ACCESS Master MT9085A-063 Handheld OTDR, 1310/1550 nm SM and 850/1300 nm MM
Standard-dynamic-range handheld all-in-one OTDR for single mode and multimode fiber at 1310/1550 nm and 850/1300 nm with 8-inch touchscreen.
- Wavelength
- 1310/1550 nm ±25 nm, 850/1300 nm ±30 nm
- Fiber type
- HYBRID (SMF/MMF)
- HR/ER mode
- HR: High Resolution mode for Short dead zone; ER: Enhanced Range mode for PON measurement
- Pulse width (SMF)
- 3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns
Overview
The ACCESS Master MT9085A-063 is the hybrid single mode/multimode model of the Anritsu MT9085 series standard dynamic range line. It is a compact handheld all-in-one tester for optical pulse tests (OTDR), optical loss and power measurements, and optical fiber end-face inspection, and is intended for installation and maintenance (I&M) of both SMF and MMF links.
The OTDR port supports 1310/1550 nm on single mode fiber and 850/1300 nm on multimode fiber. The Fiber Visualizer function displays fiber events such as splices, connectors and splitters as schematic icons with loss and reflectance Pass/Fail evaluation, while manual analysis remains available through the rotary knob, dedicated hard keys and four-marker operation. Two realtime sweep modes (high-speed and high S/N) help locate fiber bends and check connections while monitoring the waveform.
A stabilized light source and an optical power meter are built in through the OTDR port as standard. Optional power meter ports, a visual fault locator and an external Video Inspection Probe (G0306C) extend the unit to optical loss testing, visual fault location and IEC61300-3-35 end-face inspection.
The instrument has an 8-inch color LCD touchscreen that can be operated with work gloves, 1 GB of internal memory for up to 50,000 traces, Telcordia SR-4731 trace format support, and data transfer via USB memory, USB cable, WLAN (USB adapter) or Ethernet (USB-Ethernet converter). The unit weighs 1.9 kg including battery and provides 12 hours of battery operation.
Key Features
- 8-inch LCD touchscreen with easy visibility even in direct sunlight
- Operation via touchscreen, rotary knob and dedicated hard keys
- Hybrid OTDR port for single mode (1310/1550 nm) and multimode (850/1300 nm) fiber
- Fiber Visualizer function for simple fiber path analysis with schematic event icons and Pass/Fail evaluation
- High-speed and high S/N real-time sweep modes for fast fiber bend location
- Identification of each splitter event and up to 1 × 128 branches
- Built-in stabilized light source and optical power meter as standard
- Optional optical power meter, visual fault locator and external fiberscope (VIP)
- Optical fiber end-face inspection with automatic Pass/Fail evaluation per IEC61300-3-35
- Cable Certification Test function with automatic Pass/Fail evaluation and PDF report output
- Installation Test function for automatic measurement of multiple fibers
- Bi-directional waveform analysis function
- Optical communications (live fiber) check and connection check functions
- Scenario Manager Lite for automated testing without a PC
- Remote control via web browser GUI and remote commands
- Password protection function
- Telcordia SR-4731 trace format support
Specifications
| Wavelength |
1310/1550 nm ±25 nm, 850/1300 nm ±30 nm
25°C, Pulse width: 1 μs (all except 850 nm, 1300 nm), 850 nm/1300 nm: 100 ns
|
|---|---|
| Fiber type |
HYBRID (SMF/MMF)
At measurement of 50 μm/125 μm MM Fiber, the dynamic range drops by about 3.0 dB
|
| HR/ER mode | HR: High Resolution mode for Short dead zone; ER: Enhanced Range mode for PON measurement |
| Pulse width (SMF) | 3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns |
| Pulse width (MMF) |
3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000 ns
850 nm: Does not support 1000, 2000, 4000 ns
|
| Dynamic range (1310/1550 nm SM) |
39/37.5 dB
Typical; subtract 1 dB for guarantee. Pulse width: 20 μs, Distance range: 100 km, Averaging: 180 sec., SNR = 1, 25°C
|
| Dynamic range (850/1300 nm MM) |
29/28 dB
Typical; subtract 1 dB for guarantee. Pulse width: 500 ns (850 nm), 4 μs (1300 nm) at Distance range: 25 km, Averaging: 180 sec., SNR = 1, 25°C
|
| Dead zone (Fresnel) |
≤1 m, 0.8 m (typ.)
IOR = 1.500000; Pulse width: 3 ns, Return loss: 40 dB, 25°C
|
| Dead zone (Backscatter), 1310/1550 nm SM |
≤5/5.5 m
IOR = 1.500000; Pulse width 10 ns, return loss 55 dB, Deviation ±0.5 dB, 25°C
|
| Dead zone (Backscatter), 850/1300 nm MM |
≤4/5 m (3/4 m typ.)
IOR = 1.500000; Pulse width 3 ns, return loss 40 dB, Deviation ±0.5 dB, 25°C
|
| Laser safety |
IEC 60825-1: 2014 CLASS 1
Complies with 21CFR1040.10 and 1040.11 except for conformance with IEC 60825-1 Ed.3., as described in Laser Notice No. 56, dated May 8, 2014
|
| Distance range (single mode) | 0.5, 1, 2.5, 5, 10, 25, 50, 100, 200, 300 km |
|---|---|
| Distance range (multimode) | 0.5, 1, 2.5, 5, 10, 25, 50, 100 km |
| Sampling points |
Up to 150,001
Either high density value is selected depending on distance range
|
| Sampling resolution | 0.05 m to 60 m |
| Reflectance accuracy (single mode) |
±2 dB
When measuring the non-connected end of an approximately 25 km length fiber, Distance range: 50 km, Pulse width: 2 μs
|
| Reflectance accuracy (multimode) |
±4 dB
When measuring the non-connected end of an approximately 4.5 km length fiber, Distance range: 10 km, Pulse width: 100 ns
|
| Distance accuracy |
±1 m ±3 × measurement distance × 10^-5 ± marker resolution
Excluding IOR uncertainty
|
| Loss measurement accuracy (linearity) | ±0.05 dB/dB or ±0.1 dB (whichever is greater) |
| Vertical scale | 0.1, 0.2, 0.5, 1.0, 2.0, 5.0, 10.0 dB/div |
| IOR setting | 1.300000 to 1.700000 (0.000001 steps) |
| Units | km, m, kft, ft, mi |
| Real time sweep |
0.15 sec.
Resolution: Low Density
|
| Loss modes | 2-point loss, dB/km, 2-point LSA, splice loss, ORL |
| Averaging modes | Timed (1 to 3600 s) |
| OTDR trace format | Telcordia universal. SOR, issue 2 (SR-4731) |
| Operation | Auto or manual operation, displayed in table format |
|---|---|
| Pass/Fail threshold: reflective and non-reflective events |
0.01 to 9.99 dB (0.01-dB steps)
User defined
|
| Pass/Fail threshold: reflectance |
70.0 to 20.0 dB (0.1-dB steps)
User defined
|
| Pass/Fail threshold: fiber end/break |
1 to 99 dB (1-dB steps)
User defined
|
| Number of detected events | up to 99 |
| PON splitter analysis | Up to 1 × 128 branches |
| Wavelength |
Same as OTDR
CW, 25°C
|
|---|---|
| Spectral width |
≤5 nm (1310 nm), ≤10 nm (850/1300/1490/1550/1625 nm)
CW, 25°C
|
| Wavelength accuracy |
850/1300/1310/1490/1550/1625 nm: ±30 nm
CW, 25°C
|
| Output power |
–5 ±1.5 dBm
CW, 25°C
|
| Output stability |
≤0.1 dB
CW, –10°C to 50°C (±1°C) difference between max/min. values over 1 minute, SM fiber 2 m
|
| Modes of operation | CW, 270 Hz, 1 kHz, 2 kHz |
| Optical ports with light source | 1310/1550 nm SM and 850/1300 nm MM |
| Maximum input | +10 dBm |
|---|---|
| Measurement range | –50 to –5 dBm |
| Accuracy |
±6.5%
CW input, –20 dBm at 1550 nm, 23°C ±2, Using Anritsu's reference single mode fiber with FC/UPC connector
|
| Setting wavelengths |
1310, 1550, 1625, 1650 nm
Options 053, 055, 057, 063
|
| Optical port with power meter |
1310/1550 nm SM
Not available on the 850/1300 nm MM port; not available if Option 004, 005 or 007 is ordered
|
| Features | Store reference, loss table |
|
Measurement range
MT9085A-007
|
–67 to +6 dBm (CW, 1310 nm)
Peak power, subtract 3 dB for modulated tones; –60 to +3 dBm @850 nm
|
|---|---|
|
Measurement range
MT9085A-004
|
–50 to +23 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones
|
|
Measurement range
MT9085A-005
|
–43 to +30 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones
|
|
Wavelength range
MT9085A-007
|
800 nm to 1700 nm |
|
Wavelength range
MT9085A-004, MT9085A-005
|
1200 nm to 1700 nm |
|
Modulation
MT9085A-004, MT9085A-005, MT9085A-007
|
CW, 270 Hz, 1 kHz, 2 kHz |
|
Operating temperature and humidity
MT9085A-004, MT9085A-005, MT9085A-007
|
0°C to +50°C, <80% (non-condensing) |
|
Central wavelength
MT9085A-002
|
650 nm±15 nm (at 25˚C) |
|---|---|
|
Optical output
MT9085A-002
|
0 ±3 dBm (CW) |
|
Output optical fiber
MT9085A-002
|
10 μm/125 μm, SMF (ITU-T G.652) |
|
Optical connector
MT9085A-002
|
2.5 mm universal |
|
Laser safety
MT9085A-002
|
IEC 60825-1: 2014 CLASS 3R |
| Display | 8-inch touch screen TFT-Color LCD |
|---|---|
| Interface |
USB 2.0: Type A × 3 (memory), USB1.1: MicroB × 1 (USB mass storage)
USB power supply is 500 mA
|
| Wireless interface | WLAN via USB adapter connected to USB port |
| Data storage | Internal memory: 1 GB (up to 50,000 traces), External memory (USB): up to 32 GB |
| Languages |
English, Simplified Chinese, Traditional Chinese, French, German, Italian, Korean, Portuguese, Russian, Spanish, Swedish and Japanese
User selectable
|
| Power supply |
12 V(dc), 100 V(ac) to 240 V(ac), 50 Hz/60 Hz
Allowable input voltage range: 90 V to 264 V
|
|---|---|
| Battery type |
Lithium ion
Battery Pack Z0921A: 11.1 V, 4200 mAh
|
| Battery operating time |
12 hours
Telcordia GR-196-CORE Issue 2, September 2010; typical, backlight Low, sweeping halted at 25˚C
|
| Recharge time | <5 hours (power off) |
| Power consumption | 20 W max (recharging), 4 W standard (low backlight, sweep stopped) |
| Power saving functions | Backlight off: Disable/1 to 99 minutes; Auto shutdown: Disable/1 to 99 minutes |
| Dimensions (without protector) | 270 (W) × 165 (H) × 61 (D) mm, 10.6 × 6.5 × 2.4 inches |
|---|---|
| Mass (without protector) | 1.6 kg without battery, 1.9 kg including battery |
| Dimensions (with protector, option 010) | 284 (W) × 200 (H) × 77 (D) mm, 11.2 × 7.9 × 3 inches |
| Mass (with protector, option 010) | 2.6 kg including battery |
| Operating temperature and humidity | –10°C to +50°C, <80% (non-condensing) |
|---|---|
| Storage temperature and humidity | –20°C to +60°C, <80% (non-condensing) |
| Vibration | Conforming to MIL-T-28800E Class 3 |
| Ingress protection rating | IEC60529 IP51 |
| Shock |
MIL-T-28800E Style A (46 cm height, 8 corners, 6 faces; 14 drops in total, power off)
Bump: IEC 60068-2-27, JIS C60068-2-27
|
| Shock-on-desk | MIL-T-28800E (45° angle or 100 mm lifted edge, 4 drops in total, power on) |
| CE | EMC 2014/30/EU, EN61326-1, EN61000-3-2; LVD 2014/35/EU, EN61010-1; RoHS 2011/65/EU, (EU) 2015/863, EN IEC 63000: 2018 |
| UKCA | EMC S.I. 2016 No.1091, EN 61326-1, EN61000-3-2; LVD S.I. 2016 No.1101, EN 61010-1; RoHS S.I. 2012 No.3032, EN IEC 63000:2018 |
Applications
- Installation and maintenance of single mode and multimode fiber
- Trunk fiber I&M (Core, Metro, Mobile Fronthaul, Mobile Backhaul)
- Access network troubleshooting
- Drop cable break location
- PON splitter analysis
- Optical power and loss measurement
- Optical fiber end-face inspection
- Cable certification testing
Included
- Z1991A MT9085 Operation Manual (CD): 1 pc
- W3974AE MT9085 Series Quick Guide: 1 pc
- Z1625A AC adapter: 1 pc
- Line cord: 1 pc
- Z0921A Battery Pack: 1 pc
Options & Accessories
| Option | Description |
|---|---|
| MT9085A-025 | FC-APC Connector Key width 2.0 mm — Can only connect APC-type optical fiber |
| MT9085A-026 | SC-APC Connector — Can only connect APC-type optical fiber |
| MT9085A-037 | FC Connector |
| MT9085A-038 | ST Connector |
| MT9085A-039 | DIN47256 Connector |
| MT9085A-040 | SC Connector |
| MT9085A-002 | Visual Fault Locator — Visual light source, 650 nm, for locating fiber breaks |
| MT9085A-004 | SMF Optical Power Meter — –50 to +23 dBm |
| MT9085A-005 | SMF High Power Optical Power Meter — –43 to +30 dBm |
| MT9085A-007 | SMF/MMF Optical Power Meter — –67 to +6 dBm |
| MT9085A-010 | Protector — Front Protector B0584A cover supplied with belt as standard |
| G0306C | Video Inspection Probe — X400 magnification fixed. Displays fiber end-face condition on ACCESS Master screen and performs Pass/Fail evaluation |
| W3971AE | MT9085 Series Operation Manual — Printed. Electronic version included on accessory CD Z1991A. |
| W3972AE | MT9085 Series SCPI Remote Control Operation Manual — Printed. Electronic version included on accessory CD Z1991A. |
| B0745A | Softcase |
| B0582A | Soft carrying case — With shoulder strap. Can also accommodate main unit with fitted Option 010 Protector |
| B0583A | Hard transit case — Dimensions 420 (W) × 330 (H) × 148(D) mm |
| B0549 | Hard carrying case |
| B0584A | Front cover — Option 010 Protector cover only |
| Z0921A | Battery Pack — Li-ion Secondary battery, 11.1 V(dc), 4200 mAh |
| Z1632A | Battery Charger — Li-ion battery charger |
| J1295 | Car plug cord |
| J0617B | Replaceable optical connector (FC-PC) — For OTDR port, For option power meter port |
| J0618D | Replaceable optical connector (ST) — For OTDR port, For option power meter port |
| J0618F | Replaceable optical connector (HMS-10/A) — For OTDR port, For option power meter port |
| J0619B | Replaceable optical connector (SC-PC) — For OTDR port, For option power meter port |
| J0739A | Replaceable optical connector (FC-APC) — For OTDR port |
| J1697A | Replaceable optical connector (SC-APC) — For OTDR port |
| J0057 | Optical adapter FC type — FC-FC connector (JJ adapter) |
| J1335A | MU/LC connector adapter — Ferrule connection adapter 2.5 mm → 1.25 mm for visual light source (Option 002 only) |
| MA9005B-37 | For FC connector — For option power meter port (MT9085A/B/C-005) |
| MA9005B-38 | For ST connector — For option power meter port (MT9085A/B/C-005) |
| MA9005B-40 | For SC connector — For option power meter port (MT9085A/B/C-005) |
| LP-FC | FC-PC power meter adapter — For option power meter port (MT9085A/B/C-007) |
| LP-ST | ST-PC power meter adapter — For option power meter port (MT9085A/B/C-007) |
| LP-SC | SC-PC power meter adapter — For option power meter port (MT9085A/B/C-007) |
| J1530A | SC plug in converter (UPC(P)-APC(J)) — Converts main unit SC/UPC connector to SC/APC |
| J1531A | SC plug in converter (APC(P)-UPC(J)) — Converts main unit SC/APC connector to SC/UPC |
| J1532A | FC plug in converter (UPC(P)-APC(J)) — Converts main unit FC/UPC connector to FC/APC |
| J1533A | FC plug in converter (APC(P)-UPC(J)) — Converts main unit FC/APC connector to FC/UPC |
| J1534A | LC-SC Plug-in Converter (for SM, SC(P)-LC(J)) — Converts main unit SC connector to LC (SMF only) |
| J1535A | LC-SC Plug-in Converter (for MM, SC(P)-LC(J)) — Converts main unit SC connector to LC (MMF 62.5/125 μm only) |
| Z0914A | Ferrule cleaner — 1 pc |
| Z0915A | Replacement reel for ferrule cleaner — 6 pcs for Z0914A |
| Z0284 | Adapter Cleaner — Stick type (200 pcs/set) |
| J1950A | USB-Ethernet converter — For remote GUI connection |
| NETWORKS | NETWORKS OTDR analysis PC software — Waveform analysis and report creation for OTDR data (.sor) on a Windows PC; sold separately |