Overview
The VIAVI mOSW-C1 Optical Switch Module and mISW-C1 Optical Switch Tray are fourth-generation VIAVI instrumentation-class optical switches for manufacturing test automation. They bring the performance and repeatability of VIAVI's fixed-format 19-inch rack-mount switch systems to a modular plug-in or tray format. According to the manufacturer, this can cut the size of a switching system by up to 75%, and switching is 50% faster.
Both switches belong to the MAP series LightDirect module family. The mOSW-C1 plugs into MAP-200 and MAP-300 chassis and is optimized for 1x2, 2x2 and up to 1x24 channel counts. It comes as a single- or dual-slot module with bulkhead or 2 m pigtail connections. The mISW-C1 is intended for configurations with more than 24 channels. It is factory-mounted in a 2U MAP-202C chassis for up to 72 channels, or in a 4U MAP-204C chassis for 96 to 176 channels.
Optical design
The switches are available for single-mode, OM1 and OM3 multimode, and 1310 nm and 1550 nm polarization-maintaining fiber. They use an expanded-beam design instead of reflective MEMS switching. Large channel counts are not built by cascading switches, so insertion loss, PDL and repeatability stay the same regardless of switch size. In multimode versions, the expanded beam is modally transparent and preserves IEC-specified launch conditions. VIAVI specifies both the electro-mechanical switching time and the settling time to the final insertion loss.
Input types and options
There are four input types: single common input (1C), duplex (2D), dual parallel input (2E) and 2x2 crossover (2X). The Power Trim (PTRIM) option is available on single-mode 1C versions. It adds a bidirectional in-line power monitor on the common port and up to 20 dB of programmable loss on the connected path.
Control
The switches are controlled through a SCPI remote interface. It accepts MAP series commands and is backward compatible with VIAVI SB/SC series switches. The mOSW-C1 is a drop-in replacement for the older mLCS modules. The MAP GUI provides hover-and-release channel selection, switch topology diagrams and a programmable connection table. The chassis can be accessed through remote VNC, Ethernet, GPIB or the local GUI.
Models in this series
| Model | Description | |
|---|---|---|
| mISW-C1 |
VIAVI MAP mISW-C1 Optical Switch Tray for MAP-202C/MAP-204C Chassis
MAP series optical switch tray for high channel counts, with switch configurations up to 1x176 in a MAP-202C or MAP-204C chassis. |
Details → |
| mOSW-C1 |
VIAVI MAP mOSW-C1 Optical Switch Module for MAP-200/MAP-300 Chassis
Plug-in optical switch module for VIAVI MAP chassis, in 1x2 to 1x64 single-mode and multimode configurations for test automation. |
Details → |
Key Features
- All-optical switching independent of data rate and transmission format
- Low loss for all configurations from 1x2 to 1x176
- Switches are never cascaded; IL, PDL and repeatability are the same regardless of switch size
- 0.04 dB PDL and ±0.005 dB repeatability on single-input versions
- SCPI remote interface with MAP series commands or backward compatibility with VIAVI SB/SC series switches
- mOSW-C1 is a drop-in replacement for legacy mLCS modules
- Power Trim (PTRIM) option with bidirectional in-line power monitor and up to 20 dB programmable loss
- 1C, 2D (duplex), 2E (dual input) and 2X (2x2 crossover) input configurations
- Expanded-beam technology makes multimode switches modally transparent
- Single-mode, OM1 and OM3 multimode, and 1310/1550 nm polarization-maintaining fiber versions
- Bulkhead or 2 m pigtail terminations in single- or dual-width modules
- Up to eight 1x2 switches in a single-slot module
- Settling time to final insertion loss is specified
- Test reports supplied with guaranteed performance levels
- GUI with hover-and-release channel selection and programmable connection table
Specifications
| Single-mode (SM) |
1250 to 1650 nm
For IEC 60793-2-50 Type B1.3/ISO 11801 OS2 compliant fiber |
|---|---|
| Multimode (MM) |
760 to 1360 nm
For OM1 and OM3 fiber compliant with ISO/IEC 11801 |
|
Polarization Maintaining (PM) 1550 nm
1C |
1440 to 1650 nm |
|
Polarization Maintaining (PM) 1310 nm
1C |
1270 to 1650 nm |
| Insertion Loss (IL), Single-mode |
1C: 0.7 dB; 2D: 0.7 dB; 2E: 0.9 dB
Excluding connectors; tested at 1310 and 1650 nm with IEC 62614 ED1.0 2010-compliant EF |
|---|---|
| Insertion Loss (IL), Multimode |
1C: 0.9 dB; 2D: 0.9 dB; 2E: 1.0 dB
Excluding connectors; tested at 850 and 1300 nm with IEC 62614 ED1.0 2010-compliant EF |
|
Insertion Loss (IL), Polarization Maintaining
1C |
0.9 dB |
|
Extinction Ratio (PM), typical
1C |
18 dB |
|
Extinction Ratio (PM), minimum
1C |
15 dB |
| Return Loss (RL), Single-mode |
1C: 62 dB; 2D: 62 dB; 2E: 60 dB
Excluding connectors, 2 m pigtail; tested at 1310/1625 nm |
| Return Loss (RL), Multimode OM1 (62.5 µm) |
1C: 30 dB; 2D: 30 dB; 2E: 25 dB
Tested at 850/1300 nm |
| Return Loss (RL), Multimode OM3 (50 µm) |
1C: 40 dB; 2D: 40 dB; 2E: 35 dB
Tested at 850/1300 nm |
| Polarization-dependent Loss (PDL) |
1C: 0.04 dB; 2D: 0.05 dB; 2E: 0.07 dB
Tested at 1310 and 1650 nm |
| Repeatability, sequential switching |
1C: ±0.005 dB; 2D: ±0.01 dB; 2E: ±0.01 dB
Measured between two consecutive readings over 100 cycles |
| Repeatability, random switching |
1C: ±0.025 dB; 2D: ±0.04 dB; 2E: ±0.04 dB
Measured between two consecutive readings over 100 cycles |
| IL Stability (maximum) |
±0.025 dB
Drift relative to reference channel at ±3°C ambient deviation over 7 days (168 hours) |
| Crosstalk (maximum), Single-mode | –80 dB |
| Crosstalk (maximum), Multimode | –60 dB |
| Max Input Power (optical) | 300 mW |
| Lifetime | 100 million switching cycles |
| Electro-mechanical (break to make SM/MM) | ≤ 24 ports: 20+10*(N–1) ms; >24 ports < 72: 55+30*(N–1) ms; >72 ports: 35+11*(N–1) ms |
|---|---|
| Electro-mechanical (break to make PM) |
30+20*(N–1) ms
≤ 24 ports |
| Settling Time to 90% Final IL | ≤ 24 ports: 60 ms; >24 ports < 72: 70 ms; >72 ports: 90 ms |
| Settling Time for 99% Final IL | ≤ 24 ports: 90 ms; >24 ports < 72: 120 ms; >72 ports: 200 ms |
|
Availability
PTRIM |
1CxN with <72 ports
The datasheet text on page 5 says fewer than 80 ports; the spec table says <72. Not available for 1C002. |
|---|---|
|
Additional IL
PTRIM |
0.6 dB |
|
Return Loss
PTRIM |
55 dB |
|
Additional Through Path PDL
PTRIM |
0.02 dB |
|
Power Measurement Range
PTRIM |
+10 to –55 dBm (1550 nm) |
|
Power Trim Range
PTRIM |
20 dB
typical |
|
Power Trim Index
PTRIM |
0 to 16 (≤ 24 ports); 0 to 32 (>24 ports)
All specifications are presented for PTRIM index set to zero |
|
Wavelength Range, Single-mode (SM)
1x2, 2x2 |
1290 to 1330 nm and 1520 to 1650 nm |
|---|---|
|
Wavelength Range, Multimode (MM)
1x2, 2x2 |
760 to 1360 nm |
|
Insertion Loss (IL), Single-mode
1x2, 2x2 |
1x2: 0.7 dB; 2x2: 1.2 dB
Excluding connectors |
|
Insertion Loss (IL), Multimode
1x2, 2x2 |
1x2: 0.9 dB; 2x2: 1.2 dB
Excluding connectors |
|
Return Loss (RL), Single-mode
1x2, 2x2 |
50 dB |
|
Return Loss (RL), Multimode OM1 (62.5 µm)
1x2, 2x2 |
1x2: 30 dB; 2x2: 25 dB |
|
Return Loss (RL), Multimode OM3 (50 µm)
1x2, 2x2 |
1x2: 40 dB; 2x2: 35 dB |
|
Polarization-dependent Loss (PDL)
1x2, 2x2 |
1x2: 0.07 dB; 2x2: 0.08 dB
Tested at 1310 and 1650 nm |
|
Repeatability
1x2, 2x2 |
1x2: ±0.02 dB; 2x2: ±0.03 dB
Measured between two consecutive readings over 100 cycles |
|
IL Stability (maximum)
2x2 |
±0.025 dB |
|
Crosstalk (maximum)
1x2, 2x2 |
–55 dB
Single-mode and multimode |
|
Max Input Power (optical)
1x2, 2x2 |
300 mW |
|
Lifetime
1x2, 2x2 |
100 million switching cycles |
|
Electro-mechanical switching (break to make)
1x2, 2x2 |
Single-Mode: 4 ms; Multimode: 210 ms |
|
Settling Time for 90% Final IL
1x2, 2x2 |
Single-Mode: 2 ms; Multimode: 60 ms |
|
Settling Time for 99% Final IL
1x2, 2x2 |
Single-Mode: 4 ms; Multimode: 90 ms |
| Operation Temperature | 0 to 50°C |
|---|---|
| Operation Humidity | 15 to 80% RH, 0 to 40°C noncondensing |
| Storage Temperature |
–30 to 60°C
Noncondensing for 1x2/2x2 |
| Safety |
CE, CSA/UL/IEC61010-1, and LXI Class C
When installed in a MAP series chassis |
|
Dimensions (W x H x D), single slot
mOSW-C1 |
4.1 x 13.3 x 37.0 cm (1.6 x 5.2 x 14.6 in) |
|---|---|
|
Dimensions (W x H x D), dual slot
mOSW-C1 |
8.1 x 13.3 x 37.0 cm (3.2 x 5.2 x 14.6 in) |
|
Weight, single slot with pigtails
mOSW-C1 |
1.75 kg (3.14 lb) |
|
Weight, dual slot with pigtails
mOSW-C1 |
3.1 kg (6.14 lb) |
|
Pigtail length on units with pigtails
mOSW-C1 |
2 m |
|
Chassis compatibility
mOSW-C1 |
Compatible with all current MAP-300 and MAP-200 chassis |
|
Dimensions (W x H x D), MAP-202C 2U (< 72 ports)
mISW-C1 |
444 x 88.2 x 386.5 mm (17.5 x 3.5 x 15.2 in) |
|---|---|
|
Dimensions (W x H x D), MAP-204C 4U (> 72 ports)
mISW-C1 |
444 x 177 x 386.5 mm (17.5 x 7 x 15.2 in) |
|
Weight, MAP-202C 2U
mISW-C1 |
13 kg (28.7 lb) |
|
Weight, MAP-204C 4U
mISW-C1 |
20 kg (44.1 lb) |
|
Chassis requirement
mISW-C1 |
MAP-202C required for channel counts from 24 to 72; MAP-204C required for channel counts from 96 to 176
Tray is factory-mounted in the chassis |
|
Part number structure
mOSW-C1 |
mOSW-C1ABBCCCDE-MXXX-MYY |
|---|---|
|
A – independent switches per module
mOSW-C1 |
1, 2, or 4
Configuration tables also list eight 1x2 switches per module |
|
BB – switch/input type
mOSW-C1 |
1C, 2D, 2E, 2X
2D part numbers indicate switchable output states; physical outputs are 2X the number of states |
|
CCC – number of outputs
mOSW-C1 |
from 002 to 064 |
|
D – termination
mOSW-C1 |
B for bulkhead, P for 2m pigtails |
|
E – options
mOSW-C1 |
0 = no option, 1 = Power Trim option, H = High Directivity
High Directivity only for 1C002 and 2X002 with 9µm single-mode fiber |
Applications
- Test system automation for multi-port components, modules and line cards
- Complex manufacturing test sequencing
- Multifiber connector testing paired with the MAP series mORL-A1 module
- Long-term reliability testing
- Passive component, transponder and line card manufacturing test
- Transmission and BER testing with multimode fiber
Options & Accessories
| Option | Description |
|---|---|
| M100 | Fiber type: 9µm Single Mode |
| M101 | Fiber type: 50µm (OM3) |
| M102 | Fiber type: 62.5µm (OM1) |
| M105 | Fiber type: 100µm — Available only for bulkhead termination |
| MFP | Connector: FC/PC |
| MFA | Connector: FC/APC |
| MSC | Connector: SC/PC |
| MSU | Connector: SC/APC |
| MLC | Connector: LC/PC |
| MLU | Connector: LC/APC |
| 1 | Power Trim option (PTRIM) — Only for 1C switches with 9µm single-mode fiber, except 1C002 |
| H | High Directivity option — Only for 1C002 and 2X002 switches with 9µm single-mode fiber |
| MBIDTEST1-012 | Bidirectional test report for single switch with 4 to 12 ports |
| MBIDTEST2-102 | Bidirectional test report for dual switch with 4 to 12 ports |
| MBIDTEST1-024 | Bidirectional test report for single switch with 13 to 24 ports |
| MBIDTEST2-024 | Bidirectional test report for dual switch with 13 to 24 ports |
| MOSW-C111C004BE-MXXX-MYY | 1Cx04, one switch, bulkhead |
| MOSW-C111C008BE-MXXX-MYY | 1Cx08, one switch, bulkhead |
| MOSW-C111C012BE-MXXX-MYY | 1Cx12, one switch, bulkhead |
| MOSW-C111C024BE-MXXX-MYY | 1Cx24, one switch, bulkhead |
| MOSW-C111C008PE-MXXX-MYY | 1Cx08, one switch, 2m pigtail |
| MOSW-C111C012PE-MXXX-MYY | 1Cx12, one switch, 2m pigtail |
| MOSW-C111C024PE-MXXX-MYY | 1Cx24, one switch, 2m pigtail |
| MOSW-C111C032PE-MXXX-MYY | 1Cx32, one switch, 2m pigtail |
| MOSW-C111C048PE-MXXX-MYY | 1Cx48, one switch, 2m pigtail |
| MOSW-C111C064PE-MXXX-MYY | 1Cx64, one switch, 2m pigtail |
| MOSW-C112D002B0-MXXX-MYY | 2Dx02 duplex, one switch, bulkhead |
| MOSW-C112D004B0-MXXX-MYY | 2Dx04 duplex, one switch, bulkhead |
| MOSW-C112D006B0-MXXX-MYY | 2Dx06 duplex, one switch, bulkhead |
| MOSW-C112D012B0-MXXX-MYY | 2Dx12 duplex, one switch, bulkhead |
| MOSW-C112D004P0-MXXX-MYY | 2Dx04 duplex, one switch, 2m pigtail |
| MOSW-C112D006P0-MXXX-MYY | 2Dx06 duplex, one switch, 2m pigtail |
| MOSW-C112D012P0-MXXX-MYY | 2Dx12 duplex, one switch, 2m pigtail |
| MOSW-C112D016P0-MXXX-MYY | 2Dx16 duplex, one switch, 2m pigtail |
| MOSW-C112D024P0-MXXX-MYY | 2Dx24 duplex, one switch, 2m pigtail |
| MOSW-C112D032P0-MXXX-MYY | 2Dx32 duplex, one switch, 2m pigtail |
| MOSW-C112E004B0-MXXX-MYY | 2Ex04 dual input, one switch, bulkhead |
| MOSW-C112E008B0-MXXX-MYY | 2Ex08 dual input, one switch, bulkhead |
| MOSW-C112E012B0-MXXX-MYY | 2Ex12 dual input, one switch, bulkhead |
| MOSW-C112E024B0-MXXX-MYY | 2Ex24 dual input, one switch, bulkhead |
| MOSW-C112E008P0-MXXX-MYY | 2Ex08 dual input, one switch, 2m pigtail |
| MOSW-C112E012P0-MXXX-MYY | 2Ex12 dual input, one switch, 2m pigtail |
| MOSW-C112E024P0-MXXX-MYY | 2Ex24 dual input, one switch, 2m pigtail |
| MOSW-C112E032P0-MXXX-MYY | 2Ex32 dual input, one switch, 2m pigtail |
| MOSW-C112E048P0-MXXX-MYY | 2Ex48 dual input, one switch, 2m pigtail |
| MOSW-C112E064P0-MXXX-MYY | 2Ex64 dual input, one switch, 2m pigtail |
| MOSW-C121C004BE-MXXX-MYY | 1Cx04, two switches, bulkhead |
| MOSW-C121C012BE-MXXX-MYY | 1Cx12, two switches, bulkhead |
| MOSW-C121C008PE-MXXX-MYY | 1Cx08, two switches, pigtail |
| MOSW-C121C012PE-MXXX-MYY | 1Cx12, two switches, pigtail |
| MOSW-C121C024PE-MXXX-MYY | 1Cx24, two switches, pigtail |
| MOSW-C122D002B0-MXXX-MYY | 2Dx02 duplex, two switches, bulkhead |
| MOSW-C122D004P0-MXXX-MYY | 2Dx04 duplex, two switches, pigtail |
| MOSW-C122D006P0-MXXX-MYY | 2Dx06 duplex, two switches, pigtail |
| MOSW-C122D012P0-MXXX-MYY | 2Dx12 duplex, two switches, pigtail |
| MOSW-C122E004B0-MXXX-MYY | 2Ex04 dual input, two switches, bulkhead |
| MOSW-C122E008P0-MXXX-MYY | 2Ex08 dual input, two switches, pigtail |
| MOSW-C122E012P0-MXXX-MYY | 2Ex12 dual input, two switches, pigtail |
| MOSW-C122E024P0-MXXX-MYY | 2Ex24 dual input, two switches, pigtail |
| MOSW-C111C002BE-MXXX-MYY | 1x2, one switch, bulkhead |
| MOSW-C112X002BE-MXXX-MYY | 2x2 (2X), one switch, bulkhead |
| MOSW-C121C002BE-MXXX-MYY | 1x2, two switches |
| MOSW-C122X002BE-MXXX-MYY | 2x2 (2X), two switches |
| MOSW-C141C002B0-M100-MYY | 1x2, four switches |
| MOSW-C142X002P0-M100-MYY | 2x2 (2X), four switches, pigtail |
| MOSW-C181C002P0-M100-MYY | 1x2, eight switches |