µOTDR Module MU909014C Handheld OTDR Module for Network Master MT9090A
Anritsu MU909014C µOTDR module for the Network Master MT9090A, a pocket-size OTDR for fiber installation and maintenance.
- Wavelength
- 1310/1550/1625/1650 nm SM
- Resolution
- 2 cm
- Deadzone
- less than 1 meter (3-feet)
- Dynamic range
- up to 38 dB
Overview
The MU909014C is a member of the Anritsu µOTDR Module series MU909014C/14C6/15C/15C6. Fitted to the Network Master MT9090A mainframe, it forms a handheld optical time domain reflectometer intended for both installation and maintenance of optical fiber networks.
According to Anritsu, the series offers 2 cm resolution for mapping events, deadzones of less than 1 meter (3 feet) and a dynamic range of up to 38 dB, which is sufficient for testing links over 150 km (90 miles) or PON-based FTTx networks with splits up to 1 x 64.
The instrument is compact and lightweight, at approximately 700 g, and is sized to fit in the palm of the hand. An integrated launch fiber allows measurement of the initial connector without external devices, and the Fiber Visualizer mode provides simplified operation for users without OTDR experience.
Key Features
- Built-in PON Power Meter, Loss Test Set and Light Source functions
- High-end OTDR performance in a pocket-size package
- Integrated launch fiber for initial connector measurement without external devices
- Mid-range performance optimized for typical field links
- Fiber Visualizer mode simplifies operation without OTDR knowledge
- Bluetooth, Wi-Fi and Ethernet connectivity
- PON testing through splitters up to 1 x 64
- High resolution and short deadzones for short fiber evaluation
- Rugged, sealed design for challenging environments
- High resolution widescreen color display readable indoors or outdoors
- Modular platform based on the Network Master MT9090A mainframe
- Compact and lightweight design for field portability
Specifications
| Wavelength |
1310/1550/1625/1650 nm SM
Series listing summary for MU909014C/14C6/15C/15C6; wavelength set varies by model
|
|---|---|
| Resolution |
2 cm
Series overview claim
|
| Deadzone |
less than 1 meter (3-feet)
Series overview claim
|
| Dynamic range |
up to 38 dB
Series overview claim; maximum across the series
|
| PON testing | up to 1 x 64 split |
| Weight | 700 gm approx. |
|---|
Applications
- Optical fiber installation
- Optical fiber maintenance
- PON-based FTTx network testing
- Short fiber evaluation
- Optical fiber testing in manufacturing environments