SmartPocket V2 OLP-37XV2 Selective PON Power Meter
Wavelength-selective PON power meter that measures G/E-PON (1490 nm) and XGS-PON/10G-EPON (1577 nm) downstream power at the same time.
- Photo Diode
- InGaAs
- Spectral Range
- Passband (1260…1500 nm, 1540…1650 nm)
- Wavelength Setting
- 1490 nm, 1577 nm, Dual
- Wavelength Setting (Broadband)
- 1270…1650 nm, step size 1 nm
Overview
The VIAVI SmartPocket V2 OLP-37XV2 is a wavelength-selective Passive Optical Network (PON) power meter. It measures G/E-PON and XGS-PON/10G-EPON downstream power levels and loss in PON networks at the same time. It is built for field technicians who test, install and troubleshoot PON services, including in networks where G/E-PON and XGS-PON/10G-EPON services run side by side.
The instrument has a single mounted SC adapter. Through that one test port it measures the 1490 nm (G/E-PON) and 1577 nm (XGS-PON/10G-EPON) wavelengths selectively and simultaneously. An optional software license adds a Broadband Mode for general optical power measurement.
The meter has a backlit graphical display with context-sensitive softkeys and shows a clear pass/fail result. It switches on instantly with no boot time. It stores over 1000 test results, which can be downloaded to a PC or uploaded automatically over Bluetooth Low Energy through the VIAVI Mobile Tech App. It can run on alkaline AA batteries, NiMH AA rechargeable batteries, an AC power adapter or USB power. The recommended recalibration interval is three years.
Key Features
- Single test port connection for dual wavelength measurement
- Simultaneous power level measurements for both G/E-PON and XGS-PON/10G-EPON services
- Storage for over 1000 test results and PC download capability
- Bluetooth low energy connectivity to the VIAVI Mobile Tech App
- 4-way powering - alkaline AA, NiMH AA rechargeable, AC power adapter and power over USB
- 3-year recalibration period
- Instant On – no boot time
- High-visibility backlight graphical display with context-sensitive softkeys
- Clear pass/fail information
- Automatic upload of results via VIAVI Mobile Tech App
- Supports co-existence of G/E-PON and XGS-PON/10G-EPON services
- Low power consumption for extended continuous use
- Designed with outdoor environment in mind
Specifications
| Photo Diode | InGaAs |
|---|---|
| Spectral Range | Passband (1260…1500 nm, 1540…1650 nm) |
| Wavelength Setting | 1490 nm, 1577 nm, Dual |
| Wavelength Setting (Broadband) |
1270…1650 nm, step size 1 nm
in Broadband Mode (activated SW option required)
|
| Resolution | 0.01 dB, 0.001 µW |
| Measurement Range for Power Level | -45…+13 dBm |
| Max. Power Level (before damage) | +15 dBm |
| Measurement Uncertainty (1490 nm) |
±0.5 dB / ±12 %
under reference conditions: -2 dBm (CW), nominal wavelength, 23 °C ±3 K, 45 to 75 % relative humidity, SM test fiber (Single Mode, 9µm core, 8° APC), when used with SC/APC connectors
|
| Measurement Uncertainty (1577 nm) |
±0.5 dB / ±12 %
under reference conditions: -2 dBm (CW), nominal wavelength, 23 °C ±3 K, 45 to 75 % relative humidity, SM test fiber (Single Mode, 9µm core, 8° APC), when used with SC/APC connectors
|
| Measurement Uncertainty (Broadband) |
±0.5 dB / ±5 %
reference conditions as for 1490/1577 nm; in Broadband Mode (activated SW option required)
|
| Linearity |
±0.06 dB
under -50…+5 dBm, 0…+45 °C; for OLP-37XV2 in Broadband Mode (activated SW option required)
|
| Number of Calibrated Wavelengths | 2 (1490, 1577 nm) |
| Tone Detection |
CW, 270 Hz, 330 Hz, 1 kHz, 2 kHz
for OLP-37XV2 in Broadband Mode (activated SW option required); with VIAVI Light Source and received optical power level > -50 dBm
|
| Auto Functions |
Auto-λ / Multi-λ
when used with VIAVI Light Source and received optical power level > -50 dBm; for OLP-37XV2 in Broadband Mode (activated SW option required)
|
| Optical Connectors | 1x SC/APC |
| Data Storage | 1,000 Results |
|---|---|
| Data Download Capability | USB-C for PC/Laptop Transfer or BLE to StrataSync via MTA |
| Batteries | 2x Mignon (AA) Size |
|---|---|
| AC Operation | Via USB-C and Universal Power Adapter (Pmax.: 2.5 W) |
| Operating Time |
45 hrs.
continuous operation with dry batteries
|
| EMI/ESD | CE Compliant |
|---|---|
| Electromagnetic Compatibility | EN 61326-1:2013 |
| Device Safety | EN 61010-1:2010/A1:2019 |
| Recommended Calibration Interval | 3 Years |
| Operating Temperature | -10 to +55 °C (14 to 131 °F) |
| Storage Temperature | -20 to +70 °C (-4 to +158 °F) |
| Max. Altitude | 2,000 m (6,500 ft) |
| Pollution Degree | 2 |
| Ingress Protection | IP44 |
| Humidity |
15 to 85 % (Relative) up to +31 °C; 20 g/m3 (Absolute) > +31 °C
occasional condensation is tolerable as a limit condition
|
| Dimensions (H x W x D) | 30 x 80 x 150 mm (1.2 x 3.1 x 5.9 in) |
|---|---|
| Weight (w/o Batteries) | 200 g (0.45 lb) |
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- Measuring optical power levels for G/E-PON and XGS-PON/10G-EPON services
- Multi-service PON deployment and installs
- Enterprise/LAN network build and maintenance
- FTTA (fiber to the antenna) for 5G
- FTTH network build and maintenance
Included
- Instrument
- Switchable adapter
- Belt bag
- Neck strap
- Quick start guide
- Safety instructions
- Alkaline batteries
- USB cable
Options & Accessories
| Option | Description |
|---|---|
| OLP-37XV2 | OLP-37XV2 – Selective PON Power Meter SC mounted FC enclosed |
| 2335/94.01G | Broadband SW option for OLP-37XV2 via SmartReporter |
| 2335/94.01S | Broadband SW option for OLP-37XV2 via StrataSync and Mobile Tech App (MTA) — Requires StrataSync account |
| OLP-37XV2-INCL-BB | OLP-37XV2 and Broadband SW option (already installed) |
| 2302/90.02 | Calibration Report Power Meters (OLP-35V2/-35SC/-38V) and OLP-37XV2 |
| 2155/00.05 | Switchable Adapter FC/PC FC/APC for Light Sources and OLP-37XV2 |
| 2155/00.07 | Switchable Adapter LC/PC LC/APC for Light Sources and OLP-37XV2 |
| 2155/00.26 | Switchable Adapter SC/APC Spare for OLP-37XV2 |
| 2229/90.21 | OCK-10 Cleaning Kit complete |
| 22122619 | USB 2.0 Type A to Type C Cable |
| 2229/90.01 | 2x Alkaline Batteries Mignon AA-Size LR6 |
| 2237/90.02 | 2x Rechargeable batteries AA; NiMH; 1.2V; 2.6 / 2.7Ah |
| 2302/90.01 | Universal AC Power Adapter |