Anritsu MA244xD series high accuracy diode power sensors, including the MA2444D
Anritsu / MA244xD Series / Diode Sensors
MA2444D

MA244xD Series MA2444D High Accuracy Diode Power Sensor (CW), 10 MHz to 40 GHz

High accuracy CW diode power sensor covering 10 MHz to 40 GHz with a -67 dBm to +20 dBm dynamic range and K(m) connector.

Frequency Range
10 MHz - 40 GHz
Video Bandwidth
100 kHz

Overview

The Anritsu MA2444D is a high accuracy diode power sensor in the MA244xD series, covering 10 MHz to 40 GHz. It is designed for use with the ML2430, ML2480 and ML2490 series power meters and is intended for high dynamic range, high accuracy CW and TDMA measurements.

The sensor has a built-in 3 dB attenuator that reduces input VSWR. This makes it suited to applications that need high measurement accuracy over a large dynamic range, such as amplifier measurements.

The MA244xD sensors have a dynamic range of 87 dB, compared with 90 dB for the MA247xD standard diode sensors. In all other respects their performance is the same as the standard diode sensor. Calibration factors are stored in the sensor's EEPROM.

Key Features

  • Wide dynamic range (-67 dBm to +20 dBm)
  • Accurate CW average power measurements
  • Frequency coverage from 10 MHz to 40 GHz
  • Built-in 3 dB attenuator to minimize input VSWR
  • Calibration factors stored in EEPROM
  • Precision K(m) RF connector with hexagon coupling nut for torque wrench attachment

Specifications

Frequency
Frequency Range 10 MHz - 40 GHz
Video Bandwidth 100 kHz
Series-level value from the category listing summary
Amplitude
Dynamic Range -67 to +20 dBm
Sensor Linearity 1.8%, < 18 GHz
Sensor Linearity 2.5%, < 40 GHz
Rise Time <0.004 ms
0.0 dBm, room temperature
SWR
SWR, 10-50 MHz <1.90
SWR, 50-150 MHz <1.17
SWR, 0.15-2 GHz <1.08
SWR, 2-12.4 GHz <1.16
SWR, 12.4-18 GHz <1.21
SWR, 18-32 GHz <1.29
SWR, 32-40 GHz <1.44
Physical
RF Connector K(m)
Precision RF connector with hexagon coupling nut for attachment by industry standard torque wrench
Compliance
EMC Directive 2014/30/EU
Low Voltage Directive 2014/35/EU
RoHS Directive 2011/65/EU & 2015/863
Electromagnetic Compatibility EN 61326-1:2013
Emissions EN 55011:2009 +A1:2010 Group 1 Class A
Electrical Safety EN 61010-1:2010
Warranty
Warranty 1 Year

Applications

  • High accuracy CW power measurement
  • TDMA power measurement
  • Amplifier measurements
  • Wide dynamic range power measurement