VIAVI MAP-Series platform family with mORL IL/RL test modules, fiber inspection probe and microscope
MORL-A11308-STD-M101-MFA

MAP PCT mORL-A1 MORL-A11308-STD-M101-MFA Multimode IL/RL Meter, 850/1300 nm, 50 µm OM3, FC/APC

Multimode mORL-A1 IL/RL meter module for the MAP-Series, 850/1300 nm sources, 50 µm OM3 fiber and FC/APC output.

Wavelengths
850, 1300 nm
Output connector
FC/APC
Datasheet

Overview

The VIAVI MORL-A11308-STD-M101-MFA is the standard (unidirectional) multimode version of the mORL-A1 insertion loss and return loss meter. It provides 850 nm and 1300 nm sources for 50 µm OM3 multimode fiber with an FC/APC output and installs in a MAP-Series chassis as part of the VIAVI Passive Component/Connector Test (PCT) solution.

The PCT solution is a family of modules, software and peripherals for testing insertion loss (IL), return loss (RL), physical length and polarity of optical connectivity products such as connectors, cable assemblies, structured-cabling solutions and optical splitters. It can be configured for R&D, production or qualification test environments.

Measurement principle

The multimode module uses the same basic technology and architecture as the single-mode mORL-A1. IL is measured using the power meter method, and RL is measured in parallel using time-domain technology, often called mandrel-free RL. The multimode module includes a standard set of low-power LED sources in addition to the laser sources; the LED sources offer lower coherence without polarization, removing instability from speckle effects on the power meter surface. Multimode IL performance meets the IEC 61280-4-1 Encircled Flux recommendations for mode fill.

Software and system integration

The PCT application runs natively on the MAP chassis in PCT Max and PCT Lite versions, with instrument mode, script (DUT aware) mode and port mapping. A full set of SCPI remote commands is available over LAN or GPIB. The mORL is often combined with MAP optical switch (mOSW-C1) modules and remote optical power meter heads (mOPM), and a bidirectional upgrade license is available that requires a high-directivity mOSW 2x2 switch.

Key Features

  • Multimode IL/RL meter with 850 nm and 1300 nm sources
  • 50 µm OM3 multimode fiber with FC/APC output
  • LED or laser IL modes, software selectable
  • 0.001 dB IL display resolution
  • Mandrel-free time-domain RL measurement concurrent with IL
  • Multimode IL meets IEC 61280-4-1 Encircled Flux requirements
  • Scalable modular MAP-Series platform
  • Small footprint - 25% of competing solutions
  • Integrated automation via SCPI and no-code scripting
  • Database interface and report generation
  • MPO and MTP capable with simultaneous polarity measurement
  • Growth enabling - 1 to 1,000+ DUT channels
  • FastIL prescreening at 0.2 s per channel

Specifications

Source
Wavelengths 850, 1300 nm
2-wavelength version (multimode mORL-A1)
Output connector FC/APC
Fiber Types
Single fiber 50 µm core (OM3)
Measurement Time
Initializing time < 4s
Averaging options per wavelength 0.5, 1, 2, 5, 10s
Earlier MAP-Based IL/RL data sheet lists 2, 5, 10s
Total time (IL, RL, polarity) for 2 wavelengths 23s (12 channels), 44s (24 channels)
With mOPM-C1RHPM Remote Head Polarity Mapper
Prescreening with FastIL 0.2s per channel
Insertion Loss
Modes LED or laser (software selectable)
Display resolution 0.001 dB
Total IL uncertainty ± 0.05 dB
For LED mode, after valid zero loss, total expanded uncertainty (2σ), reconnecting the same connector and OPM adaptor, temperature ±1°C, using internal source; IL uncertainty from launching condition not included
Additional uncertainty due to 1xN switching ± 0.01 dB
If mOSW-C1 added
Additional uncertainty due to fiber position in the integrating sphere ± 0.03 dB
24-channel ribbon fiber
Return Loss
Display resolution 0.01 dB
Minimum DUT length, DUT reflections (both ends) < 40 dB > 170 cm
Minimum DUT length, DUT reflections (both ends) > 40 dB > 70 cm
Return loss repeatability, -15 to 60 dB ± 0.2 dB
5 s averaging time, 200 m range; 10 measurements with a stable connection of a 3 m patch cord
Return loss repeatability, -60 to 70 dB ± 0.5 dB
5 s averaging time, 200 m range; 10 measurements with a stable connection of a 3 m patch cord
Return loss accuracy, -15 to 20 dB ± 1.8 dB
5 s averaging time, 200 m range
Return loss accuracy, -20 to 60 dB ± 1.3 dB
5 s averaging time, 200 m range
RL measurement range 15 to 60 dB
Achievable during concurrent IL measurements in less than 2s per wavelength
Recalibration period 1 year
Environmental
Warm-up time 20 min
Operating temperature, humidity 25 ± 5°C non-condensing humidity
Storage temperature - 30 to + 60°C
Physical
Size (W x H x D) 4.06 x 13.26 x 37.03 cm (1.6 x 5.22 x 14.58 in)
Weight 1.2 kg (2.65 lb)
Approximately
Compliance
Safety and interface CE, CSA/UL/IEC61010-1, and LXI Class C requirements
MAP mORL-A1 modules installed in a MAP Series chassis
Multimode IL Meets IEC 61280-4-1 Encircled Flux requirements

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • IL, RL and length testing of optical connectors and cable assemblies
  • Testing structured-cabling solutions and optical splitters
  • Automated testing of multifiber assemblies such as MPO
  • Multimode fiber-based device testing
  • Verifying continuity and polarity of large multifiber assemblies
  • Measuring RL of line cards and receptacle-based transponders

Options & Accessories

Option Description
MSUP-BIDIUPG MAP-300 mORL Bi-di upgrade license — Requires high directivity mOSW 2x2
MSUP-300A-FIT MAP-300 fiber connector inspection app — Requires probe
MSUP-300A-PCTMAPPING MAP-300 PCT polarity and port mapping application add-on
MSUP-300A-PCTREMDB MAP-300 PCT remote centralized database connection key
MSUP-300A-SBSC MAP-300 PCT driver for legacy SB/SC series switches
MSUP-300A-PCT-TDR MAP-300 Enhanced PCT TDR License
MSUP-300A-PCTCASCADE MAP-300 PCT Switch Cascade
MSUP-300A-PCTLOGGING MAP-300 PCT Continuous Mode Logging License
MSUP-300A-SEIL MAP-300 Single Ended Insertion Loss license
MSUP-FIT MAP-200 Super Application Fiber Inspection (FIT)
MSUP-PCTMAPPING MAP-200 Super Application PCT Mapping
MSUP-PCTREMDB MAP-200 CT Remote Database Connection Key
MSUP-SBSC MAP-200 driver for legacy SB/SC series switches
MOSW-C111C004B0-MXXX-MYY Single 1 x 4 switch, bulkheads — XXX = fiber type code (M101 = 50 µm OM3), YY = connector type code (MFA = FC/APC)
MOSW-C111C008B0-MXXX-MYY Single 1 x 8 switch, bulkheads — XXX = fiber type code, YY = connector type code
MOSW-C111C012B0-MXXX-MYY Single 1 x 12 switch, bulkheads (Dual width module) — XXX = fiber type code, YY = connector type code
MOSW-C111C024B0-MXXX-MYY Single 1 x 24 switch, bulkheads (Dual width module) — XXX = fiber type code, YY = connector type code
MOPM-C1RH1 Single channel remote interface cassette
MOPM-C1RH2 Dual channel remote interface cassette
MOPM-C1RH4 Quad channel remote interface cassette
MOPM-C1RHPCT 2mm InGaAs PCT system remote head
MOPM-C1RHIP Integrated PCT system remote head
MOPM-C1RHPM Remote Head Polarity Mapper — Requires MAP-300 FW 13.0+ with PCT
AC500 FC/PC-FC/PC Universal Connector Adapter — Replacement mating sleeve
AC501 FC/PC-SC/PC Universal Connector Adapter — Replacement mating sleeve
AC502 FC/APC-FC/APC Universal Connector Adapter — Replacement mating sleeve
AC503 FC/APC-SC/APC Universal Connector Adapter — Replacement mating sleeve

Documents & Resources

Insertion Loss/Return Loss Testing (mORL)
datasheet · PDF
MAP-Based Insertion Loss/ Return Loss Testing Solution
datasheet · PDF
MAP Series PCT Enhanced TDR
datasheet · PDF
mOPM-C1RHPM Remote Head Polarity Mapper
datasheet · PDF
Multiple Application Platform
datasheet · PDF
Novel Insertion Loss Measurements VIAVI PCT Enhanced TDR
app note · PDF
Comparing Optical Return Loss (ORL) Measurement Methods
app note · PDF
New Passive Component/Connector Test (PCT) for the MAP-300
other
Introduction to Insertion Loss Measurements
app note · PDF
The Skeleton in Your Closet: EF Compliance Impact on Insertion Loss Testing
app note · PDF
Future Proofing Your IL/RL Testing
brochure · PDF
PCT System now available on MAP-300
other
How-To Videos: MAP-220 | PCT-rm
other
Low-Loss Requirements Drive Changes in Measurement Designs
app note · PDF
Measurement Integrity in IL/RL Testing
app note · PDF
MAP-202, MAP-204, MAP-220 Software
software
MAP-230, MAP-280 Software
software
Passive Component/Connector Test Solution
brochure · PDF
Inspection, Cleaning and Test Solutions for CS, SN, and MDC Fiber Connectors
brochure · PDF
Inspection, Cleaning and Test Solutions for MMC Connectors and TMT Ferrule Technology
brochure · PDF
MAP Series: Power Meter AC Detector Adaptors
brochure · PDF
Optical Manufacturing and Test Platform Catalog
brochure · PDF
VIAVI PCT Calibration
other · PDF
MAP-300 DUT Setup with PCTlite
other
High-Speed Fiber Array Unit (FAU) Testing with MAP-300
app note · PDF
Easy Environmental and Shock Testing of Optical Passive Components
brochure · PDF
FastIL: Revolutionizing Connectivity Testing
brochure · PDF
Testing, Inspection and Cleaning Solutions for Optical Connector Manufacturers
brochure · PDF
Universal Connector/Adapter System
brochure · PDF
FVAi-2030 Benchtop Microscope: Overview
other
Solutions Overview for Optical Connector Manufacturers
other