VIAVI OneExpert CATV ONX-630 handheld cable meter, front view
ONX-630

OneExpert CATV ONX-630 DOCSIS 3.1 Signal Analysis and Sweep Meter

Handheld CATV signal analysis and sweep meter with DOCSIS 3.1 testing, forward sweep to 1.2 GHz and reverse sweep to 204 MHz.

Frequency range
0.5 to 1,218 MHz
Diplexer 42/85
Upstream 4-42 MHz and 4-85 MHz; Downstream 54-1,004 MHz and 108-1,218 MHz
Diplexer 42/204
Upstream 4-42 MHz and 4-204 MHz; Downstream 54-1,004 MHz and 258-1,218 MHz
Diplexer 65/204
Upstream 4-65 MHz and 4-204 MHz; Downstream 83-1,218 MHz and 258 MHz-1,218 MHz
Datasheet

Overview

The VIAVI OneExpert CATV ONX-630 is a handheld meter for maintaining HFC cable networks. It combines DOCSIS 3.1 performance analysis, spectrum analysis, and forward and reverse sweep measurements in one instrument. It is the plant-maintenance model of the OneExpert CATV platform, which also includes the ONX-620.

A multi-touch interface and OneCheck automated tests show results on a dashboard with clear pass/fail indications. AutoChannel identifies the channel lineup automatically, so no channel plan has to be built. A downstream scan that includes MER and BER on all channels takes about 60 seconds. Ingress and downstream testing run at the same time through the DuoPort design with PosiScan.

Sweep

The ONX-630 works with the SCU-1800 Sweep Control Unit installed at the headend or hub. Together they provide downstream sweep to 1.2 GHz and upstream sweep to 204 MHz. The meter is also backward compatible with existing SDA-5500 and SDA-5510 sweep transmitters, and it can sweep side by side with DSAM-6300 meters. Sweepless Sweep references existing carriers to give a normalized response in distributed access architecture networks. Reverse alignment mode shows the levels of signals that the meter injects, as received at the headend.

Expert modes and connectivity

Channel Expert, DOCSIS Expert and Ingress Expert with Hyper Spectrum gapless FFT help technicians find intermittent problems and their root causes. Session Expert compares results taken at the tap, ground block and CPE, and suggests corrective actions. The meter supports DOCSIS 3.0 32x8 bonding, WiFi testing at 2.4 GHz and 5 GHz, and dual Gigabit Ethernet. Optional add-ons include a fiber scope and an optical power meter. Results, assets and software are managed through StrataSync, which offers sweep reporting shared with DSAM meters.

Key Features

  • DOCSIS 3.1 physical and service performance testing, including OFDM signal analysis, cable modem ranging and registration
  • DOCSIS 3.0 32x8 bonding for Gigabit speeds
  • Forward sweep to 1.2 GHz and reverse sweep to 204 MHz
  • Sweep backward compatible with SDA-5500/SDA-5510 and side-by-side with DSAM-6300 meters
  • Works with the SCU-1800 Sweep Control Unit with up to 16 return sweep ports
  • Sweepless Sweep mode referencing existing carriers
  • Reverse alignment mode for a quick view of tilt carriers
  • DuoPort design with PosiScan for simultaneous Ingress Scan and Downstream tests
  • AutoChannel automatic channel plan identification
  • OneCheck dashboard with MER/BER on the full lineup in about 60 seconds
  • Session Expert background analysis with problems detected and suggested actions
  • Ingress Expert with Hyper Spectrum gapless FFT technology
  • Channel Expert, DOCSIS Expert and Quick Check Expert modes
  • Dual diplexers supporting 42/85, 65/204, 42/204 or 85/204 MHz networks
  • Field-exchangeable DOCSIS/RF module
  • WiFi 2.4 GHz and 5 GHz testing and wireless personal area network
  • Dual GigE Ethernet with optional TrueSpeed testing
  • Optional P5000i fiber scope and MP-60/MP-80 optical power meter support
  • Cloud enabled via StrataSync for asset and test data management
  • Built-in usage guide

Specifications

Frequency Range
Frequency range 0.5 to 1,218 MHz
Diplexer 42/85
ONX-630D31-4285-1012-NTX, ONX-630D31-4285-1012-SWX
Upstream 4-42 MHz and 4-85 MHz; Downstream 54-1,004 MHz and 108-1,218 MHz
Automatically switching diplexer
Diplexer 42/204
ONX-630D31-4220-1012-NTX, ONX-630D31-4220-1012-SWX
Upstream 4-42 MHz and 4-204 MHz; Downstream 54-1,004 MHz and 258-1,218 MHz
Automatically switching diplexer
Diplexer 65/204
ONX-630D31-6520-1212-NTX, ONX-630D31-6520-1212-SWX
Upstream 4-65 MHz and 4-204 MHz; Downstream 83-1,218 MHz and 258 MHz-1,218 MHz
Automatically switching diplexer; the Sweep and Maintenance System data sheet lists 65 MHz downstream as 85-1,218 MHz
Diplexer 85/204
ONX-630D31-8520-1212-NTX, ONX-630D31-8520-1212-SWX
Upstream 4-85 MHz and 4-204 MHz; Downstream 108-1,218 MHz and 258-1,218 MHz
Automatically switching diplexer
MoCA filter All models have MoCA triplexer to filter out MoCA signals below the highest downstream frequency.
Accuracy ±10 ppm
typical @25°C
Downstream Analysis — Port 1
AutoChannel plan builder Auto detection of channel parameters (analog/digital, symbols, QAM)
Max input power 60 dBmV total integrated power
Dynamic range >80 dB
at 44 kHz RBW
Operation on powered tap Operate with up to 90 V AC/DC on input port
Return loss >9 dB
Upstream Analysis — Port 2
Ingress spectrum scan 0.5 – 204 MHz
calibrated range 4-204MHz
Sensitivity −45 dBmV
RBW 300 kHz
Min detectable level upstream −55 dBmV
Dynamic range
ONX-630
60dB
ONX-630 value from the OneExpert CATV data sheet; the Sweep and Maintenance System data sheet lists 50 dB
Max total integrated power 55 dBmV, 4 – 10 MHz; 60 dBmV, 10 to 204 MHz
Accuracy ±2 dB
typical at 25°C
Sampling rate Hyper Spectrum FFT gapless technology - no missed samples, spans 0.5 -110 MHz, 110 to 160 MHz, and 160 to 204 MHz
Return loss >9.5 dB
Power detection/notification Notify of AC/DC power presence on port 2 above 2 Volts
Upstream Signal Generator
Number of signals generated simultaneously From 1 to 8
Signal types Signals either all CW or all modulated
Modulation supported QPSK, 16 QAM, and 64 QAM
Symbol rates supported 5.12, 2.56, 1.28, 0.64, 0.32, and 0.16 Msym/s
Analog Channel Measurement
Standards NTSC, PAL, SECAM
Video and audio levels (dual)
Min detectable signal −50 dBmV (single channel)
Level accuracy ±1.5 dB from −20 dBmV to +50 dBmV typical at 25°C; ±2.0 dB, −10°C to +50°C
The Sweep and Maintenance System data sheet states ±2.0 dB, −20°C to +50°C
Carrier to noise range 30 to 51 dB
NTSC, 4 MHz measurement bandwidth
Carrier to noise accuracy ±2.0 dB
within specified measurement range ≤ 600 MHz
Downstream Digital Channel Analysis
Calibrated power levels -20 dBmV to +50 dBmV
Level accuracy ±1.5 dB from -20 dBmV to +50 dBmV typical at 25°C; ±2.0 dB, -10°C to +50°C
Modulations 64, 128, and 256 QAM, OFDM
Symbol rates Annex A: 5.057 to 6.952 MSPS; Annex B: 5.057 for 64 QAM and 5.361 MSPS for 256 QAM; Annex C: 5.274 MSPS for 64 QAM and 5.361 MSPS for 256 QAM
Regional demods DVB-C
Hum frequency range 25 Hz to 1000 Hz
Minimum MER 33 dB
OFDM Signal Performance Metrics
OFDM channels 24 - 192 MHz wide - up to 3 active OFDM channels
MER — max, min, average, standard deviation, percentile 12 to 50 dB
The Sweep and Maintenance System data sheet lists 16 to 44 dB
Profile analysis Profiles A, B, C, D, NCP, and PLC (more profiles as implemented)
Lock status, codeword errors (corrected and uncorrected)
DOCSIS Testing
DOCSIS 3.1 bonding up to 32 SC-QAM + 2 OFDM downstream channels, 8 SC-QAM + 2 OFDMA upstream channels
Compliant with CableLabs specifications for DOCSIS 3.1 and DOCSIS 3.0 (32x8 bonding)
Downstream frequency range 54/85/108/258 to 1,000/1,218 MHz
dependent on currently active diplexer frequency
Upstream frequency range 5 to 204 MHz
dependent on currently active diplexer frequency
Transmit level range (max) +61 to +48 dBmV
depending on modulation format and number of bonded carriers, per DOCSIS specification
Service tests Registration, Throughput, Ping/Traceroute, Packet Quality; cable modem pass-through
MER and BER
MER specified range 21 to 40 dB, 64 QAM; 28 to 40 dB, 256 QAM; 16 to 44 dB OFDM
with input level -5 to +20 dBmV; MER range declines as input levels decrease
Max displayable range 50 dB
Resolution 0.1 dB
Accuracy ±2 dB
typical at 25°C
Minimum lock level −15 dBmV
BER — ChannelCheck and DOCSISCheck mode Down to 1E-9 (pre and post FEC)
BER — OneCheck mode Down to 1E-8 (pre and post FEC) default; 1E-9 user selectable
Interleaver depth 128, 8 max
Sweep
Forward sweep telemetry frequency Diplexer dependent 50-1,218 MHz
Forward sweep input port Port 1
Forward sweep compatibility SCU-1800 or SDA-5500 in SDA Compatibility Mode
Reverse sweep output transmit port Port 1 or Port 2 (user selectable)
Port 1 reverse sweep frequency range Diplexer dependent 5-42/5-65/5-85/5-204 MHz
Port 2 reverse sweep frequency range 5-204MHz
Display/Interface/Usability
High-brightness color LCD 5 inch diagonal (800 x 480)
Touch screen Capacitive
Hard key navigation capable
Boot time Approximately 20 sec
Input/Outputs
RF (2) F connectors replaceable
Port 1 Downstream 54/85/108/258 MHz depending on diplexer
Port 2 Upstream 0.5 – 204 MHz and TDR
The OneExpert CATV data sheet states Upstream 4 – 204 MHz and TDR
USB host 2
Ethernet (2) RJ45 10/100/1000T
Remote access/connectivity VNC accessible via IP address; HTTPS file access via IP address; Mobile application via wireless personal area network
WiFi test interface 802.11 a/b/g/n (2.4/5 GHz)
Battery
Battery Field replaceable 96 W/hr 10.4 V, 10-cell LiIon
Typical battery life 6 – 8 hr continuous, 15 – 20 hr typical usage
Battery charge time 4 Hrs (90%); 6 - 8 Hrs 100% (AC charger)
Environmental
For indoor/outdoor use IP 54 light rain (0.5 in/hr; 1.27 cm/hr)
Drop 1 m (3.3 ft) onto concrete
Operating temperature −10 to 50°C (14 to 122°F)
Storage temperature −20 to 60°C (-4 to 140°F)
Humidity 10 – 90% RH non-condensing
RF immunity 8.5 V/m
for CATV measurements
Maximum altitude 4000 m (13,123 ft)
Pollution 2°
Physical
Weight 5.95 lb (2.7 kg)
Protective case and shoulder strap 0.95 lb

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • HFC network maintenance with forward and reverse sweep
  • Amplifier alignment and tilt verification
  • Troubleshooting service issues between the TAP, ground block and CPE
  • Intermittent QAM carrier and home network issues
  • DOCSIS 3.1 and Gigabit service testing
  • Ingress and return-path noise troubleshooting
  • WiFi signal strength verification at 2.4 GHz and 5 GHz
  • Business service turn-up and troubleshooting
  • PON and RFoG installation and troubleshooting
  • Remote PHY and distributed access architecture turn-up

Included

  • Protective case with hand strap and detachable shoulder strap
  • AC power supply with choice of country-specific adaptor plug
  • Quick start guide
  • StrataSync Core support

Options & Accessories

Option Description
ONX-630D31-4285-1012-NTX ONX-630 NTX package, 42/85 MHz dual diplexer — 42/85 MHz; 1.0G/1.2G
ONX-630D31-6520-1212-NTX ONX-630 NTX package, 65/204 MHz dual diplexer — 65/204 MHz; 1.2G/1.2G
ONX-630D31-4220-1012-NTX ONX-630 NTX package, 42/204 MHz dual diplexer
ONX-630D31-8520-1212-NTX ONX-630 NTX package, 85/204 MHz dual diplexer
ONX-630D31-4285-1012-SWX ONX-630 SWX package, 42/85 MHz dual diplexer — 42/85 MHz; 1.0G/1.2G
ONX-630D31-6520-1212-SWX ONX-630 SWX package, 65/204 MHz dual diplexer — 65/204 MHz; 1.2G/1.2G
ONX-630D31-4220-1012-SWX ONX-630 SWX package, 42/204 MHz dual diplexer
ONX-630D31-8520-1212-SWX ONX-630 SWX package, 85/204 MHz dual diplexer
ONX-CATV-SW-FWD-SWEEP Forward Sweep — Optional on NTX; standard on SWX
ONX-CATV-SW-REV-SWEEP Reverse Sweep — Optional on NTX; standard on SWX
ONX-CATV-SW-REV-ALIGN Reverse Alignment — Optional on NTX; standard on SWX
ONX-CATV-SW-REVSWPLSSWP Reverse Sweepless Sweep
ONX-CATV-RAPIDREVSW Rapid Reverse Sweep Option — Included on SWX models
ONX-TRUESPEED TrueSpeed
ONX-CATV-IPVIDEO IP Video — Listed as ONX-CATV-SW-IPVIDEO in the Sweep and Maintenance System data sheet
ONX-VOIP VoIP
ONX-MOS MOS for VoIP
ONX-CATV-SW-HOMETDR HomeTDR
ONX-CATV-SW-HL-LKG Home Leakage Software Option
ONX-CATV-SW-OUDP-LKG OneExpert CATV and HFC OUDP Leakage Software Option
ONX-CATV-SW-QAM-VIDEO OneExpert CATV QAM Video MPEG Verification Option
ONX-CATV-SW-RP-SNR-OCE Return Path SNR Option
TRI-LKG-HL-METER-KIT Seeker Home Leakage Test Kit
UPG-ONX-D31-S-4220-1012 ONX-630 42/204 MHz Sweep Ready Upgrade Module
UPG-ONX-D31-S-8520-1212 ONX-620/630 85/204 MHz Upgrade Module — RF module only; requires trade-in
UPG-ONX-CATV-SW-QAMVIDEO Field Upgrade (via StrataSync) QAM Video Option
UPG-ONX-CATV-SW-RP-SNR Field Upgrade (via StrataSync) Return Path SNR Option
UPG-ONX-CATV-SW-HOMETDR HomeTDR Software Upgrade via StrataSync
UPG-ONX-CATV-RAPIDREVSW Field Upgrade (via StrataSync) Rapid Reverse Sweep Option
UPG-ONX-CATV-SW-HL-LKG Field Upgrade via SS HL Leakage Software Option — Requires D3.1 HW
UPG-ONX-CATV-SW-OUDP-LKG Field Upgrade via SS OUDP Leakage Software Option — Requires D3.1 HW
BRONZE-5 Five-year warranty
SILVER-3 One calibration
SILVER-5 Five-year warranty and two calibrations
AC-CHARGER Replacement Charger (no power cord)
AC-CAR-CHARGER Car Charger
ONX-CATV-STD-ACCY-KIT Replacement Fitted Case
1019-00-1366 Strand Hook
ONX-CATV-BATT-96WHR Replacement 96 W/Hr Battery
ONX-SCREEN-PROTECTION Replacement Screen Protector (5 pack)
ONX-CATV-DLX-ACCY-KIT Deluxe accessory kit — Large Accessory Bag, Fitted Case, 12V Adapter, Strand Hook, Ethernet Patch Cord (1 m), Extra Hand Strap
MP-80A MP-80 USB Optical Power Meter
MP-60A MP-60 USB Optical Power Meter
FI-60 FI-60 Live Fiber Identifier
FBP-P5000I P5000i USB Fiber Scope
WFED-300AC WiFi Advisor standard package
WFED300AC-1PC WiFi Advisor test device, carrying case, USB cable, AC power supply, and power cord

Documents & Resources