VIAVI OneExpert CATV ONX-620 handheld signal analysis meter, front view
ONX-620

OneExpert CATV ONX-620 DOCSIS 3.1 Handheld Signal Analysis Meter

Handheld CATV signal analysis meter for DOCSIS 3.1/3.0 testing, ingress and downstream analysis, WiFi and Ethernet service verification.

Diplexer 42/85
Upstream 4-42 MHz and 4-85 MHz; Downstream 54-1,004 MHz and 108-1,218 MHz
Diplexer 42/204
Upstream 4-42 MHz and 4-204 MHz; Downstream 54-1,004 MHz and 258-1,218 MHz
Diplexer 65/204
Upstream 4-65 MHz and 4-204 MHz; Downstream 83-1,218 MHz and 258 MHz-1,218 MHz
Diplexer 85/204
Upstream 4-85 MHz and 4-204 MHz; Downstream 108-1,218 MHz and 258-1,218 MHz
Datasheet

Overview

The VIAVI OneExpert CATV ONX-620 is a handheld signal analysis meter for cable television and home network installation and troubleshooting. It is a member of the OneExpert CATV platform and is offered in Basic, IPX and TSX packages with dual-diplexer RF modules.

A multi-touch interface and OneCheck automated tests present results on a dashboard with pass/fail indications. AutoChannel identifies the channel plan automatically, and a OneCheck run covers the full lineup, including MER and BER on all channels, in about a minute. Ingress and downstream testing are performed simultaneously through the DuoPort design with PosiScan.

Session Expert performs background analysis of the results gathered at the tap, ground block and CPE, identifies problems and suggests corrective actions. Results and assets are managed through the cloud-based StrataSync service.

Platform and connectivity

The meter supports DOCSIS 3.1 physical and service performance testing (option), DOCSIS 3.0 32x8 bonding, WiFi in the 2.4 GHz and 5 GHz bands, dual Gigabit Ethernet and a wireless personal area network for mobile app integration. The DOCSIS/RF module is field-exchangeable, and the dual-diplexer design supports transition to extended return bands. Optional capabilities include TrueSpeed, IP video, VoIP, HomeTDR, home leakage testing, and USB fiber scope and optical power meter support.

Key Features

  • DuoPort design with PosiScan for simultaneous Ingress Scan and Downstream tests
  • AutoChannel automatic channel plan identification
  • OneCheck dashboard with MER/BER on all channels in about 60 seconds
  • Session Expert background analysis with suggested actions
  • Cloud enabled via StrataSync for test results and compliance tracking
  • Built-in usage guide
  • DOCSIS 3.0 32x8 bonding; DOCSIS 3.1 option
  • WiFi 2.4 GHz and 5 GHz and wireless personal area network
  • Dual GigE Ethernet with optional TrueSpeed
  • Optional fiber scope and power meter support
  • Field-exchangeable DOCSIS/RF module
  • Dual-diplexer design supporting 42/85, 65/204, 42/204 and 85/204 MHz splits
  • 5 inch capacitive touch screen, 800 x 480
  • Field replaceable 96 W/hr Li-Ion battery

Specifications

Frequency Range
Diplexer 42/85 Upstream 4-42 MHz and 4-85 MHz; Downstream 54-1,004 MHz and 108-1,218 MHz
Automatically switching diplexer
Diplexer 42/204 Upstream 4-42 MHz and 4-204 MHz; Downstream 54-1,004 MHz and 258-1,218 MHz
Diplexer 65/204 Upstream 4-65 MHz and 4-204 MHz; Downstream 83-1,218 MHz and 258 MHz-1,218 MHz
Diplexer 85/204 Upstream 4-85 MHz and 4-204 MHz; Downstream 108-1,218 MHz and 258-1,218 MHz
Accuracy ±10 ppm typical @25°C
Downstream Analysis — Port 1
AutoChannel Plan Builder Auto detection of channel parameters (analog/digital, symbols, QAM)
Max input power 60 dBmV total integrated power
Dynamic range >80 dB at 44 kHz RBW
Operation on powered tap Operate with up to 90 V AC/DC on input port
Return loss >9 dB
Upstream Analysis — Port 2
Ingress spectrum scan 0.5 – 204 MHz
Sensitivity −45 dBmV
RBW 300 kHz
Min detectable level upstream −55 dBmV
Dynamic range
ONX-620
50dB
ONX-630: 60 dB
Max total integrated power 55 dBmV, 4 – 10 MHz; 60 dBmV, 10 to 204 MHz
Accuracy ±2 dB
typical at 25°C
Sampling rate Hyper Spectrum FFT gapless technology - no missed samples, spans 0.5 -110 MHz, 110 to 160 MHz, and 160 to 204 MHz
Return loss >9.5 dB
Power detection/notification Notify of AC/DC power presence on port 2 above 2 Volts
Upstream Signal Generator
Number of signals generated simultaneously From 1 to 8
Signal types Signals either all CW or all modulated
Modulation supported QPSK, 16 QAM, and 64 QAM
Symbol rates supported 5.12, 2.56, 1.28, 0.64, 0.32, and 0.16 Msym/s
Analog Channel Measurement
Standards NTSC, PAL, SECAM
Min detectable signal −50 dBmV
single channel
Level accuracy ±1.5 dB from −20 dBmV to +50 dBmV typical at 25°C; ±2.0 dB, −10°C to +50°C
Carrier to noise range 30 to 51 dB
NTSC, 4 MHz measurement bandwidth
Carrier to noise accuracy ±2.0 dB within specified measurement range ≤ 600 MHz
Downstream Digital Channel Analysis
Calibrated power levels -20 dBmV to +50 dBmV
Level accuracy ±1.5 dB from -20 dBmV to +50 dBmV typical at 25°C; ±2.0 dB, -10°C to +50°C
Modulation(s) 64, 128, and 256 QAM, OFDM
Regional demods DVB-C
Hum frequency range 25 Hz to 1000 Hz
MER specified range 21 to 40 dB, 64 QAM; 28 to 40 dB, 256 QAM; 16 to 44 dB OFDM
With input level -5 to +20 dBmV; MER range declines as input levels decrease
MER accuracy ±2 dB
typical at 25°C
Minimum lock level −15 dBmV
BER — ChannelCheck and DOCSISCheck mode Down to 1E-9 (pre and post FEC)
BER — OneCheck mode Down to 1E-8 (pre and post FEC) default; 1E-9 user selectable
OFDM and DOCSIS
OFDM channels 24 - 192 MHz wide - up to 3 active OFDM channels
DOCSIS 3.1 testing is optional on ONX-620 packages
OFDM profile analysis Profiles A, B, C, D, NCP, and PLC
more profiles as implemented
DOCSIS bonding Supports DOCSIS 3.1 bonding up to 32 SC-QAM + 2 OFDM downstream channels, 8 SC-QAM + 2 OFDMA upstream channels
Downstream frequency range 54/85/108/258 to 1,000/1,218 MHz
dependent on currently active diplexer frequency
Upstream frequency range 5 to 204 MHz
dependent on currently active diplexer frequency
Transmit level range (max) +61 to +48 dBmV
depending on modulation format and number of bonded carriers, per DOCSIS specification
Display/Interface
Display High-Brightness Color LCD (800 x 480), 5 inch diagonal
Touch screen Capacitive
Hard key navigation capable
Boot time Approximately 20 sec
RF (2) F connectors replaceable
USB Host (2)
Ethernet (2) RJ45 10/100/1000T
WiFi test interface 802.11 a/b/g/n (2.4/5 GHz)
WiFi access point
IPX, TSX
Configure OneExpert CATV as WiFi access point (Ethernet to WiFi bridge)
IPX, TSX models only
Environmental
For indoor/outdoor use IP 54 light rain (0.5 in/hr; 1.27 cm/hr)
Drop 1 m (3.3 ft) onto concrete
Operating temperature −10 to 50°C (14 to 122°F)
Storage temperature −20 to 60°C (-4 to 140°F)
Humidity 10 – 90% RH non-condensing
RF immunity 8.5 V/m
for CATV measurements
Maximum altitude 4000 m (13,123 ft)
Power and Physical
Battery Field replaceable 96 W/hr 10.4 V, 10-cell LiIon
Typical battery life 6 – 8 hr continuous, 15 – 20 hr typical usage
Battery charge time 4 Hrs (90%); 6 - 8 Hrs 100% (AC charger)
Weight 5.95 lb (2.7 kg)
Protective case and shoulder strap 0.95 lb
Ordering — ONX-620 Packages
Basic 42/85
Basic
ONX-620D31-4285-1010-BAS
Basic 65/204
Basic
ONX-620D31-6520-1212-BAS
IPX 42/85
IPX
ONX-620D31-4285-1010-IPX
IPX 65/204
IPX
ONX-620D31-6520-1212-IPX
IPX 42/204
IPX
ONX-620D31-4220-1012-IPX
IPX 85/204
IPX
ONX-620D31-8520-1212-IPX
TSX 42/85
TSX
ONX-620D31-4285-1010-TSX
TSX 65/204
TSX
ONX-620D31-6520-1212-TSX
TSX 42/204
TSX
ONX-620D31-4220-1012-TSX
TSX 85/204
TSX
ONX-620D31-8520-1212-TSX

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • Troubleshooting QAM carriers and home networks
  • Troubleshooting service issues between tap, ground block and CPE
  • Verifying WiFi networks
  • Testing Gigabit DOCSIS services
  • Business service turn-up and troubleshooting
  • PON and RFoG installation including inspection, power levels and RF performance
  • Home leakage testing
  • Remote PHY turn-up and maintenance

Included

  • Protective case with hand strap and detachable shoulder strap
  • AC power supply with choice of country-specific adaptor plug
  • Quick start guide
  • StrataSync Core support

Options & Accessories

Option Description
ONX-TRUESPEED TrueSpeed
ONX-CATV-IPVIDEO IP Video
ONX-CATV-SW-D31 DOCSIS 3.1
ONX-VOIP VoIP
ONX-CATV-SW-INGRESS-EXP Ingress Expert
ONX-CATV-SW-RSG Return Signal Generator
ONX-CATV-SW-RSG-LOOP Return Signal Generator w/ Loop-back
ONX-CATV-SW-HOMETDR HomeTDR
TRI-LKG-HL-METER-KIT Seeker Home Leakage Test Kit
ONX-CATV-SW-HL-LKG Home Leakage Software Option
ONX-CATV-SW-OUDP-LKG OneExpert CATV and HFC OUDP Leakage Software Option
ONX-CATV-SW-RP-SNR-OCE Return Path SNR Option
UPG-ONX-D31-4220-1012 ONX-620 42/204 MHz Upgrade Module
UPG-ONX-D31-S-8520-1212 ONX-620/630 85/204 MHz Upgrade Module — RF module only; requires trade-in
UPG-ONX-CATV-SW-RP-SNR Field Upgrade (via StrataSync) Return Path SNR Option
UPG-ONX-CATV-SW-HOMETDR HomeTDR Software Upgrade via StrataSync
UPG-ONX-CATV-SW-HL-LKG Field Upgrade via SS HL Leakage Software Option — Requires D3.1 HW
UPG-ONX-CATV-SW-OUDP-LKG Field Upgrade via SS OUDP Leakage Software Option — Requires D3.1 HW
BRONZE-5 Five-year warranty
SILVER-3 One calibration
SILVER-5 Five-year warranty and two calibrations
AC-CHARGER Replacement Charger (no power cord)
AC-CAR-CHARGER Car Charger
ONX-CATV-STD-ACCY-KIT Replacement Fitted Case
1019-00-1366 Strand Hook
ONX-CATV-BATT-96WHR Replacement 96 W/Hr Battery
ONX-SCREEN-PROTECTION Replacement Screen Protector (5 pack)
ONX-CATV-DLX-ACCY-KIT Deluxe accessory kit — Large Accessory Bag, Fitted Case, 12V Adapter, Strand Hook, Ethernet Patch Cord (1 m), Extra Hand Strap
MP-80A MP-80 USB Optical Power Meter
MP-60A MP-60 USB Optical Power Meter
FI-60 FI-60 Live Fiber Identifier
FBP-P5000I P5000i USB Fiber Scope

Documents & Resources