8100-Series OTDR EVO E81162D In-Service 1625 nm OTDR Module
In-service 1625 nm OTDR module of the VIAVI 8100-Series OTDR EVO family for the OneAdvisor 800 Fiber platform.
- Central wavelength
- 1625 +15/–5 nm
- Dynamic range
- 50/50/50/48 dB
- Pulse width
- 2 ns to 20 µs
- Event dead zone
- 0.5 m
Overview
The VIAVI E81162D is the in-service 1625 nm OTDR module of the 8100-Series OTDR EVO family (8100D), designed for the OneAdvisor 800 Fiber platform. The 8100D module is intended for testing single-mode standard and hollow-core fibers across metro, long-haul and ultra-long-haul infrastructures during installation, turn-up and maintenance.
The OTDR EVO family can be connected anywhere on the fiber to characterize single-mode and hollow core fibers for commissioning, network upgrades and troubleshooting. Dead zone performance allows full characterization of element events on a fiber link that are 2 meters apart, and automatic traffic detection avoids the risk of live signal interference or damage to the optical transmitter when an OTDR test is performed on an in-service fiber.
Smart Link Mapper (SLM) reduces OTDR interpretation errors without compromising test time. Standard testing features include automatic macrobend detection, a summary results table with pass/fail analysis and FastReport onboard report generation.
The E81162D is a 1625 nm-only version; according to the manufacturer's ordering information, the integrated light source and power meter are not available on this version.
Key Features
- Up to 50 dB dynamic range and 256,000 acquisition points
- In-service 1625 nm OTDR wavelength
- ≤ 65 cm Event Dead Zone and 2.5 m Attenuation Dead Zone
- Full characterization of element events on a fiber link 2 meters apart
- Instantaneous automatic traffic detection to avoid live signal interference or optical transmitter damage
- PON optimized to test up to 1x128 splitter type
- Smart Link Mapper (SLM) eliminates OTDR interpretation errors without compromising test time
- Reduces event loss measurement uncertainty and improves measurement repeatability
- Automatic macrobend detection
- Summary results table with pass/fail analysis
- FastReport onboard report generation
- Module for the OneAdvisor 800 Fiber platform
Specifications
|
Central wavelength
E81162D
|
1625 +15/–5 nm
Laser at 25°C and measured at 10 µs
|
|---|---|
| Dynamic range |
50/50/50/48 dB
8100D values for 1310/1550/1625/1650 nm; one-way difference between the extrapolated backscattering level at the start of the fiber and the RMS (SNR=1) noise level, after 3 minutes averaging using the largest pulse width
|
| Pulse width | 2 ns to 20 µs |
| Event dead zone |
0.5 m
Measured at ±1.5 dB below the peak of an unsaturated reflective event using the shortest pulse width; web page states ≤ 65 cm
|
| Attenuation dead zone |
2.5 m
Measured ±0.5 dB from the linear regression using an FC/UPC reflectance and the shortest pulse width
|
| Splitter attenuation dead zone | 15 m after a 15 dB splitter loss |
| Dynamic range |
35/35/35/33 dB
One-way difference between the extrapolated backscattering level at the start of the fiber and the RMS (SNR=1) noise level, after 3 minutes averaging using the largest pulse width
|
|---|---|
| Solid core to hollow core transition attenuation dead zone |
15 m after a 15 dB Rayleigh backscattering difference
Measured on a none reflective transition at 100 ns, after a 15 dB Rayleigh backscattering difference between solid core fiber and hollow core fiber
|
| Mode | Automatic or dual cursor |
|---|---|
| Display range | Single-mode: 0.1 – 400 km |
| Display resolution | 1 cm |
| Cursor resolution | From 1 cm |
| Sampling resolution | From 4 cm |
| Accuracy |
Single-mode: ± (0.75 m + sampling resolution + 0.001% x distance)
Excluding group index uncertainties
|
| Mode | Automatic, manual, 2-point, 5-point, and LSA |
|---|---|
| Display resolution | 0.001 dB |
| Linearity | Single-mode: ±0.03 dB/dB |
| Threshold | 0.01 to 4.99 dB in 0.01 dB steps |
| Mode | Automatic or manual |
|---|---|
| Reflectance accuracy | ±2 dB |
| Display resolution | 0.01 dB |
| Threshold | –11 to –99 dB in 1 dB steps |
| Weight | approx. 500 g (1.1 lb) |
|---|---|
| Dimensions (W x H x D) | 213 x 124 x 32 mm (8.38 x 4.88 x 1.26 in) |
| Laser safety class (21 CFR) | Class 1 |
| Distance units | Kilometer, meter, feet, and miles |
| Group index range | 1.00000 to 1.70000 in 0.00001 steps |
| Number of data points | Up to 256,000 data points |
| Specification conditions | Typical at 25°C |
| Platform | OneAdvisor 800 Fiber platform |
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- Metro, long haul and ultra long haul fiber network characterization
- Access network characterization
- Advanced FTTH PON network qualification and troubleshooting
- Fiber monitoring in and out of service
- Fiber installation/deployment certification and troubleshooting for submarine cable networks
- Hollow core fiber test and certification for high-speed networks and data center interconnects
- Upgrading core fiber networks up to 800G
Options & Accessories
| Option | Description |
|---|---|
| EUNIPCFC | Universal optical connector, straight, FC |
| EUNIPCSC | Universal optical connector, straight, SC |
| EUNIPCST | Universal optical connector, straight, ST |
| EUNIPCDIN | Universal optical connector, straight, DIN |
| EUNIAPCFC | Universal optical connector, 8° angled, FC |
| EUNIAPCSC | Universal optical connector, 8° angled, SC |
| EUNIAPCDIN | Universal optical connector, 8° angled, DIN |
| ELCSMXX-YY-ZZ | OTDR launch cable, single-mode — XX: fiber length in meters (20, 25, 100, 150, 500, 1000, 2000, 2200); YY: connector A type (SCA, LC, MPO); ZZ: connector B type (SC, SCA, LC, MPO). Launch cables with MPO connectors are only available in 20 m or 25 m versions. |