SmartClass Fiber OLS-85 Inspection-Ready Handheld Optical Light Source
Handheld inspection-ready optical light source with singlemode and multimode wavelength versions for fiber link loss testing.
- Type
- Class 1 laser product (IEC 60825-1:2007)
- Wavelengths
- 1310, 1550 nm
- Wavelengths
- 850, 1300 nm; 1310, 1550 nm
- Wavelengths
- 1310, 1490, 1550, 1625 nm
Overview
The VIAVI SmartClass Fiber OLS-85 is a compact handheld optical light source used for fiber-optic network qualification and certification. It works with the SmartClass Fiber OLP-85 and OLP-85P optical power meters to run automatic loss tests.
The OLS-85 comes in several versions with different wavelength combinations. They are suited to link loss testing and to characterizing long-haul, metro and access telecommunication networks, and also to data center and local area network testing.
The instrument has a 3.5-in color touch screen with an integrated stylus. Pass/fail analysis uses individual threshold settings. Fiber inspection with automated pass/fail analysis is available with the optional P5000i microscope. Inspection images and test results are stored on the instrument with a time stamp. Data transfer and remote control work over USB or Ethernet.
With VIAVI optical power meters, the source supports auto-lambda and multi-lambda test functions. The housing is rugged and weather-proof, and interchangeable Senko optical adapters fit FC, SC, ST and LC connectors.
Key Features
- Battery-operated field-portable optical light sources in different versions with multimode and singlemode wavelengths
- Interchangeable optical adapters (Senko) for FC, SC, ST and LC optical connectors
- 3.5-in color touch screen with integrated stylus
- Individual threshold settings for pass/fail analysis
- Onboard fiber inspection and test results storage with time stamp
- Data transfer and remote control via USB or Ethernet interface
- Auto-lambda and multi-lambda test functions in combination with VIAVI optical power meters
- Automated pass/fail fiber inspection analysis with the optional P5000i microscope
- Compact, rugged, weather-proof design
Specifications
| Type | Class 1 laser product (IEC 60825-1:2007) |
|---|---|
|
Wavelengths
2313/01
|
1310, 1550 nm |
|
Wavelengths
2313/05
|
850, 1300 nm; 1310, 1550 nm
SM+MM quad source
|
|
Wavelengths
2313/06, 2313/26
|
1310, 1490, 1550, 1625 nm |
|
Wavelengths
2313/22
|
1310, 1550, 1625 nm |
|
Wavelength accuracy
2313/01, 2313/06, 2313/26, 2313/22
|
± 20 nm |
|
Wavelength accuracy
2313/05
|
-20 / +40 nm (850, 1300 nm); ± 20 nm (1310, 1550 nm) |
|
FWHM spectral width
2313/01, 2313/06, 2313/26, 2313/22
|
< 5 nm |
|
FWHM spectral width
2313/05
|
< 170 nm (850, 1300 nm); < 5 nm (1310, 1550 nm) |
|
Output level
2313/01
|
Typ. -3 dBm |
|
Output level
2313/05
|
Typ. -25 dBm (850, 1300 nm); Typ. -3 dBm (1310, 1550 nm) |
|
Output level
2313/06, 2313/26, 2313/22
|
Typ. -6 dBm |
| Short term stability | ± 0.02 dB within 15 min |
| Long term stability | ± 0.2 dB within 8 hrs. |
|
Optical connectors
2313/01, 2313/05, 2313/06
|
1x SC/PC |
|
Optical connectors
2313/26, 2313/22
|
1x SC/APC |
| Display |
High contrast 3.5” color LCD touch screen (4:3 ration)
Typical at 25 °C
|
|---|---|
| Fiber inspection |
Via external P-5000i or via patch cord microscope (P-variants)
Patch cord microscope applies to SmartClass Fiber P-variants only
|
| Data storage | 10,000 results |
|---|---|
| Data download capability | Via USB interface |
| Remote control capability | Via USB or Ethernet |
| Electrical interfaces | 2x USB-A, 1x micro-USB, 1x Ethernet |
| Wireless interfaces | WiFi or Bluetooth |
| Dry batteries | 8x Mignon (AA) Alkaline 1.5 V |
|---|---|
| Battery pack | 1x Li-ion pack 3.7 V |
| AC operation | Via Universal Power Adapter |
| EMI/ESD | CE compliant |
|---|---|
| Recommended calibration interval | 3 years |
| Operating temperature | -10 to +55°C (14 to 122°F) |
| Storage temperature | -20 to +70°C (-4 to 158°F) |
| Dimensions (H x W x D) |
208 x 112 x 64 mm (8.2 x 4.4 x 2.5 in)
Stand alone
|
|---|---|
| Weight |
750 g (1.6 lbs.)
Stand alone
|
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- Fiber insertion loss measurement with a VIAVI OLP-3x or OLP-8x optical power meter
- Inspection of optical connectors (IBYC)
- In-service loss testing
- Long-haul, metro and access telecommunication network characterization
- Data center and local area network testing
Included
- Instrument
- Soft shoulder case
- Quick start guide and safety instructions
- Alkaline batteries
Options & Accessories
| Option | Description |
|---|---|
| 2313/01 | OLS-85 - SM Source 1310/1550 nm SC mounted FC enclosed |
| 2313/05 | OLS-85 - SM+MM Quad Source 850/1300/1310/1550 nm SC mounted FC enclosed |
| 2313/06 | OLS-85 - SM Source 1310/1490/1550/1625 nm SC mounted FC enclosed |
| 2313/22 | OLS-85 - SM Source 1310/1550/1625 nm SC/APC mounted FC enclosed |
| 2313/26 | OLS-85 - SM Source 1310/1490/1550/1625 nm SC/APC mounted FC enclosed |
| 2313/90.01 | Calibration Report for OLS-85 |
| 2327/90.01 | WiFi adapter spare |
| 2327/90.02 | Bluetooth adapter spare |
| 2155/00.06 | Switchable Optical Adapter SC/PC |
| 2155/00.26 | Switchable Optical Adapter SC/APC |
| 2155/00.05 | Switchable Optical Adapter FC/PC FC/APC |
| 2155/00.07 | Switchable optical adapter LC/PC LC/APC |
| 2155/00.27 | Switchable optical adapter LC/APC |
| 2155/00.32 | Switchable Optical Adapter ST/PC |
| 2229/90.01 | 2x Alkaline batteries Mignon AA-Size LR6 — Four of this item are required for one SmartClass Fiber instrument, i.e. a total of 8 batteries |
| 2305/90.02 | Rechargeable Battery Pack |
| 2305/90.04 | Rechargeable Battery Pack with Power Supply |
| 2305/90.01 | Power Supply |
| FITP-UC4 | Carrier For Displays Without PCM |
| 2128/03 | Soft Shoulder Case for 1 instrument |
| 2128/04 | Soft Shoulder Case for up to 4 instruments |
| FBP-SD101 | P5000i digital analysis microscope with 4 tips |