VIAVI ONMSi Remote Fiber Test System (RFTS) Optical Network Management System
Remote fiber test and optical network management system that detects, locates and reports fiber faults across core, metro, access and FTTH networks.
- Height
- 1 RU
- Width
- 2/3 rack width 19”, or 21 (ETSI), or 23”
- Depth
- 232 mm
- Operating temperature
- –20 to 50°C
Overview
The VIAVI ONMSi (Optical Network Management System) is a Remote Fiber Test System (RFTS) for core, metro, access and FTTH networks. It supports the management of fiber optic networks through remote fiber testing and fiber plant documentation, detecting and locating fiber degradation and alerting operators and managers with the details of each fault. Measurement schedules allow network operators to assess long-term fiber performance as a basis for asset management. ONMSi is also part of the VIAVI NITRO Fiber Sensing solution.
How an RFTS works
An RFTS is a centralized system that combines fiber optic test heads placed at key network locations. The test heads sweep the fiber with an OTDR test signal to identify and locate fiber faults and degradations. The system can switch across the fiber plant and can also test on demand, for example for construction verification or post-repair verification after a fiber break.
Issues detected
ONMSi tracks fiber degradation, such as crushed or bent fibers causing signal impairment before an outage occurs. Dirty, damaged or disconnected connectors can be seen using the RFTS OTDR. On-demand tests can also switch the OTDR to a specific DWDM wavelength to determine whether a problem lies in the fiber or in an active element such as an OLT or ONT/ONU.
System architecture
The system supports both point-to-point (metro, core, access) and point-to-multipoint (PON) networks up to the ONT. It scales from one to hundreds of test probes, using VIAVI fiber test heads such as the FTH-5000, FTH-7000 and FTH-9000 together with optical switches. ONMSi is a web-based application with multiple APIs and a domain architecture for integration into the operator's organization. The product is also part of the VIAVI Remote PHY turn-up and maintenance solution.
The specifications below cover the fiber test heads and high port density optical switches documented for use with ONMSi.
Key Features
- Large range of test modules and optical switches
- Scalable system from one to hundreds of test probes
- Multiple dashboards for instant network and system diagnostics
- Domain architecture for organizational flexibility
- Alarm notification by e-mail, SMS, Web Services or SNMP; compliant with OSS-J and ITU-X733
- 100% web based in a secure environment
- Single GUI for map and monitoring display
- Detects fiber faults all the way to the subscriber
- Locates faults using associated network landmark information
- 24/7 network monitoring with automatic fault quantification and location
- Supports both P2P (Metro/Core/Access) and P2MP (PON) networks up to the ONT
- Integration via web-enabled application, multiple APIs and domain architecture
Specifications
|
Height
FTH-7000
|
1 RU
typical at 25°C
|
|---|---|
|
Width
FTH-7000
|
2/3 rack width 19”, or 21 (ETSI), or 23” |
|
Depth
FTH-7000
|
232 mm |
|
Operating temperature
FTH-7000
|
–20 to 50°C |
|
Storage temperature
FTH-7000
|
–20 to 60°C |
|
Humidity
FTH-7000
|
5% to 95% without condensing |
|
EMI/ESD
FTH-7000
|
CE Compliant - Class A (EN61326); FCC Part 15 Compliant |
|
Interfaces
FTH-7000
|
1 RJ45 Ethernet 10/100/1000BaseT ports |
|
Media
FTH-7000
|
Solid State Disk, 16GB or higher |
|
Power supply DC
FTH-7000
|
-20 to -60V
With internal switch and 8100 OTDR module
|
|
Power supply AC
FTH-7000
|
100-240 V, 50/60 Hz (AC/DC Converter)
With internal switch and 8100 OTDR module
|
|
Power consumption
FTH-7000
|
35W
With internal switch and 8100 OTDR module
|
|
Port scalability
FTH-7000
|
Up to 816 ports in 2 RU or up to 2304 ports using additional external switches |
|
Number of ports (LC/APC)
FTH-7000
|
4, 8, 12
typical at 25°C
|
|---|---|
|
Number of ports (MPO-12 male + LC/APC extension)
FTH-7000
|
48 + 4 extension ports |
|
Insertion loss, 4, 8, 12 LC/APC ports
FTH-7000
|
< 1.2 dB
Excluding connectors
|
|
Insertion loss, 48 MPO-12 male + 4 LC/APC ports
FTH-7000
|
< 1.2 dB (< 0.6 dB for extension ports)
Excluding connectors
|
|
Return loss with connectors
FTH-7000
|
> 50 dB |
|
Repeatability
FTH-7000
|
± 0.02 dB |
|
Wavelength range
FTH-7000
|
1480-1670 nm |
|
Lifetime
FTH-7000
|
> 2,5 Billion cycles |
|
Laser safety
FTH-7000
|
Class 1
typical at 25°C
|
|---|---|
|
Central wavelength
FTH-7000
|
1650 ± 5 nm
Guaranteed with laser at 10 µs
|
|
Spacing of measurement points
FTH-7000
|
from 4 cm, with up to 512 000 acquisition points |
|
RMS dynamic range
FTH-7000
|
43 dB
Backscattered level extrapolated at fiber origin minus RMS noise level, after 3 minutes of averaging, largest pulsewidth
|
|
Distance range
FTH-7000
|
Up to 360 km |
|
Pulse width
FTH-7000
|
1 ns to 20 µs |
|
Event dead zone
FTH-7000
|
0.3 m
Measured at 1.5 dB below the peak of a non-saturated reflecting event at shortest pulsewidth; up to 40 km, including chromatic dispersion of the laser
|
|
Attenuation dead zone
FTH-7000
|
2 m
Measured at ±0.5 dB on a linear regression from an FC/UPC (-55 dB) reflectance at shortest pulsewidth
|
|
Distance accuracy
FTH-7000
|
± 1 m ±sampling resolution ±distance x 1.10–5 |
|
Height
FTH-9000
|
2 RU
typical at 25°C
|
|---|---|
|
Width
FTH-9000
|
19, 21 (ETSI), or 23” |
|
Depth
FTH-9000
|
280 mm |
|
Operating temperature
FTH-9000
|
–20 to 50°C |
|
Storage temperature
FTH-9000
|
–20 to 60°C |
|
Humidity
FTH-9000
|
95% without condensing |
|
EMI/ESD
FTH-9000
|
CE compliant |
|
Interfaces
FTH-9000
|
2 RJ45 Ethernet 10/100/1000BaseT ports |
|
Power supply DC
FTH-9000
|
-48V
With internal switch and 8100 OTDR module
|
|
Power supply AC
FTH-9000
|
100-240 V, 50/60 Hz (AC/DC Converter)
With internal switch and 8100 OTDR module
|
|
Power consumption
FTH-9000
|
35W
With internal switch and 8100 OTDR module
|
|
Port scalability
FTH-9000
|
Up to 4464 ports using additional external switches |
|
Standard hardware warranty
FTH-9000
|
1 year
Up to 5 years of extended hardware warranty or an ONMSi System annual maintenance contract can be added
|
|
Number of ports (SC/APC)
FTH-9000
|
4,8,12,16,24
typical at 25°C
|
|---|---|
|
Number of ports (LC/APC)
FTH-9000
|
36,48 |
|
Number of ports (MPO-12)
FTH-9000
|
288, 576 |
|
Insertion loss, up to 48 SC/APC or LC/APC ports
FTH-9000
|
0.6 dB
Excluding connectors
|
|
Insertion loss, 288,576 MPO ports
FTH-9000
|
<2.9 dB
Excluding connectors
|
|
Back-reflection
FTH-9000
|
–60 dB |
|
Repeatability
FTH-9000
|
±0.01 dB |
|
Wavelength range, up to 48 SC/APC or LC/APC ports
FTH-9000
|
1260–1670 nm |
|
Wavelength range, 288,576 MPO ports
FTH-9000
|
1480-1670 nm |
|
Lifetime, SC/APC and LC/APC ports
FTH-9000
|
100 millions cycles |
|
Lifetime, 288, 576 (MPO-12)
FTH-9000
|
> 2,5 billion cycles |
|
Compatible OTDR modules
FTH-9000
|
8100-series plug-in module, 4100-series plug-in module, single or multiple wavelengths, FiberComplete, Tunable DWDM, Fiber Sensing (DTS, DTSS) |
|
Height
FTH-5000
|
1 RU
typical at 25°C
|
|---|---|
|
Width
FTH-5000
|
19, 21 (ETSI), or 23” |
|
Depth
FTH-5000
|
260 mm (ETSI) 280 mm (19 - or 23”) |
|
Standard operating temperature
FTH-5000
|
–5 to 50°C |
|
Extended operating temperature option
FTH-5000
|
–20 to 60°C |
|
Storage temperature
FTH-5000
|
–20 to 60°C |
|
Humidity
FTH-5000
|
95% without condensing |
|
Interfaces
FTH-5000
|
1 RJ45 Ethernet 10/100/1000BaseT ports |
|
Power supply consumption
FTH-5000
|
–36 to –59V 10W |
|
Certifications
FTH-5000
|
NEBS and AT&T ATT-TP-76200 Compliant |
|
Integrated switch number of ports
FTH-5000
|
1, 4, 8, 16 or 48 |
|
Integrated switch insertion loss
FTH-5000
|
< 1.2dB
Excluding connectors
|
|
Integrated switch return loss with connectors
FTH-5000
|
> 50 dB |
|
Integrated switch connector type
FTH-5000
|
LCAPC up to 16 ports, MPO-12 (male) for 48 ports |
|
OTDR number of data points
FTH-5000
|
Up to 512,000 |
|
OTDR sampling resolution
FTH-5000
|
From 4 cm |
|
OTDR distance range
FTH-5000
|
Up to 260 km |
|
OTDR distance accuracy
FTH-5000
|
±1 m ±sampling resolution ±distance x 1.10–5 |
|
OTDR pulse width
FTH-5000
|
5 ns to 20 μs |
|
Integrated switch number of ports
OTU-5000
|
2, 4, 8, 16 or 48
typical at 25°C
|
|---|---|
|
Power supply consumption
OTU-5000
|
–36 to –59V 10W |
|
Standard operating temperature
OTU-5000
|
–5 to 50°C |
|
OTDR distance range
OTU-5000
|
Up to 260 km |
|
Dimensions
E98OSX144
|
Height: 1RU (44mm); Width: 19”; Depth: 183.2, 197.8 or 274.7mm according to brackets positions
typical at 25°C
|
|---|---|
|
Operating temperature
E98OSX144
|
-5 to 50° C |
|
Storage temperature
E98OSX144
|
–20 to 85° C |
|
Interfaces
E98OSX144
|
RS485 |
|
Power consumption in active mode
E98OSX144
|
<0.7 W |
|
Number of ports
E98OSX144
|
144 plus one common port |
|
Operating wavelength range
E98OSX144
|
C-Band, L-Band, and U-Band ranges |
|
Insertion loss with one pair of connectors
E98OSX144
|
<2.9 dB |
|
Return loss with connectors
E98OSX144
|
>50 dB |
|
Repeatability
E98OSX144
|
+/-0.05 dB |
|
Durability
E98OSX144
|
1 Billion switch times |
|
Connector type
E98OSX144
|
LC/APC |
|
Cascading
E98OSX144
|
Cascade up to 31 switches to increase the switch capacity to 4464 fibers |
|
Dimensions
E9H-X36LCAPC, E9H-X48MPO, E9H-X96MPO, E9H-X144MPO, E9H-X192MPO
|
Designed for 1/3 width 1RU (44 mm); Depth: 223.10 mm; Height: 42.50 mm; Length: 146 mm
typical at 25°C
|
|---|---|
|
Weight
E9H-X36LCAPC, E9H-X48MPO, E9H-X96MPO, E9H-X144MPO, E9H-X192MPO
|
<1.4 kg |
|
Operating temperature
E9H-X36LCAPC, E9H-X48MPO, E9H-X96MPO, E9H-X144MPO, E9H-X192MPO
|
-20°C to +60°C |
|
Humidity
E9H-X36LCAPC, E9H-X48MPO, E9H-X96MPO, E9H-X144MPO, E9H-X192MPO
|
5% to 90% without condensing |
|
EMI/ESD
E9H-X36LCAPC, E9H-X48MPO, E9H-X96MPO, E9H-X144MPO, E9H-X192MPO
|
EN 61326-1 :2013 compliant, class A; FCC 47CFR Part 15: 2017 compliant, class A |
|
Interfaces
E9H-X36LCAPC, E9H-X48MPO, E9H-X96MPO, E9H-X144MPO, E9H-X192MPO
|
RS485 |
|
Power consumption in active mode
E9H-X36LCAPC, E9H-X48MPO, E9H-X96MPO, E9H-X144MPO, E9H-X192MPO
|
<0.5 W |
|
Power consumption in low power mode
E9H-X36LCAPC, E9H-X48MPO, E9H-X96MPO, E9H-X144MPO, E9H-X192MPO
|
<0.2 W |
|
Number of ports
E9H-X36LCAPC, E9H-X48MPO, E9H-X96MPO, E9H-X144MPO, E9H-X192MPO
|
36 LC/APC, 48, 96, 144, 192 ports + one common port |
|
Operating wavelength range
E9H-X36LCAPC, E9H-X48MPO, E9H-X96MPO, E9H-X144MPO, E9H-X192MPO
|
1270 nm - 1670 nm |
|
Insertion loss, 36, 48 ports
E9H-X36LCAPC, E9H-X48MPO
|
< 1.2 dB from 1600 nm to 1670 nm; < 1.6 dB from 1528 nm to 1600 nm; < 1.9 dB from 1500 nm to 1528 nm; < 2.1 dB from 1480 nm to 1500 nm
Excluding connectors
|
|
Insertion loss, 96, 144, 192 ports
E9H-X96MPO, E9H-X144MPO, E9H-X192MPO
|
< 1.8 dB from 1600 nm to 1670 nm; <2.6 dB from 1528 nm to 1600 nm; <3.2 dB from 1500 nm to 1528 nm; < 3.6 dB from 1480 nm to 1500 nm
Excluding connectors
|
|
Return loss with connectors
E9H-X36LCAPC, E9H-X48MPO, E9H-X96MPO, E9H-X144MPO, E9H-X192MPO
|
>50 dB |
|
Repeatability
E9H-X36LCAPC, E9H-X48MPO, E9H-X96MPO, E9H-X144MPO, E9H-X192MPO
|
- 0.05 dB to + 0.05 dB |
|
Durability
E9H-X36LCAPC, E9H-X48MPO, E9H-X96MPO, E9H-X144MPO, E9H-X192MPO
|
2.5 Billion cycles |
|
Connector type
E9H-X36LCAPC, E9H-X48MPO, E9H-X96MPO, E9H-X144MPO, E9H-X192MPO
|
Common port: LC/APC; Output ports: LC/APC (36), MPO-12 male (48/96/144/192) |
|
Cascading
E9H-X36LCAPC, E9H-X48MPO, E9H-X96MPO, E9H-X144MPO, E9H-X192MPO
|
Cascade up to 31 switches to support up to 5952 fibers |
|
Compatibility
E9H-X36LCAPC, E9H-X48MPO, E9H-X96MPO, E9H-X144MPO, E9H-X192MPO
|
Compatible with OTU-5000, FTH-5000, FTH-7000, FTH-9000 |
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- Optical network troubleshooting for P2P and P2MP networks
- SLA management
- Network security and intrusion detection
- Network construction testing and test record keeping
- Optical network performance visibility
- Fiber health (temperature and strain) and optical performance monitoring for submarine cable networks
- FTTH and PON networks
- Metro, core and access fiber networks
Options & Accessories
| Option | Description |
|---|---|
| E97-ONMSILINUX | FTH-7000 Software for ONMSI under LINUX |
| E9-ONMSILXFTHLC | Software for ONMSi under LINUX for the PER FTH License Model |
| E98OSX144 | 144 Ports Optical Switch |
| E9H-X36LCAPC | High Density Optical switch 36 ports LCAPC Connectors |
| E9H-X48MPO | High Density Optical Switch of 48 ports MPO-12 Connectors |
| E9H-MPO48-LOCK | MPO Connector locker for UOS 48 ports MPO bloc |
| E9H-X96MPO | High Density Optical Switch of 96 ports MPO-12 Connectors |
| E9H-MPO96-LOCK | MPO Connector locker for UOS 96 ports MPO bloc |
| E9H-X144MPO | High Density Optical Switch of 144 ports MPO-12 Connectors |
| E9H-X192MPO | High Density Optical Switch of 192 ports MPO-12 Connectors |
| E9H-X96MPO-PAYG | Initial Config. with 48 ports for 96 ports High Density Optical switch |
| E9H-X144MPO-PAYG | Initial Config. with 72 ports for 144 ports High Density Optical switch |
| E9H-X192MPO-PAYG | Initial Config. with 96 ports for 192 ports High Density Optical switch |
| E9H-XMOD12-PAYG | Additional 12 ports switch for 96/144/192 ports High Density Optical switch |
| E9H-XMOD12-PAYG-UPG | SW Lic. for adding 12 ports to 96/144/192 ports High Density Optical switch |