VIAVI Trilithic DSP Series meters including the 1G DSP plant maintenance meter
VIAVI / DSP Series / Plant Maintenance Meters
1G DSP with OPM/VFL Sweep

VIAVI Trilithic 1G DSP with OPM/VFL Sweep DOCSIS 3.1 Plant Maintenance Meter with Active Sweep

DOCSIS 3.1 plant maintenance meter with active sweep, built-in optical power meter and visual fault locator.

Channel Bandwidth
6 MHz and 8 MHz
Amplitude Range
-40 dBmV to +50 dBmV
Modulation Types
Analog: NTSC, PAL B/D/G/H/I/K/N and SECAM B/D/G/H/I/K; Digital: 16/32/64/128/256 QAM Annex A, 64/256 QAM Annex B/C, OFDM 4K/8K
Analog Measurement Accuracy
±0.75 dB @ 77° F (25° C); ±2.0 dB from 0° to +50° C (32° to 122° F)
Datasheet

Overview

The 1G DSP with OPM/VFL Sweep (part number TRI-DSP-1G-D31-VFL-SWEEP) is the plant maintenance model of the VIAVI Trilithic DSP Series. It is listed as a plant maintenance meter with active sweep, an optical power meter and a visual fault locator. One instrument combines CATV, DOCSIS 3.1 cable modem, Gigabit Ethernet and optical testing for systemwide work.

The meter runs throughput tests at up to a gigabit per second through a dedicated Ethernet test port or the internal cable modem. It can make roundtrip or one-way Key Parameter Index (KPI) measurements, and its constant payload testing for Layer 2 through Layer 4 checks Ethernet Service Level Agreement (SLA) and Quality of Service (QoS) metrics.

Optical testing

The OPM/VFL hardware package adds a built-in FTTx-ready optical power meter for testing passive optical networks. It makes absolute and relative measurements at 1310 nm, 1490 nm and 1550 nm, with interchangeable FC, SC and ST style adapters. The visual fault locator emits visible red light to find loss points in patch cords, patch panels and enclosures, and to locate light escaping from damaged single-mode and multi-mode fiber.

Sweep functions

The Sweep model adds the RSA high-resolution return sweep (with the 8310 RSA), forward active sweep (with the 8300 FST), the SSR high-speed return sweep and SST Compare (with the 9581 SST). With these, the meter can work as a return path sweep transmitter, set the tilt and gain of distribution amplifiers, and find bursty ingress.

Operation

The 1G DSP has a large, high-resolution color touchscreen, pass/fail indicators and autotest apps. It also offers remote control through a web browser, long battery life with a quick charge time, and a glow-in-the-dark keypad. Test data and instrument assets can be synced with StrataSync over Ethernet, DOCSIS or WiFi.

Key Features

  • Combines CATV, DOCSIS 3.1 cable modem, Gigabit Ethernet and optical testing in one instrument
  • 1.25 GHz frequency range
  • Auto-discovery of channel plans
  • Throughput testing speeds of up to a gigabit/sec using a dedicated Ethernet test port or the internal cable modem
  • Roundtrip or one-way KPI measurements with constant payload testing for Layer 2 through Layer 4
  • Built-in FTTx ready optical power meter for 1310 nm, 1490 nm and 1550 nm
  • Visual fault locator for locating loss points in patch cords, patch panels and enclosures
  • Internal DOCSIS 3.1 modem that operates in both DOCSIS 3.0 (32x8) and DOCSIS 3.1 modes
  • QAM and OFDM channel measurements including PLC constellation, MER and pre/post BER
  • Upstream Traffic Control Plus, upstream linear distortion measurements and QAM Error Vector Spectrum
  • RSA high-resolution return sweep with the 8310 RSA
  • Forward active sweep with headend-injected carriers
  • SSR high-speed return sweep and SST Compare with the 9581 SST
  • Dual RF test ports and source generator with CW, QAM and OFDM carriers from 5 to 85 MHz
  • Frequency domain reflectometer for distance to cable faults
  • Built-in 802.11 b/g/n 2.4/5 GHz WiFi adapter with survey test mode
  • Up to 5 technician user profiles
  • Remote meter control via a web browser
  • Large, high resolution color touchscreen and glow in the dark keypad
  • StrataSync asset and test data management

Specifications

Level Measurement
Channel Bandwidth 6 MHz and 8 MHz
Amplitude Range -40 dBmV to +50 dBmV
Modulation Types Analog: NTSC, PAL B/D/G/H/I/K/N and SECAM B/D/G/H/I/K; Digital: 16/32/64/128/256 QAM Annex A, 64/256 QAM Annex B/C, OFDM 4K/8K
OFDM on DOCSIS 3.1 option equipped meters only
Analog Measurement Accuracy ±0.75 dB @ 77° F (25° C); ±2.0 dB from 0° to +50° C (32° to 122° F)
Digital Measurement Accuracy ±0.75 dB @ 77° F (25° C); ±2.5 dB from 0° to +50° C (32° to 122° F)
Display Resolution 0.1 dB
Spectrum Measurement
Frequency Range Return Path: 4 to 205 MHz; Forward Path: 5 to 1250 MHz
Dual Return Path Diplexers 42 MHz: 4 to 42 MHz; 85 MHz: 4 to 85 MHz
Manually Adjustable Resolution Bandwidth Return Path: 300 kHz; Forward Path: 10, 30, 100, and 300 kHz; 1 and 3 MHz
Auto Ranging Resolution Bandwidth 10 kHz: Span ≤ 3.5 MHz; 30 kHz: Span ≤ 12.0 MHz; 100 kHz: Span ≤ 35.9 MHz; 300 kHz: Span ≤ 300 MHz; 1 MHz: Span ≤ 359.2 MHz; 3 MHz: Span ≥ 359.3 MHz
Display Spans Return Path: 4 to 42 MHz, 4 to 65 MHz, 4 to 85 MHz or 4 to 205 MHz; Forward Path: User-selectable in 1 kHz steps
Display Scale 1, 2, 5, 7.5 or 10 dB/division
Display Range 8 vertical divisions
when marker bar is hidden
Spurious Free Dynamic Range 60 dB
@ 25° C (77° F) (+50 dBmV)
Sensitivity (terminated) Return Path: -40 dBmV (4 to 205 MHz); Forward Path: -40 dBmV (5 to 1250 MHz)
Digital Channel Measurement
Deep Interleave Compatibility Yes
Downstream MER 40 ±2 dB @ +6 dBmV RF Input Level; 34 ±2 dB @ -6 dBmV RF Input Level
Downstream BER Method True BER, derived from code words not from MER
Downstream BER Standard ITU J.83 annex A, B, C
Downstream BER Range 1 E-7 to 1 E-9 @ -6 dBmV RF Input Level
Symbol Rates ≥ 2 MSPS; ≤ 6.952 MSPS
Cable Modem Measurement
Protocol Support DOCSIS 1.1 / 2.0 / 3.0 / 3.1; SNMP V1, V2c, V3
DOCSIS 3.1 on DOCSIS 3.1 option equipped meters only
Compliance Certificates FCC
CM Diplexer 85 MHz: 5 to 85 MHz
Receiver Frequency (edge to edge) 108 to 1218 MHz
Receiver Channel Bandwidth 6 MHz
Receiver Signal Level -15 to 15 dBmV
DOCSIS 3.0 Demodulation 64 QAM, 256 QAM
DOCSIS 3.0 Downstream Data Rate Up to 1.2 Gbps with 32 downstream channel bonding (DOCSIS 32x8)
DOCSIS 3.1 Demodulation Multi-Carrier OFDM 16 to 4096 QAM
DOCSIS 3.1 Downstream Data Rate Up to 2.5 Gbps with 2 OFDM 196 MHz Downstream Channels
Transmitter Frequency (edge to edge) 5 to 85 MHz
Transmitter Signal Level Controlled by CMTS though power ranging function
DOCSIS 3.0 Modulation QPSK, 8 QAM, 16 QAM, 32 QAM, 64 QAM, and 128 QAM (SCDMA only)
DOCSIS 3.0 Upstream Data Rate Up to 320 Mbps with 8 upstream channels bonding
DOCSIS 3.1 Modulation Multi-Carrier OFDMA BPSK to 4096 QAM
DOCSIS 3.1 Upstream Data Rate Up to 1 Gbps with 2 OFDMA 96 MHz Upstream Channels
Carrier-to-Noise, Tilt and Hum
C/N Minimum Input Level for Full Range +10 dBmV
In-service, non-scrambled standard channels only
C/N Dynamic Range 50 dB
C/N Resolution < 0.5 dB
Tilt Max Number of Carriers 14
dependent on favorite channel setup
Tilt High/Low Delta Resolution 0.1 dB
Tilt Scan Video, audio, pilot, and digital carriers
Hum Minimum Input Level 0 dBmV
In-service, non-scrambled standard channels only
Hum Range 0 to 5%
Hum Resolution 0.10%
Hum Accuracy ±0.5%
Frequency Domain Reflectometer
Velocity of Propagation Adjustable from 60.0 to 99.0% in 0.1% increments
Working Distance Minimum: 755 feet (230 meters) @ VoP of 60.0%; Maximum: 1247 feet (380 meters) @ VoP of 99.0%
Amplitude Range 0 to -80 dBRL
Distance Accuracy 5 feet
Source Generator
Modulation CW, 16 QAM, 32 QAM, 64 QAM, 128 QAM, 256 QAM, OFDM (4K/8K)
OFDM on DOCSIS 3.1 option equipped meters only
OFDM Subcarrier Modulation 16 to 4096 QAM, PLC Configurable
DOCSIS 3.1 option equipped meters only
Frequency Range 5 to 85 MHz
Source Width CW: 50 kHz; QAM: 6 MHz; OFDM: 6 to 24 MHz
Amplitude CW: Adjustable from 10 to 55 dBmV; QAM: Adjustable from 10 to 45 dBmV; OFDM: Adjustable from 10 to 40 dBmV
QAM Symbol Rates 0.64, 1.28, 2.56, 5.12 MSPS
QAM Error Rates BER: Adjustable from 0 to 1.00E-2; MER: > 38 dB
CW Source Accuracy ±2 dB
Optical Power Meter
Finish UPC and APC
Additional Connectors FC/SC/ST
Measurement Range -50 dBm to +26 dBm
Display Resolution 0.01 dB
Tone Detection Range -30 dBm to +6 dBm
Tone Detection 270 Hz, 330 Hz, 1 kHz, 2 kHz
Wavelengths 1310 nm, 1490 nm, 1550 nm
Accuracy +/-0.5dB > -40 dBm @ 25º C; +/- 1dB < -40 dBm @ 25º C
Visual Fault Locator (VFL)
Port Style FC Style Adapter
Fiber Size 9/125 μm
Wavelength 650 nm
Output Power 3.0 mW
Class III visible red light laser
Pulse Duration CW (always on) or 2 Hz (0.25 sec pulse)
Maximum Radiant Power < 5.0 mW
Turn-On Safety Delay 2 seconds
RSA Return Sweep
Sweep Points up to 643 individual sweep points
Full sweep displayed every four seconds; requires 8310 RSA Return SpeedSweep Analyzer in the headend
Physical
Construction Rubber overmolded plastic housing
Control Glow in the dark keypad and LCD touchscreen and/or via a wireless connection to a mobile device such as a laptop, tablet, iPad® or iPhone®, or Android® handset
Display Color LCD touchscreen, 800 x 480 pixels (approx 4.5” x 2.75”)
1G DSP value
Annunciators Audible annunciator for key strokes
Antenna Internal WiFi antenna, 2 dB gain
Flashlight High-intensity LED (0.25W)
Dimensions w/o Case (H x W x D) 8.6 x 6.1 x 2.00 in (21.84 x 15.94 x 5.08 cm)
Dimensions w/ Case (H x W x D) 9.6 x 7.1 x 3.00 in (24.38 x 18.03 x 7.62 cm)
Weight w/o Case 3.75 lbs (1.70 Kg)
1G DSP value
Weight w/ Case 4.75 lbs (2.15 Kg)
1G DSP value
Interfaces
Tx Test Port 75 Ohm Replaceable F-Type Connector
Source Generator Output Transmission Only
Tx/Rx Test Port 75 Ohm Replaceable F-Type Connector
Upstream and Downstream RF Measurements, DOCSIS 3.1 Modem
Ethernet RJ45 Management Port (10/100 Mbps); RJ45 Electrical Test Port (10/100/1000 Base-T); SFP Optical Test Port (100/1000 Base-X)
Test ports on 1G only
WiFi 802.11 b/g/n 2.4/5 GHz WiFi Adapter
USB USB 2.0 Type-A Standard Port
Battery and Power
Operating Time 12 hours plus, dependent on use
1G DSP value
Charge Time 4 hours
Battery Two 2600 mAh @ 7.4V Li-Ion internal batteries, factory replaceable (1G DSP, Three 2600 mAh batteries)
1G DSP uses three 2600 mAh batteries
Power Adapter Input: 100 to 240 VAC ~ 50 to 60 Hz, 1.2A Max; Output: 15 VDC, 3.34A
Environmental
Storage -18° to +50° C (0° to 122° F)
Operating Temperature 0° to +50° C (32° to 122° F)
Ordering
Part Number TRI-DSP-1G-D31-VFL-SWEEP
Plant Maintenance Meter with Active Sweep, optical power meter and visual fault locator

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • Cable plant maintenance
  • Return spectrum analysis
  • Level, C/N, QAM and OFDM measurement
  • Channel plan scan with tilt measurement
  • Upstream and forward sweep and amplifier balancing
  • Ingress troubleshooting
  • Ethernet SLA and QoS verification
  • Passive optical network power testing
  • Fiber patch cord and patch panel fault location
  • DOCSIS 3.1 deployment testing

Options & Accessories

Option Description
TRI-LKG-HL-METER-KIT Home Leakage Test Kit — Seeker Home Leakage Companion Kit: Seeker HL Source Transmitter, Dual-Band Antenna, Near-Field Probe and Case
TRI-DSP-SW-HL-LKG-OPT DSP Meter Leakage Software Option
TRI-ACCY-RF-TEST-CBL I/O-15 Precision test cable
TRI-ISTOP-1000MHZ I-Stop 1 GHz Test Probe — Ingress troubleshooting probe
TRI-ISTOP-1250MHZ I-Stop Test Probe — Ingress troubleshooting probe
TRI-TLB-46-LPF TLB-46 Return measurement low-pass filter
MP-80A MP-80A USB Optical Power Meter
FBP-P5000i P5000i USB Fiber Scope
TRI-DSP-1G-CASE-REPL Replacement fitted case (1G DSP)
TRI-DSP-STRAP-REPL Replacement shoulder strap
TRI-DSP-PWR-ADPT-NEW Replacement charger (no power cord)

Documents & Resources