VIAVI CAA06M cable and antenna analyzer module with CellAdvisor 5G
VIAVI / Series · Cable and Antenna Analyzers

VIAVI CAA06M 6 GHz Cable and Antenna Analyzer Modules for CellAdvisor 5G and OneAdvisor 800

Compact 6 GHz modular cable and antenna analyzers for CellAdvisor 5G and OneAdvisor 800, used to verify cell site feed lines and antennas.

Frequency range
12.5 MHz to 6 GHz
Frequency resolution
1 kHz
Frequency accuracy
±2.5 ppm
Aging per year
±1 ppm
View Models Datasheet

Overview

The VIAVI CAA06M CAA Modules are compact modular cable and antenna analyzers covering 12.5 MHz to 6 GHz. They install on the CellAdvisor 5G (CA5000) and OneAdvisor 800 platforms and are used to characterize and verify cell site installations.

Most problems in mobile networks occur in cell site infrastructure such as antennas, cables, amplifiers, filters, connectors, combiners and jumpers. Combined with the test functions of the host platform, the modules support cell site technicians in installation verification and maintenance.

The modules characterize and verify feed line systems and verify antenna or sector-to-sector isolation. Standard modes include reflection, distance to fault, 1-port cable loss and phase, cable delay, Smith chart and CAA Check; 2-port transmission and RF source are optional software modes.

Two versions are available: the CAA06MA module, and the CAA06MB module with bias power and an external bias-tee. CellAdvisor 5G users require the CA5000-DMC dual module carrier; modules are auto-detected by the main instrument when mounted to the carrier.

Models in this series

Model Description
CAA06MA
VIAVI CAA06MA 6 GHz Cable and Antenna Analyzer Module for CellAdvisor 5G and OneAdvisor 800
Compact 12.5 MHz to 6 GHz cable and antenna analyzer module for the VIAVI CellAdvisor 5G and OneAdvisor 800 platforms.
Details →
CAA06MB
VIAVI CAA06MB 6 GHz Cable and Antenna Analyzer Module with Bias Power and External Bias-Tee
6 GHz cable and antenna analyzer module with bias power and external bias-tee for the VIAVI CellAdvisor 5G and OneAdvisor 800 platforms.
Details →

Key Features

  • Auto file naming that eliminates manual inputs in file name
  • Trace overlay that detects signal degradation over time
  • Dual display and multiple tabs that allow fast and efficient measurements
  • Intuitive pass/fail analysis that instantly notifies a problem
  • Integrated RF CW source
  • EZ-Cal calibration that calibrates faster and easier
  • CAA Check, TPA and Job Manager that enable test process automation and consolidated reports
  • Onboard report generation in .pdf
  • StrataSync cloud service and JDViewer PC post-processing

Specifications

Frequency
Frequency range 12.5 MHz to 6 GHz
Frequency resolution 1 kHz
Frequency accuracy ±2.5 ppm
@25°C
Aging per year ±1 ppm
Data points 126, 251, 501, 1001, 2001
Measurement bandwidth 10 kHz
Measurement Accuracy after OSL Calibration
Corrected directivity > 42 dB
Reflection uncertainty ±(0.3 + |20log (1 + 10^(-EP/20))|)
typical; EP = directivity – measured return loss
Measurement Accuracy after EZ-Cal Calibration
Corrected directivity > 38 dB (≤ 4 GHz); > 33 dB (> 4 GHz)
Reflection uncertainty (≤ 4 GHz) ±(0.3 + |20log (1 + 10^(-EP/20))|)
typical; EP = directivity – measured return loss
Reflection uncertainty (> 4 GHz) ±(1 + |20log (1 + 10^(-EP/20))|)
typical; EP = directivity – measured return loss
Output and Input Levels
Output power 0 dBm
nominal
Maximum input level, average continuous power 23 dBm
nominal
Maximum input level, DC voltage ±50 V DC
Interference immunity, on channel 15 dBm @ ≥ 1.3 MHz
Interference immunity, on frequency 15 dBm within 100 kHz
Distance to Fault (DTF)
Measurement speed 0.5 ms per data point
Vertical VSWR range 1 to 65
Vertical VSWR resolution 0.01
Vertical return loss range 0 to 60 dB
Vertical return loss resolution 0.01 dB
Horizontal range 0 to (# of data points – 1) x horizontal resolution; Maximum = 1500 m (4921 ft)
Horizontal resolution (1.5 x 10^8) x (VP)/ΔF
VP = propagation velocity; ΔF = stop frequency – start frequency (Hz)
Reflection
Measurement speed 0.5 ms per data point
VSWR range 1 to 65
VSWR resolution 0.01
Return loss range 0 to 60 dB
Return loss resolution 0.01 dB
1-Port Cable Loss and Phase
Cable loss measurement range 0 to -30 dB
Cable loss resolution 0.01 dB
Phase measurement range -180 to +180°
Phase resolution 0.01°
Smith chart impedance 50 Ω
Smith chart resolution 0.01
2-Port Transmission
Output power range -30 to +5 dBm
typical
Output power step 1 dB
Scalar measurement speed 3.8 ms typical on CellAdvisor 5G; 6.3 ms typical on OneAdvisor 800
Dynamic range 110 dB typical @average 5 for ≤ 4.5 GHz; 105 dB typical @average 5 for > 4.5 GHz
Measurement range -120 to +100 dB
Resolution 0.01 dB
Bias Voltage
Voltage range
CAA06MB
+12 to +30 V DC, 6 W max.
Bias power is provided on the module with bias power port
Voltage resolution
CAA06MB
1 V
Current
CAA06MB
500 mA
RF CW Source
Frequency range 400 MHz to 6 GHz (tunable down to 13 MHz)
Frequency step 1 MHz
Output power range -30 to +10 dBm
Output power step 1 dB
Output power accuracy ±1.5 dB
for 20 to 30°C
Ports
Reflection/RF out port connector type Type-N, female
Reflection/RF out port impedance 50 Ω
nominal
Reflection/RF out port damage level 30 dBm max.; ±50 V DC max.
nominal
Bias voltage port connector type
CAA06MB
SMA, female
For connecting to an external bias-tee device
Bias voltage port impedance
CAA06MB
50 Ω
nominal
Power
Input 19 V DC
Power consumption 6.2 W
for CAA06M only, without using external bias-tee
Size and Weight
Size (W x H x D) 130 x 138 x 41 mm (5.12 x 5.43 x 1.65 inch)
Weight
CAA06MA
0.43 kg (0.95 lb)
for CAA06M module without bias power port
Weight
CAA06MB
0.45 kg (0.99 lb)
for CAA06M module with bias power port
Environmental
Operating temperature -10 to 55°C (14 to 131°F)
Storage temperature -40 to 70°C (-40 to 158°F)
Maximum humidity 95% RH, non-condensing
Shock MIL-PRF-28800F Class 2
Vibration MIL-PRF-28800F Class 2
Transit drop MIL-PRF-28800F Class 2
Regulatory Compliance
Safety EN 61010-1:2010, UL 61010-1:2012, CAN/CSA-C22.2 No. 61010-1:2012
EMC IEC/EN 61326-1:2013, IEC/EN 61326-2-1:2013, CISPR 11:2015 +A1:2016, KN 11, IEC/EN 61000-4-2/3/4/5/6/11, KN 61000-4-2/3/4/5/6/11
RoHS Compliant
Recommended calibration cycle 2 years
CAA06M Module
Measurement Modes and Features
Standard modes Reflection VSWR, Reflection Return Loss, DTF VSWR, DTF Return Loss, 1 Port Cable Loss, 1 Port Phase, Cable Delay, Smith Chart, CAA Check
Optional modes 2 Port Transmission, RF Source
Measurement display Single, dual horizontal, or dual vertical display; Up to 6 independent measurement tabs
Trace Trace overlay, trace math; Trace zoom and up to 4 zoom zones
Alt DTF band Available for DTF measurements only
Marker Up to 6 markers; 3 marker types: normal, delta, and delta pair
Peak/valley search Peak/valley search, peak/valley between markers
Limit Single limit line, multi segment limit line, limit window
Calibration type 1 Port: Standard OSL, EZ-Cal, and Quick; 2 Port: Thru
Report generation Onboard report generation in .pdf
Cloud service StrataSync
Post-processing JDViewer PC application
File save Auto file naming

Applications

  • Cell site installation verification
  • Cell site maintenance
  • Feed line characterization and verification
  • Antenna isolation verification
  • Sector-to-sector isolation verification
  • Distance to fault location
  • GPS cable delay measurement

Options & Accessories

Option Description
CA5000-DMC Dual Module Carrier with Dummy Module for CellAdvisor 5G — Includes C10-DMC and C2K-EMPTYMOD; required for CA5000 CellAdvisor 5G users
CAA06M-CR CAA module calibration report
CAA06M-CRISO CAA module calibration report per ISO 17025
CA5000-S005/ONA-CAA-2P 2 Port transmission measurement — Software option on CellAdvisor 5G/OneAdvisor 800
CA5000-S006/ONA-CAA-RFS RF CW source — Software option on CellAdvisor 5G/OneAdvisor 800
JD78050507 Dual port Type-N 6 GHz calibration kit — Includes JD78050509 Y-calibration kit (1), G700050530 RF Cable (2), and G700050575 RF Adapter (2)
JD78050508 Dual port DIN 6 GHz calibration kit — Includes JD78050510 Y-calibration kit (1), G710050536 RF Cable (2), and G700050572 RF Adapter (2)
JD78050509 Y-Calibration kit, Type-N(m), DC to 6 GHz, 50 Ω — Included in JD78050507
JD78050510 Y-Calibration kit, DIN(m), DC to 6 GHz, 50 Ω — Included in JD78050508
JD70050509 EZ-Cal kit, Type-N(m), DC to 6 GHz, 50 Ω
G700050530 RF cable DC to 8 GHz Type-N(m) to Type-N(m), 1.0 m — Included in JD78050507
G700050531 RF cable DC to 8 GHz Type-N(m) to Type-N(f), 1.5 m
G700050532 RF cable DC to 8 GHz Type-N(m) to Type-N(f), 3.0 m
G710050536 RF cable DC to 6 GHz Type-N(m) to DIN(f), 1.5 m — Included in JD78050508
G700050540 Phase-stable RF cable w grip DC to 6 GHz Type-N(m) to Type-N(f), 1.5 m
G700050541 Phase-stable RF cable w grip DC to 6 GHz Type-N(m) to DIN(f), 1.5 m
G700050571 Adapter Type-N(m) to DIN(f), DC to 7.5 GHz, 50 Ω
G700050572 Adapter DIN(m) to DIN(m), DC to 7.5 GHz, 50 Ω — Included in JD78050508
G700050573 Adapter Type-N(m) to SMA(f) DC to 18 GHz, 50 Ω
G700050574 Adapter Type-N(m) to BNC(f), DC to 4 GHz, 50 Ω
G700050575 Adapter Type-N(f) to Type-N(f), DC to 18 GHz 50 Ω — Included in JD78050507
G700050576 Adapter Type-N(m) to DIN(m), DC to 7.5 GHz, 50 Ω
G700050577 Adapter Type-N(f) to DIN(f), DC to 7.5 GHz, 50 Ω
G700050578 Adapter Type-N(f) to DIN(m), DC to 7.5 GHz, 50 Ω
G700050579 Adapter DIN(f) to DIN(f), DC to 7.5 GHz, 50 Ω
G700050580 Adapter Type-N(m) to Type-N(m), DC to 11 GHz 50 Ω
G700050581 Adapter N(m) to QMA(f), DC to 6.0 GHz, 50 Ω
G700050582 Adapter N(m) to QMA(m), DC to 6.0 GHz, 50 Ω
G700050583 Adapter N(m) to 4.1/9.5 MINI DIN(f), DC to 6.0 GHz, 50 Ω
G700050584 Adapter N(m) to 4.1/9.5 MINI DIN(m), DC to 6.0 GHz, 50 Ω
G700050585 Adapter N(m) to 4.3-10(f), DC to 6.0 GHz, 50 Ω
G700050586 Adapter N(m) to 4.3-10(m), DC to 6.0 GHz, 50 Ω
G700050587 Adapter N(f) to SMA(f), DC to 18 GHz, 50 Ω
G710050581 Attenuator 40 dB, 100 W, DC to 4 GHz (unidirectional)
G700050653 Bias-Tee, N(m), N(f), BNC(f), 2.5 to 6000 MHz, 1W with 250 mm BNC(m) to SMA(m) Cable — Included in CAA06MB

Documents & Resources