Anritsu MS27201A Remote Spectrum Monitor 9 GHz model, front panel
MS27201A

Anritsu MS27201A (MS2720xA) Remote Spectrum Monitor, 9 kHz to 54 GHz, 19-inch Rack Mount

19-inch 2U rack mount remote spectrum monitor covering 9 kHz to 54 GHz, with IQ capture and streaming and PC-based remote control

Frequency range
9 kHz to 9 GHz
Frequency range
9 kHz to 14 GHz
Frequency range
9 kHz to 20 GHz
Frequency range
9 kHz to 26.5 GHz
Datasheet

Overview

The Anritsu MS27201A Remote Spectrum Monitor is a compact spectrum analyzer in a standard 19-inch wide, 2U tall rack mount case, intended for long-term monitoring of the RF spectrum over a large geographic area. Frequency coverage starts at 9 kHz and extends to 9, 14, 20, 26.5, 32, 43.5 or 54 GHz depending on the frequency option ordered, covering LMR, cellular, satellite and defense electronic bands.

The instrument is designed for continuous operation. A built-in watchdog timer resets the instrument after a software interruption, and after a power failure the unit resumes operation in the state it was in before power was lost. It is powered from a supplied external power block.

Remote control and software

The instrument has no local display and is operated over Ethernet. The Anritsu Remote and Report Tools (ARRT) suite replicates the instrument interface on a PC for remote control, trace monitoring and saving results, and includes a report tool for working with saved measurements and creating PDF reports. A single PC can control multiple MS27201A units on a common network. Full programmatic control is available through SCPI commands over Ethernet.

For automated long-term monitoring, the optional MX280001A Vision software collects spectrum traces from multiple monitors, stores spectrum history in a database and generates alarms on threshold or mask violations.

IQ capture and analysis

IQ data can be captured to internal memory or streamed to a PC via USB, Ethernet or, with the MA25101A IQ Streaming PCIe kit, a PCIe interface. The MX280005A IQ Signal Master software provides post-processing, modulation quality measurements, playback and file conversion of captured IQ data. Options add real-time spectrum analysis, pulse analysis, AM/FM modulation measurements, channel scanning and WCDMA, LTE and 5GNR signal analysis.

Key Features

  • Frequency range options of 9/14/20/26.5/32/43.5/54 GHz
  • 19 inch rack mount case, 2U tall
  • PC application user interface (Anritsu Remote and Report Tools)
  • DANL: -164 dBm (with preamp)
  • TOI: +20 dBm (typical)
  • Analysis bandwidth up to 150 MHz (option dependent)
  • Amplitude range: DANL to +30 dBm
  • Phase noise at 1 GHz: -110 dBc/Hz @ 100 kHz offset (typical)
  • Resolution bandwidth (RBW): 1 Hz to 10 MHz
  • Amplitude accuracy: < 14 GHz ± 1.3 dB (± 0.5 dB, typical)
  • Zero span with 60 ns minimum sweep time
  • IQ capture and streaming via Ethernet, USB and PCIe
  • Real-Time Spectrum Analysis (RTSA) with 2.05 µs POI
  • 5GNR, LTE FDD/TDD and WCDMA modulation quality measurements
  • AM/FM modulation quality measurements
  • Six traces with independent detectors per trace
  • 12 markers and comprehensive limit lines
  • Save traces and alarms on defined events
  • Built-in watchdog timer and auto recovery on power failure
  • Full-band preamplifiers
  • Operation to +55 ºC
  • GNSS receiver option (GPS, GLONASS, Galileo, BeiDou)
  • Built-in PDF report generator
  • Compatible with MX280001A Vision spectrum monitoring software

Specifications

Frequency
Frequency range
MS27201A-0709
9 kHz to 9 GHz
Usable to 0 Hz
Frequency range
MS27201A-0714
9 kHz to 14 GHz
Usable to 0 Hz
Frequency range
MS27201A-0720
9 kHz to 20 GHz
Usable to 0 Hz
Frequency range
MS27201A-0726
9 kHz to 26.5 GHz
Usable to 0 Hz
Frequency range
MS27201A-0732
9 kHz to 32 GHz
Usable to 0 Hz
Frequency range
MS27201A-0743
9 kHz to 43.5 GHz
Usable to 0 Hz
Frequency range
MS27201A-0754
9 kHz to 54 GHz
Usable to 0 Hz
Tuning resolution 1 Hz
Span 10 Hz to max frequency
Frequency reference Internal, GNSS, External
Internal frequency reference aging ± 1.0 x 10–6 per 10 years
Internal frequency reference accuracy ± 3.0 x 10–7 (-10°C ±55°C) plus aging
See GNSS Receiver (Option 31) for improved accuracy
External frequency reference 10 MHz, 10 dBm to +10 dBm
Bandwidth
Analysis bandwidth 22 MHz (standard), 55 MHz (Option 103), 120 MHz (Option 104), 150 MHz (Option 105)
The product web page states 110 MHz analysis bandwidth; the datasheet value is given here
RTSA bandwidth 22 MHz (standard), 55 MHz (Option 103), 120 MHz (Option 104), 150 MHz (Option 105)
Resolution bandwidth (RBW) 1 Hz to 10 MHz
In RTSA, minimum RBW varies by span, max is 40 MHz; 1 Hz to 40 MHz in zero span
RBW selectivity 4:1 nominal (–60 dB / –3 dB)
Video bandwidth (VBW) 0.1 Hz to 10 MHz
1 Hz to 40 MHz in zero span
CISPR bandwidth 200 Hz, 9 kHz, and 120 kHz
Resolution bandwidth when using Quasi-Peak marker function
VBW/average type Linear/Log
Sweep
Manual sweep Maximum sweep time is 3600 s (1 hour)
Sweep points 10 to 10,001 (1001 in zero span)
Sweep rate (non-zero span) 40 GHz/s typical
Full span, RBW = VBW = 3 MHz
Zero span sweep time 60 ns to 3600 s
Zero span sweep time accuracy ±2 %
Spectral Purity – SSB Phase Noise (1 GHz)
10 kHz offset –102 dBc/Hz maximum, –106 dBc/Hz typical
100 kHz offset –106 dBc/Hz maximum, –110 dBc/Hz typical
1 MHz offset –111 dBc/Hz maximum, –116 dBc/Hz typical
10 MHz offset –123 dBc/Hz maximum, –129 dBc/Hz typical
Spurs
Residual spurs, preamp off, <14 GHz –90 dBm, maximum
RF input terminated, 0 dB input attenuation
Residual spurs, preamp off, 14 to 20 GHz –85 dBm, maximum
RF input terminated, 0 dB input attenuation
Residual spurs, preamp off, >20 to 54 GHz –80 dBm, maximum
RF input terminated, 0 dB input attenuation
Residual spurs, preamp on, <14 GHz to 32 GHz –100 dBm, maximum
RF input terminated, 0 dB input attenuation
Residual spurs, preamp on, >32 to 54 GHz –95 dBm, maximum
RF input terminated, 0 dB input attenuation
Input-related spurious –60 dBc typical
–30 dBm input
Amplitude
Dynamic range >106 dB minimum at 2.4 GHz, 2/3 (TOI-DANL) in 1 Hz RBW
Measurement range DANL to +30 dBm
Display range 1 to 15 dB/div in 1 dB steps, ten divisions displayed
Reference level range –150 dBm to +30 dBm
Attenuator resolution 0 to 65 dB, 5 dB steps
Reference level offset 99.9 dB external loss to 99.9 dB external gain
Amplitude units dBm, dBm/m2, dBW/m2
Maximum continuous input (≥10 dB attenuation) +30 dBm peak typical, ± 50 VDC
Maximum continuous input (< 10 dB attenuation) +23 dBm peak typical, ± 50 VDC
Maximum continuous input (preamp on) +10 dBm peak typical, ± 50 VDC
DANL –164 dBm in 1 Hz RBW
With preamp
Amplitude accuracy, 9 kHz to 14 GHz ±1.3 dB maximum, ±0.5 dB typical
20 °C to 30 °C after 30 minute warm-up; 10 dB attenuation, -50 dBm ≤ input ≤ -10 dBm, 1 kHz RBW
Amplitude accuracy, >20 GHz to 54 GHz
MS27201A-0726, MS27201A-0732, MS27201A-0743, MS27201A-0754
±1.8 dB maximum, ±0.5 dB typical
20 °C to 30 °C after 30 minute warm-up; ±2.5 dB maximum at –10 °C to 55 °C after 60 minute warm-up
Distortion and Input
Third-order intercept (TOI), 2.4 GHz +14 dBm minimum
–20 dBm tones 2 MHz apart, 0 dB input attenuation, preamp OFF, reference level –20 dBm
TOI, 50 MHz to < 9 GHz +15 dBm typical
TOI, 9 GHz to 20 GHz +20 dBm typical
TOI, > 20 GHz to 32 GHz +11 dBm typical
TOI, > 32 GHz to 54 GHz +15 dBm typical
P1dB, <4 GHz +5 dBm
Nominal
P1dB, 4 GHz to 20 GHz +12 dBm
Nominal
P1dB, >20 GHz to 32 GHz +7 dBm
Nominal
P1dB, > 32 GHz to 54 GHz +12 dBm
Nominal
Second harmonic distortion, 50 MHz –75 dBc maximum
0 dB input attenuation, –30 dBm input
Second harmonic distortion, < 10 GHz –80 dBc typical
Second harmonic distortion, ≥ 10 GHz –75 dBc typical
VSWR, ≤20 GHz 1.5:1 typical
≥10 dB input attenuation
VSWR, > 20 GHz to 54 GHz 2.0:1 typical
≥10 dB input attenuation
Traces, Markers and Spectrogram
Traces Up to Six Traces
Detector type per trace Peak, RMS/Avg, Negative, Sample, Normal
Markers Up to 12 Markers
Spectrogram number of lines 142
Real-Time Spectrum Analyzer (Option 199)
FFT rate
MS27201A-0199
527,000 FFT/s (normal resolution), 263,000 FFT/s (high resolution)
Minimum detectable signal
MS27201A-0199
5 ns
Persistence
MS27201A-0199
Infinite or Variable from 0 to 10 s
Acquisition time
MS27201A-0199
50 ms to 5 s
Probability of intercept
MS27201A-0199
2.055 µs
Normal density resolution, 55/120/150 MHz analysis bandwidth; 2.520 µs with 22 MHz standard bandwidth
IQ Waveform Capture and Streaming (Options 124/125/126/127)
Maximum sample rate
MS27201A-0124, MS27201A-0126
200 MHz
Option dependent
Maximum signal bandwidth
MS27201A-0124, MS27201A-0126
110 MHz
Option dependent
Bit resolution 8, 10, 16, or 32-bit
Option 126 limits depth to 8 or 10 bits when bandwidth is 110 MHz
Total capture memory 2 GB
Capture mode Single, Continuous, Streaming
Data Out port streaming
MS27201A-0125, MS27201A-0127
Gapless streaming of 150 MHz bandwidth at 16-bit resolution or 100 MHz bandwidth at 32-bit resolution
Requires MA25101A IQ Streaming PCIe kit and compatible PC
USB port streaming (ext4), 8 bit
MS27201A-0125, MS27201A-0127
100 MHz BW, 122.88 MSPS sample rate
Requires USB 3.0 solid state drive
GNSS Receiver (Option 31)
Supported satellite systems
MS27201A-0031
GNSS (includes combinations of GPS, GLONASS, Galileo, Beidou)
High frequency accuracy
MS27201A-0031
< ± 2.5 x 10–8 with GNSS On
3 minutes after satellite lock in selected mode (GPS antenna connected)
Holdover accuracy
MS27201A-0031
<±5.0 x 10–8 24 hour holdover accuracy
–10 °C to 55 °C ambient temperature (GPS antenna disconnected)
Connectors
RF In
MS27201A-0709, MS27201A-0714, MS27201A-0720
Type N(f), 50Ω
RF In
MS27201A-0726, MS27201A-0732, MS27201A-0743
Ruggedized Type K(m), 50Ω
RF In
MS27201A-0754
Ruggedized Type V(m), 50Ω
GPS SMA(f), 50Ω
External power 5.5 mm barrel connector, 14 to 16 VDC, 5.0 A max
Ethernet interface RJ45 connector for Ethernet 10/100/1000 Mbps
Connect to PC or LAN for remote access
USB interface Two USB 3 Type A
Supports file transfer and IQ capture/streaming
External reference in 10 MHz, SMA(f), 50Ω, maximum input +10 dBm
External reference out SMA(f), 50Ω, 10 MHz
External trigger SMA(f), 50Ω, TTL-compatible levels, maximum input +5 VDC
DC bias voltage SMA(f), Voltage Range: +1 V to +34 V, Resolution: 0.1 V, Max Current: 1 A, Max Power: 15 W
General
Instrument memory 8 GB of which nominally 1.5 GB is allocated to the operating system. Available memory to users is nominally 6.5 GB.
Language English, Spanish, Chinese-simplified, Japanese, French, Korean
Control interfaces Ethernet
Programming language Standard Commands for Programmable Instruments (SCPI)
Full instrument programming control (except power on/off) via Ethernet
Continuous operation and recovery Built in watchdog timer and auto recover on power failure provide continuity of service
Warranty Standard three-year warranty
Environmental
Environmental standard MIL-PRF-28800F Class 2
Operating temperature range –10 ºC to 55 ºC
Storage temperature range –51 ºC to 71 ºC
Maximum relative humidity 95 % RH at 30 ºC, non-condensing
Vibration, sinusoidal 5 Hz to 55 Hz
Vibration, random 10 Hz to 500 Hz
Half sine shock 30 gn
Altitude 4600 meters, operating and non-operating
EMC (European Union) 2014/30/EU, EN 61326-1:2021
Safety EN 61010-1:2010
Size and Weight
Size 426 mm x 282 mm x 85 mm, (16.8 in x 11.1 in x 3.3 in)
Weight
MS27201A-0709, MS27201A-0714, MS27201A-0720
6.4 kg (14.10 lb)
Weight
MS27201A-0726, MS27201A-0732, MS27201A-0743, MS27201A-0754
6.74 kg (14.85 lb)

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • Spectrum clearing
  • Shared spectrum monitoring
  • Satellite ground station monitoring
  • Critical site security
  • Interference monitoring at large events
  • Regulatory enforcement
  • Long-term wide area spectrum surveillance
  • Detection of unlicensed or illicit transmitters

Included

  • Certificate of Calibration and Conformance
  • 2000-1371-R Ethernet Cable, 2 m
  • 806-442-R SMA(m) to BNC(m) cable, 1 m (qty 1)
  • 2000-2156-R SMA(m) to BNC(f) Adapter (qty 3)
  • 40-204-R AC/DC Power Adapter

Options & Accessories

Option Description
MS27201A-0709 Frequency Range 9 kHz to 9 GHz
MS27201A-0714 Frequency Range 9 kHz to 14 GHz
MS27201A-0720 Frequency Range 9 kHz to 20 GHz
MS27201A-0726 Frequency Range 9 kHz to 26.5 GHz
MS27201A-0732 Frequency Range 9 kHz to 32 GHz
MS27201A-0743 Frequency Range 9 kHz to 43.5 GHz
MS27201A-0754 Frequency Range 9 kHz to 54 GHz
MS27201A-0006 Remove Wi-Fi and Bluetooth
MS27201A-0007 Secure Data — Prevents storing setup or measurement data to internal storage; data is stored only to external USB memory
MS27201A-0017 Secure Communication — Creates a secure tunnel when connected to a network; ports are closed and data encrypted
MS27201A-0027 Channel Scanner
MS27201A-0031 GPS Receiver — Requires GPS antenna, sold separately
MS27201A-0883 LTE FDD/TDD Measurements — Requires GPS option MS27201A-0031
MS27201A-0888 5GNR FDD/TDD Measurements — Requires GPS option MS27201A-0031
MS27201A-0089 Zero Span IF Output
MS27201A-0090 Gated Sweep
MS27201A-0103 55 MHz Analysis Bandwidth
MS27201A-0104 120 MHz Analysis Bandwidth
MS27201A-0105 150 MHz Analysis Bandwidth
MS27201A-0124 IQ Waveform Capture — Includes MX280005A IQ Signal Master base feature set
MS27201A-0125 IQ Waveform Streaming — Includes MX280005A IQ Signal Master base feature set; requires option 124
MS27201A-0126 IQ Waveform Capture (Non-Export Controlled) — Includes MX280005A IQ Signal Master base feature set
MS27201A-0127 IQ Waveform Streaming (Non-Export Controlled) — Includes MX280005A IQ Signal Master base feature set; requires option 126
MS27201A-0128 Vector Signal Analysis enabled — Requires option 124 or 126
MS27201A-0199 Real-Time Spectrum Analysis (RTSA)
MS27201A-0400 Vision Monitor Enabled
MS27201A-0401 Vision Locate — Requires option MS27201A-0400
MS27201A-0407 Vision High-Speed Port Scanner Enabled
MS27201A-0421 Pulse Analyzer
MS27201A-0509 AM/FM Modulation Measurements
MS27201A-0871 WCDMA FDD Measurements — Requires Option 31
MS27201A-xxxx-0097 Accredited Calibration to ISO17025 and ANSI/NCSL Z540-1 — xxxx is the frequency option number
MS27201A-xxxx-0098 Standard Calibration to ISO17025 and ANSI/NCSL Z540-1 — xxxx is the frequency option number
MS27201A-xxxx-0099 Premium Calibration to ISO17025 and ANSI/NCSL Z540-1 plus test data — xxxx is the frequency option number
MX280005A IQ Signal Master Vector Signal Analysis PC software
MX280001A Remote Spectrum Monitor Vision Software
MX280007A Mobile InterferenceHunter
MA25101A IQ Streaming PCIe Kit — Includes PCIe card with mounting hardware and 2000-2030-R PCIe OCuLink I/O Data Cable; requires Option 125 or Option 127
2000-2185-R GNSS (GPS) antenna, Magnet Mount, SMA(m) with 3 m (9.8 ft) cable — Requires 2.7 VDC to 5 VDC
2000-1760-R Miniature GPS Antenna, SMA(m) — Requires 2.5 VDC to 3.7 VDC
2000-1652-R GPS antenna, Magnet Mount, SMA(m) with 0.3 m (1 ft) cable — Requires 3.3 VDC to 5 VDC
2000-2200-R Broadband antenna, 20 MHz to 21 GHz, N(f), 50Ω

Documents & Resources