Anritsu ACCESS Master MT9085 Series handheld OTDR front view
MT9085C-053

ACCESS Master MT9085C-053 High Performance 1310/1550 nm SMF Handheld OTDR

High-performance handheld OTDR with 1310/1550 nm single-mode wavelengths, 46/46 dB dynamic range, built-in light source and power meter.

Wavelength
1310/1550 nm ±25 nm
Fiber type
Single Mode (SMF) 10/125 μm ITU-T G.652
Pulse width
3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns
Dynamic range (HR mode)
46/46 dB
Datasheet

Overview

The ACCESS Master MT9085C-053 is the High Performance 1310/1550 nm single-mode module option of the Anritsu MT9085 series, a compact handheld all-in-one tester for optical pulse (OTDR) tests, optical loss and power measurements, and optical fiber end-face inspection. Anritsu positions the MT9085C models for long-haul and ultra-long-haul applications, and the -053 option as the standard model for installation and maintenance (I&M).

OTDR measurement

The OTDR measures fiber transmission loss and length and detects events such as splices, connectors, splitters and breaks. The Fiber Visualizer function displays events as schematic icons with distance, loss and reflectance Pass/Fail results. Two realtime sweep modes (high-speed and high S/N) help locate fiber bends, and multi-pulse measurement supports event detection with up to 46 dB dynamic range and a 0.8 m event dead zone. PON splitter analysis covers up to 1 × 128 branches.

Operation

The unit combines an 8-inch color LCD touchscreen with a rotary knob and dedicated hard keys from earlier ACCESS Master models. The pressure-sensitive touchscreen accepts input while wearing work gloves. Manual analysis uses two-point or LSA methods with four markers.

Loss, power and end-face inspection

A stabilized light source and a power meter are built in through the OTDR port; optional dedicated power meter ports enable optical loss test set (OLTS) measurements with one tester. An optional visual fault locator and the external G0306C Video Inspection Probe support break location and IEC61300-3-35 end-face Pass/Fail evaluation. Data can be saved as .sor, .csv or PDF reports and transferred via USB, WLAN or Ethernet adapters.

Key Features

  • 8-inch LCD touchscreen with visibility in direct sunlight
  • LCD touchscreen combined with rotary knob and dedicated hard keys
  • Fiber Visualizer function for simple fiber path analysis
  • High-speed and high S/N real-time sweep modes for locating fiber bends
  • 46 dB dynamic range (typ.) at 1310 and 1550 nm
  • 0.8 m event dead zone (typ.)
  • Identification of each splitter event and up to 1 × 128 branches
  • Built-in stabilized light source and optical power meter as standard
  • Optional visual fault locator and dedicated optical power meter ports
  • Optical fiber end-face inspection with external G0306C Video Inspection Probe
  • Live fiber detection and OTDR connection check
  • Bi-directional measurement analysis
  • Cable Certification Test function with automatic Pass/Fail to IEC/ISO standards
  • Scenario Manager Lite for automated test procedures without a PC
  • Telcordia SR-4731 .sor trace format support
  • 1 GB internal memory for up to 50,000 traces
  • Remote control via web browser GUI or remote commands
  • Password protection function

Specifications

OTDR
Wavelength 1310/1550 nm ±25 nm
25°C, Pulse width: 1 μs
Fiber type Single Mode (SMF) 10/125 μm ITU-T G.652
Pulse width 3, 10, 20, 30, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000 ns
Dynamic range (HR mode) 46/46 dB
Typical; subtract 1 dB for guarantee. Pulse width 20 μs, distance range 100 km, averaging 180 sec., SNR = 1, 25°C
Dynamic range (ER mode) 25/25 dB (Pulse width: 100 ns)
ER Mode, distance range 100 km, averaging 180 sec., SNR = 1, 25°C
Dead zone (Fresnel) ≤1 m, 0.8 m (typ.)
IOR = 1.500000; pulse width 3 ns, return loss 40 dB, 25°C
Dead zone (Backscatter) ≤3.8/4.3 m
IOR = 1.500000; pulse width 10 ns, return loss 55 dB, deviation ±0.5 dB, 25°C
Laser safety IEC 60825-1: 2014 CLASS 1
Complies with 21CFR1040.10 and 1040.11 except for conformance with IEC 60825-1 Ed.3., as described in Laser Notice No. 56, dated May 8, 2014
Sampling points Up to 150,001
Either high density value is selected depending on distance range
Sampling resolution 0.05 m to 60 m
Distance range (single mode) 0.5, 1, 2.5, 5, 10, 25, 50, 100, 200, 300 km
Distance accuracy ±1 m ±3 × measurement distance × 10-5 ± marker resolution
Excluding IOR uncertainty
Loss measurement accuracy (linearity) ±0.05 dB/dB or ±0.1 dB (whichever is greater)
Reflectance accuracy (single mode) ±2 dB
When measuring the non-connected end of an approximately 25 km length fiber, distance range 50 km, pulse width 2 μs
IOR setting 1.300000 to 1.700000 (0.000001 steps)
Vertical scale 0.1, 0.2, 0.5, 1.0, 2.0, 5.0, 10.0 dB/div
Units km, m, kft, ft, mi
Real time sweep 0.15 sec.
Resolution: Low Density
OTDR trace format Telcordia universal. SOR, issue 2 (SR-4731)
Loss modes 2-point loss, dB/km, 2-point LSA, splice loss, ORL
Averaging modes Timed (1 to 3600 s)
Fiber Event Analysis
Operation Auto or manual operation, displayed in table format
Reflective and non-reflective events threshold 0.01 to 9.99 dB (0.01-dB steps)
User defined Pass/Fail threshold
Reflectance threshold 70.0 to 20.0 dB (0.1-dB steps)
User defined Pass/Fail threshold
Fiber end/break threshold 1 to 99 dB (1-dB steps)
User defined Pass/Fail threshold
Number of detected events up to 99
Light Source (Standard)
Wavelength Same as OTDR
Stabilized light source through OTDR port; CW, 25°C
Spectral width ≤5 nm (1310 nm), ≤10 nm (1550 nm)
CW, 25°C
Wavelength accuracy ±30 nm
CW, 25°C
Output power –5 ±1.5 dBm
CW, 25°C
Output stability ≤0.1 dB
CW, –10°C to 50°C (±1°C) difference between max/min. values over 1 minute, SM fiber 2 m
Modes of operation CW, 270 Hz, 1 kHz, 2 kHz
Power Meter (Standard Integrated)
Maximum input +10 dBm
Through OTDR port; not available if Option 004, 005 or 007 is ordered
Measurement range –50 to –5 dBm
Accuracy ±6.5%
CW input, –20 dBm at 1550 nm, 23°C ±2, using Anritsu's reference single mode fiber with FC/UPC connector
Setting wavelengths 1310, 1550, 1625, 1650 nm
Options 053, 055, 057, 063
Features Store reference, loss table
Optional Power Meters
Measurement range
MT9085C-004
–50 to +23 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones
Measurement range
MT9085C-005
–43 to +30 dBm (CW, 1550 nm)
Peak power, subtract 3 dB for modulated tones
Measurement range
MT9085C-007
–67 to +6 dBm (CW, 1310 nm)
–60 to +3 dBm at 850 nm
Visual Light Source (Option 002)
Central wavelength
MT9085C-002
650 nm±15 nm (at 25˚C)
Optical output
MT9085C-002
0 ±3 dBm (CW)
Optical connector
MT9085C-002
2.5 mm universal
Laser safety
MT9085C-002
IEC 60825-1: 2014 CLASS 3R
General
Display 8-inch touch screen TFT-Color LCD
Interface USB 2.0: Type A × 3 (memory), USB1.1: MicroB × 1 (USB mass storage)
USB power supply is 500 mA
Wireless interface WLAN via USB adapter connected to USB port
Data storage Internal memory: 1 GB (up to 50,000 traces), External memory (USB): up to 32 GB
Languages English, Simplified Chinese, Traditional Chinese, French, German, Italian, Korean, Portuguese, Russian, Spanish, Swedish and Japanese
User selectable
Power
Power supply 12 V(dc), 100 V(ac) to 240 V(ac), Allowable input voltage range: 90 V to 264 V, 50 Hz/60 Hz
Battery type Lithium ion
Battery operating time 12 hours
Typical, backlight Low, sweeping halted at 25˚C; Telcordia GR-196-CORE Issue 2, September 2010
Recharge time <5 hours (power off)
Power consumption 20 W max (recharging), 4 W standard (low backlight, sweep stopped)
Physical
Dimensions (without protector) 270 (W) × 165 (H) × 61 (D) mm, 10.6 × 6.5 × 2.4 inches
Mass (without protector) 1.6 kg without battery, 1.9 kg including battery
Dimensions (with protector, option 010) 284 (W) × 200 (H) × 77 (D) mm, 11.2 × 7.9 × 3 inches
Mass (with protector, option 010) 2.6 kg including battery
Environmental
Operating temperature and humidity –10°C to +50°C, <80% (non-condensing)
Storage temperature and humidity –20°C to +60°C, <80% (non-condensing)
Vibration Conforming to MIL-T-28800E Class 3
Ingress protection rating IEC60529 IP51
Shock MIL-T-28800E Style A (46 cm height, 8 corners, 6 faces; 14 drops in total, power off)
Bump: IEC 60068-2-27, JIS C60068-2-27

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • Long-haul fiber installation and maintenance
  • Ultra-long-haul fiber testing
  • Core and metro network I&M
  • Mobile fronthaul and backhaul fiber testing
  • PON and FTTx access network troubleshooting
  • Drop cable break location
  • Optical loss and power measurement
  • Fiber connector end-face inspection

Included

  • Z1991A MT9085 Operation Manual (CD)
  • W3974AE MT9085 Series Quick Guide
  • Z1625A AC adapter
  • Line cord
  • Z0921A Battery Pack

Options & Accessories

Option Description
MT9085C-025 FC-APC Connector — Key width 2.0 mm; can only connect APC-type optical fiber
MT9085C-026 SC-APC Connector — Can only connect APC-type optical fiber
MT9085C-037 FC Connector
MT9085C-038 ST Connector
MT9085C-040 SC Connector
MT9085C-002 Visual Fault Locator — Built-in visual light source option
MT9085C-004 SMF Optical Power Meter — –50 to +23 dBm
MT9085C-005 SMF High Power Optical Power Meter — –43 to +30 dBm
MT9085C-007 SMF/MMF Optical Power Meter — –67 to +6 dBm
MT9085C-010 Protector — Front Protector B0584A cover supplied with belt as standard
G0306C Video Inspection Probe — X400 magnification fixed. Displays fiber end-face condition on ACCESS Master screen and performs Pass/Fail evaluation
W3971AE MT9085 Series Operation Manual — Printed. Electronic version included on accessory CD Z1991A.
W3972AE MT9085 Series SCPI Remote Control Operation Manual — Printed. Electronic version included on accessory CD Z1991A.
B0745A Softcase
B0582A Soft carrying case — With shoulder strap. Can also accommodate main unit with fitted Option 010 Protector
B0583A Hard transit case — Dimensions 420 (W) × 330 (H) × 148(D) mm
B0549 Hard carrying case
B0584A Front cover — Option 010 Protector cover only
Z0921A Battery Pack — Li-ion Secondary battery, 11.1 V(dc), 4200 mAh
Z1632A Battery Charger — Li-ion battery charger
J1295 Car plug cord
J0617B Replaceable optical connector (FC-PC) — For OTDR port, For option power meter port (MT9085A/B/C)
J0618D Replaceable optical connector (ST) — For OTDR port, For option power meter port (MT9085A/B/C)
J0618F Replaceable optical connector (HMS-10/A) — For OTDR port, For option power meter port (MT9085A/B/C)
J0619B Replaceable optical connector (SC-PC) — For OTDR port, For option power meter port (MT9085A/B/C)
J0739A Replaceable optical connector (FC-APC) — For OTDR port (MT9085A/B/C)
J1697A Replaceable optical connector (SC-APC) — For OTDR port (MT9085A/B/C)
J0057 Optical adapter FC type — FC-FC connector (JJ adapter)
J1335A MU/LC connector adapter — Ferrule connection adapter 2.5 mm → 1.25 mm for visual light source (Option 002 only)
MA9005B-37 For FC connector — For option power meter port (MT9085A/B/C-005)
MA9005B-38 For ST connector — For option power meter port (MT9085A/B/C-005)
MA9005B-40 For SC connector — For option power meter port (MT9085A/B/C-005)
LP-FC FC-PC power meter adapter — For option power meter port (MT9085A/B/C-007)
LP-ST ST-PC power meter adapter — For option power meter port (MT9085A/B/C-007)
LP-SC SC-PC power meter adapter — For option power meter port (MT9085A/B/C-007)
J1530A SC plug in converter (UPC(P)-APC(J)) — Converts main unit SC/UPC connector to SC/APC
J1531A SC plug in converter (APC(P)-UPC(J)) — Converts main unit SC/APC connector to SC/UPC
J1532A FC plug in converter (UPC(P)-APC(J)) — Converts main unit FC/UPC connector to FC/APC
J1533A FC plug in converter (APC(P)-UPC(J)) — Converts main unit FC/APC connector to FC/UPC
J1534A LC-SC Plug-in Converter (for SM, SC(P)-LC(J)) — Converts main unit SC connector to LC (SMF only)
J1535A LC-SC Plug-in Converter (for MM, SC(P)-LC(J)) — Converts main unit SC connector to LC (MMF 62.5/125 μm only)
Z0914A Ferrule cleaner — 1 pc
Z0915A Replacement reel for ferrule cleaner — 6 pcs for Z0914A
Z0284 Adapter Cleaner — Stick type (200 pcs/set)
J1950A USB-Ethernet converter — For remote GUI connection
NETWORKS NETWORKS PC analysis software — OTDR waveform analysis of .sor files and report creation on Windows PC

Documents & Resources