VIAVI MAP-Series platform family with mORL IL/RL modules, fiber inspection probe and microscope
VIAVI / mORL-A1 / IL/RL Test Modules
MORL-A11308-STD-M112-MFA

VIAVI mORL-A1 MORL-A11308-STD-M112-MFA Multimode IL/RL Meter 850/1300 nm Dual Output OM3/OM1 FC/APC

MAP-Series multimode IL/RL meter module at 850/1300 nm with dual OM3/OM1 output and FC/APC connectors for passive component testing.

Wavelengths
850, 1300 nm
Datasheet

Overview

The MORL-A11308-STD-M112-MFA is a multimode insertion loss (IL) and return loss (RL) meter module from the VIAVI mORL-A1 family. It operates at 850 nm and 1300 nm, has a dual output for 50 µm (OM3) and 62.5 µm (OM1) fiber with software selection between the two, and uses FC/APC connectors. This is the standard (non-bidirectional) version of the dual-fiber multimode module.

The module is part of the VIAVI Passive Component/Connector Test solution (PCT), a family of modules, software and peripherals for testing insertion loss, return loss, physical length and polarity of optical connectivity products such as connectors, cable assemblies, structured cabling and splitters. It installs in a MAP-Series chassis and can be configured for R&D, production or qualification test environments.

Measurement principle

The multimode module uses the same basic technology and architecture as the single-mode mORL-A1. It has an integrated power meter, and IL is measured with the power meter method. RL is measured with time-domain technology, which avoids mandrel terminations. RL can be measured from 15 to 60 dB, concurrently with IL measurements, in less than 2 s per wavelength. IL performance meets the IEC 61280-4-1 recommendations for mode fill. Besides the laser sources used for both IL and RL, the module includes low-power LED sources. These have lower coherence and no polarization, which reduces speckle-related instability at the power meter. Launch power monitoring gives an IL stability of ±0.02 dB.

Software and system integration

The PCT application runs on the MAP chassis in PCT Max and PCT Lite versions. It offers instrument mode, script (DUT-aware) mode with a results database, and port mapping, and a full set of SCPI remote commands is available over LAN or GPIB. The mORL is often combined with MAP optical switch (mOSW/mISW) and remote optical power meter (mOPM) modules to expand channel count and to verify polarity on multifiber assemblies.

Key Features

  • Dual output for 50 µm (OM3) and 62.5 µm (OM1) multimode fiber, software selectable
  • 850 nm and 1300 nm sources
  • LED or laser IL modes, software selectable
  • Multimode IL meets IEC 61280-4-1 Encircled Flux requirements
  • Time-domain (mandrel-free) RL measurement in parallel with IL
  • Integrated power meter
  • Scalable modular platform
  • Small footprint - 25% of competing solutions
  • Integrated automation via SCPI and no-code scripting
  • Database interface and report generation
  • MPO and MTP capable with simultaneous polarity measurement
  • Growth enabling - 1 to 1,000+ DUT channels
  • Port mapping verifies multifiber MPO cassette continuity and polarity in less than 15 seconds
  • FC/APC connector interface

Specifications

Source
Wavelengths 850, 1300 nm
2-wavelength version, multimode mORL-A1
Fiber Types
Dual Fiber 50 µm core (OM3) and 62.5 µm core (OM1). Software selectable
Connector FC/APC
Per ordering description: Dual Output OM3/OM1 MMF FC/APC
Measurement Time
Initializing Time < 4s
Averaging Options Per Wavelength 0.5, 1, 2, 5, 10s
Earlier MAP-based IL/RL data sheet lists 2, 5, 10s
Total Time (IL, RL, Polarity) for 2 wavelengths 23s (12 channels), 44s (24 channels)
Polarity measurement with mOPM-C1RHPM Remote Head Polarity Mapper
RL measurement time (concurrent with IL) less than 2s per wavelength
Multimode module, RL from 15 to 60 dB
Insertion Loss
Modes LED or laser (software selectable)
Display Resolution 0.001 dB
Total IL Uncertainty ± 0.05 dB
After valid zero loss, total expanded uncertainty (2σ), reconnecting the same connector and OPM adaptor, temperature ±1°C, using internal source (incl. LED mode); IL uncertainty from launching condition not included
Additional Uncertainties Due to 1xN Switching ± 0.01 dB
If mOSW-C1 added
Additional Uncertainties Due to Fiber Position in the Integrating Sphere ± 0.03 dB
24-channel ribbon fiber
IL Stability ±0.02 dB
Achieved through launch power monitoring
Return Loss
Display Resolution 0.01 dB
RL Measurement Range 15 to 60 dB
Multimode module
DUT Length, DUT reflections (both ends) < 40 dB > 170 cm
DUT Length, DUT reflections (both ends) > 40 dB > 70 cm
Return Loss Repeatability, 15 to 60 dB ± 0.2 dB
At 5 s averaging time and 200 m range; 10 measurements with a stable connection of a 3 m patch cord
Return Loss Repeatability, 60 to 70 dB ± 0.5 dB
At 5 s averaging time and 200 m range; 10 measurements with a stable connection of a 3 m patch cord
Return Loss Accuracy, 15 to 20 dB ± 1.8 dB
At 5 s averaging time and 200 m range
Return Loss Accuracy, 20 to 60 dB ± 1.3 dB
At 5 s averaging time and 200 m range
Recalibration Period 1 year
Compliance
Safety and Interface CE, CSA/UL/IEC61010-1, and LXI Class C requirements
MAP mORL-A1 modules installed in a MAP Series chassis
Multimode IL Meets IEC 61280-4-1 Encircled Flux requirements
Environmental
Warm-up Time 20 min
Operating Temperature, Humidity 25 ± 5°C non-condensing humidity
Storage Temperature - 30 to + 60°C
Physical
Size (W x H x D) 4.06 x 13.26 x 37.03 cm (1.6 x 5.22 x 14.58 in)
Weight 1.2 kg (2.65 lb)
Approximately

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • IL, RL and length testing of optical connectors and cable assemblies
  • Structured-cabling solution testing
  • Optical splitter testing
  • Multimode fiber-based device testing
  • Automated testing of multifiber assemblies such as MPO
  • Verifying continuity and polarity of large multifiber assemblies
  • Measuring RL of line cards and receptacle-based transponders

Options & Accessories

Option Description
MSUP-300A-FIT MAP-300 fiber connector inspection app — Requires probe
MSUP-300A-PCTMAPPING MAP-300 PCT polarity and port mapping application add-on
MSUP-300A-PCTREMDB MAP-300 PCT remote centralized database connection key
MSUP-300A-SBSC MAP-300 PCT driver for legacy SB/SC series switches
MSUP-BIDIUPG MAP-300 mORL Bi-di upgrade license — Requires high directivity mOSW 2x2
MSUP-300A-PCT-TDR MAP-300 Enhanced PCT TDR License
MSUP-300A-PCTCASCADE MAP-300 PCT Switch Cascade
MSUP-300A-PCTLOGGING MAP-300 PCT Continuous Mode Logging License
MSUP-300A-SEIL MAP-300 Single Ended Insertion Loss license
MSUP-FIT MAP-200 Super Application Fiber Inspection (FIT)
MSUP-PCTMAPPING MAP-200 Super Application PCT Mapping
MSUP-PCTREMDB MAP-200 CT Remote Database Connection Key
MSUP-SBSC MAP-200 driver for legacy SB/SC series switches
MOSW-C111C004B0-MXXX-MYY Single 1 x 4 switch, bulkheads — XXX = fiber type code, YY = connector type code
MOSW-C111C008B0-MXXX-MYY Single 1 x 8 switch, bulkheads — XXX = fiber type code, YY = connector type code
MOSW-C111C012B0-MXXX-MYY Single 1 x 12 switch, bulkheads (Dual width module) — XXX = fiber type code, YY = connector type code
MOSW-C111C024B0-MXXX-MYY Single 1 x 24 switch, bulkheads (Dual width module) — XXX = fiber type code, YY = connector type code
MOPM-C1RH1 Single channel remote interface cassette
MOPM-C1RH2 Dual channel remote interface cassette
MOPM-C1RH4 Quad channel remote interface cassette
MOPM-C1RHPCT 2mm InGaAs PCT system remote head
MOPM-C1RHIP Integrated PCT system remote head
MOPM-C1RHPM Remote Head Polarity Mapper — Requires MAP-300 FW 13.0+ with PCT
AC500 FC/PC-FC/PC Universal Connector Adapter — Mating sleeve replacement part
AC501 FC/PC-SC/PC Universal Connector Adapter — Mating sleeve replacement part
AC502 FC/APC-FC/APC Universal Connector Adapter — Mating sleeve replacement part
AC503 FC/APC-SC/APC Universal Connector Adapter — Mating sleeve replacement part

Documents & Resources

Insertion Loss/Return Loss Testing (mORL)
datasheet · PDF
MAP-Based Insertion Loss/ Return Loss Testing Solution
datasheet · PDF
MAP Series PCT Enhanced TDR
datasheet · PDF
mOPM-C1RHPM Remote Head Polarity Mapper
datasheet · PDF
Multiple Application Platform
datasheet · PDF
Novel Insertion Loss Measurements VIAVI PCT Enhanced TDR
app note · PDF
Comparing Optical Return Loss (ORL) Measurement Methods
app note · PDF
New Passive Component/Connector Test (PCT) for the MAP-300
other
Introduction to Insertion Loss Measurements
app note · PDF
The Skeleton in Your Closet: EF Compliance Impact on Insertion Loss Testing
app note · PDF
Future Proofing Your IL/RL Testing
brochure · PDF
PCT System now available on MAP-300
other
How-To Videos: MAP-220 | PCT-rm
other
Low-Loss Requirements Drive Changes in Measurement Designs
app note · PDF
Measurement Integrity in IL/RL Testing
app note · PDF
MAP-202, MAP-204, MAP-220 Software
software
MAP-230, MAP-280 Software
software
Passive Component/Connector Test Solution
brochure · PDF
Inspection, Cleaning and Test Solutions for CS, SN, and MDC Fiber Connectors
brochure · PDF
Inspection, Cleaning and Test Solutions for MMC Connectors and TMT Ferrule Technology
brochure · PDF
MAP Series: Power Meter AC Detector Adaptors
brochure · PDF
Optical Manufacturing and Test Platform Catalog
brochure · PDF
VIAVI PCT Calibration
other · PDF
MAP-300 DUT Setup with PCTlite
other
High-Speed Fiber Array Unit (FAU) Testing with MAP-300
app note · PDF
Easy Environmental and Shock Testing of Optical Passive Components
brochure · PDF
FastIL: Revolutionizing Connectivity Testing
brochure · PDF
Testing, Inspection and Cleaning Solutions for Optical Connector Manufacturers
brochure · PDF
Universal Connector/Adapter System
brochure · PDF
FVAi-2030 Benchtop Microscope: Overview
other
Solutions Overview for Optical Connector Manufacturers
other