VIAVI Trilithic DSP Series meters including the 1G DSP plant maintenance meter
VIAVI / DSP Series / Plant Maintenance Meters
1G DSP Pro

VIAVI Trilithic 1G DSP Pro DOCSIS 3.1 Plant Maintenance Meter

DOCSIS 3.1 plant maintenance meter combining CATV, cable modem, gigabit Ethernet and optical testing with a 1.25 GHz frequency range.

Channel Bandwidth
6 MHz and 8 MHz
Amplitude Range
-40 dBmV to +50 dBmV
Modulation Types (Analog)
NTSC, PAL B/D/G/H/I/K/N and SECAM B/D/G/H/I/K
Modulation Types (Digital)
16/32/64/128/256 QAM Annex A, 64/256 QAM Annex B/C, OFDM 4K/8K
Datasheet

Overview

The VIAVI Trilithic 1G DSP Pro (part number TRI-DSP-1G-D31-PRO) is the plant maintenance meter of the DSP Series. It combines CATV measurements, a DOCSIS 3.1 cable modem, Gigabit Ethernet testing and optical testing in a single instrument for systemwide maintenance work on cable networks.

The meter provides troubleshooting tools for experienced technicians while simplifying decisions and standardising procedures for less experienced staff through pass/fail indicators and autotest apps. It uses a large, high-resolution color touchscreen, a glow-in-the-dark keypad and supports remote control of the meter via a web browser. A visual fault locator (VFL) is described for locating loss points in patch cords, patch panels and enclosures.

Ethernet and Cable Modem Testing

The 1G DSP can perform throughput testing at speeds of up to a gigabit/sec using a dedicated Ethernet test port or the internal cable modem. Roundtrip or one-way Key Parameter Index (KPI) measurements with constant payload testing for Layer 2 through Layer 4 support verification of Ethernet Service Level Agreement (SLA) and Quality of Service (QoS) metrics. The internal DOCSIS 3.1 modem operates in DOCSIS 3.0 (32x8) and DOCSIS 3.1 modes and reports upstream and downstream channel statistics, OFDM profile statistics and upstream linear distortion measurements.

RF Measurements

The meter measures analog, SC-QAM and OFDM carriers, performs channel plan scans with tilt measurement and channel plan auto discovery, and displays return spectrum from 4 to 205 MHz and forward spectrum from 5 to 1250 MHz. Ingress-under-carrier tools include Upstream Traffic Control Plus and downstream QAM Error Vector Spectrum. Dual RF test ports and a source generator allow RF loopback testing of active and passive devices.

StrataSync

DSP Series meters synchronise with StrataSync, a cloud-based solution that manages assets, configurations and test data, over Ethernet, DOCSIS or WiFi. The StrataSync workflow option allows work orders, test profiles and pass/fail thresholds to be deployed to the meter and results to be uploaded for management review.

Key Features

  • Combines CATV, DOCSIS 3.1 cable modem, Gigabit Ethernet and optical testing in one instrument
  • 1.25 GHz frequency range
  • Throughput testing up to 1 GbE using a dedicated Ethernet test port or the internal cable modem
  • Roundtrip or one-way constant payload testing for Layer 2-4 for Ethernet SLA and QoS verification
  • SFP optical power measurement with link speed, wavelength, Tx power and Rx power
  • Internal DOCSIS 3.1 modem operating in DOCSIS 3.0 (32x8) and DOCSIS 3.1 modes
  • OFDM profile statistics, multiple profile selection and distributed MER
  • Upstream linear distortion testing: equalizer taps, group delay and in-channel response
  • Upstream Traffic Control Plus heat map for ingress under carrier
  • Downstream QAM Error Vector Spectrum display
  • Frequency domain reflectometer for distance to cable faults
  • Dual RF test ports and source generator for CW, QAM and OFDM carriers from 5 to 85 MHz
  • Return spectrum 4 to 205 MHz and forward spectrum 5 to 1250 MHz
  • Channel plan scan, tilt measurement and channel plan auto discovery
  • Network test suite with Ping, VoIP, Throughput and Traceroute
  • Built-in 802.11 b/g/n 2.4/5 GHz WiFi adapter with WiFi survey mode
  • Multiple user profiles for up to 5 technicians
  • Remote access and control from a PC, smart phone or tablet
  • Large high-resolution color touchscreen with pass/fail indicators and autotest apps
  • Glow in the dark keypad
  • Firmware updates via the web or USB
  • StrataSync synchronisation via Ethernet, DOCSIS or WiFi

Specifications

Level Measurement
Channel Bandwidth 6 MHz and 8 MHz
Amplitude Range -40 dBmV to +50 dBmV
Modulation Types (Analog) NTSC, PAL B/D/G/H/I/K/N and SECAM B/D/G/H/I/K
Modulation Types (Digital) 16/32/64/128/256 QAM Annex A, 64/256 QAM Annex B/C, OFDM 4K/8K
OFDM: DOCSIS 3.1 option equipped meters only
Analog Measurement Accuracy ±0.75 dB @ 77° F (25° C); ±2.0 dB from 0° to +50° C (32° to 122° F)
Digital Measurement Accuracy ±0.75 dB @ 77° F (25° C); ±2.5 dB from 0° to +50° C (32° to 122° F)
Display Resolution 0.1 dB
Spectrum Measurement
Frequency Range (Return Path) 4 to 205 MHz
Frequency Range (Forward Path) 5 to 1250 MHz
Dual Return Path Diplexers 42 MHz: 4 to 42 MHz; 85 MHz: 4 to 85 MHz
Manually Adjustable Resolution Bandwidth Return Path: 300 kHz; Forward Path: 10, 30, 100, and 300 kHz; 1 and 3 MHz
Auto Ranging Resolution Bandwidth 10 kHz: Span ≤ 3.5 MHz; 30 kHz: Span ≤ 12.0 MHz; 100 kHz: Span ≤ 35.9 MHz; 300 kHz: Span ≤ 300 MHz; 1 MHz: Span ≤ 359.2 MHz; 3 MHz: Span ≥ 359.3 MHz
Display Spans Return Path: 4 to 42 MHz, 4 to 65 MHz, 4 to 85 MHz or 4 to 205 MHz; Forward Path: User-selectable in 1 kHz steps
Display Scale 1, 2, 5, 7.5 or 10 dB/division
Display Range 8 vertical divisions
when marker bar is hidden
Spurious Free Dynamic Range 60 dB
@ 25° C (77° F) (+50 dBmV)
Sensitivity (terminated) Return Path: -40 dBmV (4 to 205 MHz); Forward Path: -40 dBmV (5 to 1250 MHz)
Digital Channel Measurement
Deep Interleave Compatibility Yes
Downstream MER 40 ±2 dB @ +6 dBmV RF Input Level; 34 ±2 dB @ -6 dBmV RF Input Level
Downstream BER Method True BER, derived from code words not from MER
Downstream BER Standard ITU J.83 annex A, B, C
Downstream BER Range 1 E-7 to 1 E-9
@ -6 dBmV RF Input Level
Symbol Rates ≥ 2 MSPS; ≤ 6.952 MSPS
Cable Modem Measurement
Protocol Support DOCSIS 1.1 / 2.0 / 3.0 / 3.1; SNMP V1, V2c, V3
DOCSIS 3.1: DOCSIS 3.1 option equipped meters only
Compliance Certificates FCC
CM Diplexer 85 MHz: 5 to 85 MHz
Receiver Frequency (edge to edge) 108 to 1218 MHz
Receiver Channel Bandwidth 6 MHz
Receiver Signal Level -15 to 15 dBmV
DOCSIS 3.0 Demodulation 64 QAM, 256 QAM
DOCSIS 3.0 Downstream Data Rate Up to 1.2 Gbps with 32 downstream channel bonding (DOCSIS 32x8)
DOCSIS 3.1 Demodulation Multi-Carrier OFDM 16 to 4096 QAM
DOCSIS 3.1 option equipped meters only
DOCSIS 3.1 Downstream Data Rate Up to 2.5 Gbps with 2 OFDM 196 MHz Downstream Channels
DOCSIS 3.1 option equipped meters only
Transmitter Frequency (edge to edge) 5 to 85 MHz
Transmitter Signal Level Controlled by CMTS though power ranging function
DOCSIS 3.0 Modulation QPSK, 8 QAM, 16 QAM, 32 QAM, 64 QAM, and 128 QAM (SCDMA only)
DOCSIS 3.0 Upstream Data Rate Up to 320 Mbps with 8 upstream channels bonding
DOCSIS 3.1 Modulation Multi-Carrier OFDMA BPSK to 4096 QAM
DOCSIS 3.1 option equipped meters only
DOCSIS 3.1 Upstream Data Rate Up to 1 Gbps with 2 OFDMA 96 MHz Upstream Channels
DOCSIS 3.1 option equipped meters only
Carrier-to-Noise, Tilt and Hum
C/N Minimum Input Level for Full Range +10 dBmV
In-service, non-scrambled standard channels only
C/N Dynamic Range 50 dB
C/N Resolution < 0.5 dB
Tilt Max Number of Carriers 14
dependent on favorite channel setup
Tilt High/Low Delta Resolution 0.1 dB
Tilt Scan Video, audio, pilot, and digital carriers
Hum Minimum Input Level 0 dBmV
In-service, non-scrambled standard channels only
Hum Range 0 to 5%
Hum Resolution 0.10%
Hum Accuracy ±0.5%
Frequency Domain Reflectometer
Velocity of Propagation Adjustable from 60.0 to 99.0% in 0.1% increments
Working Distance Minimum: 755 feet (230 meters) @ VoP of 60.0%; Maximum: 1247 feet (380 meters) @ VoP of 99.0%
Amplitude Range 0 to -80 dBRL
Distance Accuracy 5 feet
Source Generator
Modulation CW, 16 QAM, 32 QAM, 64 QAM, 128 QAM, 256 QAM, OFDM (4K/8K)
OFDM: DOCSIS 3.1 option equipped meters only
OFDM Subcarrier Modulation 16 to 4096 QAM, PLC Configurable
DOCSIS 3.1 option equipped meters only
Frequency Range 5 to 85 MHz
Source Width CW: 50 kHz; QAM: 6 MHz; OFDM: 6 to 24 MHz
OFDM: DOCSIS 3.1 option equipped meters only
Amplitude CW: Adjustable from 10 to 55 dBmV; QAM: Adjustable from 10 to 45 dBmV; OFDM: Adjustable from 10 to 40 dBmV
OFDM: DOCSIS 3.1 option equipped meters only
QAM Symbol Rates 0.64, 1.28, 2.56, 5.12 MSPS
QAM Error Rates BER: Adjustable from 0 to 1.00E-2; MER: > 38 dB
CW Source Accuracy ±2 dB
Ethernet Service Testing
Throughput Testing Speed up to 1 GbE using a dedicated test port
Test Modes Roundtrip or one-way constant payload testing for Layer 2-4
Physical
Construction Rubber overmolded plastic housing
Control Glow in the dark keypad and LCD touchscreen and/or via a wireless connection to a mobile device such as a laptop, tablet, iPad® or iPhone®, or Android® handset
Display Color LCD touchscreen, 1G: 800 x 480 pixels (approx 4.5” x 2.75”)
Annunciators Audible annunciator for key strokes
Antenna Internal WiFi antenna, 2 dB gain
Dimensions w/o Case (H x W x D) 8.6 x 6.1 x 2.00 in (21.84 x 15.94 x 5.08 cm)
Dimensions w/ Case (H x W x D) 9.6 x 7.1 x 3.00 in (24.38 x 18.03 x 7.62 cm)
Weight w/o Case 3.75 lbs (1.70 Kg)
Weight w/ Case 4.75 lbs (2.15 Kg)
Interfaces
Tx Test Port 75 Ohm Replaceable F-Type Connector
Source Generator Output Transmission Only
Tx/Rx Test Port 75 Ohm Replaceable F-Type Connector
Upstream and Downstream RF Measurements, DOCSIS 3.1 Modem
Ethernet Management Port RJ45 Management Port (10/100 Mbps)
Ethernet Electrical Test Port RJ45 Electrical Test Port (10/100/1000 Base-T)
1G only
SFP Optical Test Port SFP Optical Test Port (100/1000 Base-X)
1G only
WiFi 802.11 b/g/n 2.4/5 GHz WiFi Adapter
USB USB 2.0 Type-A Standard Port
Battery and Power
Operating Time 12 hours plus, dependent on use
Charge Time 4 hours
Battery Two 2600 mAh @ 7.4V Li-Ion internal batteries, factory replaceable (1G DSP, Three 2600 mAh batteries)
Power Adapter Input: 100 to 240 VAC ~ 50 to 60 Hz, 1.2A Max; Output: 15 VDC, 3.34A
Environmental
Storage -18° to +50° C (0° to 122° F)
Operating Temperature 0° to +50° C (32° to 122° F)

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • Cable plant maintenance
  • Return spectrum analysis
  • Level, C/N, QAM and OFDM measurement
  • Channel plan scan with tilt measurement
  • DOCSIS 3.1 cable modem service testing
  • Ethernet SLA and QoS verification
  • Upstream ingress troubleshooting
  • Coaxial cable fault location
  • Home leakage testing

Options & Accessories

Option Description
TRI-DSP-SW-HL-LKG-OPT DSP Meter Leakage Software Option
TRI-LKG-HL-METER-KIT Seeker Home Leakage Companion Kit — Seeker HL Source Transmitter, Dual-Band Antenna, Near-Field Probe and Case
TRI-ACCY-RF-TEST-CBL I/O-15 Precision test cable
TRI-ISTOP-1000MHZ I-Stop 1 GHz Test Probe — Ingress troubleshooting probe
TRI-ISTOP-1250MHZ I-Stop Test Probe — Ingress troubleshooting probe
TRI-TLB-46-LPF TLB-46 Return measurement low-pass filter
MP-80A USB Optical Power Meter
FBP-P5000i P5000i USB Fiber Scope
TRI-DSP-1G-CASE-REPL Replacement fitted case
TRI-DSP-STRAP-REPL Replacement shoulder strap
TRI-DSP-PWR-ADPT-NEW Replacement charger (no power cord)

Documents & Resources