Anritsu Site Master S331P ultraportable cable and antenna analyzer
S331P

Site Master S331P Ultraportable Cable and Antenna Analyzer

Pocket-sized, USB-powered headless cable and antenna analyzer covering 150 kHz to 4 GHz or 6 GHz, including LTE-U frequencies.

Measurement types
VSWR, Return Loss, Cable Loss (One Port), Distance-to-Fault (DTF) Return Loss, Distance-to-Fault (DTF) VSWR
Advanced Mode measurement types
Smith Chart 50/75 Ω, 1-Port Phase, Transmission with External Sensor
Measurement display
Single Display with independent markers (Classic Mode); Single/Dual Display with independent markers (Advanced Mode)
Data points
130, 259, 517, 1033, 2065
Datasheet

Overview

The Anritsu Site Master S331P is an ultraportable, headless member of the Site Master family of cable and antenna analyzers. It is intended for wireless operators and contractors, DAS installers, and public safety network installation and maintenance teams.

The instrument has no battery or display. It is powered and controlled through the USB port of a Windows tablet, laptop or desktop PC. The technical data sheet also lists the Field Master Pro MS2090A with Option 331 and the MS2080A as controllers. Two frequency options are available, 150 kHz to 4 GHz and 150 kHz to 6 GHz. This range covers low-frequency radio communications and higher-frequency applications such as LTE-U in the 5 GHz unlicensed spectrum.

Operating modes

The PC application offers two modes. Classic Mode follows the layout of earlier Site Master D models. Advanced Mode adds 8 markers instead of 6, customizable shortcuts, a full-screen view, dual display, segmented upper and lower limit lines, marker peak/valley tracking, Smith Chart (50/75 Ω), 1-port phase and transmission measurements with an external USB sensor.

Calibration and data handling

A factory default 1-Port ReadyCal is applied to all measurements except Transmission. User OSL calibration and FlexCal are also supported. Sweeps, setups and screenshots are stored on the controlling PC in standard *.dat and *.csv formats. These files can be post-processed with Line Sweep Tools (LST) and are compatible with HHST. The instrument also works with easyTest Tools and the Multiwave Smart Aligner Android application for site closeout reports.

Key Features

  • Smallest, lightest, and fastest Site Master
  • Direct connection to DUTs eliminating the need for phase stable cables
  • Powered through USB interface, no battery required
  • Rugged and reliable; impact, dust and splash resistant
  • Factory default 1-Port ReadyCal automatically applied to all measurements except Transmission
  • FlexCal calibration – one calibration for all frequencies
  • Same user interface as the S331L
  • Integrated Help function
  • S331D-like Classic Mode
  • S331E-like Advanced Mode with additional markers, customizable shortcuts and full-screen view
  • EZ Name Quick Matrix for fast file naming
  • Controlled and powered by a Windows tablet or PC using standard USB 2.0, or the Field Master Pro MS2090A
  • Internal file storage limited only by space on PC or tablet
  • Fast preview of stored sweeps
  • Line Sweep Tools (LST) software to edit, rename and archive sweeps and generate PDF or HTML reports
  • Standard *.dat and *.csv file formats
  • Compatible with HHST
  • Compatible with easyTest Tools
  • Supported by Multiwave Smart Aligner Android application

Specifications

Measurements
Measurement types VSWR, Return Loss, Cable Loss (One Port), Distance-to-Fault (DTF) Return Loss, Distance-to-Fault (DTF) VSWR
Advanced Mode measurement types Smith Chart 50/75 Ω, 1-Port Phase, Transmission with External Sensor
Advanced Mode only
Measurement display Single Display with independent markers (Classic Mode); Single/Dual Display with independent markers (Advanced Mode)
Data points 130, 259, 517, 1033, 2065
Markers (Classic Mode) Markers 1 to 6 (On/Off), Delta Markers 2 to 4 (Ref M1), Marker to Peak/Valley, Marker Table
Markers (Advanced Mode) Markers 1 to 8 (On/Off), Delta Markers 2 to 8 (Ref M1), Marker Tracking (On/Off), Marker to Peak/Valley, Marker Table
Windowing Rectangular, Normal Side Lobe, Low Side Lobe, Minimum Side Lobe
Limit line (Advanced Mode) Edit Segments (42 upper and 42 lower segments maximum)
Calibration methods OSL (Classic Mode); OSL, Transmission, OSL + Transmission (Advanced Mode)
Cal Types: Standard, FlexCal; User Cal overrides factory default 1-Port ReadyCal
Frequency
Frequency range
S331P-0704
150 kHz to 4 GHz
Frequency range
S331P-0706
150 kHz to 6 GHz
Frequency accuracy ± 2.5 ppm
@ 23 °C ± 3 °C
Frequency resolution 1 kHz
Power
Output power –5 dBm
typical
Interference immunity +17 dBm
On Channel and On Frequency, typical
Measurement speed 500 µs/data point
timing dependent on external computer configuration
Measurement Ranges
Return loss measurement range 0 to 60 dB
Return loss resolution 0.01 dB
VSWR measurement range 1 to 65
VSWR resolution 0.01
Cable loss measurement range 0 to 30 dB
Cable loss resolution 0.01 dB
DTF vertical range, return loss 0 to 60 dB
DTF vertical range, VSWR 1 to 65
DTF fault resolution (meters) (1.5 x 10^8 x vp)/ΔF
vp = propagation velocity, ΔF is F2 – F1 in Hz
DTF horizontal range (meters) 0 to (Data Points – 1) x Fault Resolution, to maximum of 1500 meters (4921 ft)
1-Port phase display range –450 ° to +450 °
Advanced Mode only; resolution 0.01 °
Smith chart impedance 50 Ω, 75Ω
Advanced Mode only; resolution 0.01
Transmission (external sensor) display range –100 dB to +100 dB
Advanced Mode only; resolution 0.01 dB
Corrected directivity ≥ 42 dB
OSL calibration (OSLN50A-8, OSLNF50A-8), at 23 °C ± 3 °C
General
Languages English, French, German, Italian, Spanish, Russian, Portuguese, Japanese, Korean, Chinese
Save file types Measurement (*.dat, *.csv), Setup (*.stp), Screen Shot (*.png), System and Self Test Info (*.txt)
Internal trace/setup memory > 1000 files for traces, setups, screen shots, or any combination
limited by PC/Tablet storage
Connectivity USB
Connectors
RF port type N(m), 50Ω
RF port maximum input +23 dBm maximum, ±50 VDC maximum
USB port USB 2.0 port for connecting to an external PC controller
Regulatory Compliance
European Union EMC 2014/30/EU, EN 61326:2013, CISPR 11/EN 55011, IEC/EN 61000-4-2/3/4/5/6/8/11
Low Voltage Directive 2014/35/EU
Safety EN 61010-1:2010
RoHS Directive 2011/65/EU
applies to instruments with CE marking placed on the market after July 22, 2017
Australia and New Zealand RCM AS/NZS 4417:2012
South Korea KCC-REM-A21-0004
Environmental
Environmental standard MIL-PRF-28800F Class 2
Operating temperature range –10 ºC to 55 ºC
Storage temperature range –51 ºC to 71 ºC
Maximum relative humidity 95 % RH at 30 ºC
non-condensing
Vibration, sinusoidal 5 Hz to 55 Hz
Vibration, random 10 Hz to 500 Hz
Half sine shock 30 g
Altitude 4600 meters
operating and non-operating
Size and Weight
Size 52 mm x 148 mm x 36 mm (2 in x 5.8 in x 1.4 in)
Weight < 0.4 kg (< 0.9 lb)
typical
Recommended External PC/Controller
USB port One USB 2.0 (or higher) port
Operating systems Windows 7, 8, 8.1, 10, 11; 32 or 64 bit
Tested with tablets running Windows 10 or 11 and Intel Atom X5-Z8300 processor
Alternative controllers MS2090A with Option 331, and MS2080A

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • Wireless operator cable and antenna maintenance
  • Base station installation and commissioning
  • DAS installation
  • Public safety network installation and maintenance
  • Low frequency radio communications
  • LTE-U in the 5 GHz unlicensed spectrum
  • Line sweep closeout reporting
  • C-RAN

Included

  • Soft Carrying Case (2000-1864-R)
  • Torque Multiplier N(m) (2000-1687-R)
  • USB-A to Micro-USB cable, 1.83 m (6 ft) (2000-2010-R)
  • Standard Three-Year Warranty
  • Certificate of Calibration and Conformance

Options & Accessories

Option Description
S331P-0704 Frequency option, 150 kHz to 4 GHz — One frequency option required
S331P-0706 Frequency option, 150 kHz to 6 GHz — One frequency option required
S331P-ES510 Warranty Extension to 5 Years
S331P-ES513 Warranty Extension to 5 Years with Z540 Calibration
S331P-0098 Standard Calibration to ISO17025 and ANSI/NCSL Z540-1 — Includes calibration certificate.
S331P-0099 Premium Calibration to ISO17025 and ANSI/NCSL Z540-1 — Includes calibration certificate, test report, and uncertainty data.
MA24330A Microwave CW USB Power Sensor, 10 MHz to 33 GHz, +20 dBm
MA24340A Microwave CW USB Power Sensor, 10 MHz to 40 GHz, +20 dBm
MA24350A Microwave CW USB Power Sensor, 10 MHz to 50 GHz, +20 dBm
MA24108A Microwave USB Power Sensor, 10 MHz to 8 GHz, +20 dBm to –40 dBm
MA24118A Microwave USB Power Sensor, 10 MHz to 18 GHz, +20 dBm to –40 dBm
MA24126A Microwave USB Power Sensor, 10 MHz to 26 GHz, +20 dBm to –40 dBm
MA24208A Microwave Universal USB Power Sensor, 10 MHz to 8 GHz, +20 dBm to –60 dBm
MA24218A Microwave Universal USB Power Sensor, 10 MHz to 18 GHz, +20 dBm to –60 dBm
MA24105A Inline Dual Directional High Power Sensor, 350 MHz to 4 GHz, +3 dBm to +51.76 dBm
MA24106A High Accuracy RF Power Sensor, 50 MHz to 6 GHz, +23 dBm to –40 dBm
MA25100A RF Power Indicator
SC8268 USB Transmission Sensor, K(m), 1 MHz to 40 GHz, +10 dBm to –50 dBm
67135 Anritsu Backpack (for instrument and PC)
760-283 Transit Case, USB 1 Port VNA
OSLN50A-8 High Performance Type N(m), DC to 8 GHz, 50Ω — Calibration component
OSLNF50A-8 High Performance Type N(f), DC to 8 GHz, 50Ω — Calibration component
2000-1618-R Precision Open/Short/Load, 7/16 DIN(m), DC to 6.0 GHz, 50 Ω
2000-1619-R Precision Open/Short/Load, 7/16 DIN(f), DC to 6.0 GHz, 50 Ω
2000-1914-R Precision Open/Short/Load, 4.3-10(f), DC to 6 GHz, 50 Ω
2000-1915-R Precision Open/Short/Load, 4.3-10(m), DC to 6 GHz, 50 Ω
22N50 Open/Short, N(m), DC to 18 GHz, 50 Ω
22NF50 Open/Short, N(f), DC to 18 GHz, 50 Ω
SM/PL-1 Precision Load, N(m), 42 dB, 6.0 GHz
SM/PLNF-1 Precision Load, N(f), 42 dB, 6.0 GHz
22N75 Open/Short, N(m), DC to 3 GHz, 75 Ω
22NF75 Open/Short, N(f), DC to 3 GHz, 75 Ω
510-90-R Adapter, 7/16 DIN(f) to N(m), DC to 7.5 GHz, 50Ω
510-91-R Adapter, 7/16 DIN(f) to N(f), DC to 7.5 GHz, 50Ω
510-92-R Adapter, 7/16 DIN(m) to N(m), DC to 7.5 GHz, 50Ω
510-93-R Adapter, 7/16 DIN(m) to N(f), DC to 7.5 GHz, 50Ω
510-96-R Adapter, 7/16 DIN(m) to 7/16 DIN(m), DC to 7.5 GHz, 50 Ω
510-97-R Adapter, 7/16 DIN(f) to 7/16 DIN(f), DC to 7.5 GHz, 50 Ω
1091-80-R Adapter, SMA(m) to N(f), DC to 18 GHz, 50 Ω
1091-81-R Adapter, SMA(f) to N(f), DC to 18 GHz, 50 Ω
1091-433-R Low PIM Adapter, 4.1-9.5(f) to 7/16 DIN(f), DC to 3.0 GHz, 50 Ω
1091-434-R Low PIM Adapter, 4.1-9.5(m) to 7/16 DIN(f), DC to 3.0 GHz, 50Ω
1091-440-R Low PIM Adapter, 4.3-10(f) to 7/16 DIN(f), DC to 6.0 GHz, 50Ω
1091-441-R Low PIM Adapter, 4.3-10(m) to 7/16 DIN(f), DC to 6.0 GHz, 50 Ω
1091-442-R Low PIM Adapter, 4.3-10(f) to N(m), DC to 6.0 GHz, 50Ω
1091-443-R Low PIM Adapter, 4.3-10(m) to N(m), DC to 6.0 GHz, 50 Ω
1091-465-R Adapter, DC to 6 GHz, 4.3-10(f) to N(f), 50 Ω
1091-467-R Adapter, DC to 6 GHz, 4.3-10(m) to N(f), 50 Ω
34NN50A Precision Adapter, N(m) to N(m), DC to 18 GHz, 50 Ω
34NFNF50 Precision Adapter, N(f) to N(f), DC to 18 GHz, 50 Ω
3-1010-122 Attenuator, 20 dB, 5 W, DC to 12.4 GHz, N(m) to N(f)
42N50-20 Attenuator, 20 dB, 5 W, DC to 18 GHz, N(m) to N(f)
42N50A-30 Attenuator, 30 dB, 50 W, DC to 18 GHz, N(m) to N(f)
3-1010-123 Attenuator, 30 dB, 50 W, DC to 8.5 GHz, N(m) to N(f)
1010-127-R Attenuator, 30 dB, 150 W, DC to 3 GHz, N(m) to N(f)
1010-128-R Attenuator, 40 dB, 150 W, DC to 3 GHz, N(m) to N(f)
3-1010-124 Attenuator, 40 dB, 100 W, DC to 8.5 GHz, N(f) to N(m), Uni-directional
2000-1900-R Single Port 2.0 USB 100 meter Cat 5e Range Extender — With Type A power cord for USA, Japan, North America, Central America and Caribbean
2000-1901-R Single Port USB 2.0 100 meter Cat 5e Extender — With Type C power cord for use in Europe, India, South Korea, and many countries in Middle East and Africa
2000-1902-R Single Port USB 2.0 100 meter Cat 5e Extender — With Type I power cord for use in Australia, New Zealand, Argentina, and the South Pacific
2000-1903-R Single Port USB 2.0 100 meter Cat 5e Extender — With Type G power cord for use in the UK, and several other countries in Asia, the Middle East, and Africa
2000-1717-R USB 1.1 Passive 40 m Extender — Not compatible with sensors MA24208A, MA24218A, MA24330A, MA24340A, MA24350A; must use active extenders with these sensors
2100-28-R Cat 5e extension cable for use with USB Extender (22.5 m)

Documents & Resources