Wavelength
1310/1550 nm ±25 nm, 1645 nm to 1655 nm
Fiber type
Single Mode (SMF) 10/125 μm ITU-T G.652
Pulse width
3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns
Dynamic range (1310/1550/1650 nm)
42/41/35 dB

Overview

The ACCESS Master MT9085B-055 is a member of the Anritsu MT9085 series of compact handheld all-in-one fiber testers. It is an Enhanced (Performance class) model with single-mode OTDR wavelengths of 1310/1550 nm and 1650 nm. The 1650 nm wavelength uses a built-in filter, allowing maintenance testing of in-service live circuits.

The MT9085 series combines optical pulse testing (OTDR), optical power and loss measurement and, with an external fiberscope option, optical fiber end-face inspection in one unit. Applications range from installation and maintenance of trunk fibers in core, metro, mobile fronthaul and mobile backhaul networks to troubleshooting access networks, such as breaks in drop cables.

Operation

The instrument has an 8-inch color LCD touchscreen together with hard keys and a rotary knob carried over from previous ACCESS Master models. The Fiber Visualizer function displays events such as splices, connectors and splitters as schematic icons with loss and reflectance Pass/Fail results. Two realtime sweep modes, high-speed and high S/N, help locate fiber bends and check connections while monitoring the waveform.

Measurement functions

A stabilized light source and an optical power meter are built in and use the OTDR port. Separate-port power meter options enable optical loss testing (OLTS). Other options include a visual fault locator and the G0306C Video Inspection Probe for end-face inspection to IEC61300-3-35. An Optical Communications Check function detects live traffic on the fiber and stops OTDR measurement to avoid disturbing the circuit.

Data handling

Results can be saved as original data files (.sor, .vipi), .csv files, screen captures or PDF reports. Files can be transferred over USB memory, USB cable, or WLAN and Ethernet through USB adapters. Remote control is available through a web browser GUI or remote commands.

Key Features

  • Built-in filter at 1650 nm for maintenance of in-service live circuits
  • 8-inch LCD touchscreen with easy visibility even in direct sunlight
  • LCD touchscreen, rotary knob and dedicated hard keys for operation
  • Pressure-sensitive touchscreen supports input without removing work gloves
  • Fiber Visualizer function for simple fiber path analysis with Pass/Fail evaluation
  • High-speed and high S/N real-time sweep modes for fiber bend location
  • Identification of each splitter event and up to 1 × 128 branches
  • Built-in stabilized light source and optical power meter through the OTDR port
  • Optional visual fault locator and separate-port optical power meters
  • Optical fiber end-face inspection using external G0306C fiberscope option
  • Optical Communications Check function detects live traffic before OTDR testing
  • Connection Check function verifies OTDR-to-fiber connection quality
  • Bi-directional measurement analysis
  • Installation Test function for automatic measurement of multiple fibers
  • Cable Certification Test function with automatic Pass/Fail to IEC/ISO standards
  • Scenario Manager Lite for automated test execution without a PC
  • Telcordia SR-4731 trace format support
  • 1 GB internal memory for up to 50,000 traces
  • 12-hour battery operation
  • Password protection function
  • Remote control via web browser GUI and remote commands

Specifications

OTDR
Wavelength 1310/1550 nm ±25 nm, 1645 nm to 1655 nm
25°C, pulse width 1 μs
Fiber type Single Mode (SMF) 10/125 μm ITU-T G.652
Pulse width 3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns
Dynamic range (1310/1550/1650 nm) 42/41/35 dB
Typical; subtract 1 dB for guarantee. Pulse width 20 μs, distance range 100 km, averaging 180 sec., SNR = 1, 25°C. At 1650 nm: with background light, 1310/1550 nm, –19 dBm CW light. The 2020 Product Introduction lists 41/41/35 dB
Dead zone (Fresnel) ≤1 m, 0.8 m (typ.)
IOR = 1.500000, pulse width 3 ns, return loss 40 dB, 25°C
Dead zone (Backscatter) ≤5/5.5/6.5 m
IOR = 1.500000, pulse width 10 ns, return loss 55 dB, deviation ±0.5 dB, 25°C
Mode HR/ER
HR: High Resolution mode for short dead zone; ER: Enhanced Range mode for PON measurement
Laser safety IEC 60825-1: 2014 CLASS 1
Complies with 21CFR1040.10 and 1040.11 except for conformance with IEC 60825-1 Ed.3., as described in Laser Notice No. 56, dated May 8, 2014
Sampling points Up to 150,001
Sampling resolution 0.05 m to 60 m
Reflectance accuracy Single mode: ±2 dB
When measuring the non-connected end of an approximately 25 km length fiber, distance range 50 km, pulse width 2 μs
Distance accuracy ±1 m ±3 × measurement distance × 10^-5 ± marker resolution
Excluding IOR uncertainty
Loss measurement accuracy (linearity) ±0.05 dB/dB or ±0.1 dB (whichever is greater)
Distance range Single mode: 0.5, 1, 2.5, 5, 10, 25, 50, 100, 200, 300 km
Vertical scale 0.1, 0.2, 0.5, 1.0, 2.0, 5.0, 10.0 dB/div
IOR setting 1.300000 to 1.700000 (0.000001 steps)
Units km, m, kft, ft, mi
Real time sweep 0.15 sec.
Resolution: Low Density
OTDR trace format Telcordia universal. SOR, issue 2 (SR-4731)
Fiber Event Analysis
Operation Auto or manual operation, displayed in table format
Reflective and non-reflective event threshold 0.01 to 9.99 dB (0.01-dB steps)
User defined Pass/Fail threshold
Reflectance threshold 70.0 to 20.0 dB (0.1-dB steps)
User defined Pass/Fail threshold
Fiber end/break threshold 1 to 99 dB (1-dB steps)
User defined Pass/Fail threshold
Number of detected events up to 99
Loss modes 2-point loss, dB/km, 2-point LSA, splice loss, ORL
Averaging modes Timed (1 to 3600 s)
Live fiber detect Verifies presence of communication light in optical fiber
Connection check Automatic check of OTDR to FUT connection quality
Light Source (Standard, through OTDR port)
Wavelength Same as OTDR
CW, 25°C
Spectral width ≤5 nm (1310 nm), ≤10 nm (1550 nm), ≤3 nm (1650 nm)
CW, 25°C
Wavelength accuracy 1310/1550 nm: ±30 nm; 1650 nm: ±5 nm
CW, 25°C
Output power –5 ±1.5 dBm
CW, 25°C
Output stability ≤0.1 dB
CW, –10°C to 50°C (±1°C), difference between max/min values over 1 minute, SM fiber 2 m
Modes of operation CW, 270 Hz, 1 kHz, 2 kHz
Modulation +1.5% with 10 minute warm up
Power Meter (Standard, through OTDR port)
Maximum input +10 dBm
Standard integrated power meter is not available if Option 004, 005 or 007 is ordered
Measurement range –50 to –5 dBm
Accuracy ±6.5%
CW input, –20 dBm at 1550 nm, 23°C ±2, using Anritsu's reference single mode fiber with FC/UPC connector
Setting wavelengths 1310, 1550, 1625, 1650 nm
Options 053, 055, 057, 063
Features Store reference, loss table
Loss Test Set Power Meters (Optional)
Measurement range
MT9085A/B/C-007
–67 to +6 dBm (CW, 1310 nm)
Peak power, subtract 3 dB for modulated tones
Measurement range
MT9085A/B/C-004
–50 to +23 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones
Measurement range
MT9085A/B/C-005
–43 to +30 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones
Wavelength range
MT9085A/B/C-007
800 nm to 1700 nm
Modulation CW, 270 Hz, 1 kHz, 2 kHz
Operating temperature and humidity 0°C to +50°C, <80% (non-condensing)
Visual Light Source (Option 002)
Central wavelength
MT9085A/B/C-002
650 nm±15 nm (at 25˚C)
Optical output
MT9085A/B/C-002
0 ±3 dBm (CW)
Output optical fiber
MT9085A/B/C-002
10 μm/125 μm, SMF (ITU-T G.652)
Optical connector
MT9085A/B/C-002
2.5 mm universal
Laser safety
MT9085A/B/C-002
IEC 60825-1: 2014 CLASS 3R
General
Dimensions (without protector) 270 (W) × 165 (H) × 61 (D) mm, 10.6 × 6.5 × 2.4 inches
Mass (without protector) 1.6 kg without battery, 1.9 kg including battery
Dimensions (with protector, option 010) 284 (W) × 200 (H) × 77 (D) mm, 11.2 × 7.9 × 3 inches
Mass (with protector, option 010) 2.6 kg including battery
Display 8-inch touch screen TFT-Color LCD
Interface USB 2.0: Type A × 3 (memory), USB1.1: MicroB × 1 (USB mass storage)
USB power supply is 500 mA
Wireless interface WLAN via USB adapter connected to USB port
Data storage Internal memory: 1 GB (up to 50,000 traces), External memory (USB): up to 32 GB
Languages English, Simplified Chinese, Traditional Chinese, French, German, Italian, Korean, Portuguese, Russian, Spanish, Swedish and Japanese
User selectable
Power
Power supply 12 V(dc), 100 V(ac) to 240 V(ac), Allowable input voltage range: 90 V to 264 V, 50 Hz/60 Hz
Battery type Lithium ion
Battery operating time 12 hours
Telcordia GR-196-CORE Issue 2, September 2010; typical, backlight Low, sweeping halted at 25˚C
Recharge time <5 hours (power off)
Power consumption 20 W max (recharging), 4 W standard (low backlight, sweep stopped)
Power saving functions Backlight off: Disable/1 to 99 minutes; Auto shutdown: Disable/1 to 99 minutes
Battery pack Z0921A 11.1 V, 4200 mAh
53 (W) × 19 (H) × 215 (D) mm, 330 g (typ.)
AC adapter Z1625A rated DC output 12 V(dc), 5 A
Rated AC input 100 V(ac) to 240 V(ac), 50 Hz/60 Hz
Environmental
Operating temperature and humidity –10°C to +50°C, <80% (non-condensing)
Storage temperature and humidity –20°C to +60°C, <80% (non-condensing)
Vibration Conforming to MIL-T-28800E Class 3
Ingress protection rating IEC60529 IP51
Shock MIL-T-28800E Style A (46 cm height, 8 corners, 6 faces; 14 drops in total, power off)
Bump: IEC 60068-2-27, JIS C60068-2-27
Shock-on-desk MIL-T-28800E (45° angle or 100 mm lifted edge, 4 drops in total, power on)
CE EMC 2014/30/EU, EN61326-1, EN61000-3-2; LVD 2014/35/EU, EN61010-1; RoHS 2011/65/EU, (EU) 2015/863, EN IEC 63000: 2018
UKCA EMC S.I. 2016 No.1091, EN 61326-1, EN61000-3-2; LVD S.I. 2016 No.1101, EN 61010-1; RoHS S.I. 2012 No.3032, EN IEC 63000:2018

Applications

  • Installation and maintenance of trunk fibers
  • Core and metro networks
  • Mobile fronthaul and backhaul
  • Access network troubleshooting
  • Drop cable break location
  • In-service live circuit maintenance
  • PON-based FTTx
  • Long haul networks
  • Base station installation and maintenance

Included

  • Z1991A MT9085 Operation Manual (CD)
  • W3974AE MT9085 Series Quick Guide
  • Z1625A AC adapter
  • Line cord
  • Z0921A Battery Pack

Options & Accessories

Option Description
MT9085A/B/C-025 FC-APC Connector Key width 2.0 mm — Can only connect APC-type optical fiber
MT9085A/B/C-026 SC-APC Connector — Can only connect APC-type optical fiber
MT9085A/B/C-037 FC Connector
MT9085A/B/C-038 ST Connector
MT9085A/B/C-039 DIN47256 Connector
MT9085A/B/C-040 SC Connector
MT9085A/B/C-002 Visual Fault Locator
MT9085A/B/C-004 SMF Optical Power Meter — –50 to +23 dBm
MT9085A/B/C-005 SMF High Power Optical Power Meter — –43 to +30 dBm
MT9085A/B/C-007 SMF/MMF Optical Power Meter — –67 to +6 dBm
MT9085A/B/C-010 Protector — Front Protector B0584A cover supplied with belt as standard
G0306C Video Inspection Probe — X400 magnification fixed. Displays fiber end-face condition on ACCESS Master screen and performs Pass/Fail evaluation
W3971AE MT9085 Series Operation Manual — Printed. Electronic version included on accessory CD Z1991A.
W3972AE MT9085 Series SCPI Remote Control Operation Manual — Printed. Electronic version included on accessory CD Z1991A.
B0745A Softcase
B0582A Soft carrying case — With shoulder strap. Can also accommodate main unit with fitted Option 010 Protector
B0583A Hard transit case — Dimensions 420 (W) × 330 (H) × 148(D) mm
B0549 Hard carrying case
B0584A Front cover — Option 010 Protector cover only
Z0921A Battery Pack — Li-ion Secondary battery, 11.1 V(dc), 4200 mAh
Z1632A Battery Charger — Li-ion battery charger
J1295 Car plug cord
J0617B Replaceable optical connector (FC-PC) — For OTDR port, for option power meter port
J0618D Replaceable optical connector (ST) — For OTDR port, for option power meter port
J0618F Replaceable optical connector (HMS-10/A) — For OTDR port, for option power meter port
J0619B Replaceable optical connector (SC-PC) — For OTDR port, for option power meter port
J0739A Replaceable optical connector (FC-APC) — For OTDR port
J1697A Replaceable optical connector (SC-APC) — For OTDR port
J0057 Optical adapter FC type — FC-FC connector (JJ adapter)
J1335A MU/LC connector adapter — Ferrule connection adapter 2.5 mm → 1.25 mm for visual light source (Option 002 only)
MA9005B-37 For FC connector — For option power meter port (MT9085A/B/C-005)
MA9005B-38 For ST connector — For option power meter port (MT9085A/B/C-005)
MA9005B-40 For SC connector — For option power meter port (MT9085A/B/C-005)
LP-FC FC-PC power meter adapter — For option power meter port (MT9085A/B/C-007)
LP-ST ST-PC power meter adapter — For option power meter port (MT9085A/B/C-007)
LP-SC SC-PC power meter adapter — For option power meter port (MT9085A/B/C-007)
J1530A SC plug in converter (UPC(P)-APC(J)) — Converts main unit SC/UPC connector to SC/APC
J1531A SC plug in converter (APC(P)-UPC(J)) — Converts main unit SC/APC connector to SC/UPC
J1532A FC plug in converter (UPC(P)-APC(J)) — Converts main unit FC/UPC connector to FC/APC
J1533A FC plug in converter (APC(P)-UPC(J)) — Converts main unit FC/APC connector to FC/UPC
J1534A LC-SC Plug-in Converter (for SM, SC(P)-LC(J)) — Converts main unit SC connector to LC (SMF only)
J1535A LC-SC Plug-in Converter (for MM, SC(P)-LC(J)) — Converts main unit SC connector to LC (MMF 62.5/125 μm only)
Z0914A Ferrule cleaner — 1 pc
Z0915A Replacement reel for ferrule cleaner — 6 pcs for Z0914A
Z0284 Adapter Cleaner — Stick type (200 pcs/set)
J1950A USB-Ethernet converter — For remote GUI connection
NETWORKS NETWORKS PC analysis software — OTDR waveform analysis of .sor files and report creation on Windows PC