VIAVI SCU-1800 Sweep Control Unit 1RU rack-mount front panel
SCU-1800

VIAVI SCU-1800 Sweep Control Unit for Headend/Hub CATV Forward and Return Sweep

1RU headend/hub sweep control unit with forward sweep to 1,218 MHz and return sweep to 204 MHz on up to 16 ports.

Output Transmit Port 1
1 F-Type Connector
Output port impedance
75 Ω
Input ports
16 (F-type connector) with activity indicator
Input port impedance
75 Ω
Datasheet

Overview

The VIAVI SCU-1800 is a 1RU rack-mounted Sweep Control Unit for cable headend and hub sites. It works with the OneExpert CATV ONX-630 field meter and provides non-interfering downstream sweep to 1.218 GHz and upstream sweep to 204 MHz on up to 16 ports, supporting DOCSIS 3.1 network frequency plans.

The ONX/SCU system is compatible with existing VIAVI sweep equipment, including SDA-55xx rack-mounted sweep gear and DSAM meters, so operators can introduce it alongside their current field instruments and move to the newer platform gradually.

With 16 switchable return sweep ports in one rack unit, less return-path combining is needed, which improves noise performance and lets several sweep receivers be consolidated into one unit. A single SCU-1800 needs only one telemetry signal, where several SDA units each needed their own, so less spectrum goes to telemetry.

The unit can be configured remotely or locally, and its interface is reached through a web browser over Ethernet, the internet or an intranet. Improved pulse generation gives a clean RF sweep signal with narrow pulses that can be placed between carriers.

Key Features

  • DOCSIS 3.1 frequency range – 1,218 MHz forward, 204 MHz reverse
  • 1 RU and up to 16 switchable return sweep ports per unit
  • Configuration interface is accessible via Ethernet/Internet/Intranet and browser
  • Remotely and locally configurable
  • Compatible with existing VIAVI sweep equipment (SDA-55xx, DSAM)
  • Up to 500 sweep points in a user-defined sweep plan
  • Narrow sweep pulses enabling insertion between carriers
  • Single telemetry signal replaces separate telemetry for multiple SDAs

Specifications

Ports
Output Transmit Port 1 1 F-Type Connector
Output port impedance 75 Ω
Input ports 16 (F-type connector) with activity indicator
Input port impedance 75 Ω
Port-to-port isolation >65 dB
Telemetry
Frequency Range 42 to 1,218 MHz
Frequency Resolution 10 kHz
Modulation ±100 kHz deviation; 65 kbps
Output Level +20 to +50 dBmV, 1 dB resolution, 0.5 dB accuracy typical, 1 dB accuracy over temp
Spectral Purity 50 dBc harmonics and spurious
Recommend 1 MHz space from SC QAM edge
Forward Sweep
Outputs 1 Transmit port
Sweep points Up to 500 sweep points
User defined sweep plan can utilize injected sweep pulses and/or field instrument reference of active carriers
Supported sweep plan active carrier types Analog (NTSC, PALB, PAL GH, PAL I, PAL DK), Digital (6 or 8MHz), OFDM (24-192MHz)
For reference and measurement by the field instrument
Compatibility ONX-630, DSAM-6300 and SDA-5000 in SDA Sweep Mode
Compatibility range, ONX-630
ONX-630
model/diplexer dependent 50-1218MHz
Compatibility range, DSAM-6300
DSAM-6300
50-1000MHz
Compatibility range, SDA-5000
SDA-5000
42-1000MHz
Sweep Pulse
Frequency Range 42 to 1,218 MHz
Bandwidth <5 kHz @ 3dB BW; <50 kHz @ 50 dB BW
Frequency Resolution 10 kHz
Level +20 to +50 dBmV, 1 dB resolution, 0.5 dB accuracy typical, 1 dB accuracy over temp
Spectral Purity 50 dBc harmonics and spurious
Recommend 1 MHz space from SC QAM edge
Reverse Sweep
Inputs 16 isolated inputs. Port 1 is standard on all units. Ports 2-16 are optionally enabled and are Auto-Scan for all 16 ports.
Frequency Range 5 to 204 MHz
Compatibility Compatible with ONX-630 and DSAM-6300
ONX-630 single port mode
ONX-630
Diplex dependent 4-42, 4-65, 4-85, 4-204 MHz
ONX-630 dual port sweep
ONX-630
Port 2, 4-204 MHz
DSAM-6300
DSAM-6300
Model/Diplexer limited, 4-42 MHz, 4-65 MHz, 4-85 MHz
Recommended input level 0 dBmV
Input range and accuracy ± 20 dBmV allowable input range; ± 0.75 dB typical; ± 2 dB over temp
Minimum Signal-to-Noise Ratio 20 dB
Signal-to-noise ratio required on received reverse telemetry from field meters
General
Enclosure 19-inch (48.3 cm) 1-RU rack mount
Width 19 Inches (48.3 cm)
Depth 14.6 Inches (37.1 cm)
Height 1 RU, 1.74 Inches (4.4 cm)
Weight 7.85 pounds (3.56 kg)
Power Dual –48 V DC (–46 to 50 V DC)
AC adapter included
Display 2x16 character backlit
Ethernet 10/100 Mbps
USB 1 USB 2.0
Data storage 1 GB flash memory
Environmental
Use For indoor use
Operating temperature 5 to 45°C
Storage temperature −20 to 60°C
Drop and Vibration Bench Handling - MIL-STD-810F
Humidity 10 – 90% RH non-condensing
RF immunity 8.5 V/m
Maximum altitude 4000 m (13,123 ft)
Pollution 2°

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • Headend and hub forward path sweep
  • Return path sweep up to 204 MHz
  • DOCSIS 3.1 HFC network maintenance
  • Consolidation of rack-mounted sweep receivers
  • Migration from SDA-5500/SDA-5510 sweep systems

Included

  • AC adapter

Options & Accessories

Option Description
SCU-1800-FWD-REV-1P SCU-1800, 1.218 GHz Forward and Single User 204 MHz Reverse, 1 Active Reverse port — FWD & REV package
SCU-1800-FWD-REV-16P SCU-1800, 1.218 GHz Forward and Single User 204 MHz Reverse, 16 Active Reverse ports — FWD & REV package
SCU-1800-REV-MU-1P SCU-1800, 204 MHz Reverse, Multi-User, 1 port — Reverse Only package
SCU-1800-REV-MU-16P SCU-1800, 204 MHz Reverse, Multi-User, 16 port — Reverse Only package

Documents & Resources