L-band booster erbium doped fiber amplifier module for the VIAVI MAP series, with gain and power control and a 1565 nm – 1610 nm operating range.

Operating Wavelength Range
1565 nm – 1610 nm
Saturated Power
≥ 20 dBm (-4 dBm input)
Noise Figure, Pin = 0 dBm
≤ 5.7 dB
Noise Figure, Pin = -4 dBm
≤ 5.5 dB
Datasheet

Overview

The VIAVI MEDFA-C11LB is the L-band booster variant of the Multiple Application Platform (MAP) Erbium Doped Fiber Amplifier (mEDFA-C1) module family. The mEDFA-C1 is a third-generation amplifier design intended for systems-lab use and optical test and measurement applications. It is the L-band version of the booster amplifier, built for single-channel input signals, and includes gain and power control.

Functional description

The optics of the module consist of an erbium-doped fiber amplifier gain stage with supporting optical components. These are designed to achieve maximum output power at the bulkhead-mounted optical connector while maximizing input/output isolation. When the erbium atoms in the doped fiber are excited, the fiber amplifies the light signals passing through it.

Control and platform

The module belongs to the LightDirect module family, a subset of the MAP series, which is characterized by a simple control interface and single-function modules. The MAP series complies with LAN Extensions for Instrumentation (LXI) and provides IVI drivers for development environments such as LabVIEW, Visual C++, Visual Basic and LabWindows. Commands generally conform to SCPI. On the MAP-300, the module GUI can be reached through a web browser or remote VNC and allows control of the current-mode set point and the pump laser state. The mEDFA is compatible with all current MAP-300 and MAP-200 chassis.

Key Features

  • L-band version of the mEDFA-C1 booster amplifier
  • Single-channel input
  • Gain and power control
  • Input and output power monitor
  • Standard saturated output power
  • FC/APC connectors
  • Compatible with all current MAP-300 and MAP-200 chassis
  • Controllable from the front panel or over the remote interface
  • SCPI-conforming commands with LXI compliance and IVI drivers

Specifications

Optical
Operating Wavelength Range 1565 nm – 1610 nm
All optical measurements done after minimum 30 minutes warming up at constant temperature of 23±3°C
Saturated Power ≥ 20 dBm (-4 dBm input)
Measured with input signal at 1590nm for L-band
Noise Figure, Pin = 0 dBm ≤ 5.7 dB
Measured at wavelength of 1590nm for L-band
Noise Figure, Pin = -4 dBm ≤ 5.5 dB
Measured at wavelength of 1590nm for L-band
Noise Figure, Pin = -20 dBm ≤ 5.2 dB
Measured at wavelength of 1590nm for L-band
Gain, Pin = 0 dBm ≥ 20 dB
Measured at wavelength of 1590nm for L-band
Gain, Pin = -4 dBm ≥ 23 dB
Measured at wavelength of 1590nm for L-band
Gain, Pin = -20 dBm ≥ 28 dB
Measured at wavelength of 1590nm for L-band
Input Output Power Monitor Yes
PDL/PDG ≤ 0.2dB
Measured with input power of 0dBm at 1590nm for L-band
Laser Safety Class 1M
Classified as per standard IEC60825-1:2014 with the maximum input power +4dBm
Configuration
Amplifier per Module 1
Input Type Single Channel
Band L
Gain and Power Control Yes
Saturated Output Power Standard
General
Connector Type FC/APC
Operating Temperature 0 - 40°C
Operating Humidity Maximum 95% RH, 0 to 40°C noncondensing
Storage Temperature -30 to 60°C
Dimensions (W x H x D) 4.06 cm x 13.26 cm x 37.03 cm
Weight 2.3 kg
Compliance
Compliance Complies to CE, CSA/UL/IEC61010-1, LXI Class C requirements, meets the requirements of Class 3B in standard IEC 60825-1 (2014), and complies with 21 CFR 1040.1 except deviations per Laser Notice No. 50, July 2001
When installed in a MAP chassis

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • Amplification of sensitive signals in automated test systems
  • Power saturation recovery testing
  • OSNR noise loading
  • Single channel tunable signal applications
  • Amplifier emulation
  • Network compliance tests

Options & Accessories

Option Description
MEDFA-C11LB-M100-MFA Standard power, Extended L-band amplifier, Single channel auto power and monitoring option with FC/APC connectors
AC500 FC/PC-FC/PC Universal Connector Adapter — Replacement mating sleeve
AC501 FC/PC-SC/PC Universal Connector Adapter — Replacement mating sleeve
AC502 FC/APC-FC/APC Universal Connector Adapter — Replacement mating sleeve
AC503 FC/APC-SC/APC Universal Connector Adapter — Replacement mating sleeve
CleanBlast CleanBlast fiber end-face cleaning system — Optional inspection and cleaning tool for removing dirt and debris from connectors; available in benchtop and portable versions.
FiberChek FiberChek probe microscope — Optional one-button, fully autonomous handheld fiber inspection probe.
P5000i P5000i fiber microscope — Optional automated fiber inspection and analysis probe with PASS/FAIL capability for PCs, laptops, mobile devices and VIAVI test solutions.

Documents & Resources