VIAVI 8100-Series OTDR EVO module for the OneAdvisor 800 Fiber platform
VIAVI / 8100D / OTDR Modules
E8115D

8100-Series OTDR EVO E8115D 1550 nm OTDR Module

Single-wavelength 1550 nm OTDR EVO module for the OneAdvisor 800 Fiber platform, for metro, long-haul and ultra-long-haul fiber testing.

Platform
For OneAdvisor 800 Fiber platform
Weight
approx. 500 g (1.1 lb)
Dimensions (W x H x D)
213 x 124 x 32 mm (8.38 x 4.88 x 1.26 in)
Laser safety class (21 CFR)
Class 1
Datasheet

Overview

The VIAVI 8100-Series OTDR EVO family is a range of OTDR modules for the OneAdvisor 800 Fiber platform. The 8100D module is designed for high-performance optical networks and tests single-mode standard fibers and hollow core fibers across metro, long-haul and ultra-long-haul infrastructures, including submarine cable networks.

The modules can be connected anywhere on the fiber to characterize the link for commissioning, network upgrades and troubleshooting. Automatic traffic detection checks for live signals before an acquisition to avoid interference with traffic or damage to the optical transmitter. Smart Link Mapper (SLM) presents results as a link map to reduce OTDR interpretation errors without extending test time, and the dead zone performance allows full characterization of element events on a fiber link 2 meters apart.

Standard testing features include automatic macrobend detection, a summary results table with pass/fail analysis and FastReport onboard report generation. The family is PON-optimized to test through a 1x128 splitter and is available in single-, dual- and tri-wavelength versions at 1310, 1550, 1625 and 1650 nm, with a single connector port for 1310, 1550 and in-service 1650 nm wavelengths. Versions with an integrated continuous-wave light source and broadband power meter on the OTDR port are available for single-mode wavelengths.

Key Features

  • Up to 50 dB dynamic range
  • Up to 256,000 acquisition points
  • 0.5 m event dead zone and 2.5 m attenuation dead zone
  • Dead zone performance allows full characterization of element events on a fiber link 2 meters apart
  • Instantaneous automatic traffic detection avoids live signal interference or optical transmitter damage during an OTDR test
  • Smart Link Mapper (SLM) eliminates OTDR interpretation errors without compromising on test time
  • Reduces event loss measurement uncertainty and improves measurement repeatability
  • PON optimized to test up to 1x128 splitter type
  • Characterizes single-mode standard and hollow core fibers
  • Single-/dual-/tri-wavelength versions with 1310, 1550, 1625 and 1650 nm
  • Single connector port for 1310, 1550 and in-service 1650 nm wavelengths
  • Automatic macrobend detection
  • Summary results table with pass/fail analysis
  • FastReport onboard report generation
  • Module for the OneAdvisor 800 Fiber platform

Specifications

General
Platform For OneAdvisor 800 Fiber platform
Weight approx. 500 g (1.1 lb)
Dimensions (W x H x D) 213 x 124 x 32 mm (8.38 x 4.88 x 1.26 in)
Laser safety class (21 CFR) Class 1
Distance units Kilometer, meter, feet, and miles
Group index range 1.00000 to 1.70000 in 0.00001 steps
Number of data points Up to 256,000 data points
Part number E8115D
1550 nm OTDR module. Source and power meter not available on this version
Distance Measurements
Mode Automatic or dual cursor
Display range Single-mode: 0.1 – 400 km
Display resolution 1 cm
Cursor resolution From 1 cm
Sampling resolution From 4 cm
Accuracy Single-mode: ± (0.75 m + sampling resolution + 0.001% x distance)
Excluding group index uncertainties
Attenuation Measurements
Mode Automatic, manual, 2-point, 5-point, and LSA
Display resolution 0.001 dB
Linearity Single-mode: ±0.03 dB/dB
Threshold 0.01 to 4.99 dB in 0.01 dB steps
Reflectance/ORL Measurements
Mode Automatic or manual
Reflectance accuracy ±2 dB
Display resolution 0.01 dB
Threshold –11 to –99 dB in 1 dB steps
OTDR
Dynamic range 50/50/50/48 dB
For 1310/1550/1625/1650 nm. One-way difference between the extrapolated backscattering level at the start of the fiber and the RMS (SNR=1) noise level, after 3 minutes averaging using the largest pulse width
Pulse width 2 ns to 20 µs
Event dead zone 0.5 m
Measured at ±1.5 dB below the peak of an unsaturated reflective event using the shortest pulse width. Web page states ≤ 65 cm
Attenuation dead zone 2.5 m
Measured ±0.5 dB from the linear regression using an FC/UPC reflectance and the shortest pulse width
Splitter attenuation dead zone 15 m after a 15 dB splitter loss
Central wavelength 1550 ±20 nm
Laser at 25°C and measured at 10 µs
OTDR (Hollow Core Fiber)
Dynamic range 35/35/35/33 dB
For 1310/1550/1625/1650 nm. One-way difference between the extrapolated backscattering level at the start of the fiber and the RMS (SNR=1) noise level, after 3 minutes averaging using the largest pulse width
Solid core to hollow core transition attenuation dead zone 15 m after a 15 dB Rayleigh backscattering difference
Measured on a non-reflective transition at 100 ns, after a 15 dB Rayleigh backscattering difference between solid core fiber and hollow core fiber

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • Access, metro, long-haul and ultra-long-haul fiber network characterization
  • Advanced FTTH PON network qualification and troubleshooting
  • Hollow core fiber test and certification for high-speed networks and data center interconnects
  • Upgrading core fiber networks up to 800G
  • Remote fiber monitoring in and out of service
  • Fiber installation/deployment certification and troubleshooting for submarine cable networks

Options & Accessories

Option Description
EUNIPCFC Universal optical connector, straight, FC — Straight (PC) universal optical connector
EUNIPCSC Universal optical connector, straight, SC — Straight (PC) universal optical connector
EUNIPCST Universal optical connector, straight, ST — Straight (PC) universal optical connector
EUNIPCDIN Universal optical connector, straight, DIN — Straight (PC) universal optical connector
EUNIAPCFC Universal optical connector, 8° angled, FC — 8° angled (APC) universal optical connector
EUNIAPCSC Universal optical connector, 8° angled, SC — 8° angled (APC) universal optical connector
EUNIAPCDIN Universal optical connector, 8° angled, DIN — 8° angled (APC) universal optical connector