VIAVI Trilithic 1G DSP with OPM/VFL Pro Plant Maintenance Meter with Optical Power Meter and VFL
DOCSIS 3.1 plant maintenance meter combining CATV, cable modem and gigabit Ethernet testing with a built-in optical power meter and visual fault locator.
- Channel Bandwidth
- 6 MHz and 8 MHz
- Amplitude Range
- -40 dBmV to +50 dBmV
- Modulation Types (Analog)
- NTSC, PAL B/D/G/H/I/K/N and SECAM B/D/G/H/I/K
- Modulation Types (Digital)
- 16/32/64/128/256 QAM Annex A, 64/256 QAM Annex B/C, OFDM 4K/8K
Overview
The VIAVI Trilithic 1G DSP with OPM/VFL Pro (part number TRI-DSP-1G-D31-VFL-PRO) is a plant maintenance meter in the DSP Series. It combines CATV, DOCSIS 3.1 cable modem, Gigabit Ethernet and optical testing in one instrument for systemwide testing, and adds a built-in optical power meter (OPM) and visual fault locator (VFL) to the 1G DSP Pro configuration.
The meter achieves throughput testing speeds of up to a gigabit per second using a dedicated Ethernet test port or the internal cable modem. It performs roundtrip or one-way Key Parameter Index (KPI) measurements with constant payload testing for Layer 2 through Layer 4, for verification of Ethernet Service Level Agreement (SLA) and Quality of Service (QoS) metrics.
Optical testing
The optical hardware package includes a built-in FTTx-ready optical power meter for testing passive optical networks, with absolute and relative measurements at the ITU-T G983.3 recommended wavelengths of 1310 nm, 1490 nm and 1550 nm and interchangeable FC, SC and ST style adapters. The VFL emits a Class III visible red laser for locating loss points in patch cords, patch panels and enclosures on damaged single-mode and multi-mode fiber.
Operation
The 1G DSP has a large, high-resolution color touchscreen, simple pass/fail indicators and autotest apps. It supports remote meter control via a web browser, up to five user profiles, long battery life with a quick charge time, and a glow-in-the-dark keypad. Test results and configurations can be synchronized with VIAVI StrataSync over Ethernet, DOCSIS or WiFi.
Key Features
- Combines CATV, DOCSIS 3.1 cable modem, Gigabit Ethernet and optical testing in one meter
- Built-in optical power meter for 1310 nm, 1490 nm and 1550 nm
- Built-in visual fault locator for locating loss points in patch cords, patch panels and enclosures
- Throughput testing up to 1 GbE using a dedicated test port or the internal cable modem
- Roundtrip or one-way constant payload testing for Layer 2-4 Ethernet SLA and QoS verification
- SFP optical power measurement with link speed, wavelength, Tx power and Rx power
- Internal DOCSIS 3.1 modem operating in DOCSIS 3.0 (32x8) and DOCSIS 3.1 modes
- DOCSIS 3.1 OFDM signal measurements including PLC constellation, MER and pre/post BER
- Upstream Traffic Control Plus and Downstream QAM Error Vector Spectrum for ingress under carrier
- Upstream linear distortion testing: equalizer taps, group delay and in-channel response
- Frequency domain reflectometer and source generator with dual RF test ports
- Return spectrum 4 to 205 MHz and forward spectrum 5 to 1250 MHz
- Channel plan scan with tilt measurement and channel plan auto-discovery
- Built-in 802.11 b/g/n 2.4/5 GHz WiFi with survey mode
- Network test suite with Ping, VoIP, Throughput and Traceroute
- Remote control via web browser from PC, smartphone or tablet
- Multi-user support for up to 5 technicians
- Large color touchscreen with glow in the dark keypad
- StrataSync asset, configuration and test data management
Specifications
| Channel Bandwidth | 6 MHz and 8 MHz |
|---|---|
| Amplitude Range | -40 dBmV to +50 dBmV |
| Modulation Types (Analog) | NTSC, PAL B/D/G/H/I/K/N and SECAM B/D/G/H/I/K |
| Modulation Types (Digital) |
16/32/64/128/256 QAM Annex A, 64/256 QAM Annex B/C, OFDM 4K/8K
OFDM: DOCSIS 3.1 option equipped meters only
|
| Analog Measurement Accuracy | ±0.75 dB @ 77° F (25° C); ±2.0 dB from 0° to +50° C (32° to 122° F) |
| Digital Measurement Accuracy | ±0.75 dB @ 77° F (25° C); ±2.5 dB from 0° to +50° C (32° to 122° F) |
| Display Resolution | 0.1 dB |
| Frequency Range (Return Path) | 4 to 205 MHz |
|---|---|
| Frequency Range (Forward Path) | 5 to 1250 MHz |
| Dual Return Path Diplexers | 42 MHz: 4 to 42 MHz; 85 MHz: 4 to 85 MHz |
| Manually Adjustable Resolution Bandwidth | Return Path: 300 kHz; Forward Path: 10, 30, 100, and 300 kHz; 1 and 3 MHz |
| Auto Ranging Resolution Bandwidth | 10 kHz: Span ≤ 3.5 MHz; 30 kHz: Span ≤ 12.0 MHz; 100 kHz: Span ≤ 35.9 MHz; 300 kHz: Span ≤ 300 MHz; 1 MHz: Span ≤ 359.2 MHz; 3 MHz: Span ≥ 359.3 MHz |
| Display Spans | Return Path: 4 to 42 MHz, 4 to 65 MHz, 4 to 85 MHz or 4 to 205 MHz; Forward Path: User-selectable in 1 kHz steps |
| Display Scale | 1, 2, 5, 7.5 or 10 dB/division |
| Display Range |
8 vertical divisions
when marker bar is hidden
|
| Spurious Free Dynamic Range |
60 dB
@ 25° C (77° F) (+50 dBmV)
|
| Sensitivity (terminated) | Return Path: -40 dBmV (4 to 205 MHz); Forward Path: -40 dBmV (5 to 1250 MHz) |
| Deep Interleave Compatibility | Yes |
|---|---|
| Downstream MER | 40 ±2 dB @ +6 dBmV RF Input Level; 34 ±2 dB @ -6 dBmV RF Input Level |
| Downstream BER Method | True BER, derived from code words not from MER |
| Downstream BER Standard | ITU J.83 annex A, B, C |
| Downstream BER Range |
1 E-7 to 1 E-9
@ -6 dBmV RF Input Level
|
| Symbol Rates | ≥ 2 MSPS; ≤ 6.952 MSPS |
| Protocol Support | DOCSIS 1.1 / 2.0 / 3.0 / 3.1; SNMP V1, V2c, V3 |
|---|---|
| Compliance Certificates | FCC |
| CM Diplexer | 85 MHz: 5 to 85 MHz |
| Receiver Frequency (edge to edge) | 108 to 1218 MHz |
| Receiver Channel Bandwidth | 6 MHz |
| Receiver Signal Level | -15 to 15 dBmV |
| DOCSIS 3.0 Demodulation | 64 QAM, 256 QAM |
| DOCSIS 3.0 Downstream Data Rate | Up to 1.2 Gbps with 32 downstream channel bonding (DOCSIS 32x8) |
| DOCSIS 3.1 Demodulation |
Multi-Carrier OFDM 16 to 4096 QAM
DOCSIS 3.1 option equipped meters only
|
| DOCSIS 3.1 Downstream Data Rate |
Up to 2.5 Gbps with 2 OFDM 196 MHz Downstream Channels
DOCSIS 3.1 option equipped meters only
|
| Transmitter Frequency (edge to edge) | 5 to 85 MHz |
| Transmitter Signal Level | Controlled by CMTS though power ranging function |
| DOCSIS 3.0 Modulation | QPSK, 8 QAM, 16 QAM, 32 QAM, 64 QAM, and 128 QAM (SCDMA only) |
| DOCSIS 3.0 Upstream Data Rate | Up to 320 Mbps with 8 upstream channels bonding |
| DOCSIS 3.1 Modulation |
Multi-Carrier OFDMA BPSK to 4096 QAM
DOCSIS 3.1 option equipped meters only
|
| DOCSIS 3.1 Upstream Data Rate |
Up to 1 Gbps with 2 OFDMA 96 MHz Upstream Channels
DOCSIS 3.1 option equipped meters only
|
| Minimum Input Level for Full Range |
+10 dBmV
In-service, non-scrambled standard channels only
|
|---|---|
| Dynamic Range | 50 dB |
| Resolution | < 0.5 dB |
| Max Number of Carriers |
14
dependent on favorite channel setup
|
|---|---|
| High/Low Delta Resolution | 0.1 dB |
| Scan | Video, audio, pilot, and digital carriers |
| Minimum Input Level |
0 dBmV
In-service, non-scrambled standard channels only
|
|---|---|
| Range | 0 to 5% |
| Resolution | 0.10% |
| Accuracy | ±0.5% |
| Velocity of Propagation | Adjustable from 60.0 to 99.0% in 0.1% increments |
|---|---|
| Working Distance | Minimum: 755 feet (230 meters) @ VoP of 60.0%; Maximum: 1247 feet (380 meters) @ VoP of 99.0% |
| Amplitude Range | 0 to -80 dBRL |
| Distance Accuracy | 5 feet |
| Modulation |
CW, 16 QAM, 32 QAM, 64 QAM, 128 QAM, 256 QAM, OFDM (4K/8K)
OFDM: DOCSIS 3.1 option equipped meters only
|
|---|---|
| OFDM Subcarrier Modulation |
16 to 4096 QAM, PLC Configurable
DOCSIS 3.1 option equipped meters only
|
| Frequency Range | 5 to 85 MHz |
| Source Width |
CW: 50 kHz; QAM: 6 MHz; OFDM: 6 to 24 MHz
OFDM: DOCSIS 3.1 option equipped meters only
|
| Amplitude |
CW: Adjustable from 10 to 55 dBmV; QAM: Adjustable from 10 to 45 dBmV; OFDM: Adjustable from 10 to 40 dBmV
OFDM: DOCSIS 3.1 option equipped meters only
|
| QAM Symbol Rates | 0.64, 1.28, 2.56, 5.12 MSPS |
| QAM Error Rates | BER: Adjustable from 0 to 1.00E-2; MER: > 38 dB |
| CW Source Accuracy | ±2 dB |
| Finish | UPC and APC |
|---|---|
| Additional Connectors | FC/SC/ST |
| Measurement Range | -50 dBm to +26 dBm |
| Display Resolution | 0.01 dB |
| Tone Detection Range | -30 dBm to +6 dBm |
| Tone Detection | 270 Hz, 330 Hz, 1 kHz, 2 kHz |
| Wavelengths | 1310 nm, 1490 nm, 1550 nm |
| Accuracy | +/-0.5dB > -40 dBm @ 25º C; +/- 1dB < -40 dBm @ 25º C |
| Port Style | FC Style Adapter |
|---|---|
| Fiber Size | 9/125 μm |
| Wavelength | 650 nm |
| Output Power |
3.0 mW
Class III visible red light laser
|
| Pulse Duration | CW (always on) or 2 Hz (0.25 sec pulse) |
| Maximum Radiant Power | < 5.0 mW |
| Turn-On Safety Delay | 2 seconds |
| Construction | Rubber overmolded plastic housing |
|---|---|
| Control | Glow in the dark keypad and LCD touchscreen and/or via a wireless connection to a mobile device such as a laptop, tablet, iPad® or iPhone®, or Android® handset |
| Display |
Color LCD touchscreen, 800 x 480 pixels (approx 4.5" x 2.75")
1G DSP value
|
| Annunciators | Audible annunciator for key strokes |
| Antenna | Internal WiFi antenna, 2 dB gain |
| Flashlight | High-intensity LED (0.25W) |
| Dimensions w/o Case (H x W x D) | 8.6 x 6.1 x 2.00 in (21.84 x 15.94 x 5.08 cm) |
| Dimensions w/ Case (H x W x D) | 9.6 x 7.1 x 3.00 in (24.38 x 18.03 x 7.62 cm) |
| Weight w/o Case |
3.75 lbs (1.70 Kg)
1G DSP value
|
| Weight w/ Case |
4.75 lbs (2.15 Kg)
1G DSP value
|
| Tx Test Port |
75 Ohm Replaceable F-Type Connector
Source Generator Output Transmission Only
|
|---|---|
| Tx/Rx Test Port |
75 Ohm Replaceable F-Type Connector
Upstream and Downstream RF Measurements; DOCSIS 3.1 Modem
|
| Ethernet |
RJ45 Management Port (10/100 Mbps); RJ45 Electrical Test Port (10/100/1000 Base-T); SFP Optical Test Port (100/1000 Base-X)
Electrical and SFP test ports: 1G only
|
| WiFi |
802.11 b/g/n 2.4/5 GHz WiFi Adapter
360 & 1G only
|
| USB | USB 2.0 Type-A Standard Port |
| Operating Time |
12 hours plus, dependent on use
1G DSP value
|
|---|---|
| Charge Time | 4 hours |
| Battery |
Three 2600 mAh @ 7.4V Li-Ion internal batteries, factory replaceable
1G DSP value
|
| Power Adapter | Input: 100 to 240 VAC ~ 50 to 60 Hz, 1.2A Max; Output: 15 VDC, 3.34A |
| Storage | -18° to +50° C (0° to 122° F) |
|---|---|
| Operating Temperature | 0° to +50° C (32° to 122° F) |
| Part Number |
TRI-DSP-1G-D31-VFL-PRO
Plant Maintenance Meter with optical power meter and visual fault locator
|
|---|
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- Cable plant maintenance
- Return spectrum analysis
- Level, C/N, QAM and OFDM measurement
- Channel plan scan with tilt measurement
- DOCSIS 3.0 and 3.1 cable modem service testing
- Ethernet service SLA and QoS verification
- FTTx and passive optical network power measurement
- Fiber patch cord and patch panel fault location
- Upstream ingress troubleshooting
- Coaxial cable fault location
Options & Accessories
| Option | Description |
|---|---|
| TRI-LKG-HL-METER-KIT | Home Leakage Test Kit — Seeker Home Leakage Companion Kit: Seeker HL Source Transmitter, Dual-Band Antenna, Near-Field Probe and Case |
| TRI-DSP-SW-HL-LKG-OPT | DSP Meter Leakage Software Option |
| TRI-ACCY-RF-TEST-CBL | I/O-15 Precision test cable |
| TRI-ISTOP-1000MHZ | I-Stop 1 GHz Test Probe — Ingress troubleshooting probe |
| TRI-ISTOP-1250MHZ | I-Stop Test Probe — Ingress troubleshooting probe |
| TRI-TLB-46-LPF | TLB-46 Return measurement low-pass filter |
| MP-80A | USB Optical Power Meter |
| FBP-P5000i | P5000i USB Fiber Scope |
| TRI-DSP-1G-CASE-REPL | Replacement fitted case |
| TRI-DSP-STRAP-REPL | Replacement shoulder strap |
| TRI-DSP-PWR-ADPT-NEW | Replacement charger (no power cord) |