ONXF-730-PON-85-204-NTX

OneExpert HFC ONXF-730-PON-85-204-NTX DOCSIS 3.1 and PON Field Tester, 85/204 MHz, PON Selective Power Meter, NTX Package

OneExpert HFC ONX-730 new unit with an 85/204 MHz DOCSIS 3.1 module, a PON selective power meter, VFL and 10 Gbps Ethernet and WiFi 7 testing

Standard
IEEE 802.3 100M, 1G, 2.5G, 5G, and 10G Ethernet
Test Results
Ethernet Frames, IP Connectivity, Ping, Trace route, Web Connectivity, Speed Test up to 10 Gbps
Ethernet Testing Interfaces
10GBase-T RJ-45 Electrical – 100M, 1G, 2.5G, 5G, 10G
SFP+ Optical Ethernet
1G, 10G (SFP dependent)
Datasheet

Overview

The VIAVI OneExpert HFC ONXF-730-PON-85-204-NTX is a new-unit package of the OneExpert HFC ONX-730 handheld tester. It combines DOCSIS, Ethernet, PON and WiFi 7 service validation in one instrument and is used for service activation and troubleshooting at speeds up to 10 Gbps. The manufacturer states that throughput validation over these interfaces takes under a minute.

This package ships with the ONX-CATV-D31-S-8520-1212 DOCSIS 3.1 module (85/204 MHz), the ONX 730 NTX software package, a PON selective optical power meter, a visual fault locator and the optical loss mode. OneCheck Ethernet, OneCheck WiFi and 10G SpeedCheck are also included.

Optical testing

The selective power meter measures coexisting PON wavelengths separately through a dedicated SC/APC port. It can read the PON-ID to confirm that the technician is connected to the expected OLT. With the optional TruePON software, the unit automatically checks total optical loss, PON-ID, OLT connectivity and received power against the ODN class. A 650 nm visual fault locator and support for USB fiber scopes with automatic analysis help locate fiber faults.

DOCSIS and RF

The ONX-720/730 platform keeps the RF and DOCSIS test functions of the earlier ONX-620/630. These include downstream QAM and OFDM analysis, upstream ingress scanning, and forward and reverse sweep with the SCU-1800. Existing ONX DOCSIS/RF modules are supported.

Workflow and construction

VIAVI Test Process Automation provides one-button OneCheck workflows that give pass/fail results and save them with geo tags. The IP54-rated modular unit has integrated GPS and a field-replaceable 96 Wh battery. It supports StrataSync and the VIAVI Mobile Tech app, and its design allows upgrades to 25G/50G PON and DOCSIS 4.0.

Key Features

  • DOCSIS, Ethernet, PON and WiFi 7 throughput validation up to 10 Gbps in under a minute
  • ONX-CATV-D31-S-8520-1212 DOCSIS 3.1 module (85/204 MHz) included
  • PON Selective Optical Power Meter with dedicated SC/APC port
  • Visual Fault Locator (1 mW) included
  • Optical Loss mode (set/clear reference with delta) included
  • Broadband power capability for the selective PON hardware
  • ONX 730 NTX software package included
  • Return Signal Generator with loopback and Ingress Expert included
  • OneCheck Ethernet and OneCheck WiFi included
  • VIAVI SpeedCheck at 5 Gbps and 10 Gbps included
  • Unified OneCheck workflow with automated pass/fail and geo-tagged saved results
  • Reads the PON-ID to confirm connection to the expected OLT
  • TruePON automated PON network verification (optional)
  • OneCheck PON with GPON/XGS-PON emulation using a VIAVI SFP (optional)
  • USB fiber scope support with auto analysis and defect detection
  • Smart Access Anywhere remote coaching and training via PC or mobile (optional)
  • IP54-rated, drop-tested, modular design
  • Upgrade path to 25G/50G PON and DOCSIS 4.0
  • Integrated GPS, StrataSync and mobile app support
  • Field-replaceable 96 Wh battery for multi-day use

Specifications

Ethernet
Standard IEEE 802.3 100M, 1G, 2.5G, 5G, and 10G Ethernet
Test Results Ethernet Frames, IP Connectivity, Ping, Trace route, Web Connectivity, Speed Test up to 10 Gbps
Ethernet Testing Interfaces 10GBase-T RJ-45 Electrical – 100M, 1G, 2.5G, 5G, 10G
SFP+ Optical Ethernet 1G, 10G (SFP dependent)
Optional
SFP+ Electrical Ethernet 100M, 1G, 2.5G, 5G, 10G
Optional
WiFi
OneCheck WiFi (Connected Mode) WiFi - 7 2x2 (802.11 a/b/g/n/ac/ax/be) 2.4, 5, 6 GHz bands
Test Results Signal strength (RSSI), Standard, Width, Max Router PHY Rate, IP/Web connectivity, Throughput Tests (SpeedCheck, Ookla Speedtest, iPerf)
Throughput/Performance Tests
TCP Throughput Test VIAVI SpeedCheck: 5 Gbps, 10 Gbps; Ookla Speedtest: 5 Gbps, 10 Gbps; VIAVI TrueSpeed (RFC-6349): 5 Gbps, 10 Gbps
Ookla Speedtest and TrueSpeed are optional on this package
Performance Up to 10 Gbps for SpeedCheck, Ookla Speedtest, TrueSpeed, iPerf client: 5 Gbps, 10 Gbps
Test Results Delay, Upstream and Downstream Bit Rates
Bluetooth Communications
Communication Interface Bluetooth v5.0, BLE 2.0
Smart Device Support VIAVI Mobile Tech app, Android 8 or newer, iOS 12 or newer
Recommendation
Optical Fiber Scope Support
USB Optical Fiber Scope P5000i, FiberChek Probe
Results for Zone Defects Pass/Fail
Results for Zone Scratches Pass/Fail
Low Mag Field-of-View (FOV) Horizontal 740 μm, Vertical 550 μm
High Mag Field-of-View (FOV) Horizontal 370 μm, Vertical 275 μm
Particle Size Detection <1 μm
Power Source USB port
Selective PON Power Meter
Photo Diode InGaAs
Spectral Range Passband (1260…1500 nm, 1540…1650 nm)
Wavelength Setting 1342, 1358, 1490, 1577 nm; Dual: 1490/1577, 1342/1577, 1358/1577 nm; Broadband: 1270...1650 nm, Custom step size 1 nm
Broadband: in Broadband Mode (activated SW option required)
Resolution 0.01 dB, 0.001 µW
Measurement Range for Power Level -45…+3 dBm
Max. Power Level +15 dBm
Measurement Uncertainty 1490 nm: ±0.5 dB/±12 %; 1577 nm: ±0.5 dB/±12 %; 1342 nm: ±0.5 dB/±12 %; 1358 nm: ±0.5 dB/±12 %; Broadband: ±0.5 d/±5 %
Under reference conditions: -2 dBm (CW), nominal wavelength, 23 °C ±3 K, 45 to 75% relative humidity, SM test fiber (Single Mode, 9 µm core, 8° APC), when used with SC/APC connectors; Broadband in Broadband Mode (SW option required)
Measurement Range for PON-ID GPON: -30...0 dBm; XGS-PON: -25...0 dBm
Number of Calibrated Wavelengths 2 (1490, 1577 nm)
Tone Detection 270 Hz, 330 Hz, 1 kHz, 2 kHz
Future optional capability; in Broadband Mode (activated SW option required); with VIAVI Light Source and received optical power level > -50 dBm
Connection SC/APC
Visual Fault Locator (VFL)
Fiber Compatibility Single-mode, Multimode
Wavelength 650 nm (visible)
Output Modes Continuous and flashing
Connector Interface Universal 2.5 mm (fixed)
Controls On/Off Continuous/Flashing
Output Power 1 mW
Laser Safety Rating Class 2
Range (maximum) 7 km
VFL range depends on many factors, including fiber quality/loss
General
Size 5.0 x 11.1 x 4.25 in (W x L x H)
ONX-720 and ONX-730 with RF Module
Weight 3.15 kg (6.9 lb)
ONX-720 and ONX-730 with RF Module, without protective case
Operating Temperature Range Non-Charging: -10°C to 50°C; Battery Charging: 0°C to 40°C
Storage Temperature Range -20°C to 60°C
Operating Humidity Range 10% to 90% RH, non-condensing
For Indoor/Outdoor Use IP54 light rain (0.5 in/hr; 1.27 cm/hr)
Drop Rating 1 m (3.3 ft) onto concrete
Operating Altitude 4000 m max
Pollution 2°
RF immunity 8.5 V/m
For CATV measurements
DC Input Power 12 V@5 A
DC Charge Port 2.5 mm barrel
Battery 96 W/hr Li-Ion rechargeable battery, Field replaceable
Battery Charge Time 4 Hrs (90%) 6-8 Hrs 100% (AC charger)
Battery Life 3-5 day typical usage for installation technicians
10 installs a day
USB Host Port(s) USB-C, USB-A (USB 3.0)
DOCSIS/RF Frequency
Range 0.5 to 1,218 MHz
Accuracy ±10 ppm
Typical @25°C
Downstream Analysis — Port 1
Max Input Power 60 dBmV total integrated power
Operation on Powered TAP Operate with up to 90 VAC/DC on input port
Power Detection/Notification Notify of AC/DC power presence on port 1 above 2 Volts
Return Loss >9 dB
Auto Channel Plan Builder Auto detection of channels (analog, digital, QAM, OFDM)
Upstream Analysis — Port 2
Ingress Spectrum Scan 0.5–204 MHz, calibrated range 4-204 MHz
Sensitivity −45 dBmV
RBW 300 kHz
Min Detectable Level Upstream −55 dBmV
Dynamic Range 50 dB
Max Total Integrated Power 55 dBmV, 4–10 MHz, 60 dBmV, 10 to 204 MHz
Accuracy ±2 dB
Typical at 25°C
Sampling Rate Hyper Spectrum FFT Gapless technology - no missed samples, spans 0.5 to 110 MHz, 110 to 160 MHz, and 160 to 204 MHz
Return Loss >9.5 dB
Operation on Powered TAP Operate with up to 90 V AC/DC on input port
Analog Channel Measurement
Standards NTSC, PAL, SECAM
Min Detectable Signal −50 dBmV
Single channel
Level Accuracy ±1.5 dB from −20 dBmV to +50 dBmV typical at 25°C; ±2.0 dB, −20°C to +50°C
Downstream Digital Channel Analysis
Calibrated Power Levels -20 dBmV to +50 dBmV
Level Accuracy ±1.5 dB from −20 dBmV to +50 dBmV typical at 25°C; ±2.0 dB, −20°C to +50°C
Modulation(s) 64, 128, and 256 QAM, OFDM
Symbol Rates Annex A: 5.057 to 6.952 MSPS for 64, 128, and 256 QAM; Annex B: 5.057 MSPS for 64 QAM and 5.361 MSPS for 256 QAM; Annex C: 5.274 MSPS for 64 QAM, and 5.361 MSPS for 256 QAM
Regional demods DVB-C
OFDM Channels 24-192 MHz wide − up to 3 active OFDM channels
OFDM MER — max, min, average, standard deviation, percentile 16 to 44 dB
Profile Analysis Profiles A, B, C, D, NCP, and PLC (more profiles as implemented)
MER Specified range −5 to +20 dBmV: 21 to 40 dB, 64 QAM; 28 to 40 dB, 256 QAM; 16 to 44 dB, OFDM
MER range declines as input levels decrease. Expected MER range at MINLOCK level of –15 dBmV is >30 dB MER
MER Max Displayable Range 50 dB
MER Resolution 0.1 dB
MER Accuracy ±2 dB
Typical at 25°C
Minimum Lock Level −15 dBmV
BER — Channel Check and DOCSIS Check mode Down to 1E-9 (pre and post FEC)
BER — OneCheck Mode Down to 1E-8 (pre and post FEC) Std. 1E-9 user selectable
Interleaver Depth 128, 8 max
RF Module Inputs/Outputs
DOCSIS module ONX-CATV-D31-S-8520-1212 module (85/204 MHz D3.1)
85/204 MHz Upstream 1.2 GHz/1.2 GHz Downstream DOCSIS 3.1 Package
RF(2) F connectors replaceable
Port 1 Downstream 54/85/108/258MHz depending on diplexer
Port 2 Upstream 0.5–204 MHz and TDR
Diplexer 85 MHz upstream 4-85 MHz; downstream 108-1,218 MHz
Diplexer return path options may not be available on all units
Diplexer 204 MHz upstream 4-204 MHz: downstream 258-1,218 MHz
Diplexer return path options may not be available on all units
MoCA filter All models have MoCA triplexer to filter out MoCA signals below the highest downstream frequency
Sweep
Forward Sweep Telemetry Frequency Diplexer dependent 50-1,218 MHz
Input port: Port 1
Forward Sweep Compatibility SCU-1800
Reverse Sweep Output Transmit Port Port 1 or Port 2 (user selectable)
Port 1 Sweep Frequency Range Diplexer dependent 5-42/5-65/5-85/5-204 MHz
Port 2 Sweep Frequency Range 5-204 MHz
Reverse Sweep Compatibility SCU-1800 or DAA/RPHY via XperTRAK
Package Feature Matrix
PON Selective Optical Power Meter Standard
TruePON PON-ID Analysis with OLT-ID and Loss Optional
Broadband Power Capability for Selective PON Hardware Standard
Optical Loss Mode (Set/clear Ref with Delta) Standard
Visual Fault Locator (1 mW) Standard
OneCheck WiFi7, OneCheck Ethernet, VIAVI SpeedCheck – 5 Gbps / 10 Gbps Standard
Optical Ethernet over SFP+, OneCheck PON w/Emulation, Ookla Speedtest, TrueSpeed, iPerf, Smart Access Anywhere Optional
Return Signal Generator w/Loopback Standard
Ingress Expert Standard
HomeTDR, Home Leakage Test, Reverse Sweepless Sweep, QAM Video MPEG Verification, Field View w/RSG Optional

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • Residential and small business service activation
  • Multi-gig DOCSIS service turn-up and troubleshooting
  • PON/FTTH service validation
  • XGS-PON and GPON OLT link verification
  • Ethernet throughput testing to 10 Gbps
  • WiFi 7 in-home service delivery verification
  • HFC upstream ingress troubleshooting
  • HFC forward and reverse sweep

Included

  • PON Selective Optical Power Meter
  • VFL
  • Optical Loss
  • OneCheck Ethernet
  • OneCheck WiFi
  • 10G SpeedCheck
  • ONX-CATV-D31-S-8520-1212 module (85/204 MHz D3.1)
  • ONX 730 NTX Package
  • Protective Fitted Case
  • Cat6A jumper M-F and M-M

Options & Accessories

Option Description
ONXF-SW-TRUEPON TruePON software option — Requires PON selective HW
ONXF-SW-SFP-ETH Enable SFP+ port for Optical Ethernet testing over VIAVI supported SFP's
ONXF-SW-OC-PON OneCheck PON – PON testing via GPON/XGSPON SFP+
ONXF-SW-OC-GPON-EMUL GPON Emulation for live service testing on GPON network
ONXF-SW-OC-XGSPON-EMUL GPON Emulation for live service testing on GPON network — Description as printed in the datasheet; the code indicates XGS-PON emulation
ONX-SMART-ACCESS Smart Access Anywhere
ONXF-SW-OOKLA-SPD-5G-1Y ONX Ookla Speedtest to 5 Gbps 1 Yr Timed License/deployed via StrataSync
ONXF-SW-OOKLA-SPD-5G-3Y ONX Ookla Speedtest to 5 Gbps 3 Yr Timed License/deployed via StrataSync
ONXF-SW-OOKLA-SPD-5G-5Y ONX Ookla Speedtest to 5 Gbps 5 Yr Timed License/deployed via StrataSync
ONXF-SW-OOKLA-SPD-5G ONX Ookla Speedtest to 5 Gbps
ONXF-SW-OOKLA-SPD-10G-1Y ONX Ookla Speedtest to 10 Gbps 1 Yr Timed License/deployed via StrataSync
ONXF-SW-OOKLA-SPD-10G-3Y ONX Ookla Speedtest to 10 Gbps 3 Yr Timed License/deployed via StrataSync
ONXF-SW-OOKLA-SPD-10G-5Y ONX Ookla Speedtest to 10 Gbps 5 Yr Timed License/deployed via StrataSync
ONXF-SW-OOKLA-SPD-10G ONX Ookla Speedtest to 10 Gbps
ONXF-SW-TRUESPEED-5G-1Y ONX TrueSpeed to 5 Gbps 1 Yr Timed License/deployed via StrataSync
ONXF-SW-TRUESPEED-5G-3Y ONX TrueSpeed to 5 Gbps 3 Yr Timed License/deployed via StrataSync
ONXF-SW-TRUESPEED-5G ONX TrueSpeed to 5 Gbps permanent License
ONXF-SW-TRUESPEED-10G-1Y ONX TrueSpeed to 10 Gbps 1 Yr Timed License/deployed via StrataSync
ONXF-SW-TRUESPEED-10G-3Y ONX TrueSpeed to 10 Gbps 3 Yr Timed License/deployed via StrataSync
ONXF-SW-TRUESPEED-10G ONX TrueSpeed to 10 Gbps Permanent License
ONXF-SW-IPERF-5G-1Y ONX iPerf test to 5 Gbps 1 Yr Timed License/deployed via StrataSync
ONXF-SW-IPERF-5G-3Y ONX iPerf test to 5 Gbps 3 Yr Timed License/deployed via StrataSync
ONXF-SW-IPERF-5G ONX iPerf test to 5 Gbps Permanent License
ONXF-SW-IPERF-10G-1Y ONX iPerf test to 10 Gbps 1 Yr Timed License/deployed via StrataSync
ONXF-SW-IPERF-10G-3Y ONX iPerf test to 10 Gbps 3 Yr Timed License/deployed via StrataSync
ONXF-SW-IPERF-10G ONX iPerf test to 10 Gbps permanent License
ONX-CATV-SW-HL-LKG Home Leakage Software Option
ONX-CATV-SW-HOMETDR Home TDR Software Option
ONX-CATV-SW-REVSWPLSSWP Reverse Sweepless Sweep Option for ONX 730's
ONX-CATV-SW-QAM-VIDEO QAM Video MPEG Verification Option
ONX-CATV-SW-RP-SNR-OCE Return Path SNR in OneCheck Expert - OneExpert CATV
ONX-CATV-SW-FV-RSG PathTrak Fieldview with Return Signal Generator for ONX 730s
ONX-CATV-FWD-SWEEP Active Forward Sweep
ONX-CATV-REV-SWEEP Active Reverse Sweep
NSC-SFP-GPON GPON SFP for GPON emulation
NSC-SFP-XGSPON XGSPON SFP+ for XGSPON emulation
NSC-SFP-850-1G-10G Optical Ethernet SFP + 850 nm SR 1G and 10G
NSC-SFP-1310-1G-10G Optical Ethernet SFP + 1310 nm LR 1G and 10G
NSC-SFP-1550-1G-10G Optical Ethernet SFP + 1550 nm ER 1G and 10G
AC-CHARGER Replacement AC charger (no power cord)
AC-CAR-CHARGER Car Charger
CC-034601 Large Carrying Case
1019-00-1366 Strand Hook
ONXF-HANDSTRAP Handstrap for use on unit without a case
ONXF-HFC-BATT-96WHR Replacement 96 W/Hr Battery
ONXF-DISPLAY-PROTECTOR-5P Replacement screen protector (5 pack)
ONXF-ETH-ADAPT-M-F Ethernet Cat6a M-F adapter 0.5 m
NSC-ETHERNET-CABLE Ethernet Cat6a M-M Patch Cable
ONXF-HFC-CASE Fitted protective case for ONX-720/730 with DOCSIS 3.1