8100-Series OTDR EVO E8126D 1310/1550 nm OTDR Module for OneAdvisor 800 Fiber
Dual-wavelength 1310/1550 nm 8100D OTDR EVO module for the OneAdvisor 800 Fiber platform with up to 50 dB dynamic range and integrated source and power meter.
- Weight
- approx. 500 g (1.1 lb)
- Dimensions (W x H x D)
- 213 x 124 x 32 mm (8.38 x 4.88 x 1.26 in)
- Laser safety class (21 CFR)
- Class 1
- Distance units
- Kilometer, meter, feet, and miles
Overview
The VIAVI E8126D is the 1310/1550 nm dual-wavelength member of the 8100-Series OTDR EVO (8100D) module family for the OneAdvisor 800 Fiber platform. The 8100D modules are designed for testing single-mode standard and hollow core fibers across metro, long-haul and ultra-long-haul networks during installation, turn-up and maintenance, and they can be connected anywhere on the fiber for commissioning, network upgrades and troubleshooting.
The module combines an OTDR, a continuous-wave light source and a broadband power meter on a single optical port. Automatic traffic detection checks for live signals before an acquisition starts, which reduces the risk of interfering with traffic or damaging an optical transmitter. The dead-zone performance allows full characterization of adjacent elements on a link a few meters apart, and the OTDR is optimized for PON testing through splitters up to 1x128.
Software and analysis
Smart Link Mapper (SLM) presents the trace as an icon-based link map to reduce interpretation errors without extending test time. Standard testing features include automatic macrobend detection, a summary results table with pass/fail analysis and onboard FastReport report generation. A hollow core fiber mode characterizes the solid-core to hollow-core transition and provides dynamic range figures specific to hollow core fiber.
Key Features
- Up to 50 dB dynamic range and 256,000 acquisition points
- ≤ 65 cm event dead zone and 2.5 m attenuation dead zone
- Integrated CW light source and broadband power meter on the OTDR port (single-mode wavelengths)
- PON optimized to test through a 1x128 splitter
- Dual-wavelength 1310/1550 nm module in the 8100D family
- Single connector port for 1310 and 1550 nm wavelengths
- Instantaneous automatic traffic detection before an OTDR test
- Smart Link Mapper (SLM) icon-based results to eliminate OTDR interpretation errors
- Automatic macrobend detection
- Summary results table with pass/fail analysis
- FastReport onboard report generation
- Characterization of single-mode standard and hollow core fibers
Specifications
| Weight | approx. 500 g (1.1 lb) |
|---|---|
| Dimensions (W x H x D) | 213 x 124 x 32 mm (8.38 x 4.88 x 1.26 in) |
| Laser safety class (21 CFR) | Class 1 |
| Distance units | Kilometer, meter, feet, and miles |
| Group index range | 1.00000 to 1.70000 in 0.00001 steps |
| Number of data points | Up to 256,000 data points |
| Platform | OneAdvisor 800 Fiber |
| Mode | Automatic or dual cursor |
|---|---|
| Display range |
0.1 - 400 km
Single-mode
|
| Display resolution | 1 cm |
| Cursor resolution | From 1 cm |
| Sampling resolution | From 4 cm |
| Accuracy |
± (0.75 m + sampling resolution + 0.001% x distance)
Single-mode; excluding group index uncertainties
|
| Mode | Automatic, manual, 2-point, 5-point, and LSA |
|---|---|
| Display resolution | 0.001 dB |
| Linearity |
±0.03 dB/dB
Single-mode
|
| Threshold | 0.01 to 4.99 dB in 0.01 dB steps |
| Mode | Automatic or manual |
|---|---|
| Reflectance accuracy | ±2 dB |
| Display resolution | 0.01 dB |
| Threshold | -11 to -99 dB in 1 dB steps |
|
Wavelengths
E8126D
|
1310/1550 nm
E8126D is the 1310/1550 nm OTDR module (ordering information)
|
|---|---|
| Central wavelength |
1310 ±20 nm; 1550 ±20 nm; 1625 +15/-5 nm; 1650 ±1 nm
Laser at 25°C and measured at 10 µs; 8100D family figures, E8126D provides 1310 and 1550 nm
|
| Dynamic range |
50/50/50/48 dB
Per wavelength 1310/1550/1625/1650 nm. One-way difference between the extrapolated backscattering level at the start of the fiber and the RMS (SNR=1) noise level, after 3 minutes averaging using the largest pulse width
|
| Pulse width | 2 ns to 20 µs |
| Event dead zone |
0.5 m
Measured at ±1.5 dB below the peak of an unsaturated reflective event using the shortest pulse width
|
| Attenuation dead zone |
2.5 m
Measured ±0.5 dB from the linear regression using an FC/UPC reflectance and the shortest pulse width
|
| Splitter attenuation dead zone | 15 m after a 15 dB splitter loss |
| Dynamic range |
35/35/35/33 dB
Per wavelength 1310/1550/1625/1650 nm; same measurement condition as the solid core dynamic range
|
|---|---|
| Solid core to hollow core transition attenuation dead zone |
15 m after a 15 dB Rayleigh backscattering difference
Measured on a none reflective transition at 100 ns, after a 15 dB Rayleigh backscattering difference between solid core fiber and hollow core fiber
|
| Calibrated wavelengths |
1310/1490/1550/1625 nm
Power meter available on the E8126D (not available on single-wavelength and 1550/1625 nm versions)
|
|---|---|
| Power range | -5 to -55 dBm |
| Accuracy |
±0.5 dB at -30 dBm
At calibrated wavelengths
|
| Wavelengths |
1310/1550/1625 nm
At calibrated wavelengths; light source available on the E8126D (not available on single-wavelength and 1550/1625 nm versions)
|
|---|---|
| Output power | 0 dBm |
| Stability | ±0.1 dB at 25°C over 1 hour |
| Operating modes |
270 Hz, 330 Hz, 1 kHz, 2 kHz, TWINtest
Subtract 3 dB when in modulation mode (270 Hz/330 Hz/1 kHz/2 kHz)
|
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- Metro, long-haul and ultra-long-haul fiber network characterization
- Access network characterization
- Advanced FTTH PON network qualification and troubleshooting
- Fiber monitoring in and out of service
- Fiber installation/deployment certification and troubleshooting for submarine cable networks
- Hollow core fiber test and certification for high-speed networks and data center interconnects
- Upgrading core fiber networks up to 800G
Options & Accessories
| Option | Description |
|---|---|
| EUNIPCFC | Universal optical connector, straight, FC — Straight universal optical connector |
| EUNIPCSC | Universal optical connector, straight, SC — Straight universal optical connector |
| EUNIPCST | Universal optical connector, straight, ST — Straight universal optical connector |
| EUNIPCDIN | Universal optical connector, straight, DIN — Straight universal optical connector |
| EUNIAPCFC | Universal optical connector, 8° angled, FC — 8° angled universal optical connector |
| EUNIAPCSC | Universal optical connector, 8° angled, SC — 8° angled universal optical connector |
| EUNIAPCDIN | Universal optical connector, 8° angled, DIN — 8° angled universal optical connector |
| ELCSMXX-YY-ZZ | Launch and receive cable, single-mode — XX: fiber length in meters (20, 25, 100, 150, 500, 1000, 2000, 2200); YY: connector A type (SCA, LC, MPO); ZZ: connector B type (SC, SCA, LC, MPO). MPO versions available in 20 m or 25 m only. |