OneExpert HFC ONXF-720-PON-42-85-TSX DOCSIS 3.1 and PON Field Tester with 42/85 MHz Module and TSX Package
OneExpert HFC ONX-720 package with a PON selective power meter, VFL, 42/85 MHz DOCSIS 3.1 module and TSX software for 10 Gbps service testing.
- Package contents
- PON Selective Optical Power Meter, VFL, OneCheck Ethernet, OneCheck WiFi, 10G SpeedCheck, ONX-CATV-D31-S-4285-1012 module (42/85 MHz D3.1), ONX 720 TSX Package, Protective Fitted Case, Cat6A jumper M-F and M-M
- DOCSIS configuration
- 42/85 MHz Upstream 1.0 GHz/1.2 GHz Downstream DOCSIS 3.1
- TruePON PON-ID Analysis with OLT-ID and Loss
- Optional
- Broadband Power Capability for Selective PON Hardware
- Included
Overview
The VIAVI OneExpert HFC ONXF-720-PON-42-85-TSX is a new-unit ordering package of the OneExpert HFC ONX-720. The ONX-720/730 platform validates DOCSIS, Ethernet, PON and WiFi 7 throughput up to 10 Gbps in under a minute. It is built for installation and service technicians testing residential and small business services.
This package combines the ONX-720 mainframe with a PON Selective Optical Power Meter, a Visual Fault Locator, OneCheck Ethernet, OneCheck WiFi and 10G SpeedCheck. It also includes the ONX-CATV-D31-S-4285-1012 DOCSIS 3.1 module (42/85 MHz upstream, 1.0 GHz/1.2 GHz downstream), the ONX 720 TSX software package, a protective fitted case and Cat6A M-F and M-M jumpers.
Optical testing
The selective power meter measures coexistent PON wavelengths separately and reads the PON-ID to confirm connection to the expected OLT. With the optional TruePON software, the unit automatically checks Total Optical Loss, PON-ID, OLT connectivity and received power against the ODN class. A 1 mW VFL and support for USB fiber scopes with automatic pass/fail analysis help locate faults in the fiber.
DOCSIS and RF
The ONX-720/730 carries over the RF and DOCSIS testing features of the ONX-620/630 and supports the existing RF modules. Test Process Automation provides one-button OneCheck workflows that save geo-tagged results. The IP54-rated modular design has an upgrade path to 25G/50G PON and DOCSIS 4.0, along with integrated GPS, StrataSync and mobile app support.
Key Features
- PON Selective Optical Power Meter with SC/APC connection
- Visual Fault Locator (1 mW)
- ONX-CATV-D31-S-4285-1012 DOCSIS 3.1 module (42/85 MHz)
- ONX 720 TSX software package
- OneCheck Ethernet and OneCheck WiFi 7 automated pass/fail testing
- VIAVI SpeedCheck to 5 Gbps and 10 Gbps
- Broadband power capability for the selective PON hardware
- Optional TruePON PON-ID analysis with OLT-ID and loss
- Optional OneCheck PON with GPON/XGS-PON emulation using VIAVI SFP
- 10GBase-T RJ-45 electrical Ethernet test port
- USB fiber scope support with Auto Analysis
- IP54 rated, drop-tested to 1 m onto concrete
- Field-replaceable 96 W/hr Li-Ion battery
- Integrated GPS, StrataSync and VIAVI Mobile Tech app support
- Modular upgrade path to 25G/50G PON and DOCSIS 4.0
Specifications
| Package contents | PON Selective Optical Power Meter, VFL, OneCheck Ethernet, OneCheck WiFi, 10G SpeedCheck, ONX-CATV-D31-S-4285-1012 module (42/85 MHz D3.1), ONX 720 TSX Package, Protective Fitted Case, Cat6A jumper M-F and M-M |
|---|---|
| DOCSIS configuration |
42/85 MHz Upstream 1.0 GHz/1.2 GHz Downstream DOCSIS 3.1
The module compatibility table on page 7 describes ONX-CATV-D31-S-4285-1012 as '45/85 MHz 1.0/1.2 GHz'
|
| TruePON PON-ID Analysis with OLT-ID and Loss | Optional |
| Broadband Power Capability for Selective PON Hardware | Included |
| Return Signal Generator w/Loopback | Optional |
| Ingress Expert | Optional |
| HomeTDR / Home Leakage Test | Optional |
| Standard | IEEE 802.3 100M, 1G, 2.5G, 5G, and 10G Ethernet |
|---|---|
| Test Results | Ethernet Frames, IP Connectivity, Ping, Trace route, Web Connectivity, Speed Test up to 10 Gbps |
| 10GBase-T RJ-45 Electrical | 100M, 1G, 2.5G, 5G, 10G |
| SFP+ Optical Ethernet |
1G, 10G (SFP dependent)
Optional
|
| SFP+ Electrical Ethernet |
100M, 1G, 2.5G, 5G, 10G
Optional
|
| OneCheck WiFi (Connected Mode) | WiFi - 7 2x2 (802.11 a/b/g/n/ac/ax/be) 2.4, 5, 6 GHz bands |
|---|---|
| Test Results | Signal strength (RSSI), Standard, Width, Max Router PHY Rate, IP/Web connectivity, Throughput Tests (SpeedCheck, Ookla Speedtest, iPerf) |
| TCP Throughput Test |
VIAVI SpeedCheck: 5 Gbps, 10 Gbps; Ookla Speedtest: 5 Gbps, 10 Gbps; VIAVI TrueSpeed (RFC-6349): 5 Gbps, 10 Gbps
Ookla Speedtest and TrueSpeed are options
|
|---|---|
| Performance | Up to 10 Gbps for SpeedCheck, Ookla Speedtest, TrueSpeed, iPerf client: 5 Gbps, 10 Gbps |
| Test Results | Delay, Upstream and Downstream Bit Rates |
| Communication Interface | Bluetooth v5.0, BLE 2.0 |
|---|---|
| Smart Device Support |
VIAVI Mobile Tech app, Android 8 or newer, iOS 12 or newer
Recommendation
|
| USB Optical Fiber Scope | P5000i, FiberChek Probe |
|---|---|
| Results for Zone Defects / Scratches | Pass/Fail |
| Low Mag Field-of-View (FOV) | Horizontal 740 μm, Vertical 550 μm |
| High Mag Field-of-View (FOV) | Horizontal 370 μm, Vertical 275 μm |
| Particle Size Detection | <1 μm |
| Power Source | USB port |
| Photo Diode | InGaAs |
|---|---|
| Spectral Range | Passband (1260…1500 nm, 1540…1650 nm) |
| Wavelength Setting |
1342, 1358, 1490, 1577 nm; Dual: 1490/1577, 1342/1577, 1358/1577 nm; Broadband: 1270...1650 nm, Custom step size 1 nm
Broadband in Broadband Mode (activated SW option required)
|
| Resolution | 0.01 dB, 0.001 µW |
| Measurement Range for Power Level | -45…+3 dBm |
| Max. Power Level | +15 dBm |
| Measurement Uncertainty |
1490 nm: ±0.5 dB/±12 %; 1577 nm: ±0.5 dB/±12 %; 1342 nm: ±0.5 dB/±12 %; 1358 nm: ±0.5 dB/±12 %; Broadband: ±0.5 d/±5 %
Under reference conditions: -2 dBm (CW), nominal wavelength, 23 °C ±3 K, 45 to 75% relative humidity, SM test fiber (9 µm core, 8° APC), SC/APC connectors
|
| Measurement Range for PON-ID | GPON: -30...0 dBm; XGS-PON: -25...0 dBm |
| Number of Calibrated Wavelengths | 2 (1490, 1577 nm) |
| Tone Detection |
270 Hz, 330 Hz, 1 kHz, 2 kHz
Future optional capability; in Broadband Mode (activated SW option required)
|
| Connection | SC/APC |
| Fiber Compatibility | Single-mode, Multimode |
|---|---|
| Wavelength | 650 nm (visible) |
| Output Modes | Continuous and flashing |
| Connector Interface | Universal 2.5 mm (fixed) |
| Output Power | 1 mW |
| Laser Safety Rating | Class 2 |
| Range (maximum) |
7 km
VFL range depends on many factors, including fiber quality/loss
|
| Size |
5.0 x 11.1 x 4.25 in (W x L x H)
ONX-720 and ONX-730 with RF Module
|
|---|---|
| Weight |
3.15 kg (6.9 lb)
Without protective case; ONX-720 and ONX-730 with RF Module
|
| Operating Temperature Range | Non-Charging: -10°C to 50°C; Battery Charging: 0°C to 40°C |
| Storage Temperature Range | -20°C to 60°C |
| Operating Humidity Range | 10% to 90% RH, non-condensing |
| For Indoor/Outdoor Use | IP54 light rain (0.5 in/hr; 1.27 cm/hr) |
| Drop Rating | 1 m (3.3 ft) onto concrete |
| Operating Altitude | 4000 m max |
| RF immunity |
8.5 V/m
For CATV measurements
|
| DC Input Power | 12 V@5 A |
| DC Charge Port | 2.5 mm barrel |
| Battery | 96 W/hr Li-Ion rechargeable battery, Field replaceable |
| Battery Charge Time | 4 Hrs (90%) 6-8 Hrs 100% (AC charger) |
| Battery Life |
3-5 day typical usage for installation technicians
10 installs a day
|
| USB Host Port(s) | USB-C, USB-A (USB 3.0) |
| Frequency Range | 0.5 to 1,218 MHz |
|---|---|
| Frequency Accuracy |
±10 ppm
Typical @25°C
|
| Max Input Power | 60 dBmV total integrated power |
| Operation on Powered TAP | Operate with up to 90 VAC/DC on input port |
| Return Loss | >9 dB |
| Auto Channel Plan Builder | Auto detection of channels (analog, digital, QAM, OFDM) |
| Diplexer (42 MHz) |
upstream 4-42 MHz; downstream 54–1,004 MHz
Diplexer return path options may not be available on all units
|
| Diplexer (85 MHz) |
upstream 4-85 MHz; downstream 108-1,218 MHz
Diplexer return path options may not be available on all units
|
| MoCA filter | All models have MoCA triplexer to filter out MoCA signals below the highest downstream frequency |
| Ingress Spectrum Scan | 0.5–204 MHz, calibrated range 4-204 MHz |
|---|---|
| Sensitivity | −45 dBmV |
| RBW | 300 kHz |
| Min Detectable Level Upstream | −55 dBmV |
| Dynamic Range | 50 dB |
| Max Total Integrated Power | 55 dBmV, 4–10 MHz, 60 dBmV, 10 to 204 MHz |
| Accuracy |
±2 dB
Typical at 25°C
|
| Sampling Rate | Hyper Spectrum FFT Gapless technology - no missed samples, spans 0.5 to 110 MHz, 110 to 160 MHz, and 160 to 204 MHz |
| Return Loss | >9.5 dB |
| Calibrated Power Levels | -20 dBmV to +50 dBmV |
|---|---|
| Level Accuracy | ±1.5 dB from −20 dBmV to +50 dBmV typical at 25°C; ±2.0 dB, −20°C to +50°C |
| Modulation(s) | 64, 128, and 256 QAM, OFDM |
| OFDM Channels | 24-192 MHz wide − up to 3 active OFDM channels |
| Profile Analysis | Profiles A, B, C, D, NCP, and PLC (more profiles as implemented) |
| MER Specified range |
21 to 40 dB, 64 QAM; 28 to 40 dB, 256 QAM; 16 to 44 dB, OFDM
At −5 to +20 dBmV; MER range declines as input levels decrease
|
| Minimum Lock Level | −15 dBmV |
| BER — Channel Check and DOCSIS Check mode | Down to 1E-9 (pre and post FEC) |
| Forward Sweep Telemetry Frequency | Diplexer dependent 50-1,218 MHz |
|---|---|
| Forward Sweep Compatibility | SCU-1800 |
| Reverse Sweep Port 1 Frequency Range | Diplexer dependent 5-42/5-65/5-85/5-204 MHz |
| Reverse Sweep Port 2 Frequency Range | 5-204 MHz |
| Reverse Sweep Compatibility | SCU-1800 or DAA/RPHY via XperTRAK |
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- DOCSIS service activation and troubleshooting
- PON service turn-up (GPON, XGS-PON)
- Multi-gig Ethernet throughput validation
- WiFi 7 service delivery testing
- Residential and small business installations
- Upstream ingress troubleshooting
Included
- ONX-CATV-D31-S-4285-1012 module (42/85 MHz D3.1)
- ONX 720 TSX Package
- Protective Fitted Case
- Cat6A jumper M-F and M-M
Options & Accessories
| Option | Description |
|---|---|
| ONXF-SW-TRUEPON | TruePON software option — Requires PON selective HW |
| ONXF-SW-SFP-ETH | Enable SFP+ port for Optical Ethernet testing over VIAVI supported SFP's |
| ONXF-SW-OC-PON | OneCheck PON – PON testing via GPON/XGSPON SFP+ |
| ONXF-SW-OC-GPON-EMUL | GPON Emulation for live service testing on GPON network |
| ONXF-SW-OC-XGSPON-EMUL | XGS-PON emulation for live service testing — Datasheet lists the description as 'GPON Emulation for live service testing on GPON network' |
| ONX-SMART-ACCESS | Smart Access Anywhere |
| ONXF-SW-OOKLA-SPD-10G | ONX Ookla Speedtest to 10 Gbps |
| ONXF-SW-OOKLA-SPD-5G | ONX Ookla Speedtest to 5 Gbps |
| ONXF-SW-TRUESPEED-10G | ONX TrueSpeed to 10 Gbps Permanent License |
| ONXF-SW-TRUESPEED-5G | ONX TrueSpeed to 5 Gbps permanent License |
| ONXF-SW-IPERF-10G | ONX iPerf test to 10 Gbps permanent License |
| ONXF-SW-IPERF-5G | ONX iPerf test to 5 Gbps Permanent License |
| ONX-CATV-SW-HL-LKG | Home Leakage Software Option |
| ONX-CATV-SW-HOMETDR | Home TDR Software Option |
| ONX-CATV-SW-RSG-LOOP | Return Signal Generator with Loopback Option |
| ONX-CATV-SW-INGRESS-EXP | Ingress Expert Option for ONX 720's |
| ONX-CATV-FWD-SWEEP | Active Forward Sweep |
| ONX-CATV-REV-SWEEP | Active Reverse Sweep |
| NSC-SFP-GPON | GPON SFP for GPON emulation |
| NSC-SFP-XGSPON | XGSPON SFP+ for XGSPON emulation |
| NSC-SFP-850-1G-10G | Optical Ethernet SFP + 850 nm SR 1G and 10G |
| NSC-SFP-1310-1G-10G | Optical Ethernet SFP + 1310 nm LR 1G and 10G |
| NSC-SFP-1550-1G-10G | Optical Ethernet SFP + 1550 nm ER 1G and 10G |
| AC-CHARGER | Replacement AC charger (no power cord) |
| AC-CAR-CHARGER | Car Charger |
| CC-034601 | Large Carrying Case |
| 1019-00-1366 | Strand Hook |
| ONXF-HANDSTRAP | Handstrap for use on unit without a case |
| ONXF-HFC-BATT-96WHR | Replacement 96 W/Hr Battery |
| ONXF-DISPLAY-PROTECTOR-5P | Replacement screen protector (5 pack) |
| ONXF-ETH-ADAPT-M-F | Ethernet Cat6a M-F adapter 0.5 m |
| NSC-ETHERNET-CABLE | Ethernet Cat6a M-M Patch Cable |
| ONXF-HFC-CASE | Fitted protective case for ONX-720/730 with DOCSIS 3.1 |