VIAVI Trilithic 1G DSP with OPM/VFL Sweep DOCSIS 3.1 Plant Maintenance Meter with Active Sweep
DOCSIS 3.1 plant maintenance meter with active sweep, built-in optical power meter and visual fault locator.
- Channel Bandwidth
- 6 MHz and 8 MHz
- Amplitude Range
- -40 dBmV to +50 dBmV
- Modulation Types
- Analog: NTSC, PAL B/D/G/H/I/K/N and SECAM B/D/G/H/I/K; Digital: 16/32/64/128/256 QAM Annex A, 64/256 QAM Annex B/C, OFDM 4K/8K
- Analog Measurement Accuracy
- ±0.75 dB @ 77° F (25° C); ±2.0 dB from 0° to +50° C (32° to 122° F)
Overview
The 1G DSP with OPM/VFL Sweep (part number TRI-DSP-1G-D31-VFL-SWEEP) is the plant maintenance model of the VIAVI Trilithic DSP Series. It is listed as a plant maintenance meter with active sweep, an optical power meter and a visual fault locator. One instrument combines CATV, DOCSIS 3.1 cable modem, Gigabit Ethernet and optical testing for systemwide work.
The meter runs throughput tests at up to a gigabit per second through a dedicated Ethernet test port or the internal cable modem. It can make roundtrip or one-way Key Parameter Index (KPI) measurements, and its constant payload testing for Layer 2 through Layer 4 checks Ethernet Service Level Agreement (SLA) and Quality of Service (QoS) metrics.
Optical testing
The OPM/VFL hardware package adds a built-in FTTx-ready optical power meter for testing passive optical networks. It makes absolute and relative measurements at 1310 nm, 1490 nm and 1550 nm, with interchangeable FC, SC and ST style adapters. The visual fault locator emits visible red light to find loss points in patch cords, patch panels and enclosures, and to locate light escaping from damaged single-mode and multi-mode fiber.
Sweep functions
The Sweep model adds the RSA high-resolution return sweep (with the 8310 RSA), forward active sweep (with the 8300 FST), the SSR high-speed return sweep and SST Compare (with the 9581 SST). With these, the meter can work as a return path sweep transmitter, set the tilt and gain of distribution amplifiers, and find bursty ingress.
Operation
The 1G DSP has a large, high-resolution color touchscreen, pass/fail indicators and autotest apps. It also offers remote control through a web browser, long battery life with a quick charge time, and a glow-in-the-dark keypad. Test data and instrument assets can be synced with StrataSync over Ethernet, DOCSIS or WiFi.
Key Features
- Combines CATV, DOCSIS 3.1 cable modem, Gigabit Ethernet and optical testing in one instrument
- 1.25 GHz frequency range
- Auto-discovery of channel plans
- Throughput testing speeds of up to a gigabit/sec using a dedicated Ethernet test port or the internal cable modem
- Roundtrip or one-way KPI measurements with constant payload testing for Layer 2 through Layer 4
- Built-in FTTx ready optical power meter for 1310 nm, 1490 nm and 1550 nm
- Visual fault locator for locating loss points in patch cords, patch panels and enclosures
- Internal DOCSIS 3.1 modem that operates in both DOCSIS 3.0 (32x8) and DOCSIS 3.1 modes
- QAM and OFDM channel measurements including PLC constellation, MER and pre/post BER
- Upstream Traffic Control Plus, upstream linear distortion measurements and QAM Error Vector Spectrum
- RSA high-resolution return sweep with the 8310 RSA
- Forward active sweep with headend-injected carriers
- SSR high-speed return sweep and SST Compare with the 9581 SST
- Dual RF test ports and source generator with CW, QAM and OFDM carriers from 5 to 85 MHz
- Frequency domain reflectometer for distance to cable faults
- Built-in 802.11 b/g/n 2.4/5 GHz WiFi adapter with survey test mode
- Up to 5 technician user profiles
- Remote meter control via a web browser
- Large, high resolution color touchscreen and glow in the dark keypad
- StrataSync asset and test data management
Specifications
| Channel Bandwidth | 6 MHz and 8 MHz |
|---|---|
| Amplitude Range | -40 dBmV to +50 dBmV |
| Modulation Types |
Analog: NTSC, PAL B/D/G/H/I/K/N and SECAM B/D/G/H/I/K; Digital: 16/32/64/128/256 QAM Annex A, 64/256 QAM Annex B/C, OFDM 4K/8K
OFDM on DOCSIS 3.1 option equipped meters only
|
| Analog Measurement Accuracy | ±0.75 dB @ 77° F (25° C); ±2.0 dB from 0° to +50° C (32° to 122° F) |
| Digital Measurement Accuracy | ±0.75 dB @ 77° F (25° C); ±2.5 dB from 0° to +50° C (32° to 122° F) |
| Display Resolution | 0.1 dB |
| Frequency Range | Return Path: 4 to 205 MHz; Forward Path: 5 to 1250 MHz |
|---|---|
| Dual Return Path Diplexers | 42 MHz: 4 to 42 MHz; 85 MHz: 4 to 85 MHz |
| Manually Adjustable Resolution Bandwidth | Return Path: 300 kHz; Forward Path: 10, 30, 100, and 300 kHz; 1 and 3 MHz |
| Auto Ranging Resolution Bandwidth | 10 kHz: Span ≤ 3.5 MHz; 30 kHz: Span ≤ 12.0 MHz; 100 kHz: Span ≤ 35.9 MHz; 300 kHz: Span ≤ 300 MHz; 1 MHz: Span ≤ 359.2 MHz; 3 MHz: Span ≥ 359.3 MHz |
| Display Spans | Return Path: 4 to 42 MHz, 4 to 65 MHz, 4 to 85 MHz or 4 to 205 MHz; Forward Path: User-selectable in 1 kHz steps |
| Display Scale | 1, 2, 5, 7.5 or 10 dB/division |
| Display Range |
8 vertical divisions
when marker bar is hidden
|
| Spurious Free Dynamic Range |
60 dB
@ 25° C (77° F) (+50 dBmV)
|
| Sensitivity (terminated) | Return Path: -40 dBmV (4 to 205 MHz); Forward Path: -40 dBmV (5 to 1250 MHz) |
| Deep Interleave Compatibility | Yes |
|---|---|
| Downstream MER | 40 ±2 dB @ +6 dBmV RF Input Level; 34 ±2 dB @ -6 dBmV RF Input Level |
| Downstream BER Method | True BER, derived from code words not from MER |
| Downstream BER Standard | ITU J.83 annex A, B, C |
| Downstream BER Range | 1 E-7 to 1 E-9 @ -6 dBmV RF Input Level |
| Symbol Rates | ≥ 2 MSPS; ≤ 6.952 MSPS |
| Protocol Support |
DOCSIS 1.1 / 2.0 / 3.0 / 3.1; SNMP V1, V2c, V3
DOCSIS 3.1 on DOCSIS 3.1 option equipped meters only
|
|---|---|
| Compliance Certificates | FCC |
| CM Diplexer | 85 MHz: 5 to 85 MHz |
| Receiver Frequency (edge to edge) | 108 to 1218 MHz |
| Receiver Channel Bandwidth | 6 MHz |
| Receiver Signal Level | -15 to 15 dBmV |
| DOCSIS 3.0 Demodulation | 64 QAM, 256 QAM |
| DOCSIS 3.0 Downstream Data Rate | Up to 1.2 Gbps with 32 downstream channel bonding (DOCSIS 32x8) |
| DOCSIS 3.1 Demodulation | Multi-Carrier OFDM 16 to 4096 QAM |
| DOCSIS 3.1 Downstream Data Rate | Up to 2.5 Gbps with 2 OFDM 196 MHz Downstream Channels |
| Transmitter Frequency (edge to edge) | 5 to 85 MHz |
| Transmitter Signal Level | Controlled by CMTS though power ranging function |
| DOCSIS 3.0 Modulation | QPSK, 8 QAM, 16 QAM, 32 QAM, 64 QAM, and 128 QAM (SCDMA only) |
| DOCSIS 3.0 Upstream Data Rate | Up to 320 Mbps with 8 upstream channels bonding |
| DOCSIS 3.1 Modulation | Multi-Carrier OFDMA BPSK to 4096 QAM |
| DOCSIS 3.1 Upstream Data Rate | Up to 1 Gbps with 2 OFDMA 96 MHz Upstream Channels |
| C/N Minimum Input Level for Full Range |
+10 dBmV
In-service, non-scrambled standard channels only
|
|---|---|
| C/N Dynamic Range | 50 dB |
| C/N Resolution | < 0.5 dB |
| Tilt Max Number of Carriers |
14
dependent on favorite channel setup
|
| Tilt High/Low Delta Resolution | 0.1 dB |
| Tilt Scan | Video, audio, pilot, and digital carriers |
| Hum Minimum Input Level |
0 dBmV
In-service, non-scrambled standard channels only
|
| Hum Range | 0 to 5% |
| Hum Resolution | 0.10% |
| Hum Accuracy | ±0.5% |
| Velocity of Propagation | Adjustable from 60.0 to 99.0% in 0.1% increments |
|---|---|
| Working Distance | Minimum: 755 feet (230 meters) @ VoP of 60.0%; Maximum: 1247 feet (380 meters) @ VoP of 99.0% |
| Amplitude Range | 0 to -80 dBRL |
| Distance Accuracy | 5 feet |
| Modulation |
CW, 16 QAM, 32 QAM, 64 QAM, 128 QAM, 256 QAM, OFDM (4K/8K)
OFDM on DOCSIS 3.1 option equipped meters only
|
|---|---|
| OFDM Subcarrier Modulation |
16 to 4096 QAM, PLC Configurable
DOCSIS 3.1 option equipped meters only
|
| Frequency Range | 5 to 85 MHz |
| Source Width | CW: 50 kHz; QAM: 6 MHz; OFDM: 6 to 24 MHz |
| Amplitude | CW: Adjustable from 10 to 55 dBmV; QAM: Adjustable from 10 to 45 dBmV; OFDM: Adjustable from 10 to 40 dBmV |
| QAM Symbol Rates | 0.64, 1.28, 2.56, 5.12 MSPS |
| QAM Error Rates | BER: Adjustable from 0 to 1.00E-2; MER: > 38 dB |
| CW Source Accuracy | ±2 dB |
| Finish | UPC and APC |
|---|---|
| Additional Connectors | FC/SC/ST |
| Measurement Range | -50 dBm to +26 dBm |
| Display Resolution | 0.01 dB |
| Tone Detection Range | -30 dBm to +6 dBm |
| Tone Detection | 270 Hz, 330 Hz, 1 kHz, 2 kHz |
| Wavelengths | 1310 nm, 1490 nm, 1550 nm |
| Accuracy | +/-0.5dB > -40 dBm @ 25º C; +/- 1dB < -40 dBm @ 25º C |
| Port Style | FC Style Adapter |
|---|---|
| Fiber Size | 9/125 μm |
| Wavelength | 650 nm |
| Output Power |
3.0 mW
Class III visible red light laser
|
| Pulse Duration | CW (always on) or 2 Hz (0.25 sec pulse) |
| Maximum Radiant Power | < 5.0 mW |
| Turn-On Safety Delay | 2 seconds |
| Sweep Points |
up to 643 individual sweep points
Full sweep displayed every four seconds; requires 8310 RSA Return SpeedSweep Analyzer in the headend
|
|---|
| Construction | Rubber overmolded plastic housing |
|---|---|
| Control | Glow in the dark keypad and LCD touchscreen and/or via a wireless connection to a mobile device such as a laptop, tablet, iPad® or iPhone®, or Android® handset |
| Display |
Color LCD touchscreen, 800 x 480 pixels (approx 4.5” x 2.75”)
1G DSP value
|
| Annunciators | Audible annunciator for key strokes |
| Antenna | Internal WiFi antenna, 2 dB gain |
| Flashlight | High-intensity LED (0.25W) |
| Dimensions w/o Case (H x W x D) | 8.6 x 6.1 x 2.00 in (21.84 x 15.94 x 5.08 cm) |
| Dimensions w/ Case (H x W x D) | 9.6 x 7.1 x 3.00 in (24.38 x 18.03 x 7.62 cm) |
| Weight w/o Case |
3.75 lbs (1.70 Kg)
1G DSP value
|
| Weight w/ Case |
4.75 lbs (2.15 Kg)
1G DSP value
|
| Tx Test Port |
75 Ohm Replaceable F-Type Connector
Source Generator Output Transmission Only
|
|---|---|
| Tx/Rx Test Port |
75 Ohm Replaceable F-Type Connector
Upstream and Downstream RF Measurements, DOCSIS 3.1 Modem
|
| Ethernet |
RJ45 Management Port (10/100 Mbps); RJ45 Electrical Test Port (10/100/1000 Base-T); SFP Optical Test Port (100/1000 Base-X)
Test ports on 1G only
|
| WiFi | 802.11 b/g/n 2.4/5 GHz WiFi Adapter |
| USB | USB 2.0 Type-A Standard Port |
| Operating Time |
12 hours plus, dependent on use
1G DSP value
|
|---|---|
| Charge Time | 4 hours |
| Battery |
Two 2600 mAh @ 7.4V Li-Ion internal batteries, factory replaceable (1G DSP, Three 2600 mAh batteries)
1G DSP uses three 2600 mAh batteries
|
| Power Adapter | Input: 100 to 240 VAC ~ 50 to 60 Hz, 1.2A Max; Output: 15 VDC, 3.34A |
| Storage | -18° to +50° C (0° to 122° F) |
|---|---|
| Operating Temperature | 0° to +50° C (32° to 122° F) |
| Part Number |
TRI-DSP-1G-D31-VFL-SWEEP
Plant Maintenance Meter with Active Sweep, optical power meter and visual fault locator
|
|---|
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- Cable plant maintenance
- Return spectrum analysis
- Level, C/N, QAM and OFDM measurement
- Channel plan scan with tilt measurement
- Upstream and forward sweep and amplifier balancing
- Ingress troubleshooting
- Ethernet SLA and QoS verification
- Passive optical network power testing
- Fiber patch cord and patch panel fault location
- DOCSIS 3.1 deployment testing
Options & Accessories
| Option | Description |
|---|---|
| TRI-LKG-HL-METER-KIT | Home Leakage Test Kit — Seeker Home Leakage Companion Kit: Seeker HL Source Transmitter, Dual-Band Antenna, Near-Field Probe and Case |
| TRI-DSP-SW-HL-LKG-OPT | DSP Meter Leakage Software Option |
| TRI-ACCY-RF-TEST-CBL | I/O-15 Precision test cable |
| TRI-ISTOP-1000MHZ | I-Stop 1 GHz Test Probe — Ingress troubleshooting probe |
| TRI-ISTOP-1250MHZ | I-Stop Test Probe — Ingress troubleshooting probe |
| TRI-TLB-46-LPF | TLB-46 Return measurement low-pass filter |
| MP-80A | MP-80A USB Optical Power Meter |
| FBP-P5000i | P5000i USB Fiber Scope |
| TRI-DSP-1G-CASE-REPL | Replacement fitted case (1G DSP) |
| TRI-DSP-STRAP-REPL | Replacement shoulder strap |
| TRI-DSP-PWR-ADPT-NEW | Replacement charger (no power cord) |