VIAVI CX200 SiteXpert Handheld Communications Service Monitor
Handheld communications service monitor for field and infrastructure testing of analog and digital land mobile radio systems up to 3 GHz.
- Display size
- 8 in (20.3 cm)
- Timebase accuracy
- 0.05 ppm
- Timebase aging
- ±0.5 ppm/year
- Warm-up time
- 30 minutes
Overview
The VIAVI CX200 SiteXpert is a handheld communications service monitor for field and infrastructure testing of land mobile radio (LMR) systems. It brings features from VIAVI's larger radio test sets into a field-portable package.
As the LMR market moves from analog to digital, the CX200 provides frequency, power and modulation analysis for both analog and digital systems. Supported technologies include AM/FM/PM/SSB, P25 Phase 1 and Phase 2 (including Linear Simulcast Modulation), TETRA, DMR, DMR Repeater and NXDN, with OneViewer post-analysis software.
Digital Radio Analysis
With the P25 and DMR options, the large display presents modulation analysis tools such as distribution plots, eye diagrams, constellation plots, trajectory plots (P25) and burst profile plots (DMR). Several plots can be viewed at the same time or a single plot expanded to full screen. The TETRA option supports testing of TETRA radios, mobile stations and base stations.
Automated Testing
The optional Auto-Test applications provide automated testing and alignment of land mobile radios with minimal user input.
Cable and Antenna Analysis
A standard 1-port vector network analyzer supports Distance to Fault, VSWR and Return Loss measurements. Calibrated measurements require the Short-Open-Load calibrator.
Key Features
- Analog AM/FM/PM/SSB test
- Tracking generator (standard)
- Cable and Antenna Analyzer (1-Port) (standard)
- Spectrum analyzer (standard)
- 1-port vector network analyzer for Distance to Fault, VSWR and Return Loss
- WiFi, Bluetooth and VNC (standard)
- Smart Access Anywhere and StrataSync (standard)
- Remote Command Interface (standard)
- 1 GHz standard frequency range, 3 GHz optional
- Optional P25 Phase 1 and P25 Phase 2 test, including Linear Simulcast Modulation
- Optional DMR and DMR Repeater test
- Optional TETRA test for mobile and base stations
- Optional NXDN test
- Optional Auto-Test applications for automated radio testing and alignment
- Optional Bird power meter support
- OneViewer post-analysis software
- 8 in display
Specifications
| Display size | 8 in (20.3 cm) |
|---|---|
| Timebase accuracy |
0.05 ppm
0°C to 50°C
|
| Timebase aging | ±0.5 ppm/year |
| Warm-up time | 30 minutes |
| External reference | 10 MHz |
| Frequency range |
1 MHz to 1 GHz
optional, functional to 100 kHz
|
|---|---|
|
Frequency range
CX200-F3GHz
|
1 GHz to 3 GHz |
| Frequency resolution | 1 Hz |
| RF Duplex Port output level range |
-135 dBm to -50 dBm
1 MHz to 3 GHz
|
| RF Output Port output level range |
-95 dBm to 0 dBm
1 MHz to 3 GHz
|
| Output level resolution | 0.1 dB |
| Output level accuracy | ±1.5 dB (1 MHz to 3 GHz) level >= -125 dBm; ±1.5 dB typical (level < -125 dBm) |
| Bandwidth | 100 MHz |
| VSWR, RF Duplex Port |
≤1.2
for frequency >1 MHz
|
| VSWR, RF Output Port |
≤1.6 typical
for frequency >1 MHz
|
| Phase noise |
-100 dBc/Hz at 10 kHz offset at 1000 MHz
Frequency ≥1 MHz and Level ≤0 dBm
|
| Harmonics |
≤35 dBc (-50 dBc typical)
Frequency ≥1 MHz and Level ≤0 dBm
|
| Non-harmonics |
≤-50 dBc
Frequency ≥1 MHz and Level ≤0 dBm
|
| Residual AM | <0.5% RMS in 300 Hz to 3 kHz BW |
| Residual FM | <15 Hz RMS in 300 Hz to 3 kHz BW; <6 Hz RMS, Typical <800 MHz |
| Modes | AM, FM, PM, SSB |
|---|---|
| Modulation frequency range | 20 Hz to 20 kHz |
| Distortion |
3%
1000 Hz rate, >2 kHz Deviation, 300 Hz - 3 kHz BP filter
|
| AM range | 0% to 100% |
| AM accuracy (internal source) | ≤±5% of settings |
| FM range | 0 Hz to 100 kHz |
| FM accuracy (internal source) | ≤±2.5% of setting |
| PM range | 0 rad to 6.3 rad |
| PM accuracy |
<±2.5% of setting
with frequency response of ±0.5 dB 20 Hz to 10 kHz
|
| SSB modulation frequency | 30 Hz to 20 kHz |
| SSB carrier suppression | >70 dB |
| SSB sideband suppression | >60 dB |
| Internal modulation sources | 3 |
| Source waveforms | Sine, Square, Triangle, Ramp, DTMF, DCS, CTCSS, Tone Remote, Tone Sequential, Two-Tone Sequential |
| CTCSS tone | Tone 1 (67) to Tone 50 (254.1) Hz |
| Frequency range |
1 MHz to 1 GHz
optional, functional to 100 kHz
|
|---|---|
|
Frequency range
CX200-F3GHz
|
1 GHz to 3 GHz |
| RF Input Port maximum input level | +21 dBm (125 mW) max preamp and frequency ≥1 MHz; +14 dBm (25 mW) max preamp and frequency <1 MHz |
| RF Duplex Port maximum input level |
+47 dBm (50 Watts) continuous, <35°C; +51 dBm (125 Watts) Cyclical
Cyclical: Max ON of 30 sec and Min OFF for 90 sec for power levels >50 Watts
|
| Absolute max power |
150 W
Alarm sounds (no auto shutdown)
|
| VSWR, RF Duplex Port | ≤1.2 (100 kHz to 1 GHz) |
| VSWR, RF Input Port |
≤1.7 (1 MHz to 3 GHz)
with 10 dB input attenuation
|
| 2nd harmonic | <-30 dBc |
| 3rd harmonic | <-45 dBc, <-60 dBc (typical) |
| Spurious response, input related | ≤-42 dBc, -60 dBc (typical) |
| Spurious response, non-input related | ≤-95 dBm (typical) |
| Phase noise | -95 dBc/Hz at 10 kHz |
| Dynamic range | >105 dB |
| TOI |
>+42 dBm
max gain
|
| DANL |
<-163 dBm/Hz
at max gain
|
| Analog sensitivity |
<-100 dBm
10 dB SINAD or better with 100 kHz Bandwidth filter
|
| Bandwidth | 100 MHz (wideband), 8 MHz (narrowband) |
| RF bandpass filters (IF filters) | 5 kHz, 6.25 kHz, 8.33 kHz, 10 kHz, 12.5 kHz, 25 kHz, 30 kHz, 100 kHz, 300 kHz |
| Frequency range | 1 MHz to 1 GHz (Standard) |
|---|---|
|
Frequency range
CX200-F3GHz
|
1 GHz to 3 GHz |
| Measurement modes | RMS, average RMS, minimum, maximum |
| Level, RF Duplex Port | -67 dBm to +47 dBm |
| Level, RF Input Port | -108 dBm to +10 dBm |
| Accuracy, RF Duplex Port |
±0.4 dB (1 MHz to 1 GHz); ±0.6 dB elsewhere
Accuracy after normalizing at the measurement frequency
|
| Accuracy, RF Input Port |
±0.6 dB (1 MHz to 1 GHz), ±0.9 dB elsewhere
Accuracy after normalizing at the measurement frequency
|
| Frequency range | 1 MHz to 3 GHz |
|---|---|
| Resolution | 1 Hz |
| Accuracy | Same as timebase |
| FM modes | RMS, +Pk, -Pk, ±Pk/2 |
|---|---|
| FM deviation | 0 Hz to 75 kHz |
| FM accuracy | ±1.0% for rate ≥1.5 kHz and ≤3 kHz; ±2.0% otherwise |
| Residual FM | ≤3 Hz (300 Hz to 3 kHz) and frequency <1 GHz |
| AM measurement range | 0% to 100% |
| AM accuracy | ±1 % for depth ≥30% and ≤90% at 1 kHz rate; ±2% otherwise |
| AF frequency range | 10 Hz to 20 kHz |
| PM range | 0 radians to 6.3 radians |
| PM accuracy | ±2.0%, ±1.0% (rate 1.5 kHz to 3 kHz) |
| SSB modes | SSB-USB, SSB-LSB |
| Distortion meter frequency range | 50 Hz to 10 kHz |
|---|---|
| SINAD meter measurement range | 0 dB to 60 dB |
| SINAD meter accuracy | <±1 dB @12 dB SINAD |
| S/N meter accuracy | ≤1 dB |
| AF tones analyzer modes | DTMF, DCS, CTCSS, Two-Tone, Tone Sequential, Tone Remote |
| Audio level meter input impedance | 100 K Ω, 600 Ω, 300 Ω |
| Audio analyzer frequency range | DC to 100 kHz |
| Audio filters, lowpass | 300 Hz, 3 kHz, 3.4 kHz, 5 kHz, 15 kHz, 20 kHz, 40 kHz, TIA 3 kHz, TIA 15 kHz |
| Audio filters, highpass | 50 Hz, 300 Hz, TIA 50 Hz, TIA 300 Hz |
| Audio filters, other | C-MSG, CCITT |
| Span | 2 kHz to 8 MHz |
|---|---|
| IF bandwidth | 10 MHz |
| RBW | 1 Hz to 50 kHz |
| Detector | Normal, positive peak, negative peak, average (RMS) |
| FFT windows | Flat top, Rectangular, Hamming, Hanning, Blackman-Harris |
| Frequency range | 1 MHz to 1 GHz (Standard) |
|---|---|
|
Frequency range
CX200-F3GHz
|
1 GHz to 3 GHz |
| RBW range | 25 Hz to 6 MHz |
| VBW range | 5 Hz to 6 MHz |
| Sweep time range | 0.4 ms to 1000 s |
| Spurious free dynamic range | ≥80 dB |
| DANL |
<-162 dBm/Hz
max gain
|
| Trigger | Free run, External |
| Output ports | RF Output Port, RF Duplex Port |
|---|---|
| Level range and accuracy | Same as RF Generator |
| Frequency range | 0 Hz to 100 kHz |
|---|---|
| Level range | 0 Vpk to ±8 Vpk into 600 Ω |
| Level accuracy |
±2%
level >=200 mV and frequency from 20 Hz to 20 kHz
|
| THD+N |
<-75 dB
for frequency 1 kHz and level 1 Vrms
|
| Max output current | 100 mA |
| Sweep per div | 1 µs to 100 ms/div |
|---|---|
| Vertical range | 1 mV/div to 20 V/div |
| Bandwidth | 20 kHz |
| Input range | 20 mV to 30 Vrms (42.4 Vpk) |
| Coupling | AC, DC |
| Modes |
P25, P25 Phase 2, TETRA, DMR, NXDN
Optional
|
|---|---|
|
P25 modulation fidelity accuracy
P25
|
<5% of reading (2.5% to 12%) |
|
P25 symbol deviation accuracy
P25
|
±1% |
|
TETRA modulation type
TETRA
|
π/4 DQPSK, 18 ksymbols/sec, TETRA filter (RRC with <0.35) |
|
TETRA modulation accuracy
TETRA
|
<3% RMS, <6% peak |
|
DMR FSK error range
DMR
|
0 to 20% |
|
DMR symbol deviation range
DMR
|
1500 Hz to 2350 Hz |
|
DMR protocol decode
DMR
|
Color Code, Call ID, Unit ID |
| Frequency range | 1 MHz to 3 GHz |
|---|---|
| Test port power (Port 1) | 0 dBm |
| Dynamic range | 90 dB |
| Parameters | S11 |
| Measurements | Magnitude, VSWR, Distance to Fault, Cable Loss, Insertion Loss |
| Calibration method | Short-Open-Load, Thru |
| Maximum distance | 1000 ft (305 m) |
| Weight | 8.6 lbs (3.9 kg) |
|---|---|
| Temperature, operating | 0°C to 50°C |
| Temperature, not operating |
-40°C to 71°C
Battery must not be subjected to temperatures below -20°C, nor above 60°C
|
| Relative humidity | 95% RH (non-condensing) |
| Altitude | 4600 m |
| Vibration, shock, bench handling, transit drop | MIL-PRF-28800F Class 3 |
| Type | Lithium Ion, 14.4 V, 6.8 Ah |
|---|---|
| Operating time | 1.5 hours (typical), 3.75 hours (optional) |
| Battery charging limits | 0°C to 45°C (32°F to 113°F) ≤85% RH |
| EMC | IEC 61000-3-2:2018; 6100-3-3:2013 +A1:2017; CISPR 11:2015 +A1:2016 +A2:2019 |
|---|---|
| Safety | EN IEC 61326-1:2021 Class A |
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- Land mobile radio field testing
- Mission-critical radio infrastructure testing
- Base station and repeater maintenance
- Subscriber radio testing and alignment
- Analog to digital LMR migration
- Cable and antenna line sweeping
Options & Accessories
| Option | Description |
|---|---|
| CX200-F3GHz | 3 GHz frequency range — Extends RF generator, receiver, power meter and spectrum analyzer coverage to 1 GHz to 3 GHz |