Anritsu MW90010B Coherent OTDR, front view
MW90010B

Anritsu Coherent OTDR MW90010B for Submarine Cable Fault Location

Coherent OTDR for locating faults in submarine cables up to 20,000 km, with 10 m resolution and a built-in C-band tunable light source.

Fiber Under Test
ITU-T G.653 (DSF)
Optical Connector
FC, SC (Replaceable, PC type)
Wavelength (Probe Light)
1,527.60 nm to 1,567.13 nm
Wavelength Accuracy
±0.05 nm

Overview

The Anritsu MW90010B is a coherent optical time domain reflectometer (C-OTDR) for finding faults in very long optical submarine cables that use EDFA (Erbium-Doped Fiber Amplifier) repeaters. It measures cables up to 12,000 km as standard. The Extended Measurement Distance option MW90010B-003 raises this to 20,000 km. Sampling resolution stays at 10 m across the whole distance range.

Measurement principle

The C-OTDR sends an optical pulse into one end of the cable. It then analyzes the backscatter and Fresnel reflection that return to the instrument. EDFAs also emit amplified spontaneous emission (ASE). To keep sensitivity high despite this, the instrument uses coherent detection: it detects the beat signal between the backscattered light and a local reference light. From the captured waveform it can determine fault location, cable loss, bending loss and fiber length. The dynamic range is enough to measure systems with repeaters spaced 80 km or more apart.

Tunable light source

A built-in tunable light source covers the C-band from 1527.60 nm to 1567.13 nm in 50 GHz ITU-T grid steps, with ±0.05 nm wavelength accuracy. This allows testing of DWDM submarine cables and of paths that branch by wavelength. A dummy loading light can be set at +50 GHz or −50 GHz from the probe wavelength.

Operation and data handling

A measurement is started in three steps: set the wavelength, set the measurement conditions, start. The instrument shows the estimated time remaining. Additional averaging can be added after a measurement has finished. Up to 8 waveforms can be shown at once, for example to compare an installation trace with a fault trace. Results can be saved in GR-196 and SR-4731 (Telcordia) formats or as PDF reports, on 350 GB of internal memory. The unit can be controlled remotely by commands or through Windows Remote Desktop. Saved waveforms can be analyzed on a PC with the optional NETWORKS emulation software (version 4.1 or newer).

Key Features

  • Covers C-band wavelengths from 1527.60 nm to 1567.13 nm
  • Built-in tunable light source with ±0.05 nm wavelength accuracy
  • Standard 12,000 km distance range, extendable to 20,000 km with option MW90010B-003
  • 10 m sampling resolution across the full distance range
  • Coherent detection for measurement through EDFA-repeatered submarine cables
  • Simultaneous display of up to 8 waveforms
  • Additional averaging after a measurement has completed
  • Simple three-step measurement setup with estimated time to completion
  • Built-in OTDR functions including real-time measurement, zoom/shift and 2-point loss analysis
  • Telcordia SR-4731 file format support
  • 350 GB internal memory for up to 3.5 million measurement files
  • PDF-format measurement reports
  • Remote control by external commands and Windows Remote Desktop
  • Portable at ≤10 kg mass

Specifications

Optical
Fiber Under Test ITU-T G.653 (DSF)
Optical Connector FC, SC (Replaceable, PC type)
Wavelength (Probe Light) 1,527.60 nm to 1,567.13 nm
ITU-T Grid, Wavelength in vacuum setting with 50 GHz steps
Wavelength Accuracy ±0.05 nm
+20°C to +30°C
Warm-up Time 2 minutes
+20°C to +30°C
Loading Light Source (Dummy) wavelength of probe light +50 GHz or –50 GHz
The loading wavelength can be selectable at +50 GHz or –50 GHz of the probe (OTDR) wavelength
Pulse Width 3, 10, 30, 60, 100 μs
Optical Output Power 0 to +13 dBm, 0.5 dB steps
Monitor Output –25 to –15 dBm
for OTDR Wavelength Monitor
Measurement
Dynamic Range (one way, S/N = 1) >18 dB typ.
25°C; Pulse width: 10 μs, Average times: 2^16, Distance range: 1000 km, Smoothing: On, Ps: –57 dBm @ Pin, Pase: –20 dBm/nm @ Pin. Product introduction lists standard value >17 dB
Dead Zone 0.5 km
Pulse width: 3 μs
Distance Measurement Accuracy ±10 m ±0.5 × 10^–6 × measurement value (m)
Does not include optical fiber refraction index (IOR) based uncertainty
Distance Range 100 km, 500 km to 12,000 km (in 500 km steps)
Distance Range
MW90010B-003
100 km, 500 km to 20,000 km (in 500 km steps)
With option MW90010B-003
Sampling Resolution 10 m
IOR = 1.500000
Measurement Time 15 minutes
Distance range: 1000 km, Average times: 2^16
Average Times 2^8 to 2^24
IOR Settings 1.300000 to 1.700000 (0.000001 steps)
Vertical Scale 0.02, 0.05, 0.1, 0.2, 0.5, 1.0, 2.0, 5.0, 10.0 dB/div
Functions
Measurement Functions Real Time Measurement, Multiple Trace Display (8 Waveforms max.), Zoom & Shift
Loss Calculation Splice Loss, 2Pt Loss, 2Pt LSA, dB/km Loss, dB/km LSA, 2Pt & dB/km, 2Pt & dB/km LSA
File Save Formats GR-196, SR4731
Internal Memory 350 GB
Print External printer, Hard copy (file: PDF)
Distance Unit miles, feet, kilofeet, meters, kilometers
File Utility File: Copy, Paste, Delete, Folder: Create new
Other Help function, Remote Control Function
General
Display 8.4 inch, XGA (1024 × 768) color LCD with touch panel
OS Windows 10 IoT Enterprise 2019 LTSC Entry EPKEA
Interface USB (3 ports, REV2.0, Front 2, Back 1), 10/100/1000M Ethernet, HDMI
Power Supply 100 VAC to 120 VAC/200 VAC to 240 VAC, 50 Hz to 60 Hz, ≤300 VA
Dimensions and Mass 320 (W) × 177 (H) × 451 (D) mm, ≤10 kg
Environmental
Temperature +10°C to +35°C (operating), –10°C to +50°C (storage)
Humidity <85% RH
Vibration Conforms to MIL-STD-810D
Compliance
CE EMC 2014/30/EU, EN61326-1, EN61000-3-2
CE LVD 2014/35/EU, EN61010-1
CE RoHS 2011/65/EU, (EU) 2015/863, EN IEC 63000: 2018
UKCA EMC S.I. 2016 No.1091, EN 61326-1, EN61000-3-2
UKCA LVD S.I. 2016 No.1101, EN 61010-1
UKCA RoHS S.I. 2012 No.3032, EN IEC 63000: 2018
Laser Safety Level IEC 60825-1: 2014 CLASS 1: Optical Output Port, Monitor Port; 21CFR1040.10
Excludes deviations caused by conformance to Laser Notice No.56 dated May 8, 2019

Applications

  • Submarine optical network installation and maintenance
  • Fault location in ultra-long optical submarine cables
  • Evaluation of new submarine cables at service deployment
  • Troubleshooting in-service submarine cable faults
  • DWDM submarine cable measurement
  • In-service wet plant monitoring with Ciena PinPoint application

Included

  • Power Cord (1 pc)
  • B0329G Front Cover (1 pc)
  • Z2167A MW90010B Operation Manual (CD-R) (1 pc)

Options & Accessories

Option Description
MW90010B-037 FC Connector — Standard connector (required option); the same connector type is supplied for the optical output, input and monitor ports
MW90010B-040 SC Connector — Standard connector (required option); the same connector type is supplied for the optical output, input and monitor ports
MW90010B-003 Extended Measurement Distance — Software option extending the distance range to 100 km, 500 km to 20,000 km (in 500 km steps)
MW90010B-ES210 2 Years Extended Warranty Service
MW90010B-ES310 3 Years Extended Warranty Service
MW90010B-ES510 5 Years Extended Warranty Service
B0335C Carrying Case
J0617B Replaceable Optical Connector (FC-PC)
J0619B Replaceable Optical Connector (SC)
J0057 Optical Adapter FC type
J0635 Optical Fiber Cord with FC-PC at both ends — SM, with FC-PC at both ends; specify length A: 1 m, B: 2 m, C: 3 m
Z0914A Ferrule Cleaner — Cannot be exported to EU Member States
Z0915A Replacement Reel for Ferrule Cleaner (6 pcs/set) — Cannot be exported to EU Member States
Z0284 Adapter Cleaner (Stick type, 200 pcs/set) — Cannot be exported to EU Member States
Z0397A FC Adapter Cap — Monitor Output Port optical connector cap
Z0413A SC Adapter Cap — Monitor Output Port optical connector cap

Documents & Resources