VIAVI OneExpert ONX-700 platform handheld tester, side view
VIAVI / ONX-720/730 / Handheld Testers
ONXF-720-85-204-IPX

OneExpert HFC ONXF-720-85-204-IPX DOCSIS 3.1 and 10G Ethernet/WiFi 7 Field Tester (85/204 MHz, IPX Package)

OneExpert HFC ONX-720 new-unit package with 85/204 MHz DOCSIS 3.1 module, OneCheck Ethernet, OneCheck WiFi and 10G SpeedCheck

Fiber optic testing
No Optics
DOCSIS module
ONX-CATV-D31-S-8520-1212 module (85/204 MHz D3.1)
Software package
ONX-720 IPX Package
Standard test applications
OneCheck Ethernet, OneCheck WiFi, 10G SpeedCheck
Datasheet

Overview

The ONXF-720-85-204-IPX is a new-unit ordering package of the VIAVI OneExpert HFC (ONX-720/730) platform. It combines an ONX-720 mainframe with the ONX-CATV-D31-S-8520-1212 DOCSIS 3.1 sweep-ready module (85/204 MHz upstream, 1.2 GHz/1.2 GHz downstream) and the ONX-720 IPX software package. It is a No Optics package, so it does not include an optical power meter or visual fault locator.

The OneExpert HFC validates DOCSIS, Ethernet and WiFi 7 throughput up to 10 Gbps in under a minute. OneCheck Ethernet, OneCheck WiFi and 10G VIAVI SpeedCheck are included as standard. VIAVI Test Process Automation (TPA) provides one-button guided test workflows with pass/fail results, which are intended to improve process compliance and reduce repeat visits.

DOCSIS and RF

The ONX-720/730 extends the ONX-620/630 by keeping their RF and DOCSIS testing features, including support for existing RF modules. The DOCSIS/RF functions cover downstream analog and digital channel analysis, OFDM signal performance metrics, upstream ingress spectrum scan, and forward and reverse sweep compatible with the SCU-1800.

Design

The unit is IP54 rated, weatherproof and drop-tested. Its modular design supports future 25G/50G PON and DOCSIS 4.0 upgrades. It includes GPS, StrataSync connectivity, VIAVI Mobile Tech app support over Bluetooth, and a field-replaceable 96 W/hr battery for multi-day use.

Key Features

  • ONX-720 mainframe with ONX-CATV-D31-S-8520-1212 module (85/204 MHz D3.1)
  • ONX-720 IPX software package
  • OneCheck Ethernet and OneCheck WiFi included
  • 10G VIAVI SpeedCheck included
  • Ethernet, DOCSIS and WiFi 7 throughput validation up to 10 Gbps in under a minute
  • Unified OneCheck workflow automates pass/fail for DOCSIS, Ethernet and WiFi
  • 10GBase-T RJ-45 electrical Ethernet port: 100M, 1G, 2.5G, 5G, 10G
  • WiFi 7 2x2 (802.11 a/b/g/n/ac/ax/be) on 2.4, 5 and 6 GHz bands
  • USB optical fiber scope support with Auto Analysis
  • Smart Access Anywhere remote coaching and training via PC or mobile connection (optional)
  • IP54 rated, drop-tested, modular design ready for 25G/50G PON and DOCSIS 4.0
  • Integrated GPS, StrataSync and VIAVI Mobile Tech app support
  • Field-replaceable 96 W/hr Li-Ion battery for multi-day use

Specifications

Package Configuration
Fiber optic testing No Optics
Broadband Optical Power Meter, PON Selective Optical Power Meter and VFL: N/A
DOCSIS module ONX-CATV-D31-S-8520-1212 module (85/204 MHz D3.1)
85/204 MHz Upstream 1.2 GHz/1.2 GHz Downstream DOCSIS 3.1 Packages
Software package ONX-720 IPX Package
Standard test applications OneCheck Ethernet, OneCheck WiFi, 10G SpeedCheck
Optional applications Optical Ethernet Testing over SFP+, OneCheck PON w/Emulation, Ookla Speedtest, VIAVI TrueSpeed, iPerf, Smart Access Anywhere, HomeTDR, Home Leakage Test, Return Signal Generator w/Loopback, Ingress Expert
Reverse Sweepless Sweep, QAM Video MPEG Verification and Field View w/RSG: N/A
Ethernet
Standard IEEE 802.3 100M, 1G, 2.5G, 5G, and 10G Ethernet
Test results Ethernet Frames, IP Connectivity, Ping, Trace route, Web Connectivity, Speed Test up to 10 Gbps
10GBase-T RJ-45 electrical 100M, 1G, 2.5G, 5G, 10G
SFP+ optical Ethernet 1G, 10G (SFP dependent)
Optional
SFP+ electrical Ethernet 100M, 1G, 2.5G, 5G, 10G
Optional
WiFi
OneCheck WiFi (Connected Mode) WiFi - 7 2x2 (802.11 a/b/g/n/ac/ax/be) 2.4, 5, 6 GHz bands
Test results Signal strength (RSSI), Standard, Width, Max Router PHY Rate, IP/Web connectivity, Throughput Tests (SpeedCheck, Ookla Speedtest, iPerf)
Throughput/Performance Tests
VIAVI SpeedCheck 5 Gbps, 10 Gbps
TCP throughput test
Ookla Speedtest 5 Gbps, 10 Gbps
Optional
VIAVI TrueSpeed (RFC-6349) 5 Gbps, 10 Gbps
Optional
iPerf client 5 Gbps, 10 Gbps
Optional
Test results Delay, Upstream and Downstream Bit Rates
Bluetooth and Smart Device Support
Communication interface Bluetooth v5.0, BLE 2.0
Smart device support VIAVI Mobile Tech app, Android 8 or newer, iOS12 or newer
Recommendation
Optical Fiber Scope Support
USB optical fiber scope P5000i, FiberChek Probe
Results for zone defects / scratches Pass/Fail
Low mag field-of-view (FOV) Horizontal 740 μm, Vertical 550 μm
High mag field-of-view (FOV) Horizontal 370 μm, Vertical 275 μm
Particle size detection <1 μm
Power source USB port
DOCSIS/RF Frequency
Range 0.5 to 1,218 MHz
Accuracy ±10 ppm
typical @25°C
Downstream Analysis — Port 1
Max input power 60 dBmV total integrated power
Operation on powered TAP Operate with up to 90 VAC/DC on input port
Power detection/notification Notify of AC/DC power presence on port 1 above 2 Volts
Return loss >9 dB
Auto channel plan builder Auto detection of channels (analog, digital, QAM, OFDM)
Upstream Analysis — Port 2
Ingress spectrum scan 0.5–204 MHz, calibrated range 4-204 MHz
Sensitivity −45 dBmV
RBW 300 kHz
Min detectable level upstream −55 dBmV
Dynamic range 50 dB
Max total integrated power 55 dBmV, 4–10 MHz, 60 dBmV, 10 to 204 MHz
Accuracy ±2 dB
typical at 25°C
Sampling rate Hyper Spectrum FFT Gapless technology - no missed samples, spans 0.5 to 110 MHz, 110 to 160 MHz, and 160 to 204 MHz
Return loss >9.5 dB
Operation on powered TAP Operate with up to 90 V AC/DC on input port
Power detection/notification Notify of AC/DC power presence on port 2 above 2 Volts
Analog Channel Measurement
Standards NTSC, PAL, SECAM
Video and audio levels (dual)
Min detectable signal −50 dBmV
single channel
Level accuracy ±1.5 dB from −20 dBmV to +50 dBmV typical at 25°C; ±2.0 dB, −20°C to +50°C
RBW 300 kHz
Downstream Digital Channel Analysis
Calibrated power levels -20 dBmV to +50 dBmV
Level accuracy ±1.5 dB from −20 dBmV to +50 dBmV typical at 25°C; ±2.0 dB, −20°C to +50°C
Modulation(s) 64, 128, and 256 QAM, OFDM
Annex A 5.057 to 6.952 MSPS for 64, 128, and 256 QAM
Annex B 5.057 MSPS for 64 QAM and 5.361 MSPS for 256 QAM
Annex C 5.274 MSPS for 64 QAM, and 5.361 MSPS for 256 QAM
Regional demods DVB-C
Measurements Full span MER; Ingress under carrier — full span ingress noise trace; Group delay and in-channel response (ICR); Digital quality index (DQI) overtime; Errored/severely errored seconds; Level, measured symbol rate, carrier frequency, modulation, interleaver depth
OFDM Signal Performance Metrics
OFDM channels 24-192 MHz wide − up to 3 active OFDM channels
Level — max, min, average, standard deviation Relative to a 6 MHz carrier per CableLabs®
MER — max, min, average, standard deviation, percentile 16 to 44 dB
MER channel band graph Max, min, avg across entire OFDM carrier MER per subcarrier
ICFR In-carrier frequency response (dB)
Spectrum/IUC Spectrum display, including carrier and ingress under carrier
Profile analysis Profiles A, B, C, D, NCP, and PLC (more profiles as implemented); Lock status, code word errors (corrected and uncorrected)
MER and BER
MER specified range −5 to +20 dBmV 21 to 40 dB, 64 QAM; 28 to 40 dB, 256 QAM; 16 to 44 dB, OFDM
MER range declines as input levels decrease. Expected MER range at MINLOCK level of –15 dBmV is >30 dB MER.
Max displayable range 50 dB
Resolution 0.1 dB
Accuracy ±2 dB
typical at 25°C
Minimum lock level −15 dBmV
BER — Channel Check and DOCSIS Check mode Down to 1E-9 (pre and post FEC)
BER — OneCheck mode Down to 1E-8 (pre and post FEC) Std. 1E-9 user selectable
Interleaver depth 128, 8 max
RF Module Inputs/Outputs
RF (2) F connectors replaceable
Port 1 Downstream 54/85/108/258MHz depending on diplexer
Port 2 Upstream 0.5–204 MHz and TDR
Diplexer 85 MHz upstream 4-85 MHz; downstream 108-1,218 MHz
Diplexer return path options may not be available on all units
Diplexer 204 MHz upstream 4-204 MHz: downstream 258-1,218 MHz
Diplexer return path options may not be available on all units
MoCA filter All models have MoCA triplexer to filter out MoCA signals below the highest downstream frequency
RF immunity 8.5 V/m (for CATV measurements)
Sweep
Forward sweep telemetry frequency Diplexer dependent 50-1,218 MHz
Input port: Port 1
Forward sweep compatibility SCU-1800
Reverse sweep output transmit port Port 1 or Port 2 (user selectable)
Port 1 sweep frequency range Diplexer dependent 5-42/5-65/5-85/5-204 MHz
Port 2 sweep frequency range 5-204 MHz
Reverse sweep compatibility SCU-1800 or DAA/RPHY via XperTRAK
General
Size 5.0 x 11.1 x 4.25 in (W x L x H)
ONX-720 and ONX-730 with RF Module
Weight 3.15 kg (6.9 lb)
ONX-720 and ONX-730 with RF Module, without protective case
Operating temperature range Non-Charging: -10°C to 50°C; Battery Charging: 0°C to 40°C
Storage temperature range -20°C to 60°C
Operating humidity range 10% to 90% RH, non-condensing
Indoor/outdoor use IP54 light rain (0.5 in/hr; 1.27 cm/hr)
Drop rating 1 m (3.3 ft) onto concrete
Operating altitude 4000 m max
Pollution 2°
USB host port(s) USB-C, USB-A (USB 3.0)
Power
DC input power 12 V@5 A
DC charge port 2.5 mm barrel
Battery 96 W/hr Li-Ion rechargeable battery, Field replaceable
Battery charge time 4 Hrs (90%) 6-8 Hrs 100% (AC charger)
Battery life 3-5 day typical usage for installation technicians
10 installs a day

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • DOCSIS service activation
  • Multi-gig residential service installation
  • Small business service testing
  • Ethernet throughput validation
  • WiFi 7 service delivery verification
  • Upstream ingress troubleshooting
  • HFC forward and reverse sweep

Included

  • ONX-CATV-D31-S-8520-1212 module (85/204 MHz D3.1)
  • ONX-720 IPX Package
  • Charger
  • Protective Fitted Case
  • Cat6A jumper M-F and M-M

Options & Accessories

Option Description
ONXF-SW-SFP-ETH Enable SFP+ port for Optical Ethernet testing over VIAVI supported SFP’s
ONXF-SW-OC-PON OneCheck PON – PON testing via GPON/XGSPON SFP+
ONXF-SW-OC-GPON-EMUL GPON Emulation for live service testing on GPON network
ONXF-SW-OC-XGSPON-EMUL GPON Emulation for live service testing on GPON network
ONX-SMART-ACCESS Smart Access Anywhere
ONXF-SW-OOKLA-SPD-5G-1Y ONX Ookla Speedtest to 5 Gbps 1 Yr Timed License/deployed via StrataSync
ONXF-SW-OOKLA-SPD-5G-3Y ONX Ookla Speedtest to 5 Gbps 3 Yr Timed License/deployed via StrataSync
ONXF-SW-OOKLA-SPD-5G-5Y ONX Ookla Speedtest to 5 Gbps 5 Yr Timed License/deployed via StrataSync
ONXF-SW-OOKLA-SPD-5G ONX Ookla Speedtest to 5 Gbps
ONXF-SW-OOKLA-SPD-10G-1Y ONX Ookla Speedtest to 10 Gbps 1 Yr Timed License/deployed via StrataSync
ONXF-SW-OOKLA-SPD-10G-3Y ONX Ookla Speedtest to 10 Gbps 3 Yr Timed License/deployed via StrataSync
ONXF-SW-OOKLA-SPD-10G-5Y ONX Ookla Speedtest to 10 Gbps 5 Yr Timed License/deployed via StrataSync
ONXF-SW-OOKLA-SPD-10G ONX Ookla Speedtest to 10 Gbps
ONXF-SW-TRUESPEED-5G-1Y ONX TrueSpeed to 5 Gbps 1 Yr Timed License/deployed via StrataSync
ONXF-SW-TRUESPEED-5G-3Y ONX TrueSpeed to 5 Gbps 3 Yr Timed License/deployed via StrataSync
ONXF-SW-TRUESPEED-5G ONX TrueSpeed to 5 Gbps permanent License
ONXF-SW-TRUESPEED-10G-1Y ONX TrueSpeed to 10 Gbps 1 Yr Timed License/deployed via StrataSync
ONXF-SW-TRUESPEED-10G-3Y ONX TrueSpeed to 10 Gbps 3 Yr Timed License/deployed via StrataSync
ONXF-SW-TRUESPEED-10G ONX TrueSpeed to 10 Gbps Permanent License
ONXF-SW-IPERF-5G-1Y ONX iPerf test to 5 Gbps 1 Yr Timed License/deployed via StrataSync
ONXF-SW-IPERF-5G-3Y ONX iPerf test to 5 Gbps 3 Yr Timed License/deployed via StrataSync
ONXF-SW-IPERF-5G ONX iPerf test to 5 Gbps Permanent License
ONXF-SW-IPERF-10G-1Y ONX iPerf test to 10 Gbps 1 Yr Timed License/deployed via StrataSync
ONXF-SW-IPERF-10G-3Y ONX iPerf test to 10 Gbps 3 Yr Timed License/deployed via StrataSync
ONXF-SW-IPERF-10G ONX iPerf test to 10 Gbps permanent License
ONX-CATV-SW-HL-LKG Home Leakage Software Option
ONX-CATV-SW-HOMETDR Home TDR Software Option
ONX-CATV-SW-RSG-LOOP Return Signal Generator with Loopback Option
ONX-CATV-SW-INGRESS-EXP Ingress Expert Option for ONX 720’s
ONX-CATV-SW-RP-SNR-OCE Return Path SNR in OneCheck Expert - OneExpert CATV
ONX-CATV-FWD-SWEEP Active Forward Sweep
ONX-CATV-REV-SWEEP Active Reverse Sweep
NSC-SFP-GPON GPON SFP for GPON emulation
NSC-SFP-XGSPON XGSPON SFP+ for XGSPON emulation
NSC-SFP-850-1G-10G Optical Ethernet SFP + 850 nm SR 1G and 10G
NSC-SFP-1310-1G-10G Optical Ethernet SFP + 1310 nm LR 1G and 10G
NSC-SFP-1550-1G-10G Optical Ethernet SFP + 1550 nm ER 1G and 10G
AC-CHARGER Replacement AC charger (no power cord)
AC-CAR-CHARGER Car Charger
CC-034601 Large Carrying Case
1019-00-1366 Strand Hook
ONXF-HANDSTRAP Handstrap for use on unit without a case
ONXF-HFC-BATT-96WHR Replacement 96 W/Hr Battery
ONXF-DISPLAY-PROTECTOR-5P Replacement screen protector (5 pack)
ONXF-ETH-ADAPT-M-F Ethernet Cat6a M-F adapter 0.5 m
NSC-ETHERNET-CABLE Ethernet Cat6a M-M Patch Cable
ONXF-HFC-CASE Fitted protective case for ONX-720/730 with DOCSIS 3.1

Documents & Resources