Anritsu ME7800L Simple Conformance Test System
ME7800L

Simple Conformance Test System ME7800L for LTE, Cat-M1 and NB-IoT RF and Protocol Testing

RF/RRM and protocol conformance test system for 3GPP LTE mobile terminals, including Cat-M1 and NB-IoT, approved by GCF/PTCRB.

Supported frequency bands
450 MHz to 3.8 GHz

Overview

The Anritsu ME7800L Simple Conformance Test System runs RF and protocol conformance tests on 3GPP-compliant LTE mobile terminals. It covers the basic LTE test items, including Cat-M1 and NB-IoT, and follows evolving 3GPP standards. RF/Performance/RRM tests and protocol tests can be added separately as needed. The system's built-in functions support work from network quality assurance through mobile terminal development.

Simple Equipment Configuration

The ME7800L focuses on the basic LTE test items, which keeps the amount of hardware required to a minimum. It is based on the ME7873LA and ME7834LA conformance test systems. A single Signalling Tester MD8430A acts as the base station simulator and runs both the RF/RRM and the protocol test software. Annual contract packages provide software updates for 3GPP standard changes as well as technical support.

Frequency Band Support

The system supports current and future 3GPP-defined frequency bands from 450 MHz to 3.8 GHz. This includes the GCF/PTCRB-certified bands used mainly in Europe and North America.

Certification and Reliability

The ME7800L received GCF/PTCRB approval as a new test platform in April 2017 and is registered as GCF Test Platform (TP) 160. Its calibration and correction functions are built in: basic correction at factory shipment, auto-calibration at start-up, and correction at each measurement. Because correction runs immediately before each measurement, temperature-related changes in the measurement system are removed, and customers do not need to calibrate the system every day.

Peripheral Control and Software

The DC power supply and constant temperature chamber needed for RF/RRM tests can be controlled by the system as standard; the customer supplies this equipment. Measurement results can be saved as HTML, XML or CSV, and the HTML reports link to the signalling log of each measurement. Protocol test logs can be analyzed with Protocol Analyzer 3. The system also outputs usage data by EUT, frequency band and measurement time.

Key Features

  • Designed for organizations starting conformance testing
  • All-in-one RF/RRM and protocol conformance testing with one Signalling Tester MD8430A
  • Compliant with 3GPP standards and approved by GCF/PTCRB
  • Registered as GCF Test Platform (TP) 160
  • Supports LTE Cat-M1 and NB-IoT
  • Supports spurious tests in the base model
  • Basic correction at factory shipment, auto-calibration at start-up and correction at each measurement
  • Built-in control of a DC power supply and a constant temperature chamber
  • Sequence creation and editing from a task pane
  • Histogram display of RRM measurement results
  • Real-time SS log display during measurement
  • Measurement results saved as HTML, XML or CSV
  • Protocol log analysis with Protocol Analyzer 3
  • Test case validation status from the GCF/PTCRB databases updated with one click
  • Support packages with 3GPP software updates and technical support

Specifications

Frequency
Supported frequency bands 450 MHz to 3.8 GHz
Current and future 3GPP-defined frequency bands
Connectors
TRx port N-J, 50Ω, Maximum input +35 dBm
Rx port N-J, 50Ω, Maximum input +30 dBm
Reference Oscillator
Reference output 10 MHz Buffered Output of MD8430A as standard
External oscillator signal input Available (Frequency: 10 MHz, Connector: BNC)
Environmental
Operating temperature 15 °C to 35 °C
Storage temperature 0 °C to 50 °C
Power Supply
Power voltage 100 V (ac) to 120 V (ac)/200 V (ac) to 240 V (ac)
Frequency 50 Hz/60 Hz
Power consumption ≤ 2500 VA
CE Marking
EMC 2014/30/EU, EN61326-1, EN61000-3-2
LVD 2014/35/EU, EN61010-1
RoHS 2011/65/EU, (EU) 2015/863, EN IEC 63000: 2018
UKCA Marking
EMC S.I. 2016 No.1091, EN 61326-1, EN61000-3-2
LVD S.I. 2016 No.1101, EN 61010-1
RoHS S.I. 2012 No.3032, EN IEC 63000:2018
Supported Test Standards
Supported releases Release 8, 9, 10 (only 2 Downlink Carrier Aggregation) and Release 13 (IoT only)
Applies to both RF/RRM and protocol testing
RF/RRM testing 3GPP TS 36.521-1 E-UTRA UE Conformance Specification Radio Transmission and Reception Part1: Conformance Testing
RF/RRM testing 3GPP TS 36.521-3 E-UTRA UE Conformance Specification Radio Transmission and Reception Part3: RRM Conformance Testing
Protocol testing 3GPP TS 36.523-1 Evolved Universal Terrestrial Radio Access (E-UTRA) and Evolved Packet Core (EPC); User Equipment (UE) conformance specification; Part 1: Protocol conformance specification
Protocol testing 3GPP TS 34.229-1 Internet Protocol (IP) multimedia call control protocol based on Session Initiation Protocol (SIP) and Session Description Protocol (SDP); User Equipment (UE) conformance specification; Part 1: Protocol conformance specification
System LTE/LTE-Advanced Cat-M/NB-IoT
Operating Bands (UL / DL Frequencies, MHz)
Band 1 UL 1920 to 1980, DL 2110 to 2170
Band 2 UL 1850 to 1910, DL 1930 to 1990
Band 3 UL 1710 to 1785, DL 1805 to 1880
Band 4 UL 1710 to 1755, DL 2110 to 2155
Band 5 UL 824 to 849, DL 869 to 894
Band 7 UL 2500 to 2570, DL 2620 to 2690
Band 8 UL 880 to 915, DL 925 to 960
Band 9 UL 1749.9 to 1784.9, DL 1844.9 to 1879.9
Band 10 UL 1710 to 1770, DL 2110 to 2170
Band 11 UL 1427.9 to 1447.9, DL 1475.9 to 1495.9
Band 12 UL 698 to 716, DL 728 to 746
Band 13 UL 777 to 787, DL 746 to 756
Band 14 UL 788 to 798, DL 758 to 768
Band 17 UL 704 to 716, DL 734 to 746
Band 18 UL 815 to 830, DL 860 to 875
Band 19 UL 830 to 845, DL 875 to 890
Band 20 UL 832 to 862, DL 791 to 821
Band 21 UL 1447.9 to 1462.9, DL 1495.9 to 1510.9
Band 24 UL 1626.5 to 1660.5, DL 1525 to 1559
Band 25 UL 1850 to 1915, DL 1930 to 1995
Band 26 UL 814 to 849, DL 859 to 894
Band 27 UL 807 to 824, DL 852 to 869
Band 28 UL 703 to 748, DL 758 to 803
Band 29 UL N/A, DL 717 to 728
Band 30 UL 2305 to 2315, DL 2350 to 2360
Band 31 UL 452.5 to 457.5, DL 462.4 to 467.5
Band 32 UL N/A, DL 1452 to 1496
Band 33 UL 1900 to 1920, DL 1900 to 1920
Band 34 UL 2010 to 2025, DL 2010 to 2025
Band 35 UL 1850 to 1910, DL 1850 to 1910
Band 36 UL 1930 to 1990, DL 1930 to 1990
Band 37 UL 1910 to 1930, DL 1910 to 1930
Band 38 UL 2570 to 2620, DL 2570 to 2620
Band 39 UL 1880 to 1920, DL 1880 to 1920
Band 40 UL 2300 to 2400, DL 2300 to 2400
Band 41 UL 2496 to 2690, DL 2496 to 2690
Band 42 UL 3400 to 3600, DL 3400 to 3600
Band 48 UL 3550 to 3700, DL 3550 to 3700
Band 66 UL 1710 to 1780, DL 2110 to 2200
Band 71 UL 663 to 698, DL 617 to 652

Applications

  • LTE mobile terminal conformance testing
  • Cat-M1 and NB-IoT device conformance testing
  • Mobile terminal, module and chipset R&D
  • Design verification
  • Pre-certification testing
  • Final-stage certification testing
  • Network quality assurance

Included

  • MN8160A Combiner Unit
  • Z1938B Standard PC for SimpleCT (with monitor)
  • ME7800L-AK000 Accessory Kit for ME7800L
  • MD8430A Signalling Tester
  • MS2692A Signal Analyzer
  • MA24218A Microwave Universal USB Power Sensor (10 MHz-18 GHz)
  • G0378B APSIN20 G-HC-AZ1 Signal Generator
  • ME7800L Operation Manual (CD-ROM), 1 set
  • Ethernet hub
  • Cables
  • Test SIM cards

Options & Accessories

Option Description
ME7800L-001 LTE Protocol Test Package
ME7800L-011 IoT Protocol Test Package
ME7800L-051 LTE RF/RRM Test Package
ME7800L-061 IoT RF/RRM Test Package