflective events) |
0.01 to 9.99 dB (0.01-dB steps)
User defined |
| Reflectance Threshold |
70.0 to 20.0 dB (0.1-dB steps)
User defined |
| Fiber End/Break Threshold |
1 to 99 dB (1-dB steps)
User defined |
| Number of Detected Events |
up to 99
Macrobend detection supported |
| OTDR Trace Format | Telcordia universal. SOR, issue 2 (SR-4731) |
| Real Time Sweep |
0.15 sec.
Resolution: Low Density |
| Loss Modes | 2-point loss, dB/km, 2-point LSA, splice loss, ORL |
| Averaging Modes | Timed (1 to 3600 s) |
| Other Functions | Live Fiber detect, Connection check, Trace overlay and comparison, Template function, USB keyboard support, Remote control, Remote GUI, Password protection feature |
| Wavelength |
Same as OTDR
CW, 25°C |
|---|---|
| Spectral Width |
≤5 nm (1310 nm), ≤10 nm (850/1300/1490/1550/1625 nm), ≤3 nm (1650 nm)
CW, 25°C |
| Wavelength Accuracy |
850/1300/1310/1490/1550/1625 nm: ±30 nm; 1650 nm: ±5 nm
CW, 25°C |
| Output Power |
–5 ±1.5 dBm
CW, 25°C |
| Output Stability |
≤0.1 dB
CW, –10°C to 50°C (±1°C) difference between max/min. values over 1 minute, SM fiber 2 m |
| Modes of Operation |
CW, 270 Hz, 1 kHz, 2 kHz
Modulation +1.5% with 10 minute warm up |
| Maximum Input |
+10 dBm
Not available if Option 004, 005 or 007 is ordered |
|---|---|
| Measurement Range | –50 to –5 dBm |
| Accuracy |
±6.5%
CW input, –20 dBm at 1550 nm, 23°C ±2, Anritsu reference single mode fiber with FC/UPC connector |
| Setting Wavelengths |
1310, 1550, 1625, 1650 nm
Options 053, 055, 057, 063 |
|
Setting Wavelengths
MT9085B-056, MT9085B-058 |
1310, 1490, 1550, 1625 nm
Options 056, 058 |
| Features | Store reference, loss table |
|
Measurement Range
MT9085A/B/C-007 |
–67 to +6 dBm (CW, 1310 nm)
Peak power, subtract 3 dB for modulated tones; –60 to +3 dBm @850 nm |
|---|---|
|
Measurement Range
MT9085A/B/C-004 |
–50 to +23 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones |
|
Measurement Range
MT9085A/B/C-005 |
–43 to +30 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones |
|
Fiber Type
MT9085A/B/C-007 |
Single Mode: 10 μm/125 μm (G.652), Multimode: 62.5 μm/125 μm |
|
Fiber Type
MT9085A/B/C-004, MT9085A/B/C-005 |
Single Mode: 10 μm/125 μm (G.652)
Option 005: PC only for UPC connector |
|
Wavelength Range
MT9085A/B/C-007 |
800 nm to 1700 nm |
|
Wavelength Range
MT9085A/B/C-004, MT9085A/B/C-005 |
1200 nm to 1700 nm |
|
Setting Wavelengths
MT9085A/B/C-007 |
850, 1300, 1310, 1383, 1490, 1550, 1625, 1650 nm |
|
Setting Wavelengths
MT9085A/B/C-004, MT9085A/B/C-005 |
1310, 1383, 1490, 1550, 1625, 1650 nm |
|
Optical Connector
MT9085A/B/C-007 |
Universal – uses LP-XX adapters |
|
Optical Connector
MT9085A/B/C-004 |
Universal – uses JXXXX adapters (same as OTDR) |
|
Optical Connector
MT9085A/B/C-005 |
Universal – uses MA9005B adapters |
|
Accuracy
MT9085A/B/C-007 |
±5% (1310 nm/1550 nm), ±0.5 dB (850 nm)
CW, at –10 dBm, 25°C, Anritsu reference SM fiber with FC/UPC connector, after zero offset |
|
Accuracy
MT9085A/B/C-004, MT9085A/B/C-005 |
±5% (1310 nm/1550 nm)
Option 004: CW at –10 dBm; Option 005: CW at 0 dBm; 25°C, after zero offset |
|
Reflectance
MT9085A/B/C-004 |
≥36 dB
Using SM fiber (ITU-T G.652) |
|
Modulation
MT9085A/B/C-004, MT9085A/B/C-005, MT9085A/B/C-007 |
CW, 270 Hz, 1 kHz, 2 kHz |
|
Operating Temperature and Humidity
MT9085A/B/C-004, MT9085A/B/C-005, MT9085A/B/C-007 |
0°C to +50°C, <80% (non-condensing) |
|
Central Wavelength
MT9085A/B/C-002 |
650 nm±15 nm (at 25˚C) |
|---|---|
|
Optical Output
MT9085A/B/C-002 |
0 ±3 dBm (CW) |
|
Output Optical Fiber
MT9085A/B/C-002 |
10 μm/125 μm, SMF (ITU-T G.652) |
|
Optical Connector
MT9085A/B/C-002 |
2.5 mm universal |
|
Laser Safety
MT9085A/B/C-002 |
IEC 60825-1: 2014 CLASS 3R |
|
Operating Temperature and Humidity
MT9085A/B/C-002 |
0°C to +50°C, <80% (non-condensing) |
| Dimensions (without protector) | 270 (W) × 165 (H) × 61 (D) mm, 10.6 × 6.5 × 2.4 inches |
|---|---|
| Mass (without protector) | 1.6 kg without battery, 1.9 kg including battery |
| Dimensions (with protector, option 010) | 284 (W) × 200 (H) × 77 (D) mm, 11.2 × 7.9 × 3 inches |
| Mass (with protector, option 010) | 2.6 kg including battery |
| Display | 8-inch touch screen TFT-Color LCD |
| Interface |
USB 2.0: Type A × 3 (memory), USB1.1: MicroB × 1 (USB mass storage)
USB power supply is 500 mA |
| Wireless Interface |
WLAN via USB adapter connected to USB port
Product introduction lists WLAN/Bluetooth via USB adapter |
| Data Storage | Internal memory: 1 GB (up to 50,000 traces), External memory (USB): up to 32 GB |
| Power Supply | 12 V(dc), 100 V(ac) to 240 V(ac), Allowable input voltage range: 90 V to 264 V, 50 Hz/60 Hz |
| Battery Type | Lithium ion |
| Battery Operating Time |
12 hours
Telcordia GR-196-CORE Issue 2, September 2010; typical, backlight Low, sweeping halted at 25˚C |
| Battery Recharge Time | <5 hours (power off) |
| Power Consumption | 20 W max (recharging), 4 W standard (low backlight, sweep stopped) |
| Power Saving Functions | Backlight off: Disable/1 to 99 minutes, Auto shutdown: Disable/1 to 99 minutes |
| Languages |
English, Simplified Chinese, Traditional Chinese, French, German, Italian, Korean, Portuguese, Russian, Spanish, Swedish and Japanese
User selectable |
| Operating Temperature and Humidity | –10°C to +50°C, <80% (non-condensing) |
|---|---|
| Storage Temperature and Humidity | –20°C to +60°C, <80% (non-condensing) |
| Vibration | Conforming to MIL-T-28800E Class 3 |
| Ingress Protection Rating | IEC60529 IP51 |
| Shock |
MIL-T-28800E Style A (46 cm height, 8 corners, 6 faces; 14 drops in total, power off)
Bump: IEC 60068-2-27, JIS C60068-2-27; Shock-on-desk: MIL-T-28800E (45° angle or 100 mm lifted edge, 4 drops in total, power on) |
| CE | EMC 2014/30/EU, EN61326-1, EN61000-3-2; LVD 2014/35/EU, EN61010-1; RoHS 2011/65/EU, (EU) 2015/863, EN IEC 63000: 2018 |
| UKCA | EMC S.I. 2016 No.1091, EN 61326-1, EN61000-3-2; LVD S.I. 2016 No.1101, EN 61010-1; RoHS S.I. 2012 No.3032, EN IEC 63000:2018 |
| Battery | Lithium Ion secondary battery, 11.1 V, 4200 mAh |
|---|---|
| Battery Dimensions and Mass | 53 (W) × 19 (H) × 215 (D) mm, 330 g (typ.) |
| Battery Environmental Conditions | Charging: +5°C to +30°C, ≤80% RH; Discharging: –20°C to +60°C, ≤80% RH; Storage: –20°C to +50°C, ≤80% RH |
| AC Adapter Rated AC Input | 100 V(ac) to 240 V(ac), 50 Hz/60 Hz |
| AC Adapter Rated DC Output | 12 V(dc), 5 A |
| AC Adapter Environmental Conditions | Operating: 0°C to +45°C, 20 to 80% RH; Storage: –20°C to +70°C, 10 to 90% RH |
Applications
- Installation and maintenance of trunk fibers
- Core networks
- Metro networks
- Mobile fronthaul
- Mobile backhaul
- Access network troubleshooting
- Drop cable break location
- PON-based FTTx
- Long haul and ultra-long haul networks
- Premise networks
- In-service live circuit maintenance
- Macrobend analysis
- Base station installation and maintenance
- Cable certification testing
Options & Accessories
| Option | Description |
|---|---|
| MT9085A/B/C-025 | FC-APC Connector — Key width 2.0 mm; can only connect APC-type optical fiber |
| MT9085A/B/C-026 | SC-APC Connector — Can only connect APC-type optical fiber |
| MT9085A/B/C-037 | FC Connector |
| MT9085A/B/C-038 | ST Connector |
| MT9085A/B/C-039 | DIN47256 Connector |
| MT9085A/B/C-040 | SC Connector |
| MT9085A/B/C-002 | Visual Fault Locator — Built-in visual light source option |
| MT9085A/B/C-004 | SMF Optical Power Meter — –50 to +23 dBm |
| MT9085A/B/C-005 | SMF High Power Optical Power Meter — –43 to +30 dBm |
| MT9085A/B/C-007 | SMF/MMF Optical Power Meter — –67 to +6 dBm |
| MT9085A/B/C-010 | Protector — Front Protector B0584A cover supplied with belt as standard |
| W3971AE | MT9085 Series Operation Manual — Printed. Electronic version included on accessory CD Z1991A. |
| W3972AE | MT9085 Series SCPI Remote Control Operation Manual — Printed. Electronic version included on accessory CD Z1991A. |
| B0745A | Softcase |
| B0582A | Soft carrying case — With shoulder strap. Can also accommodate main unit with fitted Option 010 Protector |
| B0583A | Hard transit case — Dimensions 420 (W) × 330 (H) × 148 (D) mm |
| B0549 | Hard carrying case |
| B0584A | Front cover — Option 010 Protector cover only |
| Z0921A | Battery Pack — Li-ion Secondary battery, 11.1 V(dc), 4200 mAh |
| Z1632A | Battery Charger — Li-ion battery charger |
| J1295 | Car plug cord |
| J0617B | Replaceable optical connector (FC-PC) — For OTDR port, for option power meter port |
| J0618D | Replaceable optical connector (ST) — For OTDR port, for option power meter port |
| J0618F | Replaceable optical connector (HMS-10/A) — For OTDR port, for option power meter port |
| J0619B | Replaceable optical connector (SC-PC) — For OTDR port, for option power meter port |
| J0739A | Replaceable optical connector (FC-APC) — For OTDR port |
| J1697A | Replaceable optical connector (SC-APC) — For OTDR port |
| J0057 | Optical adapter FC type — FC-FC connector (JJ adapter) |
| J1335A | MU/LC connector adapter — Ferrule connection adapter 2.5 mm → 1.25 mm for visual light source (Option 002 only) |
| MA9005B-37 | Adapter for FC connector — For option power meter port (MT9085A/B/C-005) |
| MA9005B-38 | Adapter for ST connector — For option power meter port (MT9085A/B/C-005) |
| MA9005B-40 | Adapter for SC connector — For option power meter port (MT9085A/B/C-005) |
| LP-FC | FC-PC power meter adapter — For option power meter port (MT9085A/B/C-007) |
| LP-ST | ST-PC power meter adapter — For option power meter port (MT9085A/B/C-007) |
| LP-SC | SC-PC power meter adapter — For option power meter port (MT9085A/B/C-007) |
| J1530A | SC plug-in converter (UPC(P)-APC(J)) — Converts main unit SC/UPC connector to SC/APC |
| J1531A | SC plug-in converter (APC(P)-UPC(J)) — Converts main unit SC/APC connector to SC/UPC |
| J1532A | FC plug-in converter (UPC(P)-APC(J)) — Converts main unit FC/UPC connector to FC/APC |
| J1533A | FC plug-in converter (APC(P)-UPC(J)) — Converts main unit FC/APC connector to FC/UPC |
| J1534A | LC-SC plug-in converter (for SM, SC(P)-LC(J)) — Converts main unit SC connector to LC (SMF only) |
| J1535A | LC-SC plug-in converter (for MM, SC(P)-LC(J)) — Converts main unit SC connector to LC (MMF 62.5/125 μm only) |
| Z0914A | Ferrule cleaner — 1 pc |
| Z0915A | Replacement reel for ferrule cleaner — 6 pcs for Z0914A |
| Z0284 | Adapter cleaner — Stick type (200 pcs/set) |
| G0306C | Video Inspection Probe — X400 magnification fixed. Displays fiber end-face condition on ACCESS Master screen and performs Pass/Fail evaluation; also supports end-face evaluation on PC with MX900030A software |
| J1950A | USB-Ethernet converter — For remote GUI connection |
| NETWORKS | NETWORKS PC analysis software — OTDR waveform analysis and report creation on Microsoft Windows PC (sold separately) |