CellAdvisor JD723C Cable and Antenna Analyzer, 100 MHz to 2.7 GHz
Handheld 100 MHz to 2.7 GHz cable and antenna analyzer for 1-port line sweep, RF and optical power measurement and fiber inspection.
- Frequency range
- 100 MHz – 2.7 GHz
- Frequency resolution
- 10 kHz
- Frequency accuracy
- ±5 ppm at 25°C
- Aging per year
- ± 1.5 ppm
Overview
The VIAVI CellAdvisor JD723C is a handheld cable and antenna analyzer in the JD720C series that covers 100 MHz to 2.7 GHz. It is designed for cell-site installation and maintenance. It combines line sweep measurements, RF and optical power measurement, and fiber inspection in one lightweight instrument.
Most faults in mobile networks occur in the cell-site infrastructure: the antenna system, the RF and fiber feed lines, and the connectors. Contaminated fiber connectors are the most common fiber-related problem. Sites with fiber-based feed lines need both RF and fiber verification. The JD723C covers both, so a separate fiber instrument is not needed.
Measurements
The JD723C performs 1-port tests: reflection (VSWR or return loss), distance to fault (DTF), 1-port cable loss, 1-port phase and Smith chart display. With external VIAVI power sensors and USB optical power meters it measures RF and optical power. With the P5000i fiber microscope it inspects fiber connectors and gives pass/fail results. Its built-in database has more than 80 wireless frequency bands and more than 95 cable types, and users can add more of each.
Operation and connectivity
The instrument has a 7-inch transflective color touch screen with an outdoor mode for direct sunlight and a backlit keypad for use in the dark. Traces can be compared with Trace Overlay and analysed using zoom zones, dual display, and limit lines with automatic pass/fail. Reports in PDF or HTML can be generated on the instrument. The JDViewer and JDRemote PC applications handle post-analysis and remote control. Bluetooth, GPS, WiFi and TestWizard are available as options.
Key Features
- RF and fiber testing in a single instrument
- Trace Overlay of up to four traces to detect signal degradation over time
- Dual Display mode shows two measurements simultaneously
- Pass/fail indications with standard, multi-segment and window limit lines
- EZ-Cal electronic calibration support
- Fiber inspection with pass/fail indications using the P5000i fiber microscope
- RF and optical power measurement using external power sensors and meters
- Three zoom zones for detailed analysis on multi-frequency bands
- Up to 40 dBm (10 W) RF port protection
- PDF/HTML report generation
- Automatically saves events that exceed pre-defined limits
- JDViewer post-analysis and JDRemote remote control application software
- Web-based remote control via Bluetooth and Wi-Fi
- Self-guided systematic test procedures with TestWizard (option)
- Database of over 80 wireless frequency bands and over 95 cable types
- 7-inch transflective touch screen with outdoor and night display modes
- Multilanguage user interface
Specifications
| Frequency range | 100 MHz – 2.7 GHz |
|---|---|
| Frequency resolution | 10 kHz |
| Frequency accuracy |
±5 ppm at 25°C
Applies to JD723C serial number IDE33869 and later
|
| Aging per year |
± 1.5 ppm
Applies to JD723C serial number IDE33869 and later
|
| Data points | 126, 251, 501, 1001, 2001 |
| Reflection | < 0.7 ms/point |
|---|---|
| DTF | < 0.8 ms/point |
| Corrected directivity (OSL calibration) |
>42 dB
Typical, after OSL calibration
|
|---|---|
| Corrected directivity (EZ-Cal calibration) |
≤ 4 GHz: >38 dB
Typical, after EZ-Cal calibration; using recommended calibration kits, serial number KR31659001 and later
|
| Reflection uncertainty |
±(0.3 + |20log (1 + 10^(-EP/20))|)
Typical; EP = directivity – measured return loss
|
| Output power, high |
0 dBm
Nominal
|
|---|---|
| Output power, low |
–30 dBm
Nominal
|
| Maximum input level, average continuous power |
+25 dBm
Nominal
|
| Maximum input level, DC voltage | ±50 V DC |
| RF port protection | Up to 40 dBm (10 W) |
| VSWR range | 1 to 65 |
|---|---|
| VSWR resolution | 0.01 |
| Return loss range | 0 to 60 dB |
| Return loss resolution | 0.01 dB |
| Vertical VSWR range | 1 to 65 |
|---|---|
| Vertical VSWR resolution | 0.01 |
| Vertical return loss range | 0 to 60 dB |
| Vertical resolution | 0.01 dB |
| Horizontal range | 0 to (# of data points – 1) x horizontal resolution; Maximum = 1500 m (4921 ft) |
| Horizontal resolution |
(1.5 x 10^8) x (VP)/delta
VP = propagation velocity; delta = stop frequency – start frequency (Hz)
|
| 1-port cable loss range | 0 to –30 dB |
|---|---|
| 1-port cable loss resolution | 0.01 dB |
| 1-port phase |
–180 to +180°
Listed as 'Resolution' in the datasheet
|
| Smith chart resolution | 0.01° |
| RF power meter (standard) display range | –80 to +120 dBm |
|---|---|
| RF power meter offset range | 0 to 60 dB |
| RF power meter resolution | 0.01 dB or 0.1 x W (x = m, u, p) |
| Optical power meter (standard) display range | –100 to +100 dBm |
| Optical power meter offset range | 0 to 60 dB |
| Optical power meter resolution | 0.01 dB or 0.1 mW |
| Bluetooth |
Personal area network (PAN), File transfer profile (FTP) interface
Option 003
|
|---|---|
| WiFi interface type |
USB LAN Card
Option 006
|
| WiFi interface standard |
IEEE 802.11 b/g/n
Option 006
|
| Web-based remote control | Internet Explorer, Chrome, Safari |
| USB GPS location |
Latitude and longitude on display
Option 004
|
| USB GPS interface |
USB 2.0
Option 004
|
| Reflection/RF Out connector | Type-N, female |
|---|---|
| Reflection/RF Out impedance | 50 Ω (nominal) |
| Reflection/RF Out damage level | > +40 dBm, > ±50 V DC (nominal) |
| RF In |
N/A
RF In port not available on JD723C
|
| USB host |
Type A, 2 ports
Connects flash drive, power sensor, P5000i, Bluetooth adapter, WiFi LAN card, or GPS receiver
|
| USB client |
Mini B, 1 port
Connects to PC/laptop for data transfer
|
| LAN | RJ45, 10/100Base-T |
| Serial |
9-pin D-SUB male
For JD72450551/JD72450552
|
| Type | Resistive touch screen |
|---|---|
| Size | 7-inch, LED backlight, transflective LCD |
| Resolution | 800 x 480 |
| Speaker | Built-in speaker |
| External DC input | 12 to 15 VDC |
|---|---|
| Power consumption |
12 W; 34.5 W maximum (when charging battery)
JD723C/JD724C column
|
| External AC power adapter input | 100 to 250 V (50 to 60 Hz, 1.2 A) |
| External AC power adapter output | 15 V DC, 4 A |
| Battery type | 10.8 V, 7800 mA/hr (LiON) |
| Battery operation time |
>7.5 hr (typical)
JD723C/JD724C column
|
| Charge time | 3 hr (80%), 5 hr (100%) |
| Charging temperature | 0 to 45°C (32 to 104°F) ≤85% RH |
| Discharging temperature | –20 to 55°C (4 to 131°F) ≤85% RH |
| Battery storage temperature |
0 to 25°C (32 to 77°F) ≤95% RH (noncondensing)
20 to 85% RH; extended exposure above 45°C could significantly degrade battery performance and life
|
| Internal |
Maximum 900 MB
Up to 26,000 traces (JD723C/JD724C)
|
|---|---|
| External |
Limited by size of USB flash drive
Supports USB 2.0-compatible memory devices
|
| Operating temperature, AC power | 0 to 40°C (32 to 104°F) with no derating |
|---|---|
| Operating temperature, battery | 0 to 40°C (32 to 104°F) at charging; –10 to 55°C (14 to 131°F) at discharging |
| Maximum humidity | 95% RH (noncondensing) |
| Storage temperature |
–40 to 70°C (–40 to +158°F)
With the battery pack removed
|
| Shock and vibration | MIL-PRF-28800F Class 2 |
| ESD | IEC/EN 61000-4-2 |
| RoHS | EN 50581:2012 |
| Size (W x H x D) |
260 x 190 x 60 mm (10.2 x 7.5 x 2.4 in)
With battery
|
|---|---|
| Weight |
2.35 kg (5.18 lb)
With battery; JD723C/JD724C column
|
| Calibration cycle | 2 years |
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- Verification of cell-site cable and antenna systems
- Testing distributed radios with RF and fiber feed lines
- DAS deployment validation
- NFC antenna testing (RFID and security equipment)
Included
- AC/DC power adapter
- Cross LAN cable
- USB A to Mini B cable
- USB memory
- Automotive cigarette lighter/12 V DC adapter
- Rechargeable LiON battery
- Stylus pen
- Soft carrying case
- JD720C series user's manual and application software
Options & Accessories
| Option | Description |
|---|---|
| JD720C003 | Bluetooth connectivity — Includes a USB Bluetooth dongle and dipole antenna (JD70050006); wireless remote control and monitoring from a Windows-based computer running JDRemote |
| JD720C004 | USB GPS connectivity — Includes a USB GPS receiver; position stamp and GPS-tagged PDF reports |
| JD720C006 | WiFi connectivity — Includes a WiFi dongle (JD70050008); web-browser remote control and monitoring |
| JD720C007 | TestWizard — Self-guided systematic test procedures using files created in Test Wizard Creator |
| JD720CU | Upgrade option prefix — Upgrade options for the JD720C use the designation JD720CU before the respective last three-digit option number |
| JD78050509 | Y-calibration kit Type-N(m), DC to 6 GHz, 50 Ω |
| JD78050510 | Y-calibration kit DIN(m), DC to 6 GHz, 50 Ω |
| JD70050509 | Electronic calibration kit (EZ-Cal) |
| JD731B | Directional power sensor (peak and average), 300 MHz to 3.8 GHz, average 0.15 to 150 W, peak 4 to 400 W |
| JD733A | Directional power sensor (peak and average), 150 MHz to 3.5 GHz, average/peak 0.1 to 50 W |
| JD732B | Terminating power sensor (average), 20 MHz to 3.8 GHz, –30 to +20 dBm |
| JD734B | Terminating power sensor (peak), 20 MHz to 3.8 GHz, –30 to +20 dBm |
| JD736B | Terminating power sensor (peak and average), 20 MHz to 3.8 GHz, –30 to +20 dBm |
| MP-60A | USB optical power meter with software, 2.5 and 1.25 mm interfaces, 30-inch USB extender, and carrying pouch |
| MP-80A | USB optical power meter — high power, with software, 2.5 and 1.25 mm interfaces, 30-inch USB extender, and carrying pouch |
| FBP-SD101 | KIT: FBP-P5000i digital probe, FiberChekPRO software, case, and four tips |
| FIT-SD103 | KIT: FBP-P5000i digital probe, MP-60A USB power meter, FiberChekPRO software, case, tips, and adapters |
| G700050530 | RF cable DC to 8 GHz Type-N(m) to Type-N(m), 1.0 m |
| G700050531 | RF cable DC to 8 GHz Type-N(m) to Type-N(f), 1.5 m |
| G700050540 | Phase-stable RF cable with grip DC to 6 GHz Type-N(m) to Type-N(f), 1.5 m |
| GC72450522 | AC/DC power adapter for JD723C and JD724C only |
| G710550325 | Rechargeable LiON battery |
| G710550324 | External battery charger |
| JD72050541 | JD720C soft carrying case |
| JD70050542 | JD720 hard carrying case with wheels |
| JD70050343 | CellAdvisor backpack carrying case |
| JD70050006 | USB Bluetooth dongle and dipole antenna 5 dBi |
| JD70050008 | USB WiFi dongle |
| JD72050005 | USB GPS receiver |
| JD720C362 | JD720C series user's manual, printed version |
| JD723C/24C-EW | JD723C/724C warranty extension |
| JD723/24-CP2 | 1 Calibration over 2 year period for JD723C or JD724C |
| JD723/4-CAL | Certified Calibration for JD723/724 |
| JD720C100 | Certificate of calibration with test data for new instrument |