VIAVI MAP mORL-A1 MORL-A13456-BID-M100-MFA Single-Mode Bidirectional IL/RL Meter, 1310/1490/1550/1625 nm
Four-wavelength single-mode bidirectional insertion loss and return loss meter module with FC/APC interface for the VIAVI MAP-Series PCT system.
- Wavelengths (4-Wavelength Version)
- 1310, 1490, 1550, 1625 nm
- Output connector
- FC/APC
Overview
The VIAVI MORL-A13456-BID-M100-MFA is a single-mode IL/RL meter in the mORL-A1 module family, which forms the core of the VIAVI Passive Component/Connector Test (PCT) solution for the MAP-Series platform. This version has four sources (1310, 1490, 1550 and 1625 nm), works with 9 µm single-mode fiber, has an FC/APC interface and supports bidirectional testing.
Measurement principle
Insertion loss is measured with the power meter method. Launch power monitoring and depolarization technology give 0.001 dB display resolution. Return loss is measured with time-domain technology, so it is mandrel-free and runs in parallel with IL using the same optical stimulus. The time-domain method also measures DUT length. According to VIAVI, the mORL-A1 has 80 dB of RL dynamic range and can measure jumpers as short as 70 cm in as little as 6 seconds for two wavelengths.
Bidirectional testing
The bidirectional (BID) configuration adds an internal 2x2 switch to the module. Together with time-domain RL measurement and the multiple programmable window function, this switch lets the module measure RL on both connectors of a jumper with a single connection. As a result, the jumper does not need to be tested in the reverse direction.
Software and integration
The module is controlled by the PCT application on the MAP chassis, which is offered as PCT Max and PCT Lite. It has three modes: instrument mode, script (DUT-aware) mode with a local database, and port mapping. Full SCPI remote control is available over LAN or GPIB. The module is often used together with the MAP Optical Switch (mOSW/mISW) and Remote Optical Power Meter (mOPM) modules to test multifiber and high-channel-count assemblies.
Key Features
- Four sources: 1310, 1490, 1550 and 1625 nm
- Bidirectional testing via internal 2x2 switch
- FC/APC output connector, 9 µm single-mode fiber
- Mandrel-free time-domain return loss measurement with length measurement
- IL and RL measured in parallel using the same optical stimulus
- 0.001 dB insertion loss display resolution
- Scalable modular platform
- Small footprint - 25% of competing solutions
- Integrated automation via SCPI and no-code scripting
- Database interface and report generation
- MPO and MTP capable with simultaneous polarity measurement
- Growth enabling - 1 to 1,000+ DUT channels
- FastIL insertion-loss-only mode for prescreening
- Port mapping verifies multifiber MPO cassette continuity and polarity in less than 15 seconds
Specifications
| Wavelengths (4-Wavelength Version) | 1310, 1490, 1550, 1625 nm |
|---|---|
| Output connector |
FC/APC
Bidirectional
|
| Single Fiber | Single-Mode 9 µm core |
|---|
| Initializing Time | < 4s |
|---|---|
| Averaging Options Per Wavelength |
0.5, 1, 2, 5, 10s
The older MAP-Based IL/RL data sheet lists 2, 5, 10s
|
| Total Time (IL, RL, Polarity) for 2 wavelengths |
23s (12 channels), 44s (24 channels)
With mOPM-C1RHPM Remote Head Polarity Mapper
|
| Display Resolution | 0.001 dB |
|---|---|
| Total IL Uncertainty |
± 0.02 dB
After valid zero loss, total expanded uncertainty (2σ), reconnecting the same connector and OPM adaptor, temperature ±1°C, using internal source; IL uncertainty from launching condition not included
|
| Additional Uncertainties Due to 1xN Switching |
± 0.01 dB
If mOSW-C1 added
|
| Additional Uncertainties Due to Fiber Position in the Integrating Sphere |
± 0.03 dB
24-channel ribbon fiber
|
| Display Resolution | 0.01 dB |
|---|---|
| RL Dynamic Range | 80 dB |
| DUT Length, DUT reflections (both ends) < 40 dB | > 170 cm |
| DUT Length, DUT reflections (both ends) > 40 dB | > 70 cm |
| Return Loss Repeatability, 30 to 65 dB |
± 0.1 dB
5 s averaging time and 200 m range; 10 measurements with a stable connection of a 3 m patch cord
|
| Return Loss Repeatability, 65 to 70 dB |
± 0.2 dB
5 s averaging time and 200 m range; 10 measurements with a stable connection of a 3 m patch cord
|
| Return Loss Repeatability, 70 to 75 dB |
± 0.4 dB
5 s averaging time and 200 m range; 10 measurements with a stable connection of a 3 m patch cord
|
| Return Loss Repeatability, 75 to 80 dB |
± 1.5 dB
5 s averaging time and 200 m range; 10 measurements with a stable connection of a 3 m patch cord
|
| Return Loss Accuracy, 30 to 70 dB |
± 1.0 dB
5 s averaging time and 200 m range
|
| Return Loss Accuracy, 70 to 75 dB |
± 1.7 dB
5 s averaging time and 200 m range
|
| Return Loss Accuracy, 75 to 80 dB |
± 3.0 dB
5 s averaging time and 200 m range
|
| Time Penalty Measuring IL/RL |
0s
Requires MAP-300 FW 13.0+ with PCT
|
|---|---|
| Prescreening with FastIL | 0.2s per channel |
| Multi Fiber | All connector formats – MPO, MXC, SN-MT, FAU types, Proprietary Lensed Connectors, Multicore |
| Minimum Resolvable Fiber Pitch | 30 μm |
| Maximum Tolerance for IL in Polarity | > 20 dB |
| Accuracy Impact (RL) | 0 dB |
| Accuracy Impact (IL, compared to RHIP) | 0 dB |
| Recalibration Period | 1 year |
|---|---|
| Compliance |
CE, CSA/UL/IEC61010-1, and LXI Class C
MAP mORL-A1 modules installed in a MAP Series chassis
|
| Warm-up Time | 20 min |
|---|---|
| Operating Temperature, Humidity | 25 ± 5°C non-condensing humidity |
| Storage Temperature | - 30 to + 60°C |
| Size (W x H x D) | 4.06 x 13.26 x 37.03 cm (1.6 x 5.22 x 14.58 in) |
|---|---|
| Weight |
1.2 kg (2.65 lb)
Approximately
|
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- IL, RL and length testing of optical connectors and cable assemblies
- Structured-cabling solution testing
- Optical splitter testing
- Automated testing of multifiber assemblies such as MPO
- Verifying continuity and polarity of large multifiber assemblies
- Measuring RL of line cards and receptacle-based transponders
Options & Accessories
| Option | Description |
|---|---|
| MSUP-300A-FIT | MAP-300 fiber connector inspection app — Requires probe |
| MSUP-300A-PCTMAPPING | MAP-300 PCT polarity and port mapping application add-on |
| MSUP-300A-PCTREMDB | MAP-300 PCT remote centralized database connection key |
| MSUP-300A-SBSC | MAP-300 PCT driver for legacy SB/SC series switches |
| MSUP-300A-PCT-TDR | MAP-300 Enhanced PCT TDR License |
| MSUP-300A-PCTCASCADE | MAP-300 PCT Switch Cascade |
| MSUP-300A-PCTLOGGING | MAP-300 PCT Continuous Mode Logging License |
| MSUP-300A-SEIL | MAP-300 Single Ended Insertion Loss license |
| MSUP-FIT | MAP-200 Super Application Fiber Inspection (FIT) |
| MSUP-PCTMAPPING | MAP-200 Super Application PCT Mapping |
| MSUP-PCTREMDB | MAP-200 CT Remote Database Connection Key |
| MSUP-SBSC | MAP-200 driver for legacy SB/SC series switches |
| MOSW-C111C004B0-MXXX-MYY | Single 1 x 4 switch, bulkheads — XXX = fiber type code, YY = connector type code |
| MOSW-C111C008B0-MXXX-MYY | Single 1 x 8 switch, bulkheads — XXX = fiber type code, YY = connector type code |
| MOSW-C111C012B0-MXXX-MYY | Single 1 x 12 switch, bulkheads (Dual width module) — XXX = fiber type code, YY = connector type code |
| MOSW-C111C024B0-MXXX-MYY | Single 1 x 24 switch, bulkheads (Dual width module) — XXX = fiber type code, YY = connector type code |
| MOPM-C1RH1 | Single channel remote interface cassette |
| MOPM-C1RH2 | Dual channel remote interface cassette |
| MOPM-C1RH4 | Quad channel remote interface cassette |
| MOPM-C1RHPCT | 2mm InGaAs PCT system remote head |
| MOPM-C1RHIP | Integrated PCT system remote head |
| MOPM-C1RHPM | Remote Head Polarity Mapper — Simultaneous IL/RL/Polarity remote head; requires MOPM-C1RH1 base cassette |
| AC500 | FC/PC-FC/PC Universal Connector Adapter — Replacement mating sleeve |
| AC501 | FC/PC-SC/PC Universal Connector Adapter — Replacement mating sleeve |
| AC502 | FC/APC-FC/APC Universal Connector Adapter — Replacement mating sleeve |
| AC503 | FC/APC-SC/APC Universal Connector Adapter — Replacement mating sleeve |