VIAVI Trilithic 1G DSP Pro DOCSIS 3.1 Plant Maintenance Meter
DOCSIS 3.1 plant maintenance meter combining CATV, cable modem, gigabit Ethernet and optical testing with a 1.25 GHz frequency range.
- Channel Bandwidth
- 6 MHz and 8 MHz
- Amplitude Range
- -40 dBmV to +50 dBmV
- Modulation Types (Analog)
- NTSC, PAL B/D/G/H/I/K/N and SECAM B/D/G/H/I/K
- Modulation Types (Digital)
- 16/32/64/128/256 QAM Annex A, 64/256 QAM Annex B/C, OFDM 4K/8K
Overview
The VIAVI Trilithic 1G DSP Pro (part number TRI-DSP-1G-D31-PRO) is the plant maintenance meter of the DSP Series. It combines CATV measurements, a DOCSIS 3.1 cable modem, Gigabit Ethernet testing and optical testing in a single instrument for systemwide maintenance work on cable networks.
The meter provides troubleshooting tools for experienced technicians while simplifying decisions and standardising procedures for less experienced staff through pass/fail indicators and autotest apps. It uses a large, high-resolution color touchscreen, a glow-in-the-dark keypad and supports remote control of the meter via a web browser. A visual fault locator (VFL) is described for locating loss points in patch cords, patch panels and enclosures.
Ethernet and Cable Modem Testing
The 1G DSP can perform throughput testing at speeds of up to a gigabit/sec using a dedicated Ethernet test port or the internal cable modem. Roundtrip or one-way Key Parameter Index (KPI) measurements with constant payload testing for Layer 2 through Layer 4 support verification of Ethernet Service Level Agreement (SLA) and Quality of Service (QoS) metrics. The internal DOCSIS 3.1 modem operates in DOCSIS 3.0 (32x8) and DOCSIS 3.1 modes and reports upstream and downstream channel statistics, OFDM profile statistics and upstream linear distortion measurements.
RF Measurements
The meter measures analog, SC-QAM and OFDM carriers, performs channel plan scans with tilt measurement and channel plan auto discovery, and displays return spectrum from 4 to 205 MHz and forward spectrum from 5 to 1250 MHz. Ingress-under-carrier tools include Upstream Traffic Control Plus and downstream QAM Error Vector Spectrum. Dual RF test ports and a source generator allow RF loopback testing of active and passive devices.
StrataSync
DSP Series meters synchronise with StrataSync, a cloud-based solution that manages assets, configurations and test data, over Ethernet, DOCSIS or WiFi. The StrataSync workflow option allows work orders, test profiles and pass/fail thresholds to be deployed to the meter and results to be uploaded for management review.
Key Features
- Combines CATV, DOCSIS 3.1 cable modem, Gigabit Ethernet and optical testing in one instrument
- 1.25 GHz frequency range
- Throughput testing up to 1 GbE using a dedicated Ethernet test port or the internal cable modem
- Roundtrip or one-way constant payload testing for Layer 2-4 for Ethernet SLA and QoS verification
- SFP optical power measurement with link speed, wavelength, Tx power and Rx power
- Internal DOCSIS 3.1 modem operating in DOCSIS 3.0 (32x8) and DOCSIS 3.1 modes
- OFDM profile statistics, multiple profile selection and distributed MER
- Upstream linear distortion testing: equalizer taps, group delay and in-channel response
- Upstream Traffic Control Plus heat map for ingress under carrier
- Downstream QAM Error Vector Spectrum display
- Frequency domain reflectometer for distance to cable faults
- Dual RF test ports and source generator for CW, QAM and OFDM carriers from 5 to 85 MHz
- Return spectrum 4 to 205 MHz and forward spectrum 5 to 1250 MHz
- Channel plan scan, tilt measurement and channel plan auto discovery
- Network test suite with Ping, VoIP, Throughput and Traceroute
- Built-in 802.11 b/g/n 2.4/5 GHz WiFi adapter with WiFi survey mode
- Multiple user profiles for up to 5 technicians
- Remote access and control from a PC, smart phone or tablet
- Large high-resolution color touchscreen with pass/fail indicators and autotest apps
- Glow in the dark keypad
- Firmware updates via the web or USB
- StrataSync synchronisation via Ethernet, DOCSIS or WiFi
Specifications
| Channel Bandwidth | 6 MHz and 8 MHz |
|---|---|
| Amplitude Range | -40 dBmV to +50 dBmV |
| Modulation Types (Analog) | NTSC, PAL B/D/G/H/I/K/N and SECAM B/D/G/H/I/K |
| Modulation Types (Digital) |
16/32/64/128/256 QAM Annex A, 64/256 QAM Annex B/C, OFDM 4K/8K
OFDM: DOCSIS 3.1 option equipped meters only
|
| Analog Measurement Accuracy | ±0.75 dB @ 77° F (25° C); ±2.0 dB from 0° to +50° C (32° to 122° F) |
| Digital Measurement Accuracy | ±0.75 dB @ 77° F (25° C); ±2.5 dB from 0° to +50° C (32° to 122° F) |
| Display Resolution | 0.1 dB |
| Frequency Range (Return Path) | 4 to 205 MHz |
|---|---|
| Frequency Range (Forward Path) | 5 to 1250 MHz |
| Dual Return Path Diplexers | 42 MHz: 4 to 42 MHz; 85 MHz: 4 to 85 MHz |
| Manually Adjustable Resolution Bandwidth | Return Path: 300 kHz; Forward Path: 10, 30, 100, and 300 kHz; 1 and 3 MHz |
| Auto Ranging Resolution Bandwidth | 10 kHz: Span ≤ 3.5 MHz; 30 kHz: Span ≤ 12.0 MHz; 100 kHz: Span ≤ 35.9 MHz; 300 kHz: Span ≤ 300 MHz; 1 MHz: Span ≤ 359.2 MHz; 3 MHz: Span ≥ 359.3 MHz |
| Display Spans | Return Path: 4 to 42 MHz, 4 to 65 MHz, 4 to 85 MHz or 4 to 205 MHz; Forward Path: User-selectable in 1 kHz steps |
| Display Scale | 1, 2, 5, 7.5 or 10 dB/division |
| Display Range |
8 vertical divisions
when marker bar is hidden
|
| Spurious Free Dynamic Range |
60 dB
@ 25° C (77° F) (+50 dBmV)
|
| Sensitivity (terminated) | Return Path: -40 dBmV (4 to 205 MHz); Forward Path: -40 dBmV (5 to 1250 MHz) |
| Deep Interleave Compatibility | Yes |
|---|---|
| Downstream MER | 40 ±2 dB @ +6 dBmV RF Input Level; 34 ±2 dB @ -6 dBmV RF Input Level |
| Downstream BER Method | True BER, derived from code words not from MER |
| Downstream BER Standard | ITU J.83 annex A, B, C |
| Downstream BER Range |
1 E-7 to 1 E-9
@ -6 dBmV RF Input Level
|
| Symbol Rates | ≥ 2 MSPS; ≤ 6.952 MSPS |
| Protocol Support |
DOCSIS 1.1 / 2.0 / 3.0 / 3.1; SNMP V1, V2c, V3
DOCSIS 3.1: DOCSIS 3.1 option equipped meters only
|
|---|---|
| Compliance Certificates | FCC |
| CM Diplexer | 85 MHz: 5 to 85 MHz |
| Receiver Frequency (edge to edge) | 108 to 1218 MHz |
| Receiver Channel Bandwidth | 6 MHz |
| Receiver Signal Level | -15 to 15 dBmV |
| DOCSIS 3.0 Demodulation | 64 QAM, 256 QAM |
| DOCSIS 3.0 Downstream Data Rate | Up to 1.2 Gbps with 32 downstream channel bonding (DOCSIS 32x8) |
| DOCSIS 3.1 Demodulation |
Multi-Carrier OFDM 16 to 4096 QAM
DOCSIS 3.1 option equipped meters only
|
| DOCSIS 3.1 Downstream Data Rate |
Up to 2.5 Gbps with 2 OFDM 196 MHz Downstream Channels
DOCSIS 3.1 option equipped meters only
|
| Transmitter Frequency (edge to edge) | 5 to 85 MHz |
| Transmitter Signal Level | Controlled by CMTS though power ranging function |
| DOCSIS 3.0 Modulation | QPSK, 8 QAM, 16 QAM, 32 QAM, 64 QAM, and 128 QAM (SCDMA only) |
| DOCSIS 3.0 Upstream Data Rate | Up to 320 Mbps with 8 upstream channels bonding |
| DOCSIS 3.1 Modulation |
Multi-Carrier OFDMA BPSK to 4096 QAM
DOCSIS 3.1 option equipped meters only
|
| DOCSIS 3.1 Upstream Data Rate |
Up to 1 Gbps with 2 OFDMA 96 MHz Upstream Channels
DOCSIS 3.1 option equipped meters only
|
| C/N Minimum Input Level for Full Range |
+10 dBmV
In-service, non-scrambled standard channels only
|
|---|---|
| C/N Dynamic Range | 50 dB |
| C/N Resolution | < 0.5 dB |
| Tilt Max Number of Carriers |
14
dependent on favorite channel setup
|
| Tilt High/Low Delta Resolution | 0.1 dB |
| Tilt Scan | Video, audio, pilot, and digital carriers |
| Hum Minimum Input Level |
0 dBmV
In-service, non-scrambled standard channels only
|
| Hum Range | 0 to 5% |
| Hum Resolution | 0.10% |
| Hum Accuracy | ±0.5% |
| Velocity of Propagation | Adjustable from 60.0 to 99.0% in 0.1% increments |
|---|---|
| Working Distance | Minimum: 755 feet (230 meters) @ VoP of 60.0%; Maximum: 1247 feet (380 meters) @ VoP of 99.0% |
| Amplitude Range | 0 to -80 dBRL |
| Distance Accuracy | 5 feet |
| Modulation |
CW, 16 QAM, 32 QAM, 64 QAM, 128 QAM, 256 QAM, OFDM (4K/8K)
OFDM: DOCSIS 3.1 option equipped meters only
|
|---|---|
| OFDM Subcarrier Modulation |
16 to 4096 QAM, PLC Configurable
DOCSIS 3.1 option equipped meters only
|
| Frequency Range | 5 to 85 MHz |
| Source Width |
CW: 50 kHz; QAM: 6 MHz; OFDM: 6 to 24 MHz
OFDM: DOCSIS 3.1 option equipped meters only
|
| Amplitude |
CW: Adjustable from 10 to 55 dBmV; QAM: Adjustable from 10 to 45 dBmV; OFDM: Adjustable from 10 to 40 dBmV
OFDM: DOCSIS 3.1 option equipped meters only
|
| QAM Symbol Rates | 0.64, 1.28, 2.56, 5.12 MSPS |
| QAM Error Rates | BER: Adjustable from 0 to 1.00E-2; MER: > 38 dB |
| CW Source Accuracy | ±2 dB |
| Throughput Testing Speed | up to 1 GbE using a dedicated test port |
|---|---|
| Test Modes | Roundtrip or one-way constant payload testing for Layer 2-4 |
| Construction | Rubber overmolded plastic housing |
|---|---|
| Control | Glow in the dark keypad and LCD touchscreen and/or via a wireless connection to a mobile device such as a laptop, tablet, iPad® or iPhone®, or Android® handset |
| Display | Color LCD touchscreen, 1G: 800 x 480 pixels (approx 4.5” x 2.75”) |
| Annunciators | Audible annunciator for key strokes |
| Antenna | Internal WiFi antenna, 2 dB gain |
| Dimensions w/o Case (H x W x D) | 8.6 x 6.1 x 2.00 in (21.84 x 15.94 x 5.08 cm) |
| Dimensions w/ Case (H x W x D) | 9.6 x 7.1 x 3.00 in (24.38 x 18.03 x 7.62 cm) |
| Weight w/o Case | 3.75 lbs (1.70 Kg) |
| Weight w/ Case | 4.75 lbs (2.15 Kg) |
| Tx Test Port |
75 Ohm Replaceable F-Type Connector
Source Generator Output Transmission Only
|
|---|---|
| Tx/Rx Test Port |
75 Ohm Replaceable F-Type Connector
Upstream and Downstream RF Measurements, DOCSIS 3.1 Modem
|
| Ethernet Management Port | RJ45 Management Port (10/100 Mbps) |
| Ethernet Electrical Test Port |
RJ45 Electrical Test Port (10/100/1000 Base-T)
1G only
|
| SFP Optical Test Port |
SFP Optical Test Port (100/1000 Base-X)
1G only
|
| WiFi | 802.11 b/g/n 2.4/5 GHz WiFi Adapter |
| USB | USB 2.0 Type-A Standard Port |
| Operating Time | 12 hours plus, dependent on use |
|---|---|
| Charge Time | 4 hours |
| Battery | Two 2600 mAh @ 7.4V Li-Ion internal batteries, factory replaceable (1G DSP, Three 2600 mAh batteries) |
| Power Adapter | Input: 100 to 240 VAC ~ 50 to 60 Hz, 1.2A Max; Output: 15 VDC, 3.34A |
| Storage | -18° to +50° C (0° to 122° F) |
|---|---|
| Operating Temperature | 0° to +50° C (32° to 122° F) |
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- Cable plant maintenance
- Return spectrum analysis
- Level, C/N, QAM and OFDM measurement
- Channel plan scan with tilt measurement
- DOCSIS 3.1 cable modem service testing
- Ethernet SLA and QoS verification
- Upstream ingress troubleshooting
- Coaxial cable fault location
- Home leakage testing
Options & Accessories
| Option | Description |
|---|---|
| TRI-DSP-SW-HL-LKG-OPT | DSP Meter Leakage Software Option |
| TRI-LKG-HL-METER-KIT | Seeker Home Leakage Companion Kit — Seeker HL Source Transmitter, Dual-Band Antenna, Near-Field Probe and Case |
| TRI-ACCY-RF-TEST-CBL | I/O-15 Precision test cable |
| TRI-ISTOP-1000MHZ | I-Stop 1 GHz Test Probe — Ingress troubleshooting probe |
| TRI-ISTOP-1250MHZ | I-Stop Test Probe — Ingress troubleshooting probe |
| TRI-TLB-46-LPF | TLB-46 Return measurement low-pass filter |
| MP-80A | USB Optical Power Meter |
| FBP-P5000i | P5000i USB Fiber Scope |
| TRI-DSP-1G-CASE-REPL | Replacement fitted case |
| TRI-DSP-STRAP-REPL | Replacement shoulder strap |
| TRI-DSP-PWR-ADPT-NEW | Replacement charger (no power cord) |