VIAVI CX100 ComXpert handheld communications service monitor, right side view
CX100

CX100 ComXpert Handheld Communications Service Monitor

Rugged handheld communications service monitor with a 6 GHz frequency range and a 1-port vector network analyzer for field radio testing.

Weight
11 lbs (5 kg)
Dimensions
12 in x 9.5 in x 4.3 in (30.5 cm x 24.1 cm x 10.9 cm)
Display size
5 in (12.7 cm), diagonal
Datasheet

Overview

The VIAVI CX100 ComXpert is a rugged, handheld analog communications service monitor built for tactical field use in harsh environments. It combines a full-color user interface with a compact form factor intended for field maintenance of radios and networks.

The instrument covers a 1 MHz to 6 GHz frequency range and integrates an RF generator, RF receiver, power meter, frequency counter, spectrum analyzer, audio and demodulation meters, an AF generator and a two-trace oscilloscope. A digital modulation vector signal analyzer supports PSK and QAM formats with EVM, MER and constellation measurements.

A built-in 1-port vector network analyzer provides cable and antenna analysis, with S11 measurements in the frequency and distance domains and Short-Open-Load calibration.

Connectivity

Wireless Personal Area Network (WPAN/BT) and Wi-Fi connectivity options are available, and the CX100 can be operated remotely with the VIAVI Mobile Tech app.

Key Features

  • Handheld form factor
  • Rugged design for tactical field use
  • 6 GHz frequency range
  • 1 port Vector Network Analyzer for cable and antenna analysis
  • Full-color user interface
  • Wireless Personal Area Network (WPAN/BT) and Wi-Fi connectivity options
  • VIAVI Mobile Tech application for remote use

Specifications

General
Weight 11 lbs (5 kg)
Dimensions 12 in x 9.5 in x 4.3 in (30.5 cm x 24.1 cm x 10.9 cm)
Display size 5 in (12.7 cm), diagonal
Timebase
Frequency drift 0.05 ppm (-10 to 40ºC)
temperature variation <2°C/min, typical
Aging 0.5 ppm/year
after first year
Warm-up time 3 minutes: within ±0.1 ppm at 25°C
typical
RF Generator
Frequency range 1 MHz to 6 GHz
Frequency resolution 1 Hz
Frequency accuracy Same as timebase
Level range, T/R Duplex port -120 dBm to -30 dBm (CW)
Level range, ANT/SWR port -100 dBm to 0 dBm CW
Level resolution 0.1 dB
Level accuracy, T/R Duplex port ±2.0 dB for level >-100 dBm, ±3.0 dB for level <-100 dBm
Level accuracy, ANT/SWR port ±2.0 dB
VSG bandwidth 8 MHz
for IQ playback
VSWR, T/R Duplex port <1.4 (1 MHz to 6 GHz)
Phase noise <-105 dBc/Hz at 10 kHz offset, RF < 900 MHz; <-90 dBc/Hz at 10 kHz offset, RF ≥ 900 MHz
Harmonics -30 dBc
Non-harmonics -60 dBc
typical, output level >-50 dBm
Residual AM <0.20% RMS
post detection BW 15 kHz
Residual FM <20 Hz RMS
post detection BW 3 kHz
Analog Modulation (Generator)
Modulation modes AM, FM
AM range 0.1% to 100%
AM resolution 0.10%
AM accuracy (internal source) <±3% of setting from 10% to 90%
20 Hz to 10 kHz rate
FM range 0 to 100 kHz
FM resolution 0.1 Hz
FM accuracy (internal source) <±3% of setting
from 1 kHz to 100 kHz deviation, 20 Hz to 15 kHz rate
Internal modulation sources 2
Source waveforms Sine
Sine wave range 0 to 100 kHz
RF Receiver
Frequency range 1 MHz to 6 GHz
Maximum input power, ANT/SWR port +10 dBm
de-rated below 50 MHz
Maximum input power, T/R Duplex port +43 dBm
Duty-cycled
VSWR, T/R Duplex port <1.4 (1 MHz to 6 GHz)
2nd harmonic response <-30 dB
3rd harmonic response <-50 dB
Spurious response, 1 MHz to 1 GHz <-45 dB
exceptions may apply
Spurious response, 1 GHz to 6 GHz <-55 dB
exceptions may apply
Phase noise <-105 dBc/Hz at 10 kHz offset, RF < 900 MHz; <-90 dBc/Hz at 10 kHz offset, RF ≥ 900 MHz
Dynamic range at 900 MHz 110 dB (0 dB attenuation), 107 dB (preamp)
2/3 * (TOI-DANL)
Dynamic range at 1000 MHz 107 dB (0 dB attenuation), 106 dB (preamp)
2/3 * (TOI-DANL)
TOI >+19 dBm (0 dB attenuation), >-1 dB (preamp)
DANL at 900 MHz <-144 dBm (0 dB attenuation), <-162 dBm (preamp)
DANL at 1000 MHz <-138 dBm (0 dB attenuation), <-158 dBm (preamp)
Analog sensitivity 10 dB SINAD for -100 dBm input level
RF bandpass filters (IF filters) 5 kHz, 6.25 kHz, 8.33 kHz, 10 kHz, 12.5 kHz, 25 kHz, 30 kHz, 100 kHz, 300 kHz
Power Meter
Frequency range 1 MHz to 6 GHz
Level range Up to 43 dBm into T/R Duplex Port, (20 mW to 20 W)
Resolution 1% of full scale or 1 mW
Accuracy, T/R Duplex port ±10%
RF Frequency Counter / RF Frequency Meter
Frequency range 1 MHz to 6 GHz
Resolution 1 Hz
Accuracy Frequency Reference
Input level range, T/R Duplex port -50 dBm to 43 dBm
Input level range, ANT/SWR port -80 dBm to +10 dBm (-80 dBm to -20 dBm w/pre-amp and over-the-air)
Analog Modulation Measurements
FM measurement range 0 to 100 kHz
FM accuracy ±2%; ±1.0% from 1.5 kHz to 3 kHz at 1 kHz rate
FM distortion <1%, 1 kHz to 5 kHz deviation (50 Hz to 3 kHz rate); <0.5%, 1.5 kHz to 3 kHz deviation (1 kHz rate)
Residual FM <5 Hz rms (300 to 3000 Hz)
FM AF frequency range 10 Hz to 20 kHz
AM measurement range 0 to 100%
AM accuracy <1%
AM frequency response ±0.1 dB 50 Hz to 6 kHz; ±0.05 dB 50 Hz to 6 kHz rate for Subscriber testing
AM distortion <1%, 1 to 5 kHz deviation (50 Hz to 3 kHz rate); <0.5%, 1.5 to 3 kHz deviation (1 kHz rate)
AM AF frequency range 10 Hz to 20 kHz
Residual AM <0.1% (30 MHz to 3 GHz)
Audio and Demodulation Meters
Distortion meter frequency range DC to 100 kHz (audio in)
Limited by IF bandwidth (demodulation)
Distortion meter measurement range 0 to 100%
Distortion meter accuracy <3% of reading +0.1% distortion, 1% to 20%
SINAD meter frequency range DC to 100 kHz (audio in)
Limited by IF bandwidth (demodulation)
SINAD meter measurement range 0 to 63 dB
SINAD meter accuracy <1 dB at 12 dB SINAD
S/N meter frequency range DC to 100 kHz (audio in)
Limited by IF bandwidth (demodulation)
S/N meter measurement range 0 to 63 dB
S/N meter accuracy <1 dB
AF counter frequency range DC to 100 kHz (audio in)
Limited by IF bandwidth (demodulation)
AF counter accuracy Timebase +0.1 Hz
Audio Analyzer
Frequency range DC to 100 kHz (audio in)
Limited by IF bandwidth (demodulation)
FFT windows Blackman-Harris
Level range 2 mV to 20 Vpk
DC accuracy ±1% of reading (>200 mV), ±2 mV (<200 mV)
AC accuracy ±2% of reading (200 mV to 2 V, 20 Hz to 20 kHz), ±5% (200 mV to 20 V, 20 Hz to 100 kHz)
typical
THD+Noise <80 dB (20 Hz to 20 kHz)
Lowpass filters 300 Hz, 3 kHz, 3.4 kHz, 5 kHz, 15 kHz, 20 kHz
Highpass filters 20 Hz, 50 Hz, 300 Hz
Other filters C-MSG, CCITT
Spectrum Analyzer
Frequency range 1 MHz to 6 GHz
Span range 1 kHz/Div, full span and zero span
Span accuracy ±5% of span width
Vertical scale 10 dB/div and 2 dB/div; All available ranges in dB/div: 1, 2, 5, 10, 20
Vertical range 80 dB
RBW range 100 Hz to 5 MHz
VBW range 100 Hz to 5 MHz
Sweep time range 1 μs to 100 s
Detector Normal, positive peak, negative peak, sample, Average (RMS)
Digital Modulation (Vector Signal Analyzer)
Modulation types BPSK, QPSK, 8-PSK, 16-PSK, 4-QAM, 16-QAM, 64-QAM
Symbol rate ≤ 3.75MSymbol/s
Oversampling ≥ 4
Product of Symbol rate and oversampling ≤ 15Msample/s
Number of symbols ≤ 16,000
Reference filter Raised Cosine, Square Root Raised Cosine; Roll-off Factor < 1; Filter Length 4-30
Measurement filter Raised Cosine, Square Root Raised Cosine; Roll-off Factor < 1; Filter Length 8-40
Measurement input level range, T/R Duplex port -50 dBm to 43 dBm
Measurement input level range, ANT/SWR port -80 dBm to +10 dBm (-80 dBm to -20 dBm w/pre-amp and over-the-air)
Measurements Signal Power, EVM, Frequency Error, MER, Symbol Error Rate, IQ Offset, Gain Imbalance, IQ Imbalance, rho
EVM residual 2% typical for QPSK 10MHz BW @ 1GHz
input level -50dBm ANT/SWR Port, Preamp Enabled
Graphical display Constellation plot
AF Generator
Output impedance <4 Ω
Max output current 20 mA
Frequency range DC to 100 kHz (±0.5 dB), 20 Hz to 20 kHz (±0.1 dB)
Frequency resolution 0.1 Hz
Frequency accuracy Timebase +0.5 Hz
Level range 0 to ±8 Vpk into 600 Ω, 4 Vpk into 50 Ω
DC accuracy ±1% (>200 mV), ±2 mV (<200 mV)
AC accuracy ±2% (>200 mV, 20 Hz to 20 kHz), ±5% (>2 mV, 20 Hz to 100 kHz)
typical
THD+N <80 dB (20 Hz to 20 kHz)
Oscilloscope
Traces 2
Markers 2
Sweep per div 20 µs to 1 s/div
Bandwidth 100 kHz
Audio Input
Input accuracy <5%
Trigger modes Single, Normal, Automatic, Free run
Vector Network Analyzer
Frequency range 1 MHz to 6 GHz
Frequency resolution 0.1 Hz
Frequency accuracy Same as timebase
Test port power +5 dBm
Dynamic range 90 dB
Measurement parameters S11
Graph type Log Magnitude (dB), SWR (Linear)
Domains Frequency, Distance
Calibration type Full S11
Calibration method Short-Open-Load
Corrected source match >40 dB (<900 MHz) (95th percentile) max 35 dB; >30 dB (≥900 MHz) (80th percentile) max 20 dB
Corrected reflection tracking ±0.5 dB
typical
Maximum distance (distance domain) 100 m (328 ft) or 40 dB Return Loss whichever comes first for a 6 GHz span
Distance domain measurement display Return Loss, VSWR
Distance domain measurement format dB, VSWR
Environmental/Physical
Temperature, not operating -20°C to +60°C
Temperature, operating -10°C to +40°C
Relative humidity 95% RH (noncondensing)
Altitude 4600 m
Vibration MIL-PRF-28800F Class 2
Shock, functional MIL-PRF-28800F Class 2
Bench handling MIL-PRF-28800F Class 2
Transit drop MIL-PRF-28800F Class 2
Battery
Type Lithium Ion, 14.4 V, 6.8 Ah
Operating time 3+ hours
Charging limits 0°C to 45°C (32°F to 113°F) <85% RH

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • Tactical radio field testing
  • Land mobile radio testing
  • Cable and antenna analysis
  • Field maintenance of radio networks

Documents & Resources