VIAVI / Attenuators / Handheld
SmartClass OLA-54

VIAVI SmartClass OLA-54 Multimode Optical Level Attenuator

Handheld variable optical level attenuator for 50/125 µm multimode fiber systems, with absolute or relative setting from 750 to 1350 nm.

Order number
BN 2280/41 Multimode
Table adjustable wavelength range
750 to 1350 nm in 1 nm increments
Fiber type
50/125 µm
Calibrated wavelengths
850 nm, 1300 nm
Datasheet

Overview

The VIAVI SmartClass OLA-54 is a handheld optical level attenuator designed for multimode fiber systems using 50/125 µm fiber. It is part of the VIAVI SmartClass family of optical handhelds, which are used to test optical signals and systems including broadband, PONs and Gigabit Ethernet.

The instrument has a table-adjustable wavelength range of 750 to 1350 nm in 1 nm increments, with calibrated wavelengths at 850 nm and 1300 nm. Attenuation is set continuously over the entire range using a wheel for manual setting, and the displayed value can be shown as an absolute or relative attenuation. The attenuator works bi-directionally.

The SmartClass optical handhelds share a graphical user interface, a power supply management system, a belt bag for hands-free operation and transport, and a shock-proof, splash-proof design for field use. Measurements are traceable to international standards, and the instruments need no warm-up time.

The OLA-54 runs on four AA dry batteries or NiMH rechargeable cells, with an integrated fast charging function, and can also be powered from an AC adapter or a 12 V car battery adapter. The optical interface accepts interchangeable adapters from the BN 2155/00.xx range.

Key Features

  • 50/125 µm multimode fiber design
  • New optical design allowing for low minimum insertion loss
  • Wheel for precise and fast manual setting
  • Absolute and relative attenuation setting
  • FTTx ready
  • Illuminated graphical display (128 x 64 dots) showing up to three results simultaneously
  • Switchable display backlight
  • Auto power-off after approximately 20 min (can be disabled)
  • Shock-proof and splash-proof design for field operation
  • No warm-up time required
  • Traceable measurements to international standards
  • Interchangeable optical adapters for flat or angled physical contact systems

Specifications

Optical
Order number BN 2280/41 Multimode
Table adjustable wavelength range 750 to 1350 nm in 1 nm increments
Fiber type 50/125 µm
Calibrated wavelengths 850 nm, 1300 nm
Display range <2.5 to 55 dB
Including connectors (to IEC874-1, method 6), depending on quality of the connectors applied to the OLA
Minimum insertion loss <2.5 dB
Including connectors (to IEC874-1, method 6), depending on quality of the connectors applied to the OLA
Linearity ± 0.2
Repeatability of attenuation setting ± 0.1 dB
Excluding remating
Total attenuation accuracy typ. ± 0.8 dB
Including connectors (to IEC874-1, method 6), depending on quality of the connectors applied to the OLA
Setting type Continuous over the entire range
Function Bi-directional
Displayed value Absolute or relative attenuation value
Including connectors (to IEC874-1, method 6), depending on quality of the connectors applied to the OLA
Max. permitted level +20 dBm
Display
Display Illuminated graphical display, resolution of 128 × 64 dots
Results displayed in dB
Backlight Backlight function switchable via a separate key
Connector
Optical connector Interchangeable adapter from BN 2155/00.xx range
Suitable for measurements on flat or angled physical contact systems
Power Supply
Batteries Four dry batteries Mignon/AA, 1.5 V or NiMH rechargeable cells Mignon/AA, 1.2 V
Operating time from dry batteries >300 h
Power saving The instrument switches off automatically after ~20 min
Function can be disabled
AC line operation Via separate AC adapter
Battery charging Integrated fast battery charging function (2 hours)
External DC operation External 12 V DC operating via an AC adapter or a 12 V car battery adapter
General
Electromagnetic compatibility Corresponds to IEC 61326 (CE conformance)
Suggested calibration interval 3 years
Environmental
Nominal range of use −10°C to +55°C
Ambient temperature
Storage and transport −40°C to +70°C
Ambient temperature
Physical
Dimensions (W × H × D) 95 × 60 × 195 mm (3.74 × 2.36 × 7.68 in)
Approximately
Weight 500 g (1.1 lb)
Approximately

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • Multimode fiber system testing
  • Installation and maintenance of multimode fiber links
  • FTTx testing
  • Broadband and Gigabit Ethernet optical testing

Options & Accessories

Option Description
BN 2155/00.32 Optical adapter ST type
BN 2155/00.06 Optical adapter SC/PC type
BN 2155/00.05 Optical adapter FC type
BN 2155/00.26 Optical adapter SC/APC type
BN 2155/00.07 Optical adapter LC type
BN 2252/01 OVF-1 Visual Fault Locator
BN 2229/90.21 OCK-10 Optical Connector Cleaning Kit
BN 2229/90.07 Optical cleaning tape
BN 2229/90.08 Spare tape for optical cleaning tape
BN 2237/90.02 NiMH cells, Mignon/AA, 1.2 V — 4 required per instrument
BN 2277/90.01 SNT-121A Worldwide compatible AC adapter
K804 USB connection cable
BN 2277/90.02 MT-1S belt bag for one instrument
BN 2126/03 MT-2S soft bag for two instruments
BN 2126/04 MT-3S soft bag for three instruments
BN 2093/31 MK-3S hard case for three instruments
BN 2280/90.01 Calibration Report

Documents & Resources