VIAVI SmartPocket V2 OLS-36V2 optical light source, front view
VIAVI / OLS-3xV2 / Optical Light Sources
OLS-36V2

SmartPocket V2 OLS-36V2 SM+MM Quad Optical Light Source 850/1300/1310/1550 nm

Pocket-sized VIAVI quad-wavelength light source covering multimode 850/1300 nm and single mode 1310/1550 nm.

Type
Class 1 Laser Product (IEC 60825-1:2007)
Short Term Stability
±0.02 dB within 15 min
Long Term Stability
±0.05 dB within 8 hrs.
Wavelengths (multimode)
850, 1300 nm
Datasheet

Overview

The VIAVI SmartPocket V2 OLS-36V2 is a small, rugged optical light source from the SmartPocket V2 OLS-3xV2 range. It is used for field insertion loss measurement and continuity checks on fiber optic networks.

The SmartPocket V2 light sources are designed to be used with the SmartPocket V2 OLP-3xV2 optical power meters for insertion loss and continuity testing. Together they cover single mode (SM) and multimode (MM) fiber networks. When paired with a SmartPocket V2 power meter, the source supports Auto-λ and Multi-λ modes. It can also generate tones that the meter detects for fiber tracing.

The instrument is pocket-sized and designed for outdoor use. It switches on instantly with no boot time and has a backlit graphical display with context-sensitive softkeys. It can run on alkaline AA batteries, NiMH AA rechargeable batteries, an AC power adapter or power over USB. Switchable optical adapter versions are available.

Key Features

  • Instant On with no boot time
  • Low power consumption for extended continuous use
  • Designed for outdoor environments
  • High-visibility backlit graphical display with context-sensitive softkeys
  • Fast Auto-λ and Multi-λ mode when paired with SmartPocket V2 optical power meters
  • Fiber tracing by generating light source tones for detection by SmartPocket V2 optical power meters
  • 4-way powering: alkaline AA, NiMH AA rechargeable, AC power adapter and power over USB
  • Switchable optical adapter versions available
  • Quad wavelength single mode (1310/1550 nm) and multimode (850/1300 nm)
  • Combines 4 wavelengths in one instrument (single mode + multimode)
  • SC mounted, FC enclosed

Specifications

Optical
Type Class 1 Laser Product (IEC 60825-1:2007)
Short Term Stability ±0.02 dB within 15 min
Long Term Stability ±0.05 dB within 8 hrs.
requires a warm-up time of 20 minutes and applies to a constant temperature
Wavelengths (multimode) 850, 1300 nm
Wavelengths (single mode) 1310, 1550 nm
Wavelength Accuracy (multimode) -20 / +40 nm
Wavelength Accuracy (single mode) ±20 nm
FWHM Spectral Width (multimode) < 170 nm
FWHM Spectral Width (single mode) < 5 nm
Output Level (CW) (multimode) Typ. -20 dBm
Output Level (CW) (single mode) Typ. -3 dBm
Optical Connectors 2x SC/PC
Power Supply
Batteries 2x Mignon (AA) Size
AC Operation Via USB-C and Universal Power Adapter (Pmax.: 2.5 W)
Operating Time 25 hrs.
continuous operation with dry batteries
Safety and Environmental Conditions
EMI/ESD CE Compliant
Electromagnetic Compatibility EN 61326-1:2013
Device Safety EN 61010-1:2010/A1:2019
Recommended Calibration Interval 3 Years
Operating Temperature -10 to +55 °C (14 to 131 °F)
Storage Temperature -20 to +70 °C (-4 to +158 °F)
Max. Altitude 2,000 m (6,500 ft)
Pollution Degree 2
Ingress Protection IP44
Humidity 15 to 85 % (Relative) up to +31 °C; 20 g/m3 (Absolute) > +31 °C
occasional condensation is tolerable as a limit condition
Physical
Dimensions (H x W x D) 30 x 80 x 150 mm (1.2 x 3.1 x 5.9 in)
Weight (w/o Batteries) 200 g (0.45 lb)

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • Optical power level and link insertion loss measurement with optical power meters
  • Continuity checks
  • Enterprise/LAN network build and maintenance
  • Access and Metro (LAN/WAN) network build and maintenance
  • FTTx (e.g. Home/Antenna) network build and maintenance

Included

  • Instrument
  • Switchable adapter
  • Belt bag
  • Neck strap
  • Quick start guide
  • Safety instructions
  • Alkaline batteries

Options & Accessories

Option Description
2303/90.01 Calibration Report Light Sources (OLS-34V2/-35V2/-36V2/-38V2)
2155/00.05 Switchable Adapter FC/PC FC/APC for Light Sources and OLP-37XV2
2155/00.06 Switchable Adapter SC/PC for Spare Light Sources
2155/00.07 Switchable Adapter LC/PC LC/APC for Light Sources and OLP-37XV2
2155/00.32 Switchable Adapter ST/PC for Light Sources
2229/90.21 OCK-10 Cleaning Kit complete
22122619 USB 2.0 Type A to Type C Cable
2229/90.01 2x Alkaline Batteries Mignon AA-Size LR6
2237/90.02 2x Rechargeable batteries AA; NiMH; 1.2V; 2.6 / 2.7Ah
2302/90.01 Universal AC Power Adapter