VIAVI Trilithic DSP Series meters including the 1G DSP plant maintenance meter
1G DSP with OPM/VFL Sweepless

VIAVI Trilithic 1G DSP with OPM/VFL Sweepless Plant Maintenance Meter

DOCSIS 3.1 plant maintenance meter with Sweepless Sweep, a built-in optical power meter and a visual fault locator.

Part Number
TRI-DSP-1G-D31-VFL-SWPLS
Description
Plant Maintenance Meter with Sweepless Sweep, optical power meter and visual fault locator
Datasheet

Overview

The VIAVI Trilithic 1G DSP with OPM/VFL Sweepless (part number TRI-DSP-1G-D31-VFL-SWPLS) is a plant maintenance meter in the DSP Series. It combines CATV measurements, a DOCSIS 3.1 cable modem, Gigabit Ethernet testing and optical testing in one instrument, with Sweepless Sweep functions, a built-in optical power meter (OPM) and a visual fault locator (VFL).

The 1G DSP performs throughput testing at speeds of up to a gigabit per second through a dedicated Ethernet test port or the internal cable modem. It supports roundtrip or one-way Key Parameter Index (KPI) measurements with constant payload testing for Layer 2 through Layer 4, for verification of Ethernet Service Level Agreement (SLA) and Quality of Service (QoS) metrics.

Sweepless Sweep

The Sweepless model includes Cable Modem Sweep, which uses the meter's built-in cable modem to perform in-band return sweeps within the modem carriers. The meter injects up to eight upstream modem carriers and uses the pre-equalized data from the CMTS to plot the upstream frequency response, without dedicated headend sweep gear; it works with any DOCSIS 3.0 or DOCSIS 3.1 compatible CMTS with pre-EQ enabled. On DOCSIS 3.1 equipped meters, Cable Modem Sweep with OFDMA tests the entire return band. Forward Passive Sweep uses the live carriers in the HFC distribution system to test and set the tilt and gain of distribution amplifiers.

Optical Power Meter and VFL

The optical hardware package adds a built-in FTTx-ready optical power meter for absolute and relative measurements at 1310 nm, 1490 nm and 1550 nm, with interchangeable FC, SC and ST style adapters. It also adds a 650 nm visual fault locator for finding loss points in patch cords, patch panels and enclosures.

Operation

The meter has an 800 x 480 pixel color touchscreen, pass/fail indicators and autotest apps. It also offers remote control through a web browser, a glow-in-the-dark keypad and support for up to five user profiles. Test results and instrument configurations can be synchronized with VIAVI StrataSync over Ethernet, DOCSIS or WiFi.

Key Features

  • Combines CATV, DOCSIS 3.1 cable modem, Gigabit Ethernet and optical testing in one meter
  • Cable Modem Sweep (Sweepless) for in-band return sweeps using the internal cable modem
  • Cable Modem Sweep with OFDMA testing the entire return band, including close to the diplexer
  • Forward Passive Sweep using live HFC carriers, with no dedicated headend gear
  • Built-in optical power meter for 1310 nm, 1490 nm and 1550 nm with FC/SC/ST adapters
  • Visual fault locator for locating loss points in patch cords, patch panels and enclosures
  • Throughput testing up to 1 GbE through a dedicated test port or the internal cable modem
  • Roundtrip or one-way constant payload testing for Layer 2-4 Ethernet SLA and QoS verification
  • SFP optical power measurement with link speed, wavelength, Tx and Rx power
  • Internal DOCSIS 3.1 modem operating in DOCSIS 3.0 (32x8) and DOCSIS 3.1 modes
  • Dual RF test ports with source generator for RF loopback testing
  • Frequency domain reflectometer for distance to cable faults
  • Upstream Traffic Control Plus, upstream linear distortion and QAM Error Vector Spectrum measurements
  • Return spectrum 4 to 205 MHz and forward spectrum 5 to 1250 MHz
  • DOCSIS 3.1 OFDM channel measurements including PLC constellation, MER and decoder stress
  • Channel plan scan with tilt measurement and channel plan auto discovery
  • Built-in 802.11 b/g/n 2.4/5 GHz WiFi adapter with survey mode
  • Remote meter control via a web browser
  • Multi-user support for up to 5 technicians
  • Glow in the dark keypad and high-resolution color touchscreen
  • StrataSync integration over Ethernet, DOCSIS or WiFi

Specifications

Ordering
Part Number TRI-DSP-1G-D31-VFL-SWPLS
Description Plant Maintenance Meter with Sweepless Sweep, optical power meter and visual fault locator
Level Measurement
Channel Bandwidth 6 MHz and 8 MHz
Amplitude Range -40 dBmV to +50 dBmV
Modulation Types (Analog) NTSC, PAL B/D/G/H/I/K/N and SECAM B/D/G/H/I/K
Modulation Types (Digital) 16/32/64/128/256 QAM Annex A, 64/256 QAM Annex B/C, OFDM 4K/8K
OFDM: DOCSIS 3.1 option equipped meters only
Analog Measurement Accuracy ±0.75 dB @ 77° F (25° C); ±2.0 dB from 0° to +50° C (32° to 122° F)
Digital Measurement Accuracy ±0.75 dB @ 77° F (25° C); ±2.5 dB from 0° to +50° C (32° to 122° F)
Display Resolution 0.1 dB
Spectrum Measurement
Frequency Range (Return Path) 4 to 205 MHz
Frequency Range (Forward Path) 5 to 1250 MHz
Dual Return Path Diplexers 42 MHz: 4 to 42 MHz; 85 MHz: 4 to 85 MHz
Manually Adjustable Resolution Bandwidth Return Path: 300 kHz; Forward Path: 10, 30, 100, and 300 kHz; 1 and 3 MHz
Auto Ranging Resolution Bandwidth 10 kHz: Span ≤ 3.5 MHz; 30 kHz: Span ≤ 12.0 MHz; 100 kHz: Span ≤ 35.9 MHz; 300 kHz: Span ≤ 300 MHz; 1 MHz: Span ≤ 359.2 MHz; 3 MHz: Span ≥ 359.3 MHz
Display Spans Return Path: 4 to 42 MHz, 4 to 65 MHz, 4 to 85 MHz or 4 to 205 MHz; Forward Path: User-selectable in 1 kHz steps
Display Scale 1, 2, 5, 7.5 or 10 dB/division
Display Range 8 vertical divisions
when marker bar is hidden
Spurious Free Dynamic Range 60 dB
@ 25° C (77° F) (+50 dBmV)
Sensitivity (terminated) Return Path: -40 dBmV (4 to 205 MHz); Forward Path: -40 dBmV (5 to 1250 MHz)
Digital Channel Measurement
Deep Interleave Compatibility Yes
Downstream MER 40 ±2 dB @ +6 dBmV RF Input Level; 34 ±2 dB @ -6 dBmV RF Input Level
Downstream BER Method True BER, derived from code words not from MER
Downstream BER Standard ITU J.83 annex A, B, C
Downstream BER Range 1 E-7 to 1 E-9
@ -6 dBmV RF Input Level
Symbol Rates ≥ 2 MSPS; ≤ 6.952 MSPS
Cable Modem Measurement
Protocol Support DOCSIS 1.1 / 2.0 / 3.0 / 3.1; SNMP V1, V2c, V3
DOCSIS 3.1: DOCSIS 3.1 option equipped meters only
Compliance Certificates FCC
CM Diplexer 85 MHz: 5 to 85 MHz
Receiver Frequency (edge to edge) 108 to 1218 MHz
Receiver Channel Bandwidth 6 MHz
Receiver Signal Level -15 to 15 dBmV
DOCSIS 3.0 Demodulation 64 QAM, 256 QAM
DOCSIS 3.0 Downstream Data Rate Up to 1.2 Gbps with 32 downstream channel bonding (DOCSIS 32x8)
DOCSIS 3.1 Demodulation Multi-Carrier OFDM 16 to 4096 QAM
DOCSIS 3.1 option equipped meters only
DOCSIS 3.1 Downstream Data Rate Up to 2.5 Gbps with 2 OFDM 196 MHz Downstream Channels
DOCSIS 3.1 option equipped meters only
Transmitter Frequency (edge to edge) 5 to 85 MHz
Transmitter Signal Level Controlled by CMTS though power ranging function
DOCSIS 3.0 Modulation QPSK, 8 QAM, 16 QAM, 32 QAM, 64 QAM, and 128 QAM (SCDMA only)
DOCSIS 3.0 Upstream Data Rate Up to 320 Mbps with 8 upstream channels bonding
DOCSIS 3.1 Modulation Multi-Carrier OFDMA BPSK to 4096 QAM
DOCSIS 3.1 option equipped meters only
DOCSIS 3.1 Upstream Data Rate Up to 1 Gbps with 2 OFDMA 96 MHz Upstream Channels
DOCSIS 3.1 option equipped meters only
Carrier-to-Noise Measurement
Minimum Input Level for Full Range +10 dBmV
In-service, non-scrambled standard channels only
Dynamic Range 50 dB
Resolution < 0.5 dB
Tilt Measurement
Max Number of Carriers 14
dependent on favorite channel setup
High/Low Delta Resolution 0.1 dB
Scan Video, audio, pilot, and digital carriers
Analog and Digital Hum
Minimum Input Level 0 dBmV
In-service, non-scrambled standard channels only
Range 0 to 5%
Resolution 0.10%
Accuracy ±0.5%
Frequency Domain Reflectometer
Velocity of Propagation Adjustable from 60.0 to 99.0% in 0.1% increments
Working Distance Minimum: 755 feet (230 meters) @ VoP of 60.0%; Maximum: 1247 feet (380 meters) @ VoP of 99.0%
Amplitude Range 0 to -80 dBRL
Distance Accuracy 5 feet
Source Generator
Modulation CW, 16 QAM, 32 QAM, 64 QAM, 128 QAM, 256 QAM, OFDM (4K/8K)
OFDM: DOCSIS 3.1 option equipped meters only
OFDM Subcarrier Modulation 16 to 4096 QAM, PLC Configurable
DOCSIS 3.1 option equipped meters only
Frequency Range 5 to 85 MHz
Source Width CW: 50 kHz; QAM: 6 MHz; OFDM: 6 to 24 MHz
OFDM: DOCSIS 3.1 option equipped meters only
Amplitude CW: Adjustable from 10 to 55 dBmV; QAM: Adjustable from 10 to 45 dBmV; OFDM: Adjustable from 10 to 40 dBmV
OFDM: DOCSIS 3.1 option equipped meters only
QAM Symbol Rates 0.64, 1.28, 2.56, 5.12 MSPS
QAM Error Rates BER: Adjustable from 0 to 1.00E-2; MER: > 38 dB
CW Source Accuracy ±2 dB
Optical Power Meter
Finish UPC and APC
Additional Connectors FC/SC/ST
Measurement Range -50 dBm to +26 dBm
Display Resolution 0.01 dB
Tone Detection Range -30 dBm to +6 dBm
Tone Detection 270 Hz, 330 Hz, 1 kHz, 2 kHz
Wavelengths 1310 nm, 1490 nm, 1550 nm
Accuracy +/-0.5dB > -40 dBm; +/- 1dB < -40 dBm
@ 25º C
Visual Fault Locator (VFL)
Port Style FC Style Adapter
Fiber Size 9/125 μm
Wavelength 650 nm
Output Power 3.0 mW
Pulse Duration CW (always on) or 2 Hz (0.25 sec pulse)
Maximum Radiant Power < 5.0 mW
Turn-On Safety Delay 2 seconds
Physical
Construction Rubber overmolded plastic housing
Control Glow in the dark keypad and LCD touchscreen and/or via a wireless connection to a mobile device such as a laptop, tablet, iPad® or iPhone®, or Android® handset
Display Color LCD touchscreen, 800 x 480 pixels (approx 4.5” x 2.75”)
1G DSP display
Annunciators Audible annunciator for key strokes
Antenna Internal WiFi antenna, 2 dB gain
Flashlight High-intensity LED (0.25W)
Dimensions w/o Case (H x W x D) 8.6 x 6.1 x 2.00 in (21.84 x 15.94 x 5.08 cm)
Dimensions w/ Case (H x W x D) 9.6 x 7.1 x 3.00 in (24.38 x 18.03 x 7.62 cm)
Weight w/o Case 3.75 lbs (1.70 Kg)
1G DSP
Weight w/ Case 4.75 lbs (2.15 Kg)
1G DSP
Interfaces
Tx Test Port 75 Ohm Replaceable F-Type Connector
Source Generator Output Transmission Only
Tx/Rx Test Port 75 Ohm Replaceable F-Type Connector
Upstream and Downstream RF Measurements, DOCSIS 3.1 Modem
Ethernet RJ45 Management Port (10/100 Mbps); RJ45 Electrical Test Port (10/100/1000 Base-T); SFP Optical Test Port (100/1000 Base-X)
WiFi 802.11 b/g/n 2.4/5 GHz WiFi Adapter
USB USB 2.0 Type-A Standard Port
Battery and Power
Operating Time 12 hours plus, dependent on use
1G DSP
Charge Time 4 hours
Battery Three 2600 mAh @ 7.4V Li-Ion internal batteries, factory replaceable
1G DSP
Power Adapter Input: 100 to 240 VAC ~ 50 to 60 Hz, 1.2A Max; Output: 15 VDC, 3.34A
Environmental
Storage -18° to +50° C (0° to 122° F)
Operating Temperature 0° to +50° C (32° to 122° F)

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • Cable plant maintenance
  • Return spectrum analysis
  • Level, C/N, QAM and OFDM measurement
  • Channel plan scan with tilt measurement
  • Upstream and forward amplifier balancing
  • Ingress troubleshooting
  • Ethernet service testing
  • Fiber optical power and fault location testing
  • Home leakage testing

Options & Accessories

Option Description
TRI-LKG-HL-METER-KIT Seeker Home Leakage Companion Kit — Seeker HL Source Transmitter, Dual-Band Antenna, Near-Field Probe and Case
TRI-DSP-SW-HL-LKG-OPT DSP Meter Leakage Software Option
TRI-ACCY-RF-TEST-CBL I/O-15 Precision test cable
TRI-ISTOP-1000MHZ I-Stop 1 GHz Test Probe — Ingress troubleshooting probe
TRI-ISTOP-1250MHZ I-Stop Test Probe — Ingress troubleshooting probe
TRI-TLB-46-LPF TLB-46 Return measurement low-pass filter
MP-80A MP-80A USB Optical Power Meter
FBP-P5000i P5000i USB Fiber Scope
TRI-DSP-1G-CASE-REPL Replacement fitted case
TRI-DSP-STRAP-REPL Replacement shoulder strap
TRI-DSP-PWR-ADPT-NEW Replacement charger (no power cord)

Documents & Resources