VIAVI SCU-1800 Sweep Control Unit for Headend/Hub CATV Forward and Return Sweep
1RU headend/hub sweep control unit with forward sweep to 1,218 MHz and return sweep to 204 MHz on up to 16 ports.
- Output Transmit Port 1
- 1 F-Type Connector
- Output port impedance
- 75 Ω
- Input ports
- 16 (F-type connector) with activity indicator
- Input port impedance
- 75 Ω
Overview
The VIAVI SCU-1800 is a 1RU rack-mounted Sweep Control Unit for cable headend and hub sites. It works with the OneExpert CATV ONX-630 field meter and provides non-interfering downstream sweep to 1.218 GHz and upstream sweep to 204 MHz on up to 16 ports, supporting DOCSIS 3.1 network frequency plans.
The ONX/SCU system is compatible with existing VIAVI sweep equipment, including SDA-55xx rack-mounted sweep gear and DSAM meters, so operators can introduce it alongside their current field instruments and move to the newer platform gradually.
With 16 switchable return sweep ports in one rack unit, less return-path combining is needed, which improves noise performance and lets several sweep receivers be consolidated into one unit. A single SCU-1800 needs only one telemetry signal, where several SDA units each needed their own, so less spectrum goes to telemetry.
The unit can be configured remotely or locally, and its interface is reached through a web browser over Ethernet, the internet or an intranet. Improved pulse generation gives a clean RF sweep signal with narrow pulses that can be placed between carriers.
Key Features
- DOCSIS 3.1 frequency range – 1,218 MHz forward, 204 MHz reverse
- 1 RU and up to 16 switchable return sweep ports per unit
- Configuration interface is accessible via Ethernet/Internet/Intranet and browser
- Remotely and locally configurable
- Compatible with existing VIAVI sweep equipment (SDA-55xx, DSAM)
- Up to 500 sweep points in a user-defined sweep plan
- Narrow sweep pulses enabling insertion between carriers
- Single telemetry signal replaces separate telemetry for multiple SDAs
Specifications
| Output Transmit Port 1 | 1 F-Type Connector |
|---|---|
| Output port impedance | 75 Ω |
| Input ports | 16 (F-type connector) with activity indicator |
| Input port impedance | 75 Ω |
| Port-to-port isolation | >65 dB |
| Frequency Range | 42 to 1,218 MHz |
|---|---|
| Frequency Resolution | 10 kHz |
| Modulation | ±100 kHz deviation; 65 kbps |
| Output Level | +20 to +50 dBmV, 1 dB resolution, 0.5 dB accuracy typical, 1 dB accuracy over temp |
| Spectral Purity |
50 dBc harmonics and spurious
Recommend 1 MHz space from SC QAM edge
|
| Outputs | 1 Transmit port |
|---|---|
| Sweep points |
Up to 500 sweep points
User defined sweep plan can utilize injected sweep pulses and/or field instrument reference of active carriers
|
| Supported sweep plan active carrier types |
Analog (NTSC, PALB, PAL GH, PAL I, PAL DK), Digital (6 or 8MHz), OFDM (24-192MHz)
For reference and measurement by the field instrument
|
| Compatibility | ONX-630, DSAM-6300 and SDA-5000 in SDA Sweep Mode |
|
Compatibility range, ONX-630
ONX-630
|
model/diplexer dependent 50-1218MHz |
|
Compatibility range, DSAM-6300
DSAM-6300
|
50-1000MHz |
|
Compatibility range, SDA-5000
SDA-5000
|
42-1000MHz |
| Frequency Range | 42 to 1,218 MHz |
|---|---|
| Bandwidth | <5 kHz @ 3dB BW; <50 kHz @ 50 dB BW |
| Frequency Resolution | 10 kHz |
| Level | +20 to +50 dBmV, 1 dB resolution, 0.5 dB accuracy typical, 1 dB accuracy over temp |
| Spectral Purity |
50 dBc harmonics and spurious
Recommend 1 MHz space from SC QAM edge
|
| Inputs | 16 isolated inputs. Port 1 is standard on all units. Ports 2-16 are optionally enabled and are Auto-Scan for all 16 ports. |
|---|---|
| Frequency Range | 5 to 204 MHz |
| Compatibility | Compatible with ONX-630 and DSAM-6300 |
|
ONX-630 single port mode
ONX-630
|
Diplex dependent 4-42, 4-65, 4-85, 4-204 MHz |
|
ONX-630 dual port sweep
ONX-630
|
Port 2, 4-204 MHz |
|
DSAM-6300
DSAM-6300
|
Model/Diplexer limited, 4-42 MHz, 4-65 MHz, 4-85 MHz |
| Recommended input level | 0 dBmV |
| Input range and accuracy | ± 20 dBmV allowable input range; ± 0.75 dB typical; ± 2 dB over temp |
| Minimum Signal-to-Noise Ratio |
20 dB
Signal-to-noise ratio required on received reverse telemetry from field meters
|
| Enclosure | 19-inch (48.3 cm) 1-RU rack mount |
|---|---|
| Width | 19 Inches (48.3 cm) |
| Depth | 14.6 Inches (37.1 cm) |
| Height | 1 RU, 1.74 Inches (4.4 cm) |
| Weight | 7.85 pounds (3.56 kg) |
| Power |
Dual –48 V DC (–46 to 50 V DC)
AC adapter included
|
| Display | 2x16 character backlit |
| Ethernet | 10/100 Mbps |
| USB | 1 USB 2.0 |
| Data storage | 1 GB flash memory |
| Use | For indoor use |
|---|---|
| Operating temperature | 5 to 45°C |
| Storage temperature | −20 to 60°C |
| Drop and Vibration | Bench Handling - MIL-STD-810F |
| Humidity | 10 – 90% RH non-condensing |
| RF immunity | 8.5 V/m |
| Maximum altitude | 4000 m (13,123 ft) |
| Pollution | 2° |
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- Headend and hub forward path sweep
- Return path sweep up to 204 MHz
- DOCSIS 3.1 HFC network maintenance
- Consolidation of rack-mounted sweep receivers
- Migration from SDA-5500/SDA-5510 sweep systems
Included
- AC adapter
Options & Accessories
| Option | Description |
|---|---|
| SCU-1800-FWD-REV-1P | SCU-1800, 1.218 GHz Forward and Single User 204 MHz Reverse, 1 Active Reverse port — FWD & REV package |
| SCU-1800-FWD-REV-16P | SCU-1800, 1.218 GHz Forward and Single User 204 MHz Reverse, 16 Active Reverse ports — FWD & REV package |
| SCU-1800-REV-MU-1P | SCU-1800, 204 MHz Reverse, Multi-User, 1 port — Reverse Only package |
| SCU-1800-REV-MU-16P | SCU-1800, 204 MHz Reverse, Multi-User, 16 port — Reverse Only package |