Anritsu MA8161A Shield Box, angled view
MA8161A

Anritsu MA8161A Shield Box for 5G NR Sub-6 GHz and mmWave OTA Protocol Testing

Benchtop shield box providing a simple OTA test environment for 5G/LTE protocol tests from 600 MHz to 6 GHz and 24 GHz to 43.5 GHz.

Frequency
600 MHz to 6 GHz, 24 GHz to 43.5 GHz
System
5G NR

Overview

The Anritsu Shield Box MA8161A provides a simple over-the-air (OTA) environment for mmWave protocol testing, supporting frequencies between 600 MHz and 43.5 GHz. It covers both sub-6 GHz and mmWave bands, so the same enclosure can be used across 5G NR and LTE test cases.

The unit is intended for 5G/LTE protocol R&D tests and PCT/CAT pre-tests, as well as regression testing during the 5G UE development stage. Typical use cases include protocol functional tests, throughput tests and debugging.

The MA8161A has a small footprint for benchtop use and easy handling. With Connector Panel 2 (MA8161A-002) fitted, the box provides SMA and K-type feed-through connectors and through holes for cabling to the test equipment. It is part of the Anritsu OTA product line, alongside the RF Chamber MA8171A and the CATR Anechoic Chambers MA8172A and MA8172B.

Key Features

  • Simple OTA test environment for 5G/LTE protocol R&D tests and PCT/CAT pre-tests
  • Supports both sub-6 GHz and mmWave bands
  • Frequency coverage of 600 MHz to 6 GHz and 24 GHz to 43.5 GHz
  • Small footprint for easy benchtop use and good handling
  • Suited to regression testing during the 5G UE development stage
  • Shielding of ≥50 dB across supported bands
  • Optional Connector Panel 2 with 8 SMA (f) and 8 K (f) feed-through connectors

Specifications

Frequency
Frequency 600 MHz to 6 GHz, 24 GHz to 43.5 GHz
System 5G NR
Electrical Characteristics
Shielding characteristics ≥50 dB (600 MHz ≤ frequency ≤ 6 GHz)
Without cable connection via USB connector or Through Hole
Shielding characteristics ≥50 dB (24 GHz < frequency ≤ 43.5 GHz) (nom.)
Without cable connection via USB connector or Through Hole
Input/Output Connector
SMA (f) ― SMA (f)
MA8161A-002
8
When Connector Panel 2 MA8161A-002 is selected
K (f) ― K (f)
MA8161A-002
8
When Connector Panel 2 MA8161A-002 is selected
Through Hole
MA8161A-002
2
When Connector Panel 2 MA8161A-002 is selected
Dimensions and Mass
Outer dimensions 434 (W) × 271 (H) × 328 (D) mm
Excluding projections
Mass ≤16 kg
Full option configuration
Maximum test UE size 300 (W) × 15 (H) × 200 (D) mm
Set the UE antenna face down
Maximum test UE mass ≤1 kg
Ventilation hole 2
Environmental Conditions
Operating temperature range +5°C to +40°C
Storage temperature range –20°C to +60°C
Without condensation
Compliance
CE RoHS 2011/65/EU, (EU) 2015/863, EN IEC 63000: 2018
UKCA RoHS S.I. 2012 No.3032, EN IEC 63000: 2018

Applications

  • Protocol functional test
  • Throughput test
  • Debug
  • Regression test
  • 5G/LTE protocol R&D
  • PCT/CAT pre-tests
  • 5G UE development

Options & Accessories

Option Description
MA8161A-002 Control Panel 2 — Connector panel providing SMA (f) connector × 8, K (f) connector × 8 and through hole × 2 (referred to as Connector Panel 2 in the specifications)
MA8161A-AK010 Shield Tube
Z1999A 28 GHz Antenna Unit
Z2000A 39 GHz Antenna Unit
K241C Precision Power Splitter, DC to 40 GHz

Documents & Resources