VIAVI Trilithic DSP Series meters including the 1G DSP plant maintenance meter
VIAVI / DSP Series / Plant Maintenance Meters
1G DSP Sweep

VIAVI Trilithic 1G DSP Sweep Plant Maintenance Meter with Active Sweep

DOCSIS 3.1 plant maintenance meter combining CATV, cable modem, Gigabit Ethernet testing and active forward and return sweep.

Channel Bandwidth
6 MHz and 8 MHz
Amplitude Range
-40 dBmV to +50 dBmV
Modulation Types – Analog
NTSC, PAL B/D/G/H/I/K/N and SECAM B/D/G/H/I/K
Modulation Types – Digital
16/32/64/128/256 QAM Annex A, 64/256 QAM Annex B/C, OFDM 4K/8K
Datasheet

Overview

The VIAVI Trilithic 1G DSP Sweep (part number TRI-DSP-1G-D31-SWEEP) is the active-sweep version of the 1G DSP plant maintenance meter in the DSP Series. It combines CATV measurements, a DOCSIS 3.1 cable modem, Gigabit Ethernet and network testing, and sweep functions in one handheld instrument for system-wide maintenance.

Sweep functions

The Sweep model adds RSA high-resolution return sweep, in which the meter acts as an upstream sweep transmitter working with the 8310 RSA Return SpeedSweep Analyzer in the headend. This is used to troubleshoot micro-reflections and narrow suck-outs while stepping around active channels. The model also supports Forward Active Sweep with the 8300 FST Forward SpeedSweep Transmitter for setting amplifier tilt and gain, SSR high-speed return sweep and SST Compare with the 9581 SST, and cable modem sweep with OFDMA using the internal DOCSIS 3.1 modem.

Cable modem and Ethernet testing

The 1G DSP reaches throughput test speeds of up to a gigabit per second through a dedicated Ethernet test port or the internal cable modem. It runs roundtrip or one-way KPI measurements with constant payload testing for Layer 2 through Layer 4, which supports verification of Ethernet SLA and QoS metrics. The internal modem also provides upstream and downstream channel statistics, OFDM profile analysis, upstream linear distortion measurements and ingress-under-carrier views.

Operation

The meter has a large, high-resolution color touchscreen, pass/fail indicators, autotest apps, remote control through a web browser, and a glow-in-the-dark keypad. Results can be synchronized with StrataSync over Ethernet, DOCSIS or WiFi. An optical power meter with visual fault locator, a TDR and home leakage testing are offered as options or as separate ordering variants.

Key Features

  • Combines CATV, DOCSIS 3.1 cable modem, Gigabit Ethernet and network testing in one meter
  • 1.25 GHz frequency range
  • Auto-discovery of channel plans
  • RSA high-resolution return sweep with the 8310 RSA, tracking up to 643 sweep points
  • Forward Active Sweep with carriers injected by the 8300 FST headend transmitter
  • SSR high-speed return sweep and SST Compare with the 9581 SST
  • Cable modem sweep with OFDMA using the internal DOCSIS 3.1 cable modem
  • Throughput testing up to 1 GbE using a dedicated test port or the internal cable modem
  • Roundtrip or one-way constant payload testing for Layer 2-4 SLA and QoS verification
  • Dual RF test ports and source generator for RF loopback testing
  • Frequency domain reflectometer for distance to cable faults
  • Upstream Traffic Control Plus and downstream QAM Error Vector Spectrum ingress analysis
  • Upstream linear distortion measurements: equalizer taps, group delay, in-channel response
  • Built-in 802.11 b/g/n 2.4/5 GHz WiFi with survey mode
  • Large, high resolution color touchscreen with pass/fail indicators and autotest apps
  • Remote meter control via a web browser
  • Multi-user support for up to 5 technicians
  • StrataSync synchronization over Ethernet, DOCSIS or WiFi
  • Glow in the dark keypad

Specifications

Level Measurement
Channel Bandwidth 6 MHz and 8 MHz
Amplitude Range -40 dBmV to +50 dBmV
Modulation Types – Analog NTSC, PAL B/D/G/H/I/K/N and SECAM B/D/G/H/I/K
Modulation Types – Digital 16/32/64/128/256 QAM Annex A, 64/256 QAM Annex B/C, OFDM 4K/8K
OFDM: DOCSIS 3.1 option equipped meters only
Analog Measurement Accuracy ±0.75 dB @ 77° F (25° C); ±2.0 dB from 0° to +50° C (32° to 122° F)
Digital Measurement Accuracy ±0.75 dB @ 77° F (25° C); ±2.5 dB from 0° to +50° C (32° to 122° F)
Display Resolution 0.1 dB
Spectrum Measurement
Frequency Range – Return Path 4 to 205 MHz
Frequency Range – Forward Path 5 to 1250 MHz
Dual Return Path Diplexers 42 MHz: 4 to 42 MHz; 85 MHz: 4 to 85 MHz
Manually Adjustable Resolution Bandwidth Return Path: 300 kHz; Forward Path: 10, 30, 100, and 300 kHz; 1 and 3 MHz
Auto Ranging Resolution Bandwidth 10 kHz: Span ≤ 3.5 MHz; 30 kHz: Span ≤ 12.0 MHz; 100 kHz: Span ≤ 35.9 MHz; 300 kHz: Span ≤ 300 MHz; 1 MHz: Span ≤ 359.2 MHz; 3 MHz: Span ≥ 359.3 MHz
Display Spans Return Path: 4 to 42 MHz, 4 to 65 MHz, 4 to 85 MHz or 4 to 205 MHz; Forward Path: User-selectable in 1 kHz steps
Display Scale 1, 2, 5, 7.5 or 10 dB/division
Display Range 8 vertical divisions
when marker bar is hidden
Spurious Free Dynamic Range 60 dB
@ 25° C (77° F) (+50 dBmV)
Sensitivity (terminated) Return Path: -40 dBmV (4 to 205 MHz); Forward Path: -40 dBmV (5 to 1250 MHz)
OFDM Channel Spectrum full 24 to 192 MHz OFDM channels
Raw forward and return spectrum traces
Digital Channel Measurement
Deep Interleave Compatibility Yes
Downstream MER 40 ±2 dB @ +6 dBmV RF Input Level; 34 ±2 dB @ -6 dBmV RF Input Level
Downstream BER Method True BER, derived from code words not from MER
Downstream BER Standard ITU J.83 annex A, B, C
Downstream BER Range 1 E-7 to 1 E-9
@ -6 dBmV RF Input Level
Symbol Rates ≥ 2 MSPS; ≤ 6.952 MSPS
Cable Modem Measurement
Protocol Support DOCSIS 1.1 / 2.0 / 3.0 / 3.1; SNMP V1, V2c, V3
DOCSIS 3.1: DOCSIS 3.1 option equipped meters only
Compliance Certificates FCC
CM Diplexer 85 MHz: 5 to 85 MHz
Receiver Frequency (edge to edge) 108 to 1218 MHz
Receiver Channel Bandwidth 6 MHz
Receiver Signal Level -15 to 15 dBmV
DOCSIS 3.0 Demodulation 64 QAM, 256 QAM
DOCSIS 3.0 Downstream Data Rate Up to 1.2 Gbps with 32 downstream channel bonding (DOCSIS 32x8)
DOCSIS 3.1 Demodulation Multi-Carrier OFDM 16 to 4096 QAM
DOCSIS 3.1 option equipped meters only
DOCSIS 3.1 Downstream Data Rate Up to 2.5 Gbps with 2 OFDM 196 MHz Downstream Channels
DOCSIS 3.1 option equipped meters only
Transmitter Frequency (edge to edge) 5 to 85 MHz
Transmitter Signal Level Controlled by CMTS though power ranging function
DOCSIS 3.0 Upstream Modulation QPSK, 8 QAM, 16 QAM, 32 QAM, 64 QAM, and 128 QAM (SCDMA only)
DOCSIS 3.0 Upstream Data Rate Up to 320 Mbps with 8 upstream channels bonding
DOCSIS 3.1 Upstream Modulation Multi-Carrier OFDMA BPSK to 4096 QAM
DOCSIS 3.1 option equipped meters only
DOCSIS 3.1 Upstream Data Rate Up to 1 Gbps with 2 OFDMA 96 MHz Upstream Channels
DOCSIS 3.1 option equipped meters only
Upstream SC-QAM Channels up to eight (8)
Downstream Channels up to 32 downstream SC-QAM channels (DOCSIS 3.0 only); up to two (2) downstream OFDM channels and 30 downstream SC-QAM channels (mixed DOCSIS 3.0 and DOCSIS 3.1)
OFDM: DOCSIS 3.1 option equipped meters only
OFDM Multiple Profile Selection up to four (4) Profiles 0-3 (A-D)
DOCSIS 3.1 option equipped meters only
Carrier-to-Noise, Tilt and Hum
C/N Minimum Input Level for Full Range +10 dBmV
In-service, non-scrambled standard channels only
C/N Dynamic Range 50 dB
C/N Resolution < 0.5 dB
Tilt Max Number of Carriers 14
dependent on favorite channel setup
Tilt High/Low Delta Resolution 0.1 dB
Tilt Scan Video, audio, pilot, and digital carriers
Hum Minimum Input Level 0 dBmV
In-service, non-scrambled standard channels only
Hum Range 0 to 5%
Hum Resolution 0.10%
Hum Accuracy ±0.5%
Sweep
RSA High-Resolution Return Sweep Tracks up to 643 individual sweep points and displays a full sweep on the screen every four seconds
Works with the 8310 RSA Return SpeedSweep Analyzer in the headend
Forward Active Sweep Uses carriers injected into non-active channel spaces by the 8300B FST Forward SpeedSweep Transmitter
Feature matrix lists the companion transmitter as 8300A FST
SSR High-Speed Return Sweep Injects up to eight user-selectable test carriers into the upstream
Measured in the headend by the 9581 SST
SST Compare Simultaneous display of locally measured return path spectrum and spectrum scanned from the headend by the 9581 SST
Cable Modem Sweep with OFDMA Detailed return band sweep using only the internal DOCSIS 3.1 cable modem
DOCSIS 3.1 option equipped meters only
Frequency Domain Reflectometer
Velocity of Propagation Adjustable from 60.0 to 99.0% in 0.1% increments
Working Distance Minimum: 755 feet (230 meters) @ VoP of 60.0%; Maximum: 1247 feet (380 meters) @ VoP of 99.0%
Amplitude Range 0 to -80 dBRL
Distance Accuracy 5 feet
Source Generator
Modulation CW, 16 QAM, 32 QAM, 64 QAM, 128 QAM, 256 QAM, OFDM (4K/8K)
OFDM: DOCSIS 3.1 option equipped meters only
OFDM Subcarrier Modulation 16 to 4096 QAM, PLC Configurable
DOCSIS 3.1 option equipped meters only
Frequency Range 5 to 85 MHz
Source Width CW: 50 kHz; QAM: 6 MHz; OFDM: 6 to 24 MHz
OFDM: DOCSIS 3.1 option equipped meters only
Amplitude CW: Adjustable from 10 to 55 dBmV; QAM: Adjustable from 10 to 45 dBmV; OFDM: Adjustable from 10 to 40 dBmV
OFDM: DOCSIS 3.1 option equipped meters only
QAM Symbol Rates 0.64, 1.28, 2.56, 5.12 MSPS
QAM Error Rates BER: Adjustable from 0 to 1.00E-2; MER: > 38 dB
CW Source Accuracy ±2 dB
Physical
Construction Rubber overmolded plastic housing
Control Glow in the dark keypad and LCD touchscreen and/or via a wireless connection to a mobile device such as a laptop, tablet, iPad® or iPhone®, or Android® handset
Display Color LCD touchscreen, 800 x 480 pixels (approx 4.5” x 2.75”)
Annunciators Audible annunciator for key strokes
Antenna Internal WiFi antenna, 2 dB gain
Flashlight High-intensity LED (0.25W)
Dimensions w/o Case (H x W x D) 8.6 x 6.1 x 2.00 in (21.84 x 15.94 x 5.08 cm)
Dimensions w/ Case (H x W x D) 9.6 x 7.1 x 3.00 in (24.38 x 18.03 x 7.62 cm)
Weight w/o Case 3.75 lbs (1.70 Kg)
Weight w/ Case 4.75 lbs (2.15 Kg)
Interfaces
Tx Test Port 75 Ohm Replaceable F-Type Connector
Source Generator Output Transmission Only
Tx/Rx Test Port 75 Ohm Replaceable F-Type Connector
Upstream and Downstream RF Measurements; DOCSIS 3.1 Modem
Ethernet RJ45 Management Port (10/100 Mbps); RJ45 Electrical Test Port (10/100/1000 Base-T); SFP Optical Test Port (100/1000 Base-X)
WiFi 802.11 b/g/n 2.4/5 GHz WiFi Adapter
USB USB 2.0 Type-A Standard Port
Battery and Power
Operating Time 12 hours plus, dependent on use
Charge Time 4 hours
Battery Three 2600 mAh batteries
Series datasheet: Two 2600 mAh @ 7.4V Li-Ion internal batteries, factory replaceable; 1G DSP uses three
Power Adapter Input: 100 to 240 VAC ~ 50 to 60 Hz, 1.2A Max; Output: 15 VDC, 3.34A
Environmental
Storage -18° to +50° C (0° to 122° F)
Operating Temperature 0° to +50° C (32° to 122° F)
Ordering Information
Part Number TRI-DSP-1G-D31-SWEEP
Plant Maintenance Meter with Active Sweep

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • HFC plant maintenance
  • Forward and return path sweep and alignment
  • Return spectrum analysis
  • Level, C/N, QAM and OFDM measurement
  • Channel plan scan with tilt measurement
  • DOCSIS 3.1 cable modem service testing
  • Ethernet SLA and QoS verification
  • Ingress troubleshooting
  • Cable fault location

Options & Accessories

Option Description
TRI-DSP-SW-HL-LKG-OPT DSP Meter Leakage Software Option
TRI-LKG-HL-METER-KIT Seeker Home Leakage Companion Kit — Seeker HL Source Transmitter, Dual-Band Antenna, Near-Field Probe and Case
TRI-ACCY-RF-TEST-CBL I/O-15 Precision test cable
TRI-ISTOP-1000MHZ I-Stop 1 GHz Test Probe — Ingress troubleshooting probe
TRI-ISTOP-1250MHZ I-Stop Test Probe — Ingress troubleshooting probe
TRI-TLB-46-LPF TLB-46 Return measurement low-pass filter
MP-80A USB Optical Power Meter
FBP-P5000i P5000i USB Fiber Scope
TRI-DSP-1G-CASE-REPL Replacement fitted case
TRI-DSP-STRAP-REPL Replacement shoulder strap
TRI-DSP-PWR-ADPT-NEW Replacement charger (no power cord)