ACCESS Master MT9085A-053 Handheld OTDR, 1310/1550 nm Single Mode, Standard Dynamic Range
Handheld all-in-one OTDR with 1310/1550 nm single-mode testing, 39/37.5 dB dynamic range, built-in light source and power meter
- Wavelength
- 1310/1550 nm ±25 nm
- Fiber type
- Single Mode (SMF) 10/125 μm ITU-T G.652
- Pulse width
- 3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns
- Dynamic range
- 39/37.5 dB
Overview
The ACCESS Master MT9085A-053 is the standard-dynamic-range, general-purpose model of the Anritsu MT9085 series. It is a compact handheld all-in-one tester that combines an optical time domain reflectometer (OTDR) at 1310/1550 nm on single-mode fiber with optical loss and power measurement. With the external fiberscope option, it also inspects optical fiber end faces. Anritsu positions it as the standard model for installation and maintenance (I&M) in general-purpose, premise, access and metro applications.
Optical pulse test (OTDR)
The OTDR measures fiber transmission loss and length and detects events such as breaks in fiber continuity. The Fiber Visualizer function shows splices, connectors, splitters and the fiber end as schematic icons, with distance, loss and reflectance Pass/Fail results. Two real-time sweep modes, high-speed and high S/N, help locate fiber bends while the waveform is monitored. For manual analysis, the instrument offers the rotary knob, dedicated hard keys and four-marker loss and reflectance analysis from earlier ACCESS Master models, together with an 8-inch touchscreen.
Optical power, loss and end-face inspection
A stabilized light source and an optical power meter are built in as standard and use the OTDR port. Optional dedicated power meter ports, a visual fault locator and the G0306C Video Inspection Probe add optical loss testing (OLTS), visual fiber break location and IEC 61300-3-35 end-face Pass/Fail evaluation.
Data management
Measurements can be saved in original formats (Telcordia .sor for OTDR, .vipi for VIP), as .csv files, as screen captures or as PDF reports. Data can be transferred by USB memory, USB cable, or by WLAN or Ethernet through USB adapters. The instrument can be controlled remotely through a web-browser GUI or remote commands.
Key Features
- 8-inch touchscreen TFT color LCD readable in direct sunlight
- Touchscreen operation combined with rotary knob and dedicated hard keys
- Pressure-sensitive touchscreen usable without removing work gloves
- Fiber Visualizer displays fiber events as schematic icons with Pass/Fail evaluation
- High-speed and high S/N real-time sweep modes for fiber bend location
- PON splitter event identification for up to 1 × 128 branches
- Built-in stabilized light source and optical power meter through the OTDR port
- Optional visual fault locator and dedicated optical power meter ports
- Optical fiber end-face inspection with the external G0306C Video Inspection Probe
- Installation Test function for automatic measurement of multiple fibers
- Bi-directional trace analysis for accurate splice loss
- Cable Certification Test with automatic Pass/Fail to IEC/ISO standards
- Scenario Manager Lite for automated test execution without a PC
- Live fiber detection and OTDR connection check
- Telcordia SR-4731 .sor trace format support
- 1 GB internal memory for up to 50,000 traces
- 12-hour battery operation
- Password protection function
- Remote control via web-browser GUI and remote commands
Specifications
| Wavelength |
1310/1550 nm ±25 nm
25°C, pulse width: 1 μs
|
|---|---|
| Fiber type | Single Mode (SMF) 10/125 μm ITU-T G.652 |
| Pulse width | 3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns |
| Dynamic range |
39/37.5 dB
Typical. Subtract 1 dB for guarantee. Pulse width 20 μs, distance range 100 km, averaging 180 sec., SNR = 1, 25°C
|
| Dead zone (Fresnel) |
≤1 m, 0.8 m (typ.)
IOR = 1.500000; pulse width 3 ns, return loss 40 dB, 25°C
|
| Dead zone (backscatter) |
≤5/5.5 m
IOR = 1.500000; pulse width 10 ns, return loss 55 dB, deviation ±0.5 dB, 25°C
|
| Distance range (single mode) | 0.5, 1, 2.5, 5, 10, 25, 50, 100, 200, 300 km |
| Sampling points |
Up to 150,001
Either high density value is selected depending on distance range
|
| Sampling resolution | 0.05 m to 60 m |
| Reflectance accuracy (single mode) |
±2 dB
When measuring the non-connected end of an approximately 25 km length fiber, distance range: 50 km, pulse width: 2 μs
|
| Distance accuracy |
±1 m ±3 × measurement distance × 10^-5 ± marker resolution
Excluding IOR uncertainty
|
| Loss measurement accuracy (linearity) | ±0.05 dB/dB or ±0.1 dB (whichever is greater) |
| Vertical scale | 0.1, 0.2, 0.5, 1.0, 2.0, 5.0, 10.0 dB/div |
| IOR setting | 1.300000 to 1.700000 (0.000001 steps) |
| Units | km, m, kft, ft, mi |
| Real time sweep |
0.15 sec.
Resolution: Low Density
|
| OTDR trace format | Telcordia universal. SOR, issue 2 (SR-4731) |
| Laser safety |
IEC 60825-1: 2014 CLASS 1
Complies with 21CFR1040.10 and 1040.11 except for conformance with IEC 60825-1 Ed.3., as described in Laser Notice No. 56, dated May 8, 2014
|
| Operation | Auto or manual operation, displayed in table format |
|---|---|
| Pass/Fail threshold: reflective and non-reflective events |
0.01 to 9.99 dB (0.01-dB steps)
User defined
|
| Pass/Fail threshold: reflectance |
70.0 to 20.0 dB (0.1-dB steps)
User defined
|
| Pass/Fail threshold: fiber end/break |
1 to 99 dB (1-dB steps)
User defined
|
| Number of detected events | up to 99 |
| Loss modes | 2-point loss, dB/km, 2-point LSA, splice loss, ORL |
| Averaging modes | Timed (1 to 3600 s) |
| Wavelength |
Same as OTDR
CW, 25°C
|
|---|---|
| Spectral width |
≤5 nm (1310 nm), ≤10 nm (1550 nm)
CW, 25°C
|
| Wavelength accuracy |
±30 nm
1310/1550 nm; CW, 25°C
|
| Output power |
–5 ±1.5 dBm
CW, 25°C
|
| Output stability |
≤0.1 dB
CW, –10°C to 50°C (±1°C), difference between max/min values over 1 minute, SM fiber 2 m
|
| Modes of operation |
CW, 270 Hz, 1 kHz, 2 kHz
Modulation +1.5% with 10 minute warm up
|
| Maximum input |
+10 dBm
Not available if Option 004, 005 or 007 is ordered
|
|---|---|
| Measurement range | –50 to –5 dBm |
| Accuracy |
±6.5%
CW input, –20 dBm at 1550 nm, 23°C ±2, Anritsu reference single mode fiber with FC/UPC connector
|
| Setting wavelengths |
1310, 1550, 1625, 1650 nm
Options 053, 055, 057, 063
|
| Features | Store reference, loss table |
|
Measurement range
MT9085A-004
|
–50 to +23 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones
|
|---|---|
|
Measurement range
MT9085A-005
|
–43 to +30 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones
|
|
Measurement range
MT9085A-007
|
–67 to +6 dBm (CW, 1310 nm)
–60 to +3 dBm at 850 nm; peak power, subtract 3 dB for modulated tones
|
| Modulation | CW, 270 Hz, 1 kHz, 2 kHz |
| Operating temperature and humidity | 0°C to +50°C, <80% (non-condensing) |
|
Central wavelength
MT9085A-002
|
650 nm±15 nm (at 25˚C) |
|---|---|
|
Optical output
MT9085A-002
|
0 ±3 dBm (CW) |
|
Optical connector
MT9085A-002
|
2.5 mm universal |
|
Laser safety
MT9085A-002
|
IEC 60825-1: 2014 CLASS 3R |
| Display | 8-inch touch screen TFT-Color LCD |
|---|---|
| Interface |
USB 2.0: Type A × 3 (memory), USB1.1: MicroB × 1 (USB mass storage)
USB power supply is 500 mA
|
| Wireless interface | WLAN via USB adapter connected to USB port |
| Data storage | Internal memory: 1 GB (up to 50,000 traces), External memory (USB): up to 32 GB |
| Languages |
English, Simplified Chinese, Traditional Chinese, French, German, Italian, Korean, Portuguese, Russian, Spanish, Swedish and Japanese
User selectable
|
| Power supply |
12 V(dc), 100 V(ac) to 240 V(ac), 50 Hz/60 Hz
Allowable input voltage range: 90 V to 264 V
|
|---|---|
| Battery type |
Lithium ion
Battery Pack Z0921A, 11.1 V, 4200 mAh
|
| Battery operating time |
12 hours
Typical, backlight Low, sweeping halted at 25˚C; Telcordia GR-196-CORE Issue 2, September 2010
|
| Recharge time | <5 hours (power off) |
| Power consumption | 20 W max (recharging), 4 W standard (low backlight, sweep stopped) |
| Power saving functions | Backlight off: Disable/1 to 99 minutes; Auto shutdown: Disable/1 to 99 minutes |
| Dimensions (without protector) | 270 (W) × 165 (H) × 61 (D) mm, 10.6 × 6.5 × 2.4 inches |
|---|---|
| Mass (without protector) | 1.6 kg without battery, 1.9 kg including battery |
| Dimensions (with protector) |
284 (W) × 200 (H) × 77 (D) mm, 11.2 × 7.9 × 3 inches
Option 010
|
| Mass (with protector) |
2.6 kg including battery
Option 010
|
| Operating temperature and humidity | –10°C to +50°C, <80% (non-condensing) |
|---|---|
| Storage temperature and humidity | –20°C to +60°C, <80% (non-condensing) |
| Vibration | Conforming to MIL-T-28800E Class 3 |
| Ingress protection rating | IEC60529 IP51 |
| Shock |
MIL-T-28800E Style A (46 cm height, 8 corners, 6 faces; 14 drops in total, power off)
Bump: IEC 60068-2-27, JIS C60068-2-27
|
| CE | EMC 2014/30/EU, EN61326-1, EN61000-3-2; LVD 2014/35/EU, EN61010-1; RoHS 2011/65/EU, (EU) 2015/863, EN IEC 63000: 2018 |
| UKCA | EMC S.I. 2016 No.1091, EN 61326-1, EN61000-3-2; LVD S.I. 2016 No.1101, EN 61010-1; RoHS S.I. 2012 No.3032, EN IEC 63000:2018 |
Applications
- Installation and maintenance of optical fiber networks
- Premise fiber networks
- Access network troubleshooting
- Metro networks
- Mobile fronthaul and backhaul
- Drop cable break location
- PON splitter analysis
- Optical loss and power measurement
- Fiber end-face inspection
Included
- Z1991A MT9085 Operation Manual (CD): 1 pc
- W3974AE MT9085 Series Quick Guide: 1 pc
- Z1625A AC adapter: 1 pc
- Line cord: 1 pc
- Z0921A Battery Pack: 1 pc
Options & Accessories
| Option | Description |
|---|---|
| MT9085A-025 | FC-APC Connector — Key width 2.0 mm. Can only connect APC-type optical fiber |
| MT9085A-026 | SC-APC Connector — Can only connect APC-type optical fiber |
| MT9085A-037 | FC Connector |
| MT9085A-038 | ST Connector |
| MT9085A-040 | SC Connector |
| MT9085A-002 | Visual Fault Locator — Visible red light for fiber identification and troubleshooting |
| MT9085A-004 | SMF Optical Power Meter — –50 to +23 dBm |
| MT9085A-005 | SMF High Power Optical Power Meter — –43 to +30 dBm |
| MT9085A-007 | SMF/MMF Optical Power Meter — –67 to +6 dBm |
| MT9085A-010 | Protector — Front Protector B0584A cover supplied with belt as standard |
| G0306C | Video Inspection Probe — X400 magnification fixed. Displays fiber end-face condition on ACCESS Master screen and performs Pass/Fail evaluation |
| W3971AE | MT9085 Series Operation Manual — Printed. Electronic version included on accessory CD Z1991A. |
| W3972AE | MT9085 Series SCPI Remote Control Operation Manual — Printed. Electronic version included on accessory CD Z1991A. |
| B0745A | Softcase |
| B0582A | Soft carrying case — With shoulder strap. Can also accommodate main unit with fitted Option 010 Protector |
| B0583A | Hard transit case — Dimensions 420 (W) × 330 (H) × 148(D) mm |
| B0549 | Hard carrying case |
| B0584A | Front cover — Option 010 Protector cover only |
| Z0921A | Battery Pack — Li-ion Secondary battery, 11.1 V(dc), 4200 mAh |
| Z1632A | Battery Charger — Li-ion battery charger |
| J1295 | Car plug cord |
| J0617B | Replaceable optical connector (FC-PC) — For OTDR port, for option power meter port |
| J0618D | Replaceable optical connector (ST) — For OTDR port, for option power meter port |
| J0618F | Replaceable optical connector (HMS-10/A) — For OTDR port, for option power meter port |
| J0619B | Replaceable optical connector (SC-PC) — For OTDR port, for option power meter port |
| J0739A | Replaceable optical connector (FC-APC) — For OTDR port |
| J1697A | Replaceable optical connector (SC-APC) — For OTDR port |
| J0057 | Optical adapter FC type — FC-FC connector (JJ adapter) |
| J1335A | MU/LC connector adapter — Ferrule connection adapter 2.5 mm → 1.25 mm for visual light source (Option 002 only) |
| MA9005B-37 | For FC connector — For option power meter port (MT9085A/B/C-005) |
| MA9005B-38 | For ST connector — For option power meter port (MT9085A/B/C-005) |
| MA9005B-40 | For SC connector — For option power meter port (MT9085A/B/C-005) |
| LP-FC | FC-PC power meter adapter — For option power meter port (MT9085A/B/C-007) |
| LP-ST | ST-PC power meter adapter — For option power meter port (MT9085A/B/C-007) |
| LP-SC | SC-PC power meter adapter — For option power meter port (MT9085A/B/C-007) |
| J1530A | SC plug in converter (UPC(P)-APC(J)) — Converts main unit SC/UPC connector to SC/APC |
| J1531A | SC plug in converter (APC(P)-UPC(J)) — Converts main unit SC/APC connector to SC/UPC |
| J1532A | FC plug in converter (UPC(P)-APC(J)) — Converts main unit FC/UPC connector to FC/APC |
| J1533A | FC plug in converter (APC(P)-UPC(J)) — Converts main unit FC/APC connector to FC/UPC |
| J1534A | LC-SC Plug-in Converter (for SM, SC(P)-LC(J)) — Converts main unit SC connector to LC (SMF only) |
| J1535A | LC-SC Plug-in Converter (for MM, SC(P)-LC(J)) — Converts main unit SC connector to LC (MMF 62.5/125 μm only) |
| Z0914A | Ferrule cleaner — 1 pc |
| Z0915A | Replacement reel for ferrule cleaner — 6 pcs for Z0914A |
| Z0284 | Adapter Cleaner — Stick type (200 pcs/set) |
| J1950A | USB-Ethernet converter — For remote GUI connection |
| NETWORKS | NETWORKS PC analysis software — OTDR waveform analysis of .sor files and report creation on a Windows PC |