VIAVI CAA06M 6 GHz Cable and Antenna Analyzer Modules for CellAdvisor 5G and OneAdvisor 800
Compact 6 GHz modular cable and antenna analyzers for CellAdvisor 5G and OneAdvisor 800, used to verify cell site feed lines and antennas.
- Frequency range
- 12.5 MHz to 6 GHz
- Frequency resolution
- 1 kHz
- Frequency accuracy
- ±2.5 ppm
- Aging per year
- ±1 ppm
Overview
The VIAVI CAA06M CAA Modules are compact modular cable and antenna analyzers covering 12.5 MHz to 6 GHz. They install on the CellAdvisor 5G (CA5000) and OneAdvisor 800 platforms and are used to characterize and verify cell site installations.
Most problems in mobile networks occur in cell site infrastructure such as antennas, cables, amplifiers, filters, connectors, combiners and jumpers. Combined with the test functions of the host platform, the modules support cell site technicians in installation verification and maintenance.
The modules characterize and verify feed line systems and verify antenna or sector-to-sector isolation. Standard modes include reflection, distance to fault, 1-port cable loss and phase, cable delay, Smith chart and CAA Check; 2-port transmission and RF source are optional software modes.
Two versions are available: the CAA06MA module, and the CAA06MB module with bias power and an external bias-tee. CellAdvisor 5G users require the CA5000-DMC dual module carrier; modules are auto-detected by the main instrument when mounted to the carrier.
Models in this series
| Model | Description | |
|---|---|---|
| CAA06MA |
VIAVI CAA06MA 6 GHz Cable and Antenna Analyzer Module for CellAdvisor 5G and OneAdvisor 800
Compact 12.5 MHz to 6 GHz cable and antenna analyzer module for the VIAVI CellAdvisor 5G and OneAdvisor 800 platforms. |
Details → |
| CAA06MB |
VIAVI CAA06MB 6 GHz Cable and Antenna Analyzer Module with Bias Power and External Bias-Tee
6 GHz cable and antenna analyzer module with bias power and external bias-tee for the VIAVI CellAdvisor 5G and OneAdvisor 800 platforms. |
Details → |
Key Features
- Auto file naming that eliminates manual inputs in file name
- Trace overlay that detects signal degradation over time
- Dual display and multiple tabs that allow fast and efficient measurements
- Intuitive pass/fail analysis that instantly notifies a problem
- Integrated RF CW source
- EZ-Cal calibration that calibrates faster and easier
- CAA Check, TPA and Job Manager that enable test process automation and consolidated reports
- Onboard report generation in .pdf
- StrataSync cloud service and JDViewer PC post-processing
Specifications
| Frequency range | 12.5 MHz to 6 GHz |
|---|---|
| Frequency resolution | 1 kHz |
| Frequency accuracy |
±2.5 ppm
@25°C |
| Aging per year | ±1 ppm |
| Data points | 126, 251, 501, 1001, 2001 |
| Measurement bandwidth | 10 kHz |
| Corrected directivity | > 42 dB |
|---|---|
| Reflection uncertainty |
±(0.3 + |20log (1 + 10^(-EP/20))|)
typical; EP = directivity – measured return loss |
| Corrected directivity | > 38 dB (≤ 4 GHz); > 33 dB (> 4 GHz) |
|---|---|
| Reflection uncertainty (≤ 4 GHz) |
±(0.3 + |20log (1 + 10^(-EP/20))|)
typical; EP = directivity – measured return loss |
| Reflection uncertainty (> 4 GHz) |
±(1 + |20log (1 + 10^(-EP/20))|)
typical; EP = directivity – measured return loss |
| Output power |
0 dBm
nominal |
|---|---|
| Maximum input level, average continuous power |
23 dBm
nominal |
| Maximum input level, DC voltage | ±50 V DC |
| Interference immunity, on channel | 15 dBm @ ≥ 1.3 MHz |
| Interference immunity, on frequency | 15 dBm within 100 kHz |
| Measurement speed | 0.5 ms per data point |
|---|---|
| Vertical VSWR range | 1 to 65 |
| Vertical VSWR resolution | 0.01 |
| Vertical return loss range | 0 to 60 dB |
| Vertical return loss resolution | 0.01 dB |
| Horizontal range | 0 to (# of data points – 1) x horizontal resolution; Maximum = 1500 m (4921 ft) |
| Horizontal resolution |
(1.5 x 10^8) x (VP)/ΔF
VP = propagation velocity; ΔF = stop frequency – start frequency (Hz) |
| Measurement speed | 0.5 ms per data point |
|---|---|
| VSWR range | 1 to 65 |
| VSWR resolution | 0.01 |
| Return loss range | 0 to 60 dB |
| Return loss resolution | 0.01 dB |
| Cable loss measurement range | 0 to -30 dB |
|---|---|
| Cable loss resolution | 0.01 dB |
| Phase measurement range | -180 to +180° |
| Phase resolution | 0.01° |
| Smith chart impedance | 50 Ω |
| Smith chart resolution | 0.01 |
| Output power range |
-30 to +5 dBm
typical |
|---|---|
| Output power step | 1 dB |
| Scalar measurement speed | 3.8 ms typical on CellAdvisor 5G; 6.3 ms typical on OneAdvisor 800 |
| Dynamic range | 110 dB typical @average 5 for ≤ 4.5 GHz; 105 dB typical @average 5 for > 4.5 GHz |
| Measurement range | -120 to +100 dB |
| Resolution | 0.01 dB |
|
Voltage range
CAA06MB |
+12 to +30 V DC, 6 W max.
Bias power is provided on the module with bias power port |
|---|---|
|
Voltage resolution
CAA06MB |
1 V |
|
Current
CAA06MB |
500 mA |
| Frequency range | 400 MHz to 6 GHz (tunable down to 13 MHz) |
|---|---|
| Frequency step | 1 MHz |
| Output power range | -30 to +10 dBm |
| Output power step | 1 dB |
| Output power accuracy |
±1.5 dB
for 20 to 30°C |
| Reflection/RF out port connector type | Type-N, female |
|---|---|
| Reflection/RF out port impedance |
50 Ω
nominal |
| Reflection/RF out port damage level |
30 dBm max.; ±50 V DC max.
nominal |
|
Bias voltage port connector type
CAA06MB |
SMA, female
For connecting to an external bias-tee device |
|
Bias voltage port impedance
CAA06MB |
50 Ω
nominal |
| Input | 19 V DC |
|---|---|
| Power consumption |
6.2 W
for CAA06M only, without using external bias-tee |
| Size (W x H x D) | 130 x 138 x 41 mm (5.12 x 5.43 x 1.65 inch) |
|---|---|
|
Weight
CAA06MA |
0.43 kg (0.95 lb)
for CAA06M module without bias power port |
|
Weight
CAA06MB |
0.45 kg (0.99 lb)
for CAA06M module with bias power port |
| Operating temperature | -10 to 55°C (14 to 131°F) |
|---|---|
| Storage temperature | -40 to 70°C (-40 to 158°F) |
| Maximum humidity | 95% RH, non-condensing |
| Shock | MIL-PRF-28800F Class 2 |
| Vibration | MIL-PRF-28800F Class 2 |
| Transit drop | MIL-PRF-28800F Class 2 |
| Safety | EN 61010-1:2010, UL 61010-1:2012, CAN/CSA-C22.2 No. 61010-1:2012 |
|---|---|
| EMC | IEC/EN 61326-1:2013, IEC/EN 61326-2-1:2013, CISPR 11:2015 +A1:2016, KN 11, IEC/EN 61000-4-2/3/4/5/6/11, KN 61000-4-2/3/4/5/6/11 |
| RoHS | Compliant |
| Recommended calibration cycle |
2 years
CAA06M Module |
| Standard modes | Reflection VSWR, Reflection Return Loss, DTF VSWR, DTF Return Loss, 1 Port Cable Loss, 1 Port Phase, Cable Delay, Smith Chart, CAA Check |
|---|---|
| Optional modes | 2 Port Transmission, RF Source |
| Measurement display | Single, dual horizontal, or dual vertical display; Up to 6 independent measurement tabs |
| Trace | Trace overlay, trace math; Trace zoom and up to 4 zoom zones |
| Alt DTF band | Available for DTF measurements only |
| Marker | Up to 6 markers; 3 marker types: normal, delta, and delta pair |
| Peak/valley search | Peak/valley search, peak/valley between markers |
| Limit | Single limit line, multi segment limit line, limit window |
| Calibration type | 1 Port: Standard OSL, EZ-Cal, and Quick; 2 Port: Thru |
| Report generation | Onboard report generation in .pdf |
| Cloud service | StrataSync |
| Post-processing | JDViewer PC application |
| File save | Auto file naming |
Applications
- Cell site installation verification
- Cell site maintenance
- Feed line characterization and verification
- Antenna isolation verification
- Sector-to-sector isolation verification
- Distance to fault location
- GPS cable delay measurement
Options & Accessories
| Option | Description |
|---|---|
| CA5000-DMC | Dual Module Carrier with Dummy Module for CellAdvisor 5G — Includes C10-DMC and C2K-EMPTYMOD; required for CA5000 CellAdvisor 5G users |
| CAA06M-CR | CAA module calibration report |
| CAA06M-CRISO | CAA module calibration report per ISO 17025 |
| CA5000-S005/ONA-CAA-2P | 2 Port transmission measurement — Software option on CellAdvisor 5G/OneAdvisor 800 |
| CA5000-S006/ONA-CAA-RFS | RF CW source — Software option on CellAdvisor 5G/OneAdvisor 800 |
| JD78050507 | Dual port Type-N 6 GHz calibration kit — Includes JD78050509 Y-calibration kit (1), G700050530 RF Cable (2), and G700050575 RF Adapter (2) |
| JD78050508 | Dual port DIN 6 GHz calibration kit — Includes JD78050510 Y-calibration kit (1), G710050536 RF Cable (2), and G700050572 RF Adapter (2) |
| JD78050509 | Y-Calibration kit, Type-N(m), DC to 6 GHz, 50 Ω — Included in JD78050507 |
| JD78050510 | Y-Calibration kit, DIN(m), DC to 6 GHz, 50 Ω — Included in JD78050508 |
| JD70050509 | EZ-Cal kit, Type-N(m), DC to 6 GHz, 50 Ω |
| G700050530 | RF cable DC to 8 GHz Type-N(m) to Type-N(m), 1.0 m — Included in JD78050507 |
| G700050531 | RF cable DC to 8 GHz Type-N(m) to Type-N(f), 1.5 m |
| G700050532 | RF cable DC to 8 GHz Type-N(m) to Type-N(f), 3.0 m |
| G710050536 | RF cable DC to 6 GHz Type-N(m) to DIN(f), 1.5 m — Included in JD78050508 |
| G700050540 | Phase-stable RF cable w grip DC to 6 GHz Type-N(m) to Type-N(f), 1.5 m |
| G700050541 | Phase-stable RF cable w grip DC to 6 GHz Type-N(m) to DIN(f), 1.5 m |
| G700050571 | Adapter Type-N(m) to DIN(f), DC to 7.5 GHz, 50 Ω |
| G700050572 | Adapter DIN(m) to DIN(m), DC to 7.5 GHz, 50 Ω — Included in JD78050508 |
| G700050573 | Adapter Type-N(m) to SMA(f) DC to 18 GHz, 50 Ω |
| G700050574 | Adapter Type-N(m) to BNC(f), DC to 4 GHz, 50 Ω |
| G700050575 | Adapter Type-N(f) to Type-N(f), DC to 18 GHz 50 Ω — Included in JD78050507 |
| G700050576 | Adapter Type-N(m) to DIN(m), DC to 7.5 GHz, 50 Ω |
| G700050577 | Adapter Type-N(f) to DIN(f), DC to 7.5 GHz, 50 Ω |
| G700050578 | Adapter Type-N(f) to DIN(m), DC to 7.5 GHz, 50 Ω |
| G700050579 | Adapter DIN(f) to DIN(f), DC to 7.5 GHz, 50 Ω |
| G700050580 | Adapter Type-N(m) to Type-N(m), DC to 11 GHz 50 Ω |
| G700050581 | Adapter N(m) to QMA(f), DC to 6.0 GHz, 50 Ω |
| G700050582 | Adapter N(m) to QMA(m), DC to 6.0 GHz, 50 Ω |
| G700050583 | Adapter N(m) to 4.1/9.5 MINI DIN(f), DC to 6.0 GHz, 50 Ω |
| G700050584 | Adapter N(m) to 4.1/9.5 MINI DIN(m), DC to 6.0 GHz, 50 Ω |
| G700050585 | Adapter N(m) to 4.3-10(f), DC to 6.0 GHz, 50 Ω |
| G700050586 | Adapter N(m) to 4.3-10(m), DC to 6.0 GHz, 50 Ω |
| G700050587 | Adapter N(f) to SMA(f), DC to 18 GHz, 50 Ω |
| G710050581 | Attenuator 40 dB, 100 W, DC to 4 GHz (unidirectional) |
| G700050653 | Bias-Tee, N(m), N(f), BNC(f), 2.5 to 6000 MHz, 1W with 250 mm BNC(m) to SMA(m) Cable — Included in CAA06MB |