Anritsu ACCESS Master MT9085 Series handheld OTDR front view
MT9085B-057

ACCESS Master MT9085B-057 Enhanced Dynamic Range OTDR, 1310/1550/1625 nm Single Mode

Handheld all-in-one OTDR with 1310/1550/1625 nm single-mode wavelengths and 40/39/38 dB dynamic range for macrobend analysis.

Wavelength
1310/1550/1625 nm ±25 nm
Fiber type
Single Mode (SMF) 10/125 μm ITU-T G.652
Pulse width
3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns
Dynamic range
40/39/38 dB

Overview

The ACCESS Master MT9085B-057 is the Enhanced Dynamic Range (B-type) model of the Anritsu MT9085 series configured with a three-wavelength single-mode OTDR module at 1310, 1550 and 1625 nm. Anritsu positions this wavelength set for maintenance work that uses macrobend analysis, with a typical dynamic range of 40/39/38 dB and an event dead zone of 0.8 m (typ.).

Like the rest of the MT9085 series, the unit is a compact handheld all-in-one tester for optical pulse tests, optical loss and power measurements, and fiber end-face inspection. It covers installation and maintenance of trunk fibers (core, metro, mobile fronthaul and backhaul) as well as troubleshooting of access networks, such as breaks in drop cables.

Operation

The instrument has an 8-inch color LCD touchscreen and keeps the rotary knob and dedicated hard keys of earlier ACCESS Master models. The Fiber Visualizer function shows fiber events such as splices, connectors and PON splitters as schematic icons, with Pass/Fail evaluation of loss and reflectance. Two realtime sweep modes, high-speed and high S/N, help locate fiber bends while watching the waveform. Manual analysis uses four markers with the two-point and LSA methods.

Power, loss and inspection

A stabilized light source and an optical power meter are built in as standard and share the OTDR port. Optional dedicated power meter ports (options 004, 005, 007) add optical loss test set measurements, and option 002 adds a visual fault locator. With the external G0306C Video Inspection Probe, the unit inspects connector end faces and evaluates Pass/Fail to IEC 61300-3-35.

Data handling

Traces are saved in Telcordia SR-4731 (.sor) format, up to 50,000 traces in 1 GB of internal memory. Data can be transferred over USB memory, USB cable, or WLAN or Ethernet through USB adapters. The unit can be controlled remotely through a web browser GUI or remote commands, and it produces PDF reports.

Key Features

  • 8-inch LCD touchscreen with easy visibility even in direct sunlight
  • Operation via touchscreen, rotary knob and dedicated hard keys
  • Fiber Visualizer function for simple fiber path analysis with Pass/Fail evaluation
  • High-speed and high S/N real-time sweep modes for fast fiber bend location
  • Three single-mode wavelengths 1310/1550/1625 nm for maintenance using macrobend analysis
  • 40/39/38 dB dynamic range (typ.) and 0.8 m (typ.) event dead zone
  • Identification of each splitter event for PON networks up to 1 × 128 branches
  • Built-in stabilized light source and optical power meter through the OTDR port
  • Optional dedicated optical power meter ports for optical loss test set measurements
  • Optional built-in visual fault locator
  • Optical fiber end-face inspection using external Video Inspection Probe G0306C
  • Installation Test function for automatic measurement of multiple fibers
  • Bi-directional measurement analysis
  • Cable Certification Test function with Pass/Fail to IEC/ISO standards
  • Live fiber detection and OTDR connection check
  • Telcordia SR-4731 trace format support
  • Scenario Manager Lite for automated testing without a PC
  • Remote control via web browser GUI and remote commands
  • Password protection function
  • 12-hour battery operation

Specifications

OTDR
Wavelength 1310/1550/1625 nm ±25 nm
25°C, pulse width: 1 μs
Fiber type Single Mode (SMF) 10/125 μm ITU-T G.652
Pulse width 3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns
Dynamic range 40/39/38 dB
Typical, subtract 1 dB for guarantee. One-way back-scattered light, pulse width 20 μs, distance range 100 km, averaging 180 sec., SNR = 1, 25°C
Dead zone (Fresnel) ≤1 m, 0.8 m (typ.)
IOR = 1.500000, pulse width 3 ns, return loss 40 dB, 25°C
Dead zone (backscatter) ≤6/6.5/7.5 m
IOR = 1.500000, pulse width 10 ns, return loss 55 dB, deviation ±0.5 dB, 25°C
Laser safety IEC 60825-1: 2014 CLASS 1
Complies with 21CFR1040.10 and 1040.11 except for conformance with IEC 60825-1 Ed.3., as described in Laser Notice No. 56, dated May 8, 2014
Sampling points Up to 150,001
Either high density value is selected depending on distance range
Sampling resolution 0.05 m to 60 m
Reflectance accuracy Single mode: ±2 dB
When measuring the non-connected end of an approximately 25 km length fiber, distance range: 50 km, pulse width: 2 μs
Distance accuracy ±1 m ±3 × measurement distance × 10^-5 ± marker resolution
Excluding IOR uncertainty
Loss measurement accuracy (linearity) ±0.05 dB/dB or ±0.1 dB (whichever is greater)
Distance range Single mode: 0.5, 1, 2.5, 5, 10, 25, 50, 100, 200, 300 km
Vertical scale 0.1, 0.2, 0.5, 1.0, 2.0, 5.0, 10.0 dB/div
IOR setting 1.300000 to 1.700000 (0.000001 steps)
Units km, m, kft, ft, mi
Real time sweep 0.15 sec.
Resolution: Low Density
OTDR trace format Telcordia universal. SOR, issue 2 (SR-4731)
Testing Modes and Analysis
Testing modes Fiber Visualizer; Standard OTDR (user selectable automatic or manual set-up); Construction OTDR (automated, multi-wavelength testing); Light source; Loss test set (optional); Connector Video Inspection Probe (optional); Visual fault locator (optional)
Fiber event analysis Auto or manual operation, displayed in table format
Pass/Fail threshold, reflective and non-reflective events 0.01 to 9.99 dB (0.01-dB steps)
User defined
Pass/Fail threshold, reflectance 70.0 to 20.0 dB (0.1-dB steps)
User defined
Pass/Fail threshold, fiber end/break 1 to 99 dB (1-dB steps)
User defined
Number of detected events up to 99
Macrobend detection supported
Loss modes 2-point loss, dB/km, 2-point LSA, splice loss, ORL
Averaging modes Timed (1 to 3600 s)
Other functions Live Fiber detect, Connection check, Trace overlay and comparison, Template function, USB keyboard support, Remote control, Remote GUI, Password protection feature
Standard Light Source (through OTDR port)
Wavelength Same as OTDR
CW, 25°C
Spectral width ≤5 nm (1310 nm), ≤10 nm (1550/1625 nm)
CW, 25°C
Wavelength accuracy ±30 nm
CW, 25°C; 1310/1550/1625 nm
Output power –5 ±1.5 dBm
CW, 25°C
Output stability ≤0.1 dB
CW, –10°C to 50°C (±1°C), difference between max/min values over 1 minute, SM fiber 2 m
Modes of operation CW, 270 Hz, 1 kHz, 2 kHz
Modulation +1.5% with 10 minute warm up
Standard Integrated Power Meter (through OTDR port)
Maximum input +10 dBm
Not available if option 004, 005 or 007 is ordered
Measurement range –50 to –5 dBm
Accuracy ±6.5%
CW input, –20 dBm at 1550 nm, 23°C ±2, using Anritsu's reference single mode fiber with FC/UPC connector
Setting wavelengths 1310, 1550, 1625, 1650 nm
Options 053, 055, 057, 063
Features Store reference, loss table
Loss Test Set Power Meters (optional)
Measurement range
MT9085A/B/C-004
–50 to +23 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones
Measurement range
MT9085A/B/C-005
–43 to +30 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones
Measurement range
MT9085A/B/C-007
–67 to +6 dBm (CW, 1310 nm)
Peak power, subtract 3 dB for modulated tones; –60 to +3 dBm at 850 nm
Wavelength range
MT9085A/B/C-007
800 nm to 1700 nm
Wavelength range
MT9085A/B/C-004, MT9085A/B/C-005
1200 nm to 1700 nm
Modulation CW, 270 Hz, 1 kHz, 2 kHz
Operating temperature and humidity 0°C to +50°C, <80% (non-condensing)
Visual Light Source (Option 002)
Central wavelength
MT9085A/B/C-002
650 nm±15 nm
at 25°C
Optical output
MT9085A/B/C-002
0 ±3 dBm (CW)
Output optical fiber
MT9085A/B/C-002
10 μm/125 μm, SMF (ITU-T G.652)
Optical connector
MT9085A/B/C-002
2.5 mm universal
Laser safety
MT9085A/B/C-002
IEC 60825-1: 2014 CLASS 3R
General
Display 8-inch touch screen TFT-Color LCD
Interface USB 2.0: Type A × 3 (memory), USB1.1: MicroB × 1 (USB mass storage)
USB power supply is 500 mA
Wireless interface WLAN via USB adapter connected to USB port
Data storage Internal memory: 1 GB (up to 50,000 traces), External memory (USB): up to 32 GB
Languages English, Simplified Chinese, Traditional Chinese, French, German, Italian, Korean, Portuguese, Russian, Spanish, Swedish and Japanese
User selectable
Power
Power supply 12 V(dc), 100 V(ac) to 240 V(ac), Allowable input voltage range: 90 V to 264 V, 50 Hz/60 Hz
Battery type Lithium ion
Battery Pack Z0921A: 11.1 V, 4200 mAh
Battery operating time 12 hours
Telcordia GR-196-CORE Issue 2, September 2010; typical, backlight low, sweeping halted at 25°C
Recharge time <5 hours (power off)
Power consumption 20 W max (recharging), 4 W standard (low backlight, sweep stopped)
Power saving functions Backlight off: Disable/1 to 99 minutes, Auto shutdown: Disable/1 to 99 minutes
AC adapter Z1625A rated output 12 V(dc), 5 A
Rated AC input 100 V(ac) to 240 V(ac), 50 Hz/60 Hz
Physical
Dimensions without protector 270 (W) × 165 (H) × 61 (D) mm, 10.6 × 6.5 × 2.4 inches
Mass without protector 1.6 kg without battery, 1.9 kg including battery
Dimensions with protector (option 010) 284 (W) × 200 (H) × 77 (D) mm, 11.2 × 7.9 × 3 inches
Mass with protector (option 010) 2.6 kg including battery
Environmental
Operating temperature and humidity –10°C to +50°C, <80% (non-condensing)
Storage temperature and humidity –20°C to +60°C, <80% (non-condensing)
Vibration Conforming to MIL-T-28800E Class 3
Ingress protection rating IEC60529 IP51
Shock MIL-T-28800E Style A (46 cm height, 8 corners, 6 faces; 14 drops in total, power off), Bump: IEC 60068-2-27, JIS C60068-2-27
Shock-on-desk: MIL-T-28800E (45° angle or 100 mm lifted edge, 4 drops in total, power on)
CE EMC 2014/30/EU, EN61326-1, EN61000-3-2; LVD 2014/35/EU, EN61010-1; RoHS 2011/65/EU, (EU) 2015/863, EN IEC 63000: 2018
UKCA EMC S.I. 2016 No.1091, EN 61326-1, EN61000-3-2; LVD S.I. 2016 No.1101, EN 61010-1; RoHS S.I. 2012 No.3032, EN IEC 63000:2018

Applications

  • Installation and maintenance of trunk fibers
  • Core and metro networks
  • Mobile fronthaul and backhaul
  • Access network troubleshooting
  • Drop cable break location
  • Macrobend analysis
  • PON-based FTTx
  • Long haul networks
  • Base station installation and maintenance

Included

  • Z1991A MT9085 Operation Manual (CD)
  • W3974AE MT9085 Series Quick Guide
  • Z1625A AC adapter
  • Line cord
  • Z0921A Battery Pack

Options & Accessories

Option Description
MT9085A/B/C-025 FC-APC Connector Key width 2.0 mm — Can only connect APC-type optical fiber
MT9085A/B/C-026 SC-APC Connector — Can only connect APC-type optical fiber
MT9085A/B/C-037 FC Connector
MT9085A/B/C-038 ST Connector
MT9085A/B/C-039 DIN47256 Connector
MT9085A/B/C-040 SC Connector
MT9085A/B/C-002 Visual Fault Locator — Built-in visual light source option
MT9085A/B/C-004 SMF Optical Power Meter — –50 to +23 dBm
MT9085A/B/C-005 SMF High Power Optical Power Meter — –43 to +30 dBm
MT9085A/B/C-007 SMF/MMF Optical Power Meter — –67 to +6 dBm
MT9085A/B/C-010 Protector — Front Protector B0584A cover supplied with belt as standard
G0306C Video Inspection Probe — X400 magnification fixed. Displays fiber end-face condition on ACCESS Master screen and performs Pass/Fail evaluation
W3971AE MT9085 Series Operation Manual — Printed. Electronic version included on accessory CD Z1991A.
W3972AE MT9085 Series SCPI Remote Control Operation Manual — Printed. Electronic version included on accessory CD Z1991A.
B0745A Softcase
B0582A Soft carrying case — With shoulder strap. Can also accommodate main unit with fitted Option 010 Protector
B0583A Hard transit case — Dimensions 420 (W) × 330 (H) × 148 (D) mm
B0549 Hard carrying case
B0584A Front cover — Option 010 Protector cover only
Z0921A Battery Pack — Li-ion Secondary battery, 11.1 V(dc), 4200 mAh
Z1632A Battery Charger — Li-ion battery charger
J1295 Car plug cord
J0617B Replaceable optical connector (FC-PC) — For OTDR port, for option power meter port
J0618D Replaceable optical connector (ST) — For OTDR port, for option power meter port
J0618F Replaceable optical connector (HMS-10/A) — For OTDR port, for option power meter port
J0619B Replaceable optical connector (SC-PC) — For OTDR port, for option power meter port
J0739A Replaceable optical connector (FC-APC) — For OTDR port
J1697A Replaceable optical connector (SC-APC) — For OTDR port
J0057 Optical adapter FC type — FC-FC connector (JJ adapter)
J1335A MU/LC connector adapter — Ferrule connection adapter 2.5 mm → 1.25 mm for visual light source (Option 002 only)
MA9005B-37 For FC connector — For option power meter port (MT9085A/B/C-005)
MA9005B-38 For ST connector — For option power meter port (MT9085A/B/C-005)
MA9005B-40 For SC connector — For option power meter port (MT9085A/B/C-005)
LP-FC FC-PC power meter adapter — For option power meter port (MT9085A/B/C-007)
LP-ST ST-PC power meter adapter — For option power meter port (MT9085A/B/C-007)
LP-SC SC-PC power meter adapter — For option power meter port (MT9085A/B/C-007)
J1530A SC plug in converter (UPC(P)-APC(J)) — Converts main unit SC/UPC connector to SC/APC
J1531A SC plug in converter (APC(P)-UPC(J)) — Converts main unit SC/APC connector to SC/UPC
J1532A FC plug in converter (UPC(P)-APC(J)) — Converts main unit FC/UPC connector to FC/APC
J1533A FC plug in converter (APC(P)-UPC(J)) — Converts main unit FC/APC connector to FC/UPC
J1534A LC-SC Plug-in Converter (for SM, SC(P)-LC(J)) — Converts main unit SC connector to LC (SMF only)
J1535A LC-SC Plug-in Converter (for MM, SC(P)-LC(J)) — Converts main unit SC connector to LC (MMF 62.5/125 μm only)
Z0914A Ferrule cleaner — 1 pc
Z0915A Replacement reel for ferrule cleaner — 6 pcs for Z0914A
Z0284 Adapter Cleaner — Stick type (200 pcs/set)
J1950A USB-Ethernet converter — For remote GUI connection
NETWORKS NETWORKS PC analysis software — OTDR waveform analysis and report creation on Windows PC (sold separately)