Anritsu Spectrum Master MS276xA ultraportable spectrum analyzer
Anritsu / MS2760A / Handheld
MS2762A-0145

Spectrum Master MS2762A-0145 Ultraportable Spectrum Analyzer, 6 GHz to 145 GHz

USB-powered ultraportable spectrum analyzer covering 6 GHz to 145 GHz with a 0.8 mm test port, controlled from a Windows PC, laptop or tablet.

Frequency Range
6 GHz to 145 GHz
Tuning Resolution
1 Hz
Internal 10 MHz Frequency Reference Accuracy
±0.2 ppm (25 °C ± 25 °C) + aging
Internal 10 MHz Frequency Reference Aging
±1.0 ppm/year
Datasheet

Overview

The Spectrum Master MS2762A-0145 is a member of the Anritsu MS276xA family of ultraportable spectrum analyzers. It covers 6 GHz to 145 GHz and connects through a 0.8 mm (m) test port. The MS2762A models offer more dynamic range and better DANL performance than the MS2760A models. They are aimed at applications that need high sensitivity.

The analyzer uses Anritsu's patented nonlinear transmission line (NLTL) technology, which is also used in Anritsu vector network analyzers. The instrument is pocket-sized, so it can connect directly to the device under test. This avoids long test port cables, which add loss at millimeter-wave frequencies.

Operation

The MS2762A-0145 is powered over USB and controlled from a Windows-based PC, laptop or tablet. It can be used in the lab, on the manufacturing floor or in the field. Built-in measurements include channel power, adjacent channel power and occupied bandwidth. Spectrum and spectrogram displays are available. An external 10 MHz frequency reference input and an external TTL trigger input are provided.

Applications

Typical uses include automotive radar, 5G and 802.11ad/WiGig development, satellite communications and wireless backhaul. It is also used for radio astronomy, antenna beam pattern testing and on-wafer spectrum measurements together with a vector network analyzer.

Key Features

  • Continuous frequency coverage from 6 GHz to 145 GHz
  • Patented NLTL technology
  • Dynamic range > 108 dB typical at 70 GHz
  • -129 dBm DANL typical to 145 GHz
  • 0.8 mm (m) test port connector
  • Ultraportable form factor enables measurements right at the device under test
  • USB-powered and controlled from a Windows-based PC, laptop, or tablet
  • Measure: channel power, adjacent channel power, occupied bandwidth
  • Spectrum and spectrogram displays
  • Resolution bandwidth 1 Hz to 3 MHz
  • Up to 6 traces, 3 trace detectors, and 12 markers
  • External 10 MHz frequency reference input
  • External TTL trigger input

Specifications

Frequency
Frequency Range
MS2762A-0145
6 GHz to 145 GHz
Tuning Resolution 1 Hz
Internal 10 MHz Frequency Reference Accuracy ±0.2 ppm (25 °C ± 25 °C) + aging
Internal 10 MHz Frequency Reference Aging ±1.0 ppm/year
Frequency Span 10 Hz to maximum frequency range of instrument
Bandwidth
Resolution Bandwidth (RBW) 1 Hz to 3 MHz
Span ≥10 Hz; Zero Span 5 kHz to 20 MHz
Video Bandwidth (VBW) 1 Hz to 3 MHz
Span ≥10 Hz; Zero Span 5 kHz to 20 MHz
VBW/Average Type Linear / Log
RBW Filters Flat Top, Nuttall
Shape Factor <5:1
typical
Amplitude Ranges
Dynamic Range > 108 dB
typical at 70 GHz, 2/3 (TOI – DANL) in 1 Hz RBW
Display Range 1 dB to 15 dB/div in 1 dB steps, ten divisions displayed
Measurement Range DANL to 0 dBm
Reference Level Range –120 dBm to +30 dBm
Amplitude Units dBm
Maximum Safe Level Input +18 dBm CW, ±10 VDC
Amplitude Accuracy
≥ 6 GHz to 40 GHz ±1.8 dB max, ±0.5 dB typical (20 °C to 30 °C); ±3.0 dB max, ±1.0 dB typical (0 °C to 50 °C)
-10 dBm CW signal; 30 minute warm-up (20 °C to 30 °C), 60 minute warm-up (0 °C to 50 °C)
> 40 GHz to 70 GHz ±2.0 dB max, ±0.5 dB typical (20 °C to 30 °C); ±3.0 dB max, ±1.0 dB typical (0 °C to 50 °C)
-10 dBm CW signal
> 70 GHz to 90 GHz ±2.2 dB max, ±0.5 dB typical (20 °C to 30 °C); ±3.0 dB max, ±1.0 dB typical (0 °C to 50 °C)
-10 dBm CW signal
> 90 GHz to 110 GHz ±2.5 dB max, ±0.5 dB typical (20 °C to 30 °C); ±3.0 dB max, ±1.0 dB typical (0 °C to 50 °C)
-10 dBm CW signal
> 110 GHz to 145 GHz ±3.5 dB max, ±0.5 dB typical (20 °C to 30 °C); ±4.0 dB max, ±1.5 dB typical (0 °C to 50 °C)
-10 dBm CW signal
Displayed Average Noise Level (DANL)
> 6 GHz to 40 GHz –135 dBm max, –142 dBm typical
RMS detection, VBW/Avg type = Log, IF Gain On, 1 Hz RBW
> 40 GHz to 70 GHz –137 dBm max, –141 dBm typical
RMS detection, VBW/Avg type = Log, IF Gain On, 1 Hz RBW
> 70 GHz to 90 GHz –136 dBm max, –141 dBm typical
RMS detection, VBW/Avg type = Log, IF Gain On, 1 Hz RBW
> 90 GHz to 110 GHz –132 dBm max, –136 dBm typical
RMS detection, VBW/Avg type = Log, IF Gain On, 1 Hz RBW
> 110 GHz to 145 GHz –119 dBm max, –129 dBm typical
RMS detection, VBW/Avg type = Log, IF Gain On, 1 Hz RBW
Distortion and Spurs
Third-Order Intercept (TOI) at 18 GHz +22 dBm
IF Gain Off, typical, -10 dBm tones 1 MHz apart, –10 dBm reference level
Third-Order Intercept (TOI) at 62 GHz +21 dBm
IF Gain Off, typical, -10 dBm tones 1 MHz apart, –10 dBm reference level
Second Harmonic Distortion –50 dBc maximum
–25 dBm input at 7 GHz
Residual Spurs, 6 GHz to 70 GHz –85 dBm max, –95 dBm typical
Residual Spurs, > 70 GHz to 90 GHz –84 dBm max, –95 dBm typical
Residual Spurs, > 90 GHz to 110 GHz –81 dBm max, –95 dBm typical
Residual Spurs, > 110 GHz to 145 GHz –68 dBm max, –85 dBm typical
Input-related Spurious <–60 dBc
–20 dBm CW input; no image rejection is applied in zero span
SSB Phase Noise (dBc/Hz, 20 °C to 30 °C)
1 kHz offset 7 GHz: –80 max, –89 typ; 30 GHz: –66 max, –74 typ; 60 GHz: –60 max, –69 typ
10 kHz offset 7 GHz: –93 max, –97 typ; 30 GHz: –81 max, –88 typ; 60 GHz: –75 max, –84 typ
100 kHz offset 7 GHz: –94 max, –98 typ; 30 GHz: –81 max, –88 typ; 60 GHz: –75 max, –84 typ
Input Match (typical, 0.8 mm Connector)
6 GHz to 12.4 GHz VSWR 1.92:1, Return Loss 10 dB
> 12.4 GHz to 50 GHz VSWR 1.78:1, Return Loss 11 dB
> 50 GHz to 70 GHz VSWR 2.32:1, Return Loss 8 dB
> 70 GHz to 110 GHz VSWR 3.01:1, Return Loss 6 dB
> 110 GHz to 145 GHz VSWR 4.42:1, Return Loss 4 dB
External Trigger
Source External, Free Run, Video, Periodic (0 s to 5 s)
Delay 0 ms to 1670 ms; –60 s (up to sweep time) in zero span and video or external trigger
Holdoff 0 ms to 5000 ms
Slope Rising, Falling, Both
Hysteresis 0 dB to 200 dB
Sweep, Trace and Marker Functions
Smart Measurements Channel Power, Occupied Bandwidth, Adjacent Channel Power
Zero Span Sweep Time 0.02 ms to 60 s
Sweep (Trace) Points Settable range from 10 to 10,001 points; the default is 501 points
Sweep Time Accuracy ± 2% in Zero Span
Traces Up to six traces
Detector Type per Trace Peak, RMS / Avg, Negative
Markers Up to 12 Markers
Spectrogram Trace Time Cursor Up to six Time Cursors to recall historical trace data by trace number or time
Connectors and Interfaces
RF In
MS2762A-0145
0.8 mm Connector, (0.8mm), male 50Ω
145 GHz and 170 GHz Instruments
USB Interface USB 3.0, Type C Connector
External Reference In MCX(f), 50Ω, 10 MHz
External Trigger In MCX(f), 50Ω, TTL Levels
Computer Requirement
Display Resolution 16:9 / 16:10 Aspect Ratio (>1280 x 720 / 1280 x 800)
Operating System Windows® 7, 8.1, 10; 64-bit
Recommended Minimum Configuration Quad Core i7 fourth generation or higher CPU, 16 GB RAM, 128 GB Data Storage, USB 3.0
Environmental
Environmental Standard MIL-PRF-28800F Class 3
not including Windows Tablet/Laptop/PC
Operating Temperature Range 0 ºC to 50 ºC
Storage Temperature Range –40 ºC to 71 ºC
Maximum Relative Humidity 95 % RH at 30 ºC, non-condensing
Vibration, Sinusoidal 5 Hz to 55 Hz
Vibration, Random 10 Hz to 500 Hz
Half Sine Shock 30 g
Altitude 4600 meters, operating and non-operating
General
Size 155 mm x 84 mm x 27 mm (6.1 in x 3.3 in x 1.1 in)
not including Windows Tablet/Laptop/PC
Weight 255 g (9.0 oz)
not including Windows Tablet/Laptop/PC
Warranty Standard one-year warranty
Technical data sheet value; the product web page states a standard three-year warranty
Calibration Cycle Recommended calibration cycle is 12 months
Safety EN 61010-1:2010

Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.

Applications

  • Automotive radar testing
  • Satellite communications
  • Radio astronomy
  • Wireless backhaul
  • Antenna beam pattern testing
  • 5G and mmWave device development
  • 802.11ad/WiGig spectral mask testing
  • On-wafer spectrum measurements
  • Electronic warfare and radar
  • RF component and device characterization on the production line

Included

  • USB 3.0 Type C to Type A Cable, 1 m (2000-1859-R)
  • BNC(m) to MCX(m) Cable, qty 2 (2000-1605-R)
  • Certificate of Calibration and Conformance

Options & Accessories

Option Description
MS2762A-0145-0097 Accredited Calibration to ISO17025 and ANSI/NCSL Z540-1 — Includes calibration certificate, test report, and uncertainty data
MS2762A-0145-0098 Standard Calibration to ISO17025 and ANSI/NCSL Z540-1 — Includes calibration certificate
MS2762A-0145-0099 Premium Calibration to ISO17025 and ANSI/NCSL Z540-1 — Includes calibration certificate, test report, and uncertainty data
33.8.850 Calibration Grade Adapter, 0.8 mm (m) to 0.8 mm (m) — DC to 145 GHz, 50Ω
33.8.8F50 Calibration Grade Adapter, 0.8 mm (m) to 0.8 mm (f) — DC to 145 GHz, 50Ω
33.8F.8F50 Calibration Grade Adapter, 0.8 mm (f) to 0.8 mm (f) — DC to 145 GHz, 50Ω
33W.850 Calibration Grade Adapter, W1(m) to 0.8 mm (m) — DC to 110 GHz, 50Ω
33W.8F50 Calibration Grade Adapter, W1(m) to 0.8 mm (f) — DC to 110 GHz, 50Ω
33WF.850 Calibration Grade Adapter, W1(f) to 0.8 mm (m) — DC to 110 GHz, 50Ω
33WF.8F50 Calibration Grade Adapter, W1(f) to 0.8 mm (f) — DC to 110 GHz, 50Ω
SM7060 Waveguide to Coaxial End Launch Adapter, WR6 to 0.8 mm(f) — 110 GHz to 145 GHz
3670.850-1 Test Port Cable, Armored, Semi-rigid, 0.8 mm(m) to 0.8 mm(f) 10 cm
3670.850-2 Test Port Cable, Armored, Semi-rigid, 0.8 mm(m) to 0.8 mm(f) 16 cm
01-524 Torque Wrench, 0.45 N·m (4 lbf·in) for 0.8 mm connectors
2000-1888-R USB 3.0 Powered Extension Cable, 10 m, (32 ft) — Up to two can be used in series for a total length of 20 m
2000-1918-R 4-port 200 m USB Multimode Fiber Extender System

Documents & Resources

Spectrum Master Ultraportable Spectrum Analyzer MS276xA Product Brochure
brochure
Spectrum Master MS2760A Ultraportable mmWave Spectrum Analyzer Quick Fact Sheet
brochure · PDF
Spectrum Master MS2762A Ultraportable mmWave Spectrum Analyzer Quick Fact Sheet
brochure
Antennas and Antenna Kits
datasheet · PDF
Spectrum Master MS276xA Technical Data Sheet
datasheet · PDF
Low Noise Amplifiers Technical Data Sheet
datasheet · PDF
USB Extender Technical Data Sheet
datasheet · PDF
USB 3.0 Extension Cable 2000-1888-R Technical Data Sheet
datasheet · PDF
Ultraportable Spectrum Analyzer Declaration of Conformity
other · PDF
IoT, Medical & Healthcare Device Wireless Communication Quality Improvement
app note
Spectrum Monitoring with Field Master Pro Series Spectrum Analyzers
app note
Combining On-Wafer Vector Network Analyzer and Spectrum Analyzer Measurements to 110 GHz Application Note
app note
Automotive Radar Testing with Anritsu’s Spectrum Master MS2760A Ultraportable Spectrum Analyzer
app note
Millimeter Wave Measurement Solutions
brochure
Automotive Testing & Verification Solutions
brochure
Spectrum Master Ultraportable Spectrum Analyzer Product Flyer
brochure
Signal Analyzers and Spectrum Analyzers Selection Guide
brochure
Electronic Measuring Instruments Digest 2026 Catalog
brochure
Precision RF & Microwave Components Catalog
brochure
Automotive Test Solutions
brochure
Spectrum Master MS276xA User Guide
manual
Spectrum Master MS276xA Help
manual
Spectrum Master MS2760A Maintenance Manual
manual