VIAVI 4100 Series OTDR module, as used for the E4146A-PC Quad OTDR module
E4146A-PC

4100 Series Quad OTDR Module E4146A-PC Multimode/Singlemode OTDR (PC)

Quad-wavelength 850/1300/1310/1550 nm OTDR module with PC test ports for multimode and singlemode testing on T-BERD/MTS and OneAdvisor 800 platforms.

Weight
0.4 kg (0.88 lb)
Dimensions (w × h × d)
128 x 134 x 40 mm (5 x 5.28 x 1.58 in)
Interchangeable Optical Connectors
FC, SC, LC, and ST
Laser Safety Class (21 CFR)
Class 1
Datasheet

Overview

The VIAVI E4146A-PC is the PC-connector version of the 4100 Series Quad OTDR module. It combines multimode (850/1300 nm) and singlemode (1310/1550 nm) OTDR test ports in one module for users who work with both fiber types, such as installers and contractors, wireless service providers, and enterprise technicians. It is intended for installing, turning up, and maintaining premises and enterprise, access, metro, and wireless fronthaul/backhaul networks.

The module provides up to 26 dB of dynamic range in multimode and up to 37 dB in singlemode, with short event and attenuation dead zones and up to 256,000 acquisition points. An integrated continuous wave light source is accessible through both OTDR ports, so fiber identification and continuity tests can be performed without switching ports. Pass/fail thresholds follow TIA/IEC standards, propagation delay can be measured in multimode per TIA-568-C, and the module certifies Tier 2 premises networks. IEC 61280-4-3 compliant measurements are possible with an external modal controller.

Platforms and software

The module plugs into the T-BERD/MTS-2000, T-BERD/MTS-4000 V2, T-BERD/MTS-5800 and OneAdvisor 800 platforms, and its optical performance is combined with the platform's test and reporting features. Standard features include automatic macrobend detection, a summary results table with pass/fail analysis, the icon-based SmartLink Mapper results view, and FastReport on-board report generation. The module ships with an SC/PC test port adapter for the singlemode port and an SC/PC test port adapter for the multimode port; FC, SC, LC and ST adapters are available.

Key Features

  • Up to 37 dB dynamic range in singlemode and 26 dB in multimode
  • Quad-wavelength version with 850, 1300, 1310, and 1550 nm
  • Integrated continuous wave (CW) light source accessible through both OTDR ports
  • TIA/IEC pass/fail thresholds
  • Propagation delay measurement in multimode (TIA-568-C)
  • Certifies Tier 2 premises networks
  • IEC 61280-4-3-compliant using an external modal controller
  • Automatic macrobend detection
  • Summary results table with pass/fail analysis
  • Smart Link Mapper: simple icon-based OTDR results view
  • FastReport on-board report generation
  • Up to 256,000 data points
  • Interchangeable FC, SC, LC, and ST optical connectors
  • Module portability between T-BERD/MTS-2000, -4000 V2, -5800 and OneAdvisor 800 platforms

Specifications

General
Weight 0.4 kg (0.88 lb)
Typical at 25°C
Dimensions (w × h × d) 128 x 134 x 40 mm (5 x 5.28 x 1.58 in)
Interchangeable Optical Connectors FC, SC, LC, and ST
Laser Safety Class (21 CFR) Class 1
Distance Units Kilometers, feet, and miles
Group Index Range 1.300000 to 1.700000 in 0.00001 steps
Number of Data Points Up to 256,000 data points
Quad OTDR Modules (Typical at 25°C)
Central Wavelength
Multimode 850/1300 nm
850/1300 ±30 nm
Laser at 25°C
Central Wavelength
Singlemode 1310/1550 nm
1310/1550 ±20 nm
Laser at 25°C
Pulse Width
Multimode 850/1300 nm
3 ns to 1 µs
Pulse Width
Singlemode 1310/1550 nm
3 ns to 20 µs
RMS Dynamic Range
Multimode 850/1300 nm
26/24 dB
One-way difference between the extrapolated backscattering level at the start of the fiber and the RMS noise level after 3-minutes averaging at 500 ns in multimode
RMS Dynamic Range
Singlemode 1310/1550 nm
37/35 dB
One-way difference between the extrapolated backscattering level at the start of the fiber and the RMS noise level after 3-minutes averaging at 20 µs in singlemode
Event Dead Zone
Multimode 850/1300 nm
0.55 m
Measured at ±1.5 dB down from the peak of an unsaturated reflective event
Event Dead Zone
Singlemode 1310/1550 nm
0.65 m
Measured at ±1.5 dB down from the peak of an unsaturated reflective event
Attenuation Dead Zone
Multimode 850/1300 nm
3 m
Measured at ±0.5 dB from the linear regression using an F/UPC-type reflectance
Attenuation Dead Zone
Singlemode 1310/1550 nm
3 m
Measured at ±0.5 dB from the linear regression using an F/UPC-type reflectance
Distance Display Range
Multimode 850/1300 nm
Up to 10 Km
Distance Display Range
Singlemode 1310/1550 nm
Up to 260 Km
Distance Measurement
Mode Automatic or dual cursor
Display Range 0.5 m to 260 km
Cursor Resolution 1 cm
Sampling Resolution 4 cm
Accuracy ± (0.5 m + sampling resolution + 0.001% x distance)
Excluding group index uncertainties
Attenuation Measurement
Mode Automatic, Manual, 2-point, 5-point, and LSA
Display Range 1.25 dB to 55 dB
Display Resolution 0.001 dB
Linearity ±0.03 dB/dB
Threshold 0.01 to 5.99 dB in 0.01 dB steps
Reflectance/ORL Measurements
Reflectance Accuracy ±2 dB
Display Resolution 0.01 dB
Threshold −11 to −99 dB in 1 dB steps
Optical Light Source
CW Source Output Power Level −3.5 dBm
Operating Modes CW, 270 Hz, 330 Hz, 1 kHz, 2 kHz, TWINTest

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • Premises and enterprise network installation and maintenance
  • Tier 2 certification of premises networks
  • Access and metro network installation and turn-up
  • Wireless fronthaul and backhaul networks
  • Mixed singlemode and multimode fiber testing
  • Data center fiber certification and troubleshooting

Included

  • SC/PC test port SM adapter
  • SC/PC test port MM adapter

Options & Accessories

Option Description
EUSCADS/-APC SC/PC (Blue), SC/APC (Green) Test Port SM Adapter, screw type
EULCADS/-APC LC/PC (Blue), LC/APC (Green) Test Port SM Adapter, screw type
EUFCADS FC Test Port SM Adapter, screw type
EULCADSMM LC/PC (Blue) Test Port MM Adapter, screw type
EUFCADSMM FC/PC Test Port MM Adapter, screw type
EUSTADSMM ST Test Port MM Adapter, screw type

Documents & Resources

4100 Series Quad OTDR Module
datasheet · PDF
OTDR Launch and Receive Cables
datasheet · PDF
OTDR application User Manual: 4100 Series OTDR modules, and SmartOTDR
manual · PDF
OneAdvisor 1000 - 4100-series OTDR, Expert OTDR
manual · PDF
OneAdvisor 1000 - 4100-series OTDR, Smart Test Assistant
manual · PDF
Quick Card: T-BERD/MTS-2000 - 4100-series OTDR, Expert OTDR
manual · PDF
Quick Card: T-BERD/MTS-5800 - 4100-series OTDR, Expert OTDR
manual · PDF
Quick Card: T-BERD/MTS-5800 - 4100-series OTDR, Smart Test Assistant
manual · PDF
T-BERD/MTS-2000 - 4100-series OTDR, Smart Test Assistant
manual · PDF
T-BERD/MTS-4000 - 4100-series OTDR, Smart Test Assistant
manual · PDF
T-BERD/MTS-4000 – 4100-Series OTDR, Expert OTDR
manual · PDF
OneAdvisor 800 Fiber Platform - Expert OTDR
manual · PDF
OneAdvisor 800 Fiber Platform - OTDR Smart Test Assistant
manual · PDF
OneAdvisor 800 Fiber Platform - OTDR Testing, Tips and Tricks
manual · PDF
OneAdvisor 800 Fiber Platform - Real Time Testing with Expert OTDR
manual · PDF
OneAdvisor 800 Fiber Platform - Real Time Testing with OTDR Smart Test Assistant
manual · PDF
OneAdvisor 800 Wireless Platform - Cable and Antenna Testing, Fiber (OTDR) Testing
manual · PDF
T-BERD/MTS-4000 V2 - Real Time Testing with OTDR Expert
manual · PDF
T-BERD/MTS-4000 V2 - Real Time Testing with OTDR Smart Test Assistant
manual · PDF
T-BERD/MTS-5800 - Real Time Testing with Expert OTDR
manual · PDF
T-BERD/MTS-5800 - Real Time Testing with OTDR Smart Test Assistant
manual · PDF
T-BERD/MTS-5800 - E4100 Module Optical Insertion Loss
manual · PDF
T-BERD/MTS-5800 - E4100 Module Optical Light Source Option
manual · PDF
T-BERD/MTS-5800 - E4100 Module Optical Power Meter
manual · PDF
FTTA Installation and Maintenance Testing Quick Start Guide, Vol. 2
manual · PDF
FTTA SmartLink Mapper (SLM) application user manual
manual · PDF
OTDR Solutions: T-BERD/MTS-2000 V2, -4000 V2, -5800, OneAdvisor and CellAdvisor 5G Platforms
brochure · PDF
Understanding Optical Time Domain Reflectometry (OTDR)
brochure
Test and Certification Solutions for Contractors
brochure · PDF
Test and Monitoring Solutions for Fiber to the Antenna (FTTA)
brochure · PDF
Understanding Fiber Optics
brochure
Important Factors for Choosing an Optical Time Domain Reflectometer (OTDR)
app note · PDF
Measure OTDR, return, and insertion loss on a single port to characterize optical links
app note · PDF
Improving OTDR measurement accuracy of a high K fiber pigtail
app note · PDF
Essentials of Fiber to the Antenna: Fiber Certification
app note · PDF
Essentials of Fiber to the Antenna: Fronthaul Installation Test
app note · PDF
Essentials of Fiber to the Antenna: Overview
app note · PDF
Data Center Use Case Test Guide
app note · PDF
Transform Fiber Construction Certification with the VIAVI StrataSync Test Process Automation (TPA) Suite
app note · PDF
Reference Guide to Fiber Optic Testing: Volume 1
app note
Reference Guide to Fiber Optic Testing: Volume 2
app note
Tier 2 OTDR and Connector Certification of Entreprise Networks
other · PDF
OTDR 2.0 Test Application Video Gallery
other
Choosing the best OTDR Acquisition Method
other
Choosing the best OTDR Testing Application on the T-BERD/MTS
other
How to Change the Fiber Optic Adapter (LC, FC, SC on MTS-4000)
other
VIAVI Care Support Plans
other · PDF
T-BERD/MTS-2000 Software
software
T-BERD/MTS-4000 Software
software
T-BERD/MTS-4000 V2 Software
software