OneExpert HFC ONXF-720-BB-65-204-TSX DOCSIS 3.1 and Ethernet Tester with Broadband Power Meter (65/204 MHz, TSX)
OneExpert HFC ONX-720 package with broadband optical power meter, VFL, 65/204 MHz DOCSIS 3.1 module and 10 Gbps Ethernet and WiFi 7 testing.
- Optical testing
- Broadband Optical Power Meter, VFL
- Service testing
- OneCheck Ethernet, OneCheck WiFi, 10G SpeedCheck
- DOCSIS module
- ONX-CATV-D31-S-6520-1212 module (65/204 MHz D3.1)
- Software package
- ONX 720 TSX Package
Overview
The VIAVI OneExpert HFC ONXF-720-BB-65-204-TSX is a new-unit package of the ONX-720 handheld tester. It tests DOCSIS, Ethernet, PON and WiFi 7 connections and validates throughput up to 10 Gbps. The package combines a broadband optical power meter and a visual fault locator with OneCheck Ethernet, OneCheck WiFi, 10G SpeedCheck, the ONX 720 TSX software package and the ONX-CATV-D31-S-6520-1212 DOCSIS 3.1 module (65/204 MHz upstream, 1.2 GHz/1.2 GHz downstream).
Test Process Automation
VIAVI Test Process Automation (TPA) gives technicians one-button OneCheck workflows that automate pass/fail testing for DOCSIS, Ethernet, WiFi and PON. Results are saved with geo tags, and guided steps keep installations consistent and reduce repeat visits.
Optical and fiber tools
The integrated broadband optical power meter measures power levels through a dedicated optical port. The 1 mW visual fault locator and support for USB fiber scopes with automatic analysis are used to check fibers and connectors.
DOCSIS and RF
The ONX-720/730 continues the RF and DOCSIS test functions of the ONX-620/630 and supports the existing RF modules. The IP54-rated modular platform includes GPS, StrataSync and mobile app support, and a field-replaceable 96 W/hr battery.
Key Features
- OneCheck Ethernet, OneCheck WiFi and 10G SpeedCheck included
- Broadband optical power meter and visual fault locator included
- ONX-CATV-D31-S-6520-1212 DOCSIS 3.1 module (65/204 MHz) included
- ONX 720 TSX software package
- Unified OneCheck workflow automates pass/fail for DOCSIS, Ethernet, WiFi and PON
- Ethernet and WiFi 7 throughput validation up to 10 Gbps in under a minute
- 10GBase-T RJ-45 port plus optional SFP+ optical and electrical Ethernet
- WiFi 7 2x2 testing on 2.4, 5 and 6 GHz bands
- USB fiber scope support with Auto Analysis and defect detection
- Smart Access Anywhere remote coaching and training via PC or mobile connection (optional)
- IP54 rated, drop-tested, modular design
- Modular path supports 25G/50G PON and DOCSIS 4.0 upgrades
- Integrated GPS, StrataSync and VIAVI Mobile Tech app support
- 96 W/hr field-replaceable Li-Ion battery for multi-day use
Specifications
| Optical testing | Broadband Optical Power Meter, VFL |
|---|---|
| Service testing | OneCheck Ethernet, OneCheck WiFi, 10G SpeedCheck |
| DOCSIS module |
ONX-CATV-D31-S-6520-1212 module (65/204 MHz D3.1)
65/204 MHz Upstream 1.2 GHz/1.2 GHz Downstream DOCSIS 3.1 Packages
|
| Software package | ONX 720 TSX Package |
| Standard | IEEE 802.3 100M, 1G, 2.5G, 5G, and 10G Ethernet |
|---|---|
| Test results | Ethernet Frames, IP Connectivity, Ping, Trace route, Web Connectivity, Speed Test up to 10 Gbps |
| 10GBase-T RJ-45 Electrical | 100M, 1G, 2.5G, 5G, 10G |
| SFP+ Optical Ethernet |
1G, 10G
SFP dependent; optional
|
| SFP+ Electrical Ethernet |
100M, 1G, 2.5G, 5G, 10G
Optional
|
| OneCheck WiFi (Connected Mode) | WiFi - 7 2x2 (802.11 a/b/g/n/ac/ax/be) 2.4, 5, 6 GHz bands |
|---|---|
| Test results | Signal strength (RSSI), Standard, Width, Max Router PHY Rate, IP/Web connectivity, Throughput Tests (SpeedCheck, Ookla Speedtest, iPerf) |
| VIAVI SpeedCheck |
5 Gbps, 10 Gbps
Standard
|
|---|---|
| Ookla Speedtest |
5 Gbps, 10 Gbps
Optional
|
| VIAVI TrueSpeed (RFC-6349) |
5 Gbps, 10 Gbps
Optional
|
| iPerf client |
5 Gbps, 10 Gbps
Optional
|
| Test results | Delay, Upstream and Downstream Bit Rates |
| Communication interface | Bluetooth v5.0, BLE 2.0 |
|---|---|
| Smart device support |
VIAVI Mobile Tech app, Android 8 or newer, iOS12 or newer
Recommendation
|
| USB optical fiber scope | P5000i, FiberChek Probe |
|---|---|
| Results for zone defects / scratches | Pass/Fail |
| Low Mag Field-of-View (FOV) | Horizontal 740 μm, Vertical 550 μm |
| High Mag Field-of-View (FOV) | Horizontal 370 μm, Vertical 275 μm |
| Particle size detection | <1 μm |
| Power source | USB port |
| Photo diode | InGaAs |
|---|---|
| Spectral range | Broadband (800…1650 nm) |
| Wavelength setting | 850, 980, 1310, 1490, 1550, 1577, 1625, 1650 nm; Custom 800…1650 nm, step size 1 nm |
| Resolution | 0.01 dB, 0.001 μW |
| Measurement range for power level | -65…+10 dBm |
| Max. power level | +16 dBm |
| Measurement uncertainty |
±0.2 dB/±5% (intrinsic)
Under reference conditions: -11 dBm (CW), 1310 nm ±1 nm, 23 °C ±3 K, 45 to 75% relative humidity, SM test fiber (Single Mode, 9 µm core, 8° APC), when used with SC/PC connectors
|
| Number of calibrated wavelengths | 8 (850, 980, 1310, 1490, 1550, 1577, 1625, 1650 nm) |
| Tone detection |
270 Hz, 330 Hz, 1 kHz, 2 kHz
Future optional capability; received optical power level ≥ -50 dBm
|
| Connection | UPP 2.5 mm |
| Fiber compatibility | Single-mode, Multimode |
|---|---|
| Wavelength | 650 nm (visible) |
| Output modes | Continuous and flashing |
| Connector interface | Universal 2.5 mm (fixed) |
| Output power | 1 mW |
| Laser safety rating | Class 2 |
| Range (maximum) |
7 km
VFL range depends on many factors, including fiber quality/loss
|
| Size |
5.0 x 11.1 x 4.25 in (W x L x H)
ONX-720 and ONX-730 with RF Module
|
|---|---|
| Weight |
3.15 kg (6.9 lb)
With RF Module, without protective case
|
| Operating temperature range | Non-Charging: -10°C to 50°C; Battery Charging: 0°C to 40°C |
| Storage temperature range | -20°C to 60°C |
| Operating humidity range | 10% to 90% RH, non-condensing |
| Indoor/outdoor use | IP54 light rain (0.5 in/hr; 1.27 cm/hr) |
| Drop rating | 1 m (3.3 ft) onto concrete |
| Operating altitude | 4000 m max |
| Pollution | 2° |
| RF immunity |
8.5 V/m
For CATV measurements
|
| DC input power | 12 V@5 A |
| DC charge port | 2.5 mm barrel |
| Battery | 96 W/hr Li-Ion rechargeable battery, Field replaceable |
| Battery charge time | 4 Hrs (90%) 6-8 Hrs 100% (AC charger) |
| Battery life | 3-5 day typical usage for installation technicians (10 installs a day) |
| USB host port(s) | USB-C, USB-A (USB 3.0) |
| Frequency range | 0.5 to 1,218 MHz |
|---|---|
| Frequency accuracy |
±10 ppm
Typical @25°C
|
| Max input power | 60 dBmV total integrated power |
| Operation on powered TAP | Operate with up to 90 VAC/DC on input port |
| Power detection/notification | Notify of AC/DC power presence on port 1 above 2 Volts |
| Return loss | >9 dB |
| Auto channel plan builder | Auto detection of channels (analog, digital, QAM, OFDM) |
| Ingress spectrum scan | 0.5–204 MHz, calibrated range 4-204 MHz |
|---|---|
| Sensitivity | −45 dBmV |
| RBW | 300 kHz |
| Min detectable level upstream | −55 dBmV |
| Dynamic range | 50 dB |
| Max total integrated power | 55 dBmV, 4–10 MHz, 60 dBmV, 10 to 204 MHz |
| Accuracy |
±2 dB
Typical at 25°C
|
| Sampling rate | Hyper Spectrum FFT Gapless technology - no missed samples, spans 0.5 to 110 MHz, 110 to 160 MHz, and 160 to 204 MHz |
| Return loss | >9.5 dB |
| Power detection/notification | Notify of AC/DC power presence on port 2 above 2 Volts |
| Analog standards | NTSC, PAL, SECAM |
|---|---|
| Analog min detectable signal | −50 dBmV (single channel) |
| Level accuracy | ±1.5 dB from −20 dBmV to +50 dBmV typical at 25°C; ±2.0 dB, −20°C to +50°C |
| Digital calibrated power levels | -20 dBmV to +50 dBmV |
| Modulation(s) | 64, 128, and 256 QAM, OFDM |
| Annex A | 5.057 to 6.952 MSPS for 64, 128, and 256 QAM |
| Annex B | 5.057 MSPS for 64 QAM and 5.361 MSPS for 256 QAM |
| Annex C | 5.274 MSPS for 64 QAM, and 5.361 MSPS for 256 QAM |
| Regional demods | DVB-C |
| OFDM channels | 24-192 MHz wide − up to 3 active OFDM channels |
|---|---|
| OFDM MER — max, min, average, standard deviation, percentile | 16 to 44 dB |
| Profile analysis | Profiles A, B, C, D, NCP, and PLC (more profiles as implemented) |
| MER specified range |
−5 to +20 dBmV 21 to 40 dB, 64 QAM; 28 to 40 dB, 256 QAM; 16 to 44 dB, OFDM
MER range declines as input levels decrease. Expected MER range at MINLOCK level of –15 dBmV is >30 dB MER.
|
| MER max displayable range | 50 dB |
| MER resolution | 0.1 dB |
| MER accuracy |
±2 dB
Typical at 25°C
|
| Minimum lock level | −15 dBmV |
| BER — Channel Check and DOCSIS Check mode | Down to 1E-9 (pre and post FEC) |
| BER — OneCheck Mode | Down to 1E-8 (pre and post FEC) Std. 1E-9 user selectable |
| Interleaver depth | 128, 8 max |
| RF (2) | F connectors replaceable |
|---|---|
| Port 2 | Upstream 0.5–204 MHz and TDR |
| Diplexer 65 MHz |
upstream 4-65 MHz; downstream 85-1,218 MHz
Diplexer return path options may not be available on all units
|
| Diplexer 204 MHz |
upstream 4-204 MHz: downstream 258-1,218 MHz
Diplexer return path options may not be available on all units
|
| MoCA filter | All models have MoCA triplexer to filter out MoCA signals below the highest downstream frequency |
| Forward sweep telemetry frequency |
Diplexer dependent 50-1,218 MHz
Input port: Port 1; compatibility: SCU-1800
|
| Reverse sweep output transmit port | Port 1 or Port 2 (user selectable) |
| Port 2 sweep frequency range | 5-204 MHz |
| Reverse sweep compatibility | SCU-1800 or DAA/RPHY via XperTRAK |
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- Residential service activation
- Small business service testing
- DOCSIS service turn-up and troubleshooting
- Multi-gig Ethernet throughput validation
- WiFi 7 service delivery testing
- Fiber optical power and continuity checks
- Upstream ingress analysis
Included
- Broadband Optical Power Meter
- VFL
- OneCheck Ethernet
- OneCheck WiFi
- 10G SpeedCheck
- ONX-CATV-D31-S-6520-1212 module (65/204 MHz D3.1)
- ONX 720 TSX Package
- Protective Fitted Case
- Cat6A jumper M-F and M-M
Options & Accessories
| Option | Description |
|---|---|
| ONXF-SW-SFP-ETH | Enable SFP+ port for Optical Ethernet testing over VIAVI supported SFP’s |
| ONXF-SW-OPTICAL-LOSS | Optical Loss test mode option to save reference and calculate loss |
| ONXF-SW-OC-PON | OneCheck PON – PON testing via GPON/XGSPON SFP+ |
| ONXF-SW-OC-GPON-EMUL | GPON Emulation for live service testing on GPON network |
| ONXF-SW-OC-XGSPON-EMUL | GPON Emulation for live service testing on GPON network |
| ONX-SMART-ACCESS | Smart Access Anywhere |
| ONXF-SW-OOKLA-SPD-5G-1Y | ONX Ookla Speedtest to 5 Gbps 1 Yr Timed License/ deployed via StrataSync |
| ONXF-SW-OOKLA-SPD-5G-3Y | ONX Ookla Speedtest to 5 Gbps 3 Yr Timed License/deployed via StrataSync |
| ONXF-SW-OOKLA-SPD-5G-5Y | ONX Ookla Speedtest to 5 Gbps 5 Yr Timed License/deployed via StrataSync |
| ONXF-SW-OOKLA-SPD-5G | ONX Ookla Speedtest to 5 Gbps |
| ONXF-SW-OOKLA-SPD-10G-1Y | ONX Ookla Speedtest to 10 Gbps 1 Yr Timed License/ deployed via StrataSync |
| ONXF-SW-OOKLA-SPD-10G-3Y | ONX Ookla Speedtest to 10 Gbps 3 Yr Timed License/deployed via StrataSync |
| ONXF-SW-OOKLA-SPD-10G-5Y | ONX Ookla Speedtest to 10 Gbps 5 Yr Timed License/deployed via StrataSync |
| ONXF-SW-OOKLA-SPD-10G | ONX Ookla Speedtest to 10 Gbps |
| ONXF-SW-TRUESPEED-5G-1Y | ONX TrueSpeed to 5 Gbps 1 Yr Timed License/ deployed via StrataSync |
| ONXF-SW-TRUESPEED-5G-3Y | ONX TrueSpeed to 5 Gbps 3 Yr Timed License/deployed via StrataSync |
| ONXF-SW-TRUESPEED-5G | ONX TrueSpeed to 5 Gbps permanent License |
| ONXF-SW-TRUESPEED-10G-1Y | ONX TrueSpeed to 10 Gbps 1 Yr Timed License/ deployed via StrataSync |
| ONXF-SW-TRUESPEED-10G-3Y | ONX TrueSpeed to 10 Gbps 3 Yr Timed License/deployed via StrataSync |
| ONXF-SW-TRUESPEED-10G | ONX TrueSpeed to 10 Gbps Permanent License |
| ONXF-SW-IPERF-5G-1Y | ONX iPerf test to 5 Gbps 1 Yr Timed License/deployed via StrataSync |
| ONXF-SW-IPERF-5G-3Y | ONX iPerf test to 5 Gbps 3 Yr Timed License/deployed via StrataSync |
| ONXF-SW-IPERF-5G | ONX iPerf test to 5 Gbps Permanent License |
| ONXF-SW-IPERF-10G-1Y | ONX iPerf test to 10 Gbps 1 Yr Timed License/deployed via StrataSync |
| ONXF-SW-IPERF-10G-3Y | ONX iPerf test to 10 Gbps 3 Yr Timed License/deployed via StrataSync |
| ONXF-SW-IPERF-10G | ONX iPerf test to 10 Gbps permanent License |
| ONX-CATV-SW-HL-LKG | Home Leakage Software Option |
| ONX-CATV-SW-HOMETDR | Home TDR Software Option |
| ONX-CATV-SW-RSG-LOOP | Return Signal Generator with Loopback Option |
| ONX-CATV-SW-INGRESS-EXP | Ingress Expert Option for ONX 720’s |
| ONX-CATV-SW-RP-SNR-OCE | Return Path SNR in OneCheck Expert - OneExpert CATV |
| ONX-CATV-FWD-SWEEP | Active Forward Sweep |
| ONX-CATV-REV-SWEEP | Active Reverse Sweep |
| NSC-SFP-GPON | GPON SFP for GPON emulation |
| NSC-SFP-XGSPON | XGSPON SFP+ for XGSPON emulation |
| NSC-SFP-850-1G-10G | Optical Ethernet SFP + 850 nm SR 1G and 10G |
| NSC-SFP-1310-1G-10G | Optical Ethernet SFP + 1310 nm LR 1G and 10G |
| NSC-SFP-1550-1G-10G | Optical Ethernet SFP + 1550 nm ER 1G and 10G |
| AC-CHARGER | Replacement AC charger (no power cord) |
| AC-CAR-CHARGER | Car Charger |
| CC-034601 | Large Carrying Case |
| 1019-00-1366 | Strand Hook |
| ONXF-HANDSTRAP | Handstrap for use on unit without a case |
| ONXF-HFC-BATT-96WHR | Replacement 96 W/Hr Battery |
| ONXF-DISPLAY-PROTECTOR-5P | Replacement screen protector (5 pack) |
| ONXF-ETH-ADAPT-M-F | Ethernet Cat6a M-F adapter 0.5 m |
| NSC-ETHERNET-CABLE | Ethernet Cat6a M-M Patch Cable |
| ONXF-HFC-CASE | Fitted protective case for ONX-720/730 with DOCSIS 3.1 |