Network Master MU909060A3 Gigabit Ethernet Module with Two SFP Slots
Gigabit Ethernet module with two SFP slots for the MT9090A Network Master, for field installation and troubleshooting of Ethernet links.
- Interface configuration
- Gigabit Ethernet Module with two SFP ports. Two electrical or optical modules can be installed
- Electrical interfaces
- 10/100/1000 Mbps RJ 45 (10BASE-T, 100BASE-TX, 1000BASE-T)
- Optical interfaces
- 100 or 1000 Mbps LC connector (100BASE-FX, 100BASE-LX, 1000BASE-SX, 1000BASE-LX or 1000BASE-ZX)
- Duplex modes
- Full duplex. Electrical 10/100 Mbps also half duplex
Overview
The Anritsu MU909060A3 is a Gigabit Ethernet module for the MT9090A Network Master mainframe. It has two SFP slots, so two electrical or optical SFP modules can be installed. With the module fitted, the compact, battery-powered Network Master tests Gigabit Ethernet links during installation, maintenance and troubleshooting. It covers bandwidth verification, connectivity testing and service availability verification.
The instrument is built for field use. It is ready to measure in about 15 seconds and runs up to 3 hours on a single charge, depending on configuration and setup. It has no fans or vents, and a 4.3-inch wide screen colour display that can be read indoors and outdoors. A Test Automator sets up sequences of tests, and PASS/FAIL indicators and graphical result displays make the results easier to read.
Network activation
For installation, commissioning and QoS verification, the module generates traffic, including VLAN-tagged traffic, and provides BER testing, performance statistics and QoS statistics. Optional RFC 2544 and ITU-T Y.1564 test suites automate throughput, frame loss, latency and jitter testing. Y.1564 runs in two phases: a Service Configuration Test and a Service Performance Test, in which all configured traffic streams run at the same time. In end-to-end mode, two units work together in an in-band control setup, and both sets of results are shown on the master instrument.
Maintenance and troubleshooting
Both ports can be used at the same time. This cuts test time when deploying multiple ports and allows pass-through and bidirectional monitoring. The Channel Stats option monitors up to 63 filtered streams to identify error streams, top talkers and network attacks. The Remote GUI option lets an operator control the instrument from a Web browser through a USB-Ethernet converter. Test results can be exported as PDF or CSV reports.
Key Features
- Two SFP slots accepting two electrical or optical SFP modules
- Two ports work simultaneously, including pass through test and in-line monitoring test
- Ping test and traceroute test
- Option for automated ITU-T Y.1564 testing of multiple simultaneous traffic streams
- Option for automated RFC 2544 testing including end-to-end testing
- Stacked VLAN (Q-in-Q), MPLS, IPv4, IPv6 supported
- Test Automator simplifies operation and ensures proper set-up
- Channel Stats option identifies error streams, top talkers and network attacks
- Service disruption time measurement for VoIP and IPTV
- Optical power level check for physical layer testing
- Pass/Fail identification and graphical result display
- PDF and CSV report generation for documentation of test results
- 4.3-inch high resolution, widescreen color display readable indoors and outdoors
- Ready for measurement in about 15 seconds
- Up to 3 hours of testing on a single charge
- Rugged design with no fans or vents
- Modular platform
- Compact and lightweight design for field portability
Specifications
| Interface configuration | Gigabit Ethernet Module with two SFP ports. Two electrical or optical modules can be installed |
|---|---|
| Electrical interfaces |
10/100/1000 Mbps RJ 45 (10BASE-T, 100BASE-TX, 1000BASE-T)
Via G0246A RJ-45 SFP
|
| Optical interfaces | 100 or 1000 Mbps LC connector (100BASE-FX, 100BASE-LX, 1000BASE-SX, 1000BASE-LX or 1000BASE-ZX) |
| Duplex modes | Full duplex. Electrical 10/100 Mbps also half duplex |
| Test configurations | Monitor/Generate, Pass through, Reflector |
| Supported encapsulations | EtherType II (DIX v.2), IEEE 802.3 with 802.2 (LLC1), IEEE 802.3 with SNAP |
|
1000BASE-SX 850 nm Multi Mode min. input sensitivity and wavelength
G0240A
|
–17 dBm 770 nm to 860 nm
Correct functioning can only be guaranteed with optical modules from Anritsu for the MU909060A
|
|---|---|
|
1000BASE-SX 850 nm Multi Mode output power and wavelength
G0240A
|
–9.5 to –1.5 dBm 830 nm to 860 nm |
|
1000BASE-LX 1310 nm Single Mode min. input sensitivity and wavelength
G0241A
|
–20 dBm 1260 nm to 1580 nm |
|
1000BASE-LX 1310 nm Single Mode output power and wavelength
G0241A
|
–10 to –3 dBm 1285 nm to 1343 nm |
|
1000BASE-ZX 1550 nm Single Mode min. input sensitivity and wavelength
G0242A
|
–22 dBm 1260 nm to 1580 nm |
|
1000BASE-ZX 1550 nm Single Mode output power and wavelength
G0242A
|
–3 to +5 dBm 1480 nm to 1580 nm |
|
100BASE-FX 1310 nm Multi Mode min. input sensitivity and wavelength
G0243A
|
–31 dBm 1260 nm to 1570 nm |
|
100BASE-FX 1310 nm Multi Mode output power and wavelength
G0243A
|
–20 to –14 dBm 1270 nm to 1335 nm |
|
100BASE-LX 1310 nm Single Mode min. input sensitivity and wavelength
G0244A
|
–28 dBm 1260 nm to 1570 nm |
|
100BASE-LX 1310 nm Single Mode output power and wavelength
G0244A
|
–15 to –8 dBm 1261 nm to 1360 nm |
| Line rate | Variable line rate traffic generation, up to full line rate |
|---|---|
| Traffic shaping | Constant, Burst, Ramped |
| Frame sizes | Constant, Stepped or Random length |
| Adjustable frame size | 46 to 10,000 bytes |
| Addressing | Configurable MAC/IP source and destination addresses (supports IPv4 and IPv6), UDP/TCP address and DSCP/TOS byte |
|
VLAN
MU909060A3-003
|
User defined up to 3 level VLAN ID and VLAN priority
Option
|
|
MPLS
MU909060A3-004
|
User defined up to 3 level MPLS label
Option
|
| Test result (current/cumulative) | Total frame, Total bit, Utilization, Throughput, Broadcast frame, Error frame, Frame loss, Frame loss rate |
| Graph | Tx utilization, Tx throughput, Rx utilization, Rx throughput, Error frame |
| Service Disruption Time | Min, Max, Average, Count, Total time, Total SDT (%), Last frame received (interval) timestamp |
|
Channel Stats
MU909060A3-006
|
Total frame, Total bit, Error, Frame size distribution of up to 63 filtered streams
Option
|
| BER test patterns | FOX, all 0, all 1, 0101, PING, PRBS 9, PRBS 11, PRBS 15, PRBS 20, PRBS 23, PRBS 29, PRBS 31, HF test pattern, CRPAT, JTPAT, SPAT |
|---|---|
| BER pattern generation | Unframed, Framed with IP header or Framed with IP and TCP/UDP header |
| Ping test | Round Trip Time (RTT), Supports IPv4 and IPv6 addressing, Answer incoming Ping requests (On/Off) |
| Traceroute test result | Number of hop, Host IP address, Number of Received/Lost replies, Min/Max/Average time |
|
ITU-T Y.1564 test
MU909060A3-007
|
Configuration Test: Up to 32 services, Up to 6 steps with CBS, EBS; Service Performance Test: Up to 32 services
Option; test report Y.1564 Appendix II compliant (CSV or PDF)
|
|
RFC 2544 tests
MU909060A3-001
|
Throughput and utilization, Frame loss, Latency, Packet jitter, Back-to-back frames (burstability)
Option; single ended and Switch/Router test modes
|
|
Multistream test
MU909060A3-002
|
Up to 8 streams can be activated on the Ethernet line
Option
|
| HTTP/FTP test result | Received/Total file size, Min/Max/Average throughput |
| Reflector delay |
2.44 μs @1000 Mbps, 5.16 μs @100 Mbps, 31.93 μs @10 Mbps
Maximum internal delay when instrument is in reflector configuration
|
| Internal memory |
40 MB
For storage of results, setups and screen shots
|
|---|---|
| Service interface | Two USB 1.1 (One type A for USB memory stick, One type B for USB mass storage) |
| Display | 4.3-inch color LCD (480 × 272 pixels), with LED back light, transmissive |
| Language | English, Japanese, Chinese (Simplified, Traditional), Spanish, German, Korean, French, Italian, Portuguese |
| Battery |
Dedicated battery pack or 4 AA Ni-MH
Operating time: Up to 3 hours, depending on configuration and test setup; Charging time: 4 hours while power off (typ.)
|
| Power supply | AC adapter: 9 V(dc), 100 V(ac) to 240 V(ac), Frequency: 50 Hz/60 Hz |
| Dimensions and mass |
190 (W) × 96 (H) × 30 (D) mm, <600 g
MU909060A1/A2/A3
|
| Operational temperature range | 0° to +40°C, humidity ≤85%, No condensation |
|---|---|
| Storage temperature range | –25° to +60°C, humidity ≤80%, No condensation |
| Vibration | IEC 60 068-2-6 Fc and IEC 60 068-2-64 Fh |
| Ingress protection rating | IEC60529 IP51 |
| Laser safety | IEC 60825-1: 2014 CLASS 1 |
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- Gigabit Ethernet installation and commissioning
- Ethernet maintenance and troubleshooting
- QoS verification
- Carrier class Ethernet
- Mobile backhaul testing
- Multiple port network installation
- VoIP and IPTV service disruption testing
Included
- W3173AE Gigabit Ethernet Tester Quick Start Guide
- Z1234A Network Master Gigabit Ethernet Tester CD
Options & Accessories
| Option | Description |
|---|---|
| MU909060A3-001 | RFC 2544 Test (for MU909060A3) — Including End-To-End testing with master/slave control |
| MU909060A3-002 | Multistream (for MU909060A3) — Up to 8 streams simultaneous testing |
| MU909060A3-003 | Stacked VLAN (for MU909060A3) — Up to 3 levels tagged VLAN support |
| MU909060A3-004 | MPLS (for MU909060A3) — Up to 3 MPLS labels support |
| MU909060A3-005 | Remote GUI (for MU909060A3) — Controlling MT9090A via Web browser. Requires J1480A USB-Ethernet Converter (sold separately) |
| MU909060A3-006 | Channel Stats (for MU909060A3) — Analyzing error streams, top talkers, network attacks |
| MU909060A3-007 | Y.1564 Test (for MU909060A3) — New methodology to reduce testing time |
| MU909060A3-301 | RFC 2544 Test Retrofit (for MU909060A3) |
| MU909060A3-302 | Multistream Retrofit (for MU909060A3) |
| MU909060A3-303 | Stacked VLAN Retrofit (for MU909060A3) |
| MU909060A3-304 | MPLS Retrofit (for MU909060A3) |
| MU909060A3-305 | Remote GUI Retrofit (for MU909060A3) — Requires J1480A USB-Ethernet Converter (sold separately) |
| MU909060A3-306 | Channel Stats Retrofit (for MU909060A3) |
| MU909060A3-307 | Y.1564 Test Retrofit (for MU909060A3) |
| G0240A | 1000 Mbps SX SFP — 850 nm multimode, LC connector (optical) |
| G0241A | 1000 Mbps LX SFP — 1310 nm single mode, LC connector (optical) |
| G0242A | 1000 Mbps ZX SFP — 1550 nm single mode, LC connector (optical) |
| G0243A | 100 Mbps FX SFP — 1310 nm multimode, LC connector (optical) |
| G0244A | 100 Mbps LX SFP — 1310 nm single mode, LC connector (optical) |
| G0246A | 10/100/1000 Mbps RJ-45 SFP (electrical) |
| MU909060A3-ES210 | 2 Years Extended Warranty Service (for MU909060A3) |
| MU909060A3-ES310 | 3 Years Extended Warranty Service (for MU909060A3) |
| J1480A | USB-Ethernet Converter — Requires MU909060Ax-y05 Remote GUI (sold separately) |
| W3166AE | MU909060A1/A2/A3 Operation Manual (Hardcopy – English version) |