VIAVI Trilithic DSP Series meters including the 360 DSP installation and service meter
VIAVI / DSP Series / Installation and Service Meters
360 DSP D3.0

VIAVI Trilithic 360 DSP D3.0 DOCSIS 3.0 Installation and Service Meter

DOCSIS 3.0 installation and service meter with built-in cable modem, Ethernet and WiFi, plus forward and return spectrum analysis to 1250 MHz.

Description
DOCSIS 3.0 Installation and Service Meter
Part Number
TRI-DSP-360-D30-BASE
Datasheet

Overview

The VIAVI Trilithic 360 DSP D3.0 is the DOCSIS 3.0 version of the 360 DSP installation and service meter (part number TRI-DSP-360-D30-BASE), part of the DSP Series of compact meters for cable service providers and contractors. The 180 and 360 DSP meters are aimed at fast RF installation testing and troubleshooting, with analog and digital signal measurements for verifying installation quality.

The meter uses a color touchscreen interface with pass/fail indicators and autotest apps that combine multiple tests to standardize installation procedures, including triple-play tests and home certification. Analog and QAM carrier levels, constellation, equalizer taps, MER and BER can be measured on 64 and 256 QAM downstream channels, and the channel plan scan shows the frequency response of the full channel lineup with adjustable markers for tilt measurement. Return spectrum from 4 to 205 MHz and forward spectrum from 5 to 1250 MHz can be displayed.

Connectivity

The 360 DSP adds a built-in cable modem, Ethernet and WiFi communications. The internal modem is used for network connectivity and performance testing, cable modem statistics, and ping, traceroute, throughput, VoIP and modem speed tests. The WiFi survey mode shows live signal strengths, SSID, channel and power level of nearby networks.

StrataSync

Test results can be synced to StrataSync, the VIAVI cloud-based asset, configuration and test-data management system, over Ethernet, DOCSIS or WiFi. With the StrataSync workflow option, work orders and test profiles can be deployed to the meter and the results uploaded against each work order.

The meter also has a built-in LED flashlight, a glow-in-the-dark keypad and a quick charge time.

Key Features

  • DOCSIS 3.0 version of the 360 DSP installation and service meter
  • Built-in cable modem, Ethernet and WiFi communications
  • Internal modem operating in DOCSIS 3.0 (32x8) mode
  • Measures up to eight upstream and up to 32 downstream SC-QAM channels in a DOCSIS 3.0 environment
  • Analog channel measurements: video/audio level, delta V/A, carrier-to-noise and hum
  • Digital QAM measurements: level, pre/post BER, MER, constellation, equalizer, BER vs time, errored seconds
  • Deep interleave compatible QAM measurements
  • Channel plan scan, tilt measurement and channel plan auto discovery
  • Return spectrum analysis from 4 to 205 MHz
  • Forward spectrum analysis from 5 to 1250 MHz
  • Network test suite with ping, traceroute, throughput, VoIP and modem speed test
  • WiFi survey with built-in 802.11 b/g/n 2.4/5 GHz adapter
  • Color touchscreen interface with simple pass/fail indicators and autotest apps
  • Remote access and control of the meter over any active network connection
  • Multi-user profiles, multi-language support and on-meter job management
  • Test result syncing to StrataSync over Ethernet, DOCSIS or WiFi
  • Built-in LED flashlight and glow-in-the-dark keypad
  • Firmware updates via the web or USB

Specifications

Ordering Information
Description DOCSIS 3.0 Installation and Service Meter
Part Number TRI-DSP-360-D30-BASE
Level Measurement
Channel Bandwidth 6 MHz and 8 MHz
Amplitude Range -40 dBmV to +50 dBmV
Modulation Types (Analog) NTSC, PAL B/D/G/H/I/K/N and SECAM B/D/G/H/I/K
Modulation Types (Digital) 16/32/64/128/256 QAM Annex A, 64/256 QAM Annex B/C
OFDM 4K/8K is listed for DOCSIS 3.1 option equipped meters only
Analog Measurement Accuracy ±0.75 dB @ 77° F (25° C); ±2.0 dB from 0° to +50° C (32° to 122° F)
Digital Measurement Accuracy ±0.75 dB @ 77° F (25° C); ±2.5 dB from 0° to +50° C (32° to 122° F)
Display Resolution 0.1 dB
Spectrum Measurement
Frequency Range Return Path: 4 to 205 MHz; Forward Path: 5 to 1250 MHz
Dual Return Path Diplexers 42 MHz: 4 to 42 MHz; 85 MHz: 4 to 85 MHz
Manually Adjustable Resolution Bandwidth Return Path: 300 kHz; Forward Path: 10, 30, 100, and 300 kHz; 1 and 3 MHz
Auto Ranging Resolution Bandwidth 10 kHz: Span ≤ 3.5 MHz; 30 kHz: Span ≤ 12.0 MHz; 100 kHz: Span ≤ 35.9 MHz; 300 kHz: Span ≤ 300 MHz; 1 MHz: Span ≤ 359.2 MHz; 3 MHz: Span ≥ 359.3 MHz
Display Spans Return Path: 4 to 42 MHz, 4 to 65 MHz, 4 to 85 MHz or 4 to 205 MHz; Forward Path: User-selectable in 1 kHz steps
Display Scale 1, 2, 5, 7.5 or 10 dB/division
Display Range 8 vertical divisions
when marker bar is hidden
Spurious Free Dynamic Range 60 dB @ 25° C (77° F) (+50 dBmV)
Sensitivity (terminated) Return Path: -40 dBmV (4 to 205 MHz); Forward Path: -40 dBmV (5 to 1250 MHz)
Digital Channel Measurement
Deep Interleave Compatibility Yes
Downstream MER 40 ±2 dB @ +6 dBmV RF Input Level; 34 ±2 dB @ -6 dBmV RF Input Level
Downstream BER Method True BER, derived from code words not from MER
Downstream BER Standard ITU J.83 annex A, B, C
Downstream BER Range 1 E-7 to 1 E-9 @ -6 dBmV RF Input Level
Symbol Rates ≥ 2 MSPS; ≤ 6.952 MSPS
Cable Modem Measurement
Protocol Support DOCSIS 1.1 / 2.0 / 3.0 / 3.1*
* DOCSIS 3.1 option equipped meters only; the D3.0 model is the DOCSIS 3.0 version
SNMP V1, V2c, V3
Compliance Certificates FCC
CM Diplexer 85 MHz: 5 to 85 MHz
Receiver Frequency (edge to edge) 108 to 1218 MHz
Receiver Channel Bandwidth 6 MHz
Receiver Signal Level -15 to 15 dBmV
DOCSIS 3.0 Demodulation 64 QAM, 256 QAM
DOCSIS 3.0 Downstream Data Rate Up to 1.2 Gbps with 32 downstream channel bonding (DOCSIS 32x8)
Transmitter Frequency (edge to edge) 5 to 85 MHz
Transmitter Signal Level Controlled by CMTS though power ranging function
DOCSIS 3.0 Modulation QPSK, 8 QAM, 16 QAM, 32 QAM, 64 QAM, and 128 QAM (SCDMA only)
DOCSIS 3.0 Upstream Data Rate Up to 320 Mbps with 8 upstream channels bonding
Carrier-to-Noise Measurement
Minimum Input Level for Full Range +10 dBmV
In-service, non-scrambled standard channels only
Dynamic Range 50 dB
Resolution < 0.5 dB
Tilt Measurement
Max Number of Carriers 14
dependent on favorite channel setup
High/Low Delta Resolution 0.1 dB
Scan Video, audio, pilot, and digital carriers
Analog and Digital Hum
Minimum Input Level 0 dBmV
In-service, non-scrambled standard channels only
Range 0 to 5%
Resolution 0.10%
Accuracy ±0.5%
Physical
Construction Rubber overmolded plastic housing
Control Glow in the dark keypad and LCD touchscreen and/or via a wireless connection to a mobile device such as a laptop, tablet, iPad® or iPhone®, or Android® handset
Display Color LCD touchscreen, 480 x 272 pixels (approx 4” x 2.25”)
Listed for 180/360 models
Annunciators Audible annunciator for key strokes
Antenna Internal WiFi antenna, 2 dB gain
Flashlight High-intensity LED (0.25W)
Dimensions w/o Case (H x W x D) 8.6 x 6.1 x 2.00 in (21.84 x 15.94 x 5.08 cm)
Dimensions w/ Case (H x W x D) 9.6 x 7.1 x 3.00 in (24.38 x 18.03 x 7.62 cm)
Weight w/o Case 2.9 lbs (1.32 Kg)
Listed for 360 DSP
Weight w/ Case 3.9 lbs (1.79 Kg)
Listed for 360 DSP
Interfaces
Tx/Rx Test Port 75 Ohm Replaceable F-Type Connector
Upstream and Downstream RF Measurements
Ethernet RJ45 Management Port (10/100 Mbps)
WiFi 802.11 b/g/n 2.4/5 GHz WiFi Adapter
360 & 1G only
USB USB 2.0 Type-A Standard Port
Battery and Power
Operating Time 8 to 10 hours, dependent on use
Listed for 360 DSP
Charge Time 4 hours
Battery Two 2600 mAh @ 7.4V Li-Ion internal batteries, factory replaceable
Power Adapter Input 100 to 240 VAC ~ 50 to 60 Hz, 1.2A Max
Power Adapter Output 15 VDC, 3.34A
Environmental
Storage -18° to +50° C (0° to 122° F)
Operating Temperature 0° to +50° C (32° to 122° F)

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • Cable subscriber installation and service
  • Return spectrum analysis
  • Level, C/N and QAM measurement
  • Channel plan scan with tilt measurement
  • Cable modem service and network connectivity testing
  • Home WiFi survey
  • Home leakage testing (optional)
  • Contractor workflow and test-result compliance with StrataSync

Options & Accessories

Option Description
TRI-DSP-360-D30-ADV 360 DSP D3.0 Advanced — Adds FDR and Source Generator
TRI-DSP-360-D30-PRO 360 DSP D3.0 Pro — Adds Upstream Traffic Control Plus, Upstream Linear Distortion Measurements, and QAM Error Vector Spectrum Analysis
TRI-LKG-HL-METER-KIT Home Leakage Test Kit — Seeker Home Leakage Companion Kit: Seeker HL Source Transmitter, Dual-Band Antenna, Near-Field Probe and Case
TRI-DSP-SW-HL-LKG-OPT DSP Meter Leakage Software Option
TRI-ACCY-RF-TEST-CBL I/O-15 Precision test cable
TRI-ISTOP-1000MHZ I-Stop 1 GHz Test Probe — Ingress troubleshooting probe
TRI-ISTOP-1250MHZ I-Stop Test Probe — Ingress troubleshooting probe
TRI-TLB-46-LPF TLB-46 Return measurement low-pass filter
MP-80A MP-80A USB Optical Power Meter
FBP-P5000i P5000i USB Fiber Scope
TRI-DSP-360-CASE-REPL Replacement fitted case
TRI-DSP-STRAP-REPL Replacement shoulder strap
TRI-DSP-PWR-ADPT-NEW Replacement charger (no power cord)

Documents & Resources