VIAVI OneExpert ONX-700 series handheld tester, side view
VIAVI / ONX-720/730 / Handheld
ONXF-720-PON-42-85-TSX

OneExpert HFC ONXF-720-PON-42-85-TSX DOCSIS 3.1 and PON Field Tester with 42/85 MHz Module and TSX Package

OneExpert HFC ONX-720 package with a PON selective power meter, VFL, 42/85 MHz DOCSIS 3.1 module and TSX software for 10 Gbps service testing.

Package contents
PON Selective Optical Power Meter, VFL, OneCheck Ethernet, OneCheck WiFi, 10G SpeedCheck, ONX-CATV-D31-S-4285-1012 module (42/85 MHz D3.1), ONX 720 TSX Package, Protective Fitted Case, Cat6A jumper M-F and M-M
DOCSIS configuration
42/85 MHz Upstream 1.0 GHz/1.2 GHz Downstream DOCSIS 3.1
TruePON PON-ID Analysis with OLT-ID and Loss
Optional
Broadband Power Capability for Selective PON Hardware
Included
Datasheet

Overview

The VIAVI OneExpert HFC ONXF-720-PON-42-85-TSX is a new-unit ordering package of the OneExpert HFC ONX-720. The ONX-720/730 platform validates DOCSIS, Ethernet, PON and WiFi 7 throughput up to 10 Gbps in under a minute. It is built for installation and service technicians testing residential and small business services.

This package combines the ONX-720 mainframe with a PON Selective Optical Power Meter, a Visual Fault Locator, OneCheck Ethernet, OneCheck WiFi and 10G SpeedCheck. It also includes the ONX-CATV-D31-S-4285-1012 DOCSIS 3.1 module (42/85 MHz upstream, 1.0 GHz/1.2 GHz downstream), the ONX 720 TSX software package, a protective fitted case and Cat6A M-F and M-M jumpers.

Optical testing

The selective power meter measures coexistent PON wavelengths separately and reads the PON-ID to confirm connection to the expected OLT. With the optional TruePON software, the unit automatically checks Total Optical Loss, PON-ID, OLT connectivity and received power against the ODN class. A 1 mW VFL and support for USB fiber scopes with automatic pass/fail analysis help locate faults in the fiber.

DOCSIS and RF

The ONX-720/730 carries over the RF and DOCSIS testing features of the ONX-620/630 and supports the existing RF modules. Test Process Automation provides one-button OneCheck workflows that save geo-tagged results. The IP54-rated modular design has an upgrade path to 25G/50G PON and DOCSIS 4.0, along with integrated GPS, StrataSync and mobile app support.

Key Features

  • PON Selective Optical Power Meter with SC/APC connection
  • Visual Fault Locator (1 mW)
  • ONX-CATV-D31-S-4285-1012 DOCSIS 3.1 module (42/85 MHz)
  • ONX 720 TSX software package
  • OneCheck Ethernet and OneCheck WiFi 7 automated pass/fail testing
  • VIAVI SpeedCheck to 5 Gbps and 10 Gbps
  • Broadband power capability for the selective PON hardware
  • Optional TruePON PON-ID analysis with OLT-ID and loss
  • Optional OneCheck PON with GPON/XGS-PON emulation using VIAVI SFP
  • 10GBase-T RJ-45 electrical Ethernet test port
  • USB fiber scope support with Auto Analysis
  • IP54 rated, drop-tested to 1 m onto concrete
  • Field-replaceable 96 W/hr Li-Ion battery
  • Integrated GPS, StrataSync and VIAVI Mobile Tech app support
  • Modular upgrade path to 25G/50G PON and DOCSIS 4.0

Specifications

Package Configuration
Package contents PON Selective Optical Power Meter, VFL, OneCheck Ethernet, OneCheck WiFi, 10G SpeedCheck, ONX-CATV-D31-S-4285-1012 module (42/85 MHz D3.1), ONX 720 TSX Package, Protective Fitted Case, Cat6A jumper M-F and M-M
DOCSIS configuration 42/85 MHz Upstream 1.0 GHz/1.2 GHz Downstream DOCSIS 3.1
The module compatibility table on page 7 describes ONX-CATV-D31-S-4285-1012 as '45/85 MHz 1.0/1.2 GHz'
TruePON PON-ID Analysis with OLT-ID and Loss Optional
Broadband Power Capability for Selective PON Hardware Included
Return Signal Generator w/Loopback Optional
Ingress Expert Optional
HomeTDR / Home Leakage Test Optional
Ethernet
Standard IEEE 802.3 100M, 1G, 2.5G, 5G, and 10G Ethernet
Test Results Ethernet Frames, IP Connectivity, Ping, Trace route, Web Connectivity, Speed Test up to 10 Gbps
10GBase-T RJ-45 Electrical 100M, 1G, 2.5G, 5G, 10G
SFP+ Optical Ethernet 1G, 10G (SFP dependent)
Optional
SFP+ Electrical Ethernet 100M, 1G, 2.5G, 5G, 10G
Optional
WiFi
OneCheck WiFi (Connected Mode) WiFi - 7 2x2 (802.11 a/b/g/n/ac/ax/be) 2.4, 5, 6 GHz bands
Test Results Signal strength (RSSI), Standard, Width, Max Router PHY Rate, IP/Web connectivity, Throughput Tests (SpeedCheck, Ookla Speedtest, iPerf)
Throughput/Performance Tests
TCP Throughput Test VIAVI SpeedCheck: 5 Gbps, 10 Gbps; Ookla Speedtest: 5 Gbps, 10 Gbps; VIAVI TrueSpeed (RFC-6349): 5 Gbps, 10 Gbps
Ookla Speedtest and TrueSpeed are options
Performance Up to 10 Gbps for SpeedCheck, Ookla Speedtest, TrueSpeed, iPerf client: 5 Gbps, 10 Gbps
Test Results Delay, Upstream and Downstream Bit Rates
Bluetooth and Smart Device
Communication Interface Bluetooth v5.0, BLE 2.0
Smart Device Support VIAVI Mobile Tech app, Android 8 or newer, iOS 12 or newer
Recommendation
Optical Fiber Scope Support
USB Optical Fiber Scope P5000i, FiberChek Probe
Results for Zone Defects / Scratches Pass/Fail
Low Mag Field-of-View (FOV) Horizontal 740 μm, Vertical 550 μm
High Mag Field-of-View (FOV) Horizontal 370 μm, Vertical 275 μm
Particle Size Detection <1 μm
Power Source USB port
Selective PON Power Meter
Photo Diode InGaAs
Spectral Range Passband (1260…1500 nm, 1540…1650 nm)
Wavelength Setting 1342, 1358, 1490, 1577 nm; Dual: 1490/1577, 1342/1577, 1358/1577 nm; Broadband: 1270...1650 nm, Custom step size 1 nm
Broadband in Broadband Mode (activated SW option required)
Resolution 0.01 dB, 0.001 µW
Measurement Range for Power Level -45…+3 dBm
Max. Power Level +15 dBm
Measurement Uncertainty 1490 nm: ±0.5 dB/±12 %; 1577 nm: ±0.5 dB/±12 %; 1342 nm: ±0.5 dB/±12 %; 1358 nm: ±0.5 dB/±12 %; Broadband: ±0.5 d/±5 %
Under reference conditions: -2 dBm (CW), nominal wavelength, 23 °C ±3 K, 45 to 75% relative humidity, SM test fiber (9 µm core, 8° APC), SC/APC connectors
Measurement Range for PON-ID GPON: -30...0 dBm; XGS-PON: -25...0 dBm
Number of Calibrated Wavelengths 2 (1490, 1577 nm)
Tone Detection 270 Hz, 330 Hz, 1 kHz, 2 kHz
Future optional capability; in Broadband Mode (activated SW option required)
Connection SC/APC
Visual Fault Locator (VFL)
Fiber Compatibility Single-mode, Multimode
Wavelength 650 nm (visible)
Output Modes Continuous and flashing
Connector Interface Universal 2.5 mm (fixed)
Output Power 1 mW
Laser Safety Rating Class 2
Range (maximum) 7 km
VFL range depends on many factors, including fiber quality/loss
General
Size 5.0 x 11.1 x 4.25 in (W x L x H)
ONX-720 and ONX-730 with RF Module
Weight 3.15 kg (6.9 lb)
Without protective case; ONX-720 and ONX-730 with RF Module
Operating Temperature Range Non-Charging: -10°C to 50°C; Battery Charging: 0°C to 40°C
Storage Temperature Range -20°C to 60°C
Operating Humidity Range 10% to 90% RH, non-condensing
For Indoor/Outdoor Use IP54 light rain (0.5 in/hr; 1.27 cm/hr)
Drop Rating 1 m (3.3 ft) onto concrete
Operating Altitude 4000 m max
RF immunity 8.5 V/m
For CATV measurements
DC Input Power 12 V@5 A
DC Charge Port 2.5 mm barrel
Battery 96 W/hr Li-Ion rechargeable battery, Field replaceable
Battery Charge Time 4 Hrs (90%) 6-8 Hrs 100% (AC charger)
Battery Life 3-5 day typical usage for installation technicians
10 installs a day
USB Host Port(s) USB-C, USB-A (USB 3.0)
DOCSIS/RF Frequency and Downstream (Port 1)
Frequency Range 0.5 to 1,218 MHz
Frequency Accuracy ±10 ppm
Typical @25°C
Max Input Power 60 dBmV total integrated power
Operation on Powered TAP Operate with up to 90 VAC/DC on input port
Return Loss >9 dB
Auto Channel Plan Builder Auto detection of channels (analog, digital, QAM, OFDM)
Diplexer (42 MHz) upstream 4-42 MHz; downstream 54–1,004 MHz
Diplexer return path options may not be available on all units
Diplexer (85 MHz) upstream 4-85 MHz; downstream 108-1,218 MHz
Diplexer return path options may not be available on all units
MoCA filter All models have MoCA triplexer to filter out MoCA signals below the highest downstream frequency
Upstream Analysis (Port 2)
Ingress Spectrum Scan 0.5–204 MHz, calibrated range 4-204 MHz
Sensitivity −45 dBmV
RBW 300 kHz
Min Detectable Level Upstream −55 dBmV
Dynamic Range 50 dB
Max Total Integrated Power 55 dBmV, 4–10 MHz, 60 dBmV, 10 to 204 MHz
Accuracy ±2 dB
Typical at 25°C
Sampling Rate Hyper Spectrum FFT Gapless technology - no missed samples, spans 0.5 to 110 MHz, 110 to 160 MHz, and 160 to 204 MHz
Return Loss >9.5 dB
Downstream Digital Channel Analysis
Calibrated Power Levels -20 dBmV to +50 dBmV
Level Accuracy ±1.5 dB from −20 dBmV to +50 dBmV typical at 25°C; ±2.0 dB, −20°C to +50°C
Modulation(s) 64, 128, and 256 QAM, OFDM
OFDM Channels 24-192 MHz wide − up to 3 active OFDM channels
Profile Analysis Profiles A, B, C, D, NCP, and PLC (more profiles as implemented)
MER Specified range 21 to 40 dB, 64 QAM; 28 to 40 dB, 256 QAM; 16 to 44 dB, OFDM
At −5 to +20 dBmV; MER range declines as input levels decrease
Minimum Lock Level −15 dBmV
BER — Channel Check and DOCSIS Check mode Down to 1E-9 (pre and post FEC)
Sweep
Forward Sweep Telemetry Frequency Diplexer dependent 50-1,218 MHz
Forward Sweep Compatibility SCU-1800
Reverse Sweep Port 1 Frequency Range Diplexer dependent 5-42/5-65/5-85/5-204 MHz
Reverse Sweep Port 2 Frequency Range 5-204 MHz
Reverse Sweep Compatibility SCU-1800 or DAA/RPHY via XperTRAK

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • DOCSIS service activation and troubleshooting
  • PON service turn-up (GPON, XGS-PON)
  • Multi-gig Ethernet throughput validation
  • WiFi 7 service delivery testing
  • Residential and small business installations
  • Upstream ingress troubleshooting

Included

  • ONX-CATV-D31-S-4285-1012 module (42/85 MHz D3.1)
  • ONX 720 TSX Package
  • Protective Fitted Case
  • Cat6A jumper M-F and M-M

Options & Accessories

Option Description
ONXF-SW-TRUEPON TruePON software option — Requires PON selective HW
ONXF-SW-SFP-ETH Enable SFP+ port for Optical Ethernet testing over VIAVI supported SFP's
ONXF-SW-OC-PON OneCheck PON – PON testing via GPON/XGSPON SFP+
ONXF-SW-OC-GPON-EMUL GPON Emulation for live service testing on GPON network
ONXF-SW-OC-XGSPON-EMUL XGS-PON emulation for live service testing — Datasheet lists the description as 'GPON Emulation for live service testing on GPON network'
ONX-SMART-ACCESS Smart Access Anywhere
ONXF-SW-OOKLA-SPD-10G ONX Ookla Speedtest to 10 Gbps
ONXF-SW-OOKLA-SPD-5G ONX Ookla Speedtest to 5 Gbps
ONXF-SW-TRUESPEED-10G ONX TrueSpeed to 10 Gbps Permanent License
ONXF-SW-TRUESPEED-5G ONX TrueSpeed to 5 Gbps permanent License
ONXF-SW-IPERF-10G ONX iPerf test to 10 Gbps permanent License
ONXF-SW-IPERF-5G ONX iPerf test to 5 Gbps Permanent License
ONX-CATV-SW-HL-LKG Home Leakage Software Option
ONX-CATV-SW-HOMETDR Home TDR Software Option
ONX-CATV-SW-RSG-LOOP Return Signal Generator with Loopback Option
ONX-CATV-SW-INGRESS-EXP Ingress Expert Option for ONX 720's
ONX-CATV-FWD-SWEEP Active Forward Sweep
ONX-CATV-REV-SWEEP Active Reverse Sweep
NSC-SFP-GPON GPON SFP for GPON emulation
NSC-SFP-XGSPON XGSPON SFP+ for XGSPON emulation
NSC-SFP-850-1G-10G Optical Ethernet SFP + 850 nm SR 1G and 10G
NSC-SFP-1310-1G-10G Optical Ethernet SFP + 1310 nm LR 1G and 10G
NSC-SFP-1550-1G-10G Optical Ethernet SFP + 1550 nm ER 1G and 10G
AC-CHARGER Replacement AC charger (no power cord)
AC-CAR-CHARGER Car Charger
CC-034601 Large Carrying Case
1019-00-1366 Strand Hook
ONXF-HANDSTRAP Handstrap for use on unit without a case
ONXF-HFC-BATT-96WHR Replacement 96 W/Hr Battery
ONXF-DISPLAY-PROTECTOR-5P Replacement screen protector (5 pack)
ONXF-ETH-ADAPT-M-F Ethernet Cat6a M-F adapter 0.5 m
NSC-ETHERNET-CABLE Ethernet Cat6a M-M Patch Cable
ONXF-HFC-CASE Fitted protective case for ONX-720/730 with DOCSIS 3.1

Documents & Resources