VIAVI TestCenter dX3 DX3-QSFP-DD-2 400G 2-Port QSFP-DD Test Module
2-port QSFP-DD TestCenter test module for SPT-N12U and SPT-N4U chassis, 400G to 10G with PAM4 and NRZ encoding
- MSA interface
- QSFP-DD
- Operational modes
- PAM4: 400/200/100/50G; NRZ: 100/50/40/25/10G
- Per-port configurations
- PAM4: 1x400G, 2x200G, 4x100G, 8x50G; NRZ: 2x100G, 4x50G, 2x40G, 8x25G, 8x10G
- Maximum ports per slot (DX3-QSFP-DD-2-825A, -750A)
- 2/4/8/16
Overview
The VIAVI dX3 400G 2-port module (DX3-QSFP-DD-2) is a single-slot QSFP-DD test module for the TestCenter chassis architecture. Each port can be configured for seven speeds, 400/200/100/50/40/25/10G, with PAM4 and NRZ encoding. Auto Negotiation and Link Training are supported at all speeds, including 8x50G mode.
The module installs in VIAVI SPT-N12U and SPT-N4U chassis. A single N12U holds up to 24 400G ports and an N4U holds 4. New hardware speed options are enabled by software license, without returning the module to the factory.
Key Features
- Complete 400G Ethernet testing across QSFP-DD interfaces
- Integrated Layer 2–3 validation on a single platform at full line rate
- Precise, repeatable latency, jitter, throughput, and loss measurements
- Validation of 100G/200G to 400G migration across multi-vendor ecosystems
- Regression testing for software, hardware, and topology changes
- 2 400G QSFP-DD ports per single-slot module
- Each port supports PAM4 1x400G, 2x200G, 4x100G, 8x50G
- Each port supports NRZ 2x100G, 4x50G, 2x40G, 8x25G, 8x10G
- 4x100G (QSFP28) operation with ACC-1067A accessory cable
- Ethernet FEC, Auto Negotiation and Link Training on all speeds including 8x50G mode
- Hardware speed option upgrades via licensing
- Protocol testing for L2/3 routing/switching and data center test cases
Specifications
| MSA interface | QSFP-DD |
|---|---|
| Operational modes | PAM4: 400/200/100/50G; NRZ: 100/50/40/25/10G |
| Per-port configurations | PAM4: 1x400G, 2x200G, 4x100G, 8x50G; NRZ: 2x100G, 4x50G, 2x40G, 8x25G, 8x10G |
| Maximum ports per slot (DX3-QSFP-DD-2-825A, -750A) | 2/4/8/16 |
| Maximum ports per SPT-N12U chassis (DX3-QSFP-DD-2-825A, -750A) | 24/48/96/192 |
| Maximum ports per SPT-N4U chassis (DX3-QSFP-DD-2-825A, -750A) | 4/8/16/32 |
| Maximum ports (DX3-QSFP-DD-2-400A) |
2 per slot; 24 per SPT-N12U; 4 per SPT-N4U
400G only
|
| Port CPU | Stackable multi-core CPU |
| User reservation | Per QSFP-DD port |
| Test port speed configuration | 2 test port speed groups per blade |
| Line clocking |
Stratum-3 rated oscillator is the default time source
Transmit line clock ± < 1 PPM on initial shipment; accurate to ± 4.6 PPM 15 years of operation
|
|---|---|
| Frame time-stamp resolution | 2.5ns |
| Inter-chassis synchronization |
± 20ns
Modules in the same chassis are phase-locked to the control module timing source
|
| Number of streams | Stats/Streams @400/200/100/50/40/25/10G: Tx=8k, Rx=16k |
|---|---|
| Frame transmit modes | Port-based (rate per port), stream-based (rate per stream), burst, timed |
| Min/max frame size (w/CRC) | 60 to 16,004 |
| Min/max Tx rates | 1 packet per 3.43 seconds to 101% of line rate |
| Per-stream latency statistics | Min, Max and Average Latency (4K streams) |
| Transmit timestamp resolution |
2.5 ns
With intra-chassis and inter-chassis synchronization
|
| Supported encapsulations | Layer 2: Ethernet II, 802.1Q, 802.1ad, FCoE; Layer 3/4: IPv4, IPv6, TCP, UDP |
| Capture buffer size | 8 MB per port |
| Latency modes |
LIFO, LILO, FIFO or FILO
Benchmark tests latency calculation methods
|
| Route Insertion Table (RIT) entries per port | 8K 4-byte entries for dynamic label or random IP/MAC address assignments |
| RIT or list VFD entries per stream | 8 RIT insertions per stream and 4 VFD insertions per stream |
| QSFP interconnects | SR, LR, FR, DR, PSM4 at multi-rate (400/200/100/50/40/25/10G) |
|---|---|
| PAM4 FEC | RS-FEC (544) KP all speeds |
| NRZ FEC |
Clause 74 BASE-R FEC, Clause 91 RS-FEC, and Clause 108 RS-FEC
NRZ support varies by module speed mode and license
|
| AN/LT (enable/disable) | Direct Attach Copper (DAC), AN/LT supported for all speeds including 8x50G mode |
| Layer-1 debug tools | CR Tx Emphasis settings, Rx Eye view, FEC Counters, PRBS Gen/Check, Front-end L1 Summary Status, Xcvr MDIO access |
| Module weight | 3.219 kg, 5.45lbs. |
|---|---|
| Module predicted MTBF | 56,330 hours of continuous operation |
| Operating temperature range |
41° to 95° F (5° to 35° C)
Ambient temperature; 20% to 80% relative humidity
|
| Max power draw per module | Maximum of 450W per slot |
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- Data center fabric validation
- Service provider and core network testing
- Interoperability and acceptance testing
- Pre-deployment and regression validation
- Cloud computing and streaming services
- Data center ToR and EoR switches and fabrics
- Terabit routers
Options & Accessories
| Option | Description |
|---|---|
| DX3-QSFP-DD-2-825A | dX3 400/200/100/50/40/25/10G QSFP-DD 2-Port |
| DX3-QSFP-DD-2-750A | dX3 400/200/100/50G QSFP-DD 2-Port |
| DX3-QSFP-DD-2-400A | dX3 400G QSFP-DD 2-Port |
| UPG-NRZ-DX3-400G-T2 | Factory Upgrade NRZ 400G QSFP-DD 2-Port — Requires 8x50G-AN/LT-compatible hardware |
| ACC-1067 | Active Copper Breakout QSFP-DD to 4XQSFP28 3M — High density 100G QSFP28; also requires BPK-1378 QSFP-DD to 4xQSFP28 chassis license |
| SPT-N12U-110 | N12U chassis and controller with 110VAC power supplies |
| SPT-N12U-220 | N12U chassis and controller with 220VAC power supplies |
| SPT-N12U-220-LC | N12U-LC chassis and controller with 220VAC power supplies |
| SPT-N4U-110 | N4U chassis and controller with 110VAC power supplies |
| SPT-N4U-220 | N4U chassis and controller with 220VAC power supplies |