Site Master S331L Handheld Cable and Antenna Analyzer, 2 MHz to 4 GHz
Rugged handheld 2 MHz to 4 GHz cable and antenna analyzer with built-in InstaCal module, 50 MHz to 4 GHz power meter and over 8 hours of battery life.
- Frequency Range
- 2 MHz to 4 GHz
- Frequency Accuracy
- ± 5 ppm
- Frequency Resolution
- 1 kHz
- Output Power
- –3 dBm
Overview
The Anritsu Site Master S331L is a rugged, handheld one-port cable and antenna analyzer covering 2 MHz to 4 GHz, intended for the installation and maintenance of antenna systems. It weighs under 2.0 kg (4.4 lb) including battery, is impact, dust and splash resistant, and provides more than 8 hours of continuous battery operation. It replaces the S331D in the Site Master family.
The instrument measures return loss, VSWR, cable loss, distance-to-fault (return loss and VSWR), Smith chart (50/75 Ω selectable), 1-port phase and RF power from 50 MHz to 4 GHz. A built-in InstaCal module provides one-connection calibration, and FlexCal maintains calibration when the frequency range is changed. Transmission measurements with an external sensor are available in Advanced Mode.
Operating modes
A Classic Mode follows the measurement flow of the S331D, while an Advanced Mode adds up to 8 markers, customizable shortcuts, dual display, segmented upper/lower limit lines, marker peak/valley tracking, Smith chart and 1-port phase measurements. The 800 x 480 7 in daylight-viewable TFT touch screen includes an alphanumeric keyboard and the EZ Name quick naming matrix.
Data management and connectivity
More than 1000 files can be stored internally, with fast preview of stored traces. Sweeps use the standard *.dat format compatible with Line Sweep Tools (LST) and Handheld Software Tools (HHST). Two USB Type A ports and a USB mini-B port support file transfer, USB power sensors, GPS modules, an Ethernet adapter and the USB Video Inspection Probe for IEC 61300-3-35 based optical connector inspection. The S331L is supported by the Multiwave Smart Aligner Android application for site closeout reports combining antenna alignment and line sweep results.
Key Features
- 2 MHz to 4 GHz handheld cable and antenna analyzer, impact, dust and splash resistant
- More than 8 hours of continuous battery operation
- Standard built-in InstaCal module and power meter
- FlexCal maintains calibration with frequency changes
- Built-in one button Help function
- S331D-like Classic Mode and S331E-like Advanced Mode
- 800 x 480 7 in TFT touch screen display and multiple USB ports
- Internally store >1000 files with fast preview of stored traces
- Backlit keypad
- Instant on from standby mode
- High accuracy power measurements with external USB power sensor
- Location data with compatible USB GPS module
- Supported by Multiwave Smart Aligner Android application
- Industry standard *.dat format compatible with Line Sweep Tools (LST) and HHST
- easyTest work instruction support
- Optical connector inspection with IEC 61300-3-35 based Pass/Fail standard (requires Video Inspection Probe)
- Field replaceable InstaCal/power meter module
- Standard three-year warranty (battery one-year warranty)
Specifications
| Frequency Range | 2 MHz to 4 GHz |
|---|---|
| Frequency Accuracy |
± 5 ppm
@ 23 °C ± 3 °C
|
| Frequency Resolution | 1 kHz |
| Output Power |
–3 dBm
typical
|
| Data Points | 130, 259, 517, 1033, 2065 |
| On-Channel Interference Immunity |
+17 dBm
outside calibrated sweep range
|
|---|---|
| On-Frequency Interference Immunity |
+13 dBm
within calibrated sweep range
|
| Measurement Speed, Return Loss |
≤ 1.50 ms/data point
RF immunity low, typical
|
| Measurement Speed, Distance-to-Fault |
≤ 1.75 ms/data point
RF immunity low, typical
|
| Return Loss Measurement Range | 0 to 60 dB |
|---|---|
| Return Loss Resolution | 0.01 dB |
| VSWR Measurement Range | 1 to 65 |
| VSWR Resolution | 0.01 |
| Cable Loss Measurement Range | 0 to 30 dB |
| Cable Loss Resolution | 0.01 dB |
| DTF Vertical Range Return Loss | 0 to 60 dB |
| DTF Vertical Range VSWR | 1 to 65 |
| DTF Fault Resolution (meters) |
(1.5 x 10^8 x vp)/ΔF
vp = propagation velocity, ΔF is F2 – F1 in Hz
|
| DTF Horizontal Range (meters) | 0 to (Data Points – 1) x Fault Resolution, to maximum of 1500 meters (4921 ft) |
| 1-Port Phase Measurement Display Range |
–450 ° to +450 °
Advanced Mode only; resolution 0.01 °
|
| Smith Chart Impedance |
50 Ω, 75 Ω
Advanced Mode only; resolution 0.01
|
| Transmission Ext Sensor Measurement Display Range |
–100 dB to +100 dB
Advanced Mode only; resolution 0.01 dB
|
| Corrected Directivity, InstaCal |
≥ 38 dB
at 23 °C ± 3 °C, InstaCal calibration
|
|---|---|
| Corrected Directivity, OSL |
≥ 42 dB
at 23 °C ± 3 °C, OSL calibration (OSLN50A-8, OSLNF50A-8, OSLN50-1, OSLNF50-1)
|
| Frequency Range | 50 MHz to 4 GHz |
|---|---|
| Display Range | –100 dBm to +100 dBm |
| Offset Range | Max ± 100 dB, user settable value |
| Measurement Range | –33 dBm to +20 dBm |
| VSWR |
1.5:1
typical
|
| Maximum Power |
+27 dBm, ± 45 VDC
damage level
|
| Connector | Type N(m), 50 Ω |
| Accuracy |
± 0.7 dB
0 dBm, 1 GHz CW, @ 23 °C ± 3 °C
|
| Frequency Response and Linearity | Additional ± 0.8 dB (± 0.5 dB typical) |
| Temperature Effect |
Additional ± 0.02 dB per 1 °C change
typical
|
| Supported USB Power Sensors |
MA24105A, MA24106A, MA24108A/18A/26A, MA24208A/18A, MA24330A/40A/50A
requires external USB power sensor, sold separately
|
|---|
| Probe Models |
G0306A/B/C 400X USB Visual Inspection Probe
sold separately
|
|---|---|
| Test Profile (IEC 61300-3-35) | SM PC >45, SM APC, SM PC >25, MM PC 62.5, MM PC 50.0 |
| Generate Report | Generates pdf report with options to include multiple *.vipi files |
| Internal Trace/Setup Memory |
> 1000 files
files may be traces, setups, screen shots, or any combination
|
|---|---|
| External Trace/Setup Memory | Limited only by size of USB Flash drive |
| RF Out/Reflect In | Type N, female, 50 Ω, Maximum Input +42 dBm, ± 50 VDC |
| InstaCal/Power Meter |
Type N, male, 50 Ω, Maximum Input +27 dBm, ± 45 VDC
damage level
|
| External Power | 5.5 mm barrel connector, 11 to 14 VDC, < 3.0 A |
| USB Ports | USB 2.0 Type A (two ports) |
| USB Interface | Type mini-B, Connect to PC for data transfer |
| Connectivity |
GPS, Ethernet Configuration (DHCP/Static)
external GPS USB module sold separately
|
| Type | TFT Resistive Touch Screen |
|---|---|
| Size | 7.0 in daylight viewable color LCD |
| Resolution | 800 x 480 |
| Pixel Defects | No more than five defective pixels (99.9986% good pixels) |
| Languages | English, French, German, Italian, Spanish, Russian, Portuguese, Japanese, Korean, Chinese |
| Type | Li-Ion |
|---|---|
| Battery Operation |
> 8.0 Hours
typical, 70 % brightness setting, continuous usage
|
| Standby |
7 days
typical, with fully charged battery; actual time will vary depending on battery charge level
|
| Standard | MIL-PRF-28800F Class 2 |
|---|---|
| Operating Temperature Range | –10 ºC to 55 ºC |
| Storage Temperature Range | –51 ºC to 71 ºC |
| Maximum Relative Humidity | 95 % RH at 30 ºC, non-condensing |
| Vibration, Sinusoidal | 5 Hz to 55 Hz |
| Vibration, Random | 10 Hz to 500 Hz |
| Half Sine Shock | 30 gn |
| Altitude | 4600 meters, operating and non-operating |
| Explosive Atmosphere | MIL-PRF-28800F Section 4.5.6.3, MIL-STD-810G, Method 511.5, Procedure 1 |
| European Union EMC | 2014/30/EU, EN 61326:2013, CISPR 11/EN 55011, IEC/EN 61000-4-2/3/4/5/6/8/11 |
|---|---|
| Low Voltage Directive | 2014/35/EU |
| Safety | EN 61010-1:2010 |
| RoHS |
Directive 2011/65/EU
applies to instruments with CE marking placed on the market after July 22, 2017
|
| Australia and New Zealand | RCM AS/NZS 4417:2012 |
| Canada | ICES-1(A)/NMB-1(A) |
| South Korea | KCC-REM-A21-0004 |
| Size | 250 mm x 177 mm x 61 mm (10.0 in x 7.1 in x 2.4 in) |
|---|---|
| Weight | < 2.0 kg (4.4 lb), including battery |
| Warranty | Standard three-year warranty (battery one-year warranty) |
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- Cellular
- Public safety
- Radio and TV broadcasting
- Aerospace and defense
- 1-port RF cable and antenna testing
- Base station installation and maintenance
- Tower contracting and line sweep closeout reports
- Optical connector inspection in BBU/RRH links
Included
- 2000-1676-R Soft Carrying Case
- 2000-1691-R Stylus with Coiled Tether
- 2000-1687-R Torque Multiplier N(m)
- 40-187-R AC-DC Adapter with AC power cord (country dependent)
- 806-141-R Automotive Power Adapter, 12 VDC, 60 W
- 3-2000-1498 USB A/5-pin mini-B Cable, 305 cm (120 in)
- Certificate of Calibration and Conformance
- Standard three-year warranty (battery one-year warranty)
Options & Accessories
| Option | Description |
|---|---|
| S331L-ES510 | Warranty Extension to 5 Years, Return to Anritsu |
| S331L-ES513 | Warranty Extension to 5 Years with Z540 Calibration, Return to Anritsu |
| S331L-0098 | Standard Calibration to ISO17025 and ANSI/NCSL Z540-1 — Includes calibration certificate. |
| S331L-0099 | Premium Calibration to ISO17025 and ANSI/NCSL Z540-1 — Includes calibration certificate, test report, and uncertainty data. |
| MA24105A | Inline Dual Directional High Power Sensor, 350 MHz to 4 GHz, +3 dBm to +51.76 dBm |
| MA24106A | High Accuracy RF Power Sensor, 50 MHz to 6 GHz, +23 dBm to –40 dBm |
| MA24108A | Microwave USB Power Sensor, 10 MHz to 8 GHz, +20 dBm to –40 dBm |
| MA24118A | Microwave USB Power Sensor, 10 MHz to 18 GHz, +20 dBm to –40 dBm |
| MA24126A | Microwave USB Power Sensor, 10 MHz to 26 GHz, +20 dBm to –40 dBm |
| MA24208A | Microwave Universal USB Power Sensor, 10 MHz to 8 GHz, +20 dBm to –60 dBm |
| MA24218A | Microwave Universal USB Power Sensor, 10 MHz to 18 GHz, +20 dBm to –60 dBm |
| MA24330A | Microwave CW USB Power Sensor, 10 MHz to 33 GHz, +20 dBm |
| MA24340A | Microwave CW USB Power Sensor, 10 MHz to 40 GHz, +20 dBm |
| MA24350A | Microwave CW USB Power Sensor, 10 MHz to 50 GHz, +20 dBm |
| MA25100A | RF Power Indicator |
| SC8268 | USB Transmission Sensor, K(m), 1 MHz to 40 GHz, +10 dBm to –50 dBm |
| 67135 | Anritsu Backpack (for Handheld Instrument and PC) |
| 760-286-R | Compact Transit Case with Wheels and Handle — 55.6 cm x 35.5 cm x 22.9 cm (21.89" x 13.98" x 9.01") |
| 2000-1900-R | Single Port 2.0 USB 100 meter Cat 5e Range Extender — With Type A power cord for USA, Japan, North America, Central America and Caribbean. |
| 2000-1717-R | USB 1.1 Passive 40 m Extender — Not compatible with sensors MA24208A, MA24218A, MA24330A, MA24340A, MA24350A; must use active extenders with these sensors. |
| 2100-28-R | Cat 5e extension cable for use with USB Extender (22.5 m) |
| 2000-1723-R | High Performance USB Mag-Mount GPS Module |
| 2000-1810-R | Portable USB to Ethernet LAN Adapter |
| G0306A/B/C | Video Inspection Probe (400x) — Includes standard universal and bulkhead connector tips. |
| 15RDN50-1.5-R | Phase-Stable Test Port Cable, Armored w/Reinforced Grip, 1.5 m, DC to 6 GHz, N(m) to 7/16 DIN(m), 50Ω |
| 15RNFN50-1.5-R | Phase-Stable Test Port Cable, Armored w/Reinforced Grip, 1.5 m, DC to 6 GHz, N(m) to N(f), 50Ω |
| 15RDFN50-1.5-R | Phase-Stable Test Port Cable, Armored w/Reinforced Grip, 1.5 m, DC to 6 GHz, N(m) to 7/16 DIN(f), 50Ω |
| 15RNFN50-3.0-R | Phase-Stable Test Port Cable, Armored w/Reinforced Grip, 3.0 m, DC to 6 GHz, N(m) to N(f), 50Ω |
| 15RDN50-3.0-R | Phase-Stable Test Port Cable, Armored w/Reinforced Grip, 3.0 m, DC to 6 GHz, N(m) to 7/16 DIN(m), 50Ω |
| 15RDFN50-3.0-R | Phase-Stable Test Port Cable, Armored w/Reinforced Grip, 3.0 m, DC to 6 GHz, N(m) to 7/16 DIN(f), 50Ω |
| 15RCN50-1.5-R | Interchangeable Adapter Phase-Stable Test Port Cable, 1.5 m, DC to 6 GHz, N(m), N(f), 7/16 DIN(m), 7/16 DIN(f), 50Ω |
| 15RCN50-3.0-R | Interchangeable Adapter Phase-Stable Test Port Cable, 3.0 m, DC to 6 GHz, N(m), N(f), 7/16 DIN(m), 7/16 DIN(f), 50Ω |
| 15NNF50-1.5C | Phase-Stable Test Port Cable, Armored, 1.5 m, DC to 6 GHz, N(m) to N(f), 50Ω |
| 15NN50-1.5C | Phase-Stable Test Port Cable, Armored, 1.5 m, DC to 6 GHz, N(m) to N(m), 50Ω |
| 15NNF50-3.0C | Phase-Stable Test Port Cable, Armored, 3.0 m, DC to 6 GHz, N(m) to N(f), 50Ω |
| 15NN50-3.0C | Phase-Stable Test Port Cable, Armored, 3.0 m, DC to 6 GHz, N(m) to N(m), 50Ω |
| 15NNF50-5.0C | Phase-Stable Test Port Cable, Armored, 5.0 m, DC to 6 GHz, N(m) to N(f), 50Ω |
| 15NN50-5.0C | Phase-Stable Test Port Cable, Armored, 5.0 m, DC to 6 GHz, N(m) to N(m), 50Ω |
| 15NDF50-1.5C | Phase-Stable Test Port Cable, Armored, 1.5 m, DC to 6 GHz, N(m) to 7/16 DIN(f), 50Ω |
| 15ND50-1.5-C | Phase-Stable Test Port Cable, Armored, 1.5 m, DC to 6 GHz, N(m) to 7/16 DIN(m), 50Ω |
| 15N43M50-1.5C | Test Port Extension Cable, Armored, 1.5 m, DC to 6 GHz, N(m) to 4.3-10(m) |
| 15N43F50-1.5C | Test Port Extension Cable, Armored, 1.5 m, DC to 6 GHz, N(m) to 4.3-10(f) |
| 15N43M50-3.0C | Test Port Extension Cable, Armored, 3 m, DC to 6 GHz, N(m) to 4.3-10(m) |
| 15N43F50-3.0C | Test Port Extension Cable, Armored, 3 m, DC to 6 GHz, N(m) to 4.3-10(f) |
| OSLN50A-8 | High Performance Type N(m) Calibration Component, DC to 8 GHz, 50Ω |
| OSLNF50A-8 | High Performance Type N(f) Calibration Component, DC to 8 GHz, 50Ω |
| 22N50 | Open/Short, N(m), DC to 18 GHz, 50 Ω |
| 22NF50 | Open/Short, N(f), DC to 18 GHz, 50 Ω |
| 2000-1914-R | Precision Open/Short/Load, 4.3-10(f), DC to 6 GHz, 50 Ω |
| 2000-1915-R | Precision Open/Short/Load, 4.3-10(m), DC to 6 GHz, 50 Ω |
| 2000-1618-R | Precision Open/Short/Load, 7/16 DIN(m), DC to 6.0 GHz, 50 Ω |
| 2000-1619-R | Precision Open/Short/Load, 7/16 DIN(f), DC to 6.0 GHz, 50 Ω |
| SM/PL-1 | Precision Load, N(m), 4 dB, 6.0 GHz, 50 Ω |
| SM/PLNF-1 | Precision Load, N(f), 4 dB, 6.0 GHz, 50 Ω |
| 22N75 | Open/Short, N(m), DC to 3 GHz, 75 Ω |
| 22NF75 | Open/Short, N(f), DC to 3 GHz, 75 Ω |
| 1091-26-R | Adapter, SMA(m) to N(m), DC to 18 GHz, 50Ω |
| 1091-27-R | Adapter, SMA(f) to N(m), DC to 18 GHz, 50Ω |
| 1091-80-R | Adapter, SMA(m) to N(f), DC to 18 GHz, 50Ω |
| 1091-81-R | Adapter, SMA(f) to N(f), DC to 18 GHz, 50Ω |
| 1091-172-R | Adapter, BNC(f) to N(m), DC to 1.3 GHz, 50Ω |
| 1091-442-R | Low PIM Adapter, 4.3-10(f) to N(m), DC to 6.0 GHz, 50Ω |
| 1091-443-R | Low PIM Adapter, 4.3-10(m) to N(m), DC to 6.0 GHz, 50Ω |
| 1091-465-R | Adapter, DC to 6 GHz, 4.3-10(f) to N(f), 50Ω |
| 1091-467-R | Adapter, DC to 6 GHz, 4.3-10(m) to N(f), 50Ω |
| 510-90-R | Adapter, 7/16 DIN(f) to N(m), DC to 7.5 GHz, 50Ω |
| 510-91-R | Adapter, 7/16 DIN(f) to N(f), DC to 7.5 GHz, 50Ω |
| 510-92-R | Adapter, 7/16 DIN(m) to N(m), DC to 7.5 GHz, 50Ω |
| 510-93-R | Adapter, 7/16 DIN(m) to N(f), DC to 7.5 GHz, 50Ω |
| 34NN50A | Precision Adapter, N(m) to N(m), DC to 18 GHz, 50Ω |
| 34NFNF50 | Precision Adapter, N(f) to N(f), DC to 18 GHz, 50Ω |
| 1010-128-R | Attenuator, 40 dB, 150 W, DC to 3 GHz, N(m) to N(f) |
| 1010-127-R | Attenuator, 30 dB, 150 W, DC to 3 GHz, N(m) to N(f) |
| 42N50-20 | Attenuator, 20 dB, 5 W, DC to 18 GHz, N(m) to N(f) |
| 42N50A-30 | Attenuator, 30 dB, 50 W, DC to 18 GHz, N(m) to N(f) |