Spectrum Master MS2762A-0050 Ultraportable Spectrum Analyzer, 6 GHz to 50 GHz
USB-powered ultraportable spectrum analyzer covering 6 GHz to 50 GHz with a V (1.85 mm) male test port, controlled from a Windows PC.
- Frequency Range
- 6 GHz to 50 GHz
- Tuning Resolution
- 1 Hz
- Internal 10 MHz Frequency Reference – Aging
- ±1.0 ppm/year
- Internal 10 MHz Frequency Reference – Accuracy
- ±0.2 ppm (25 °C ± 25 °C) + aging
Overview
The Spectrum Master MS2762A-0050 is a member of the Anritsu Spectrum Master MS276xA family of ultraportable spectrum analyzers. It covers 6 GHz to 50 GHz and has a V (1.85 mm) male test port connector, which is compatible with 2.4 mm connectors.
The MS2762A models are intended for applications with demanding sensitivity requirements. Compared with the MS2760A models they offer higher dynamic range and better displayed average noise level (DANL) performance, with frequency coverage starting at 6 GHz. The family is based on Anritsu's patented nonlinear transmission line (NLTL) technology.
The instrument is pocket-sized, so it can connect directly to the device under test without long test port cables, which add loss at millimeter-wave frequencies. For over-the-air measurements, a waveguide horn antenna can be attached directly to the test port.
The analyzer is powered over USB and controlled from a Windows-based PC, laptop or tablet. This makes it usable in the lab, on the manufacturing floor and in the field. Built-in measurements include channel power, adjacent channel power and occupied bandwidth, with spectrum and spectrogram displays.
Key Features
- Frequency coverage from 6 GHz to 50 GHz
- V (1.85 mm) male test port connector, compatible with 2.4 mm
- Ultraportable form factor enables measurements right at the device under test
- USB-powered and controlled from a Windows-based PC, laptop, or tablet
- Measure: channel power, adjacent channel power, occupied bandwidth
- Spectrum and spectrogram displays
- Up to 6 traces, 3 trace detectors, and 12 markers
- Resolution bandwidth (RBW) from 1 Hz to 3 MHz
- External 10 MHz frequency reference input
- External TTL trigger input
- Compatible with the 2000-1929-R 18 GHz to 42 GHz low noise amplifier
Specifications
| Frequency Range | 6 GHz to 50 GHz |
|---|---|
| Tuning Resolution | 1 Hz |
| Internal 10 MHz Frequency Reference – Aging | ±1.0 ppm/year |
| Internal 10 MHz Frequency Reference – Accuracy | ±0.2 ppm (25 °C ± 25 °C) + aging |
| Frequency Span | 10 Hz to maximum frequency range of instrument |
| Resolution Bandwidth (RBW) |
1 Hz to 3 MHz
Span ≥10 Hz; Zero Span 5 kHz to 20 MHz
|
|---|---|
| Video Bandwidth (VBW) |
1 Hz to 3 MHz
Span ≥10 Hz; Zero Span 5 kHz to 20 MHz
|
| VBW/Average Type | Linear / Log |
| RBW Filters | Flat Top, Nuttall |
| Shape Factor | <5:1 typical |
| Display Range | 1 dB to 15 dB/div in 1 dB steps, ten divisions displayed |
|---|---|
| Measurement Range | DANL to 0 dBm |
| Reference Level Range | –120 dBm to +30 dBm |
| Amplitude Units | dBm |
| Maximum Safe Level Input | +18 dBm CW, ±10 VDC |
| ≥ 6 GHz to 40 GHz (20 °C to 30 °C) |
±1.8 dB maximum, ±0.5 dB typical
-10 dBm CW signal, after 30 minute warm-up
|
|---|---|
| > 40 GHz to 70 GHz (20 °C to 30 °C) |
±2.0 dB maximum, ±0.5 dB typical
-10 dBm CW signal, after 30 minute warm-up; this model covers up to 50 GHz
|
| ≥ 6 GHz to 40 GHz (0 °C to 50 °C) |
±3.0 dB maximum, ±1.0 dB typical
-10 dBm CW signal, after 60 minute warm-up
|
| > 40 GHz to 70 GHz (0 °C to 50 °C) |
±3.0 dB maximum, ±1.0 dB typical
-10 dBm CW signal, after 60 minute warm-up; this model covers up to 50 GHz
|
| > 6 GHz to 40 GHz |
–135 dBm maximum, –142 dBm typical
RMS detection, VBW/Avg type = Log, IF Gain On, 1 Hz RBW
|
|---|---|
| > 40 GHz to 70 GHz |
–137 dBm maximum, –141 dBm typical
RMS detection, VBW/Avg type = Log, IF Gain On, 1 Hz RBW; this model covers up to 50 GHz
|
| 1 kHz offset |
–80 dBc/Hz maximum, –89 dBc/Hz typical (7 GHz); –66 dBc/Hz maximum, –74 dBc/Hz typical (30 GHz)
20 °C to 30 °C
|
|---|---|
| 10 kHz offset |
–93 dBc/Hz maximum, –97 dBc/Hz typical (7 GHz); –81 dBc/Hz maximum, –88 dBc/Hz typical (30 GHz)
20 °C to 30 °C
|
| 100 kHz offset |
–94 dBc/Hz maximum, –98 dBc/Hz typical (7 GHz); –81 dBc/Hz maximum, –88 dBc/Hz typical (30 GHz)
20 °C to 30 °C
|
| Residual Spurs, 6 GHz to 70 GHz |
–85 dBm maximum, –95 dBm typical
This model covers up to 50 GHz
|
|---|---|
| Input-related Spurious |
<–60 dBc
–20 dBm CW input
|
| Zero Span | No image rejection is applied to the sweep while in zero span, therefore spurious impact may be different. |
| Third-Order Intercept (TOI), 18 GHz |
+22 dBm
IF Gain Off, typical, -10 dBm tones 1 MHz apart, –10 dBm reference level
|
| Second Harmonic Distortion, –25 dBm Input |
–50 dBc maximum
At 7 GHz input
|
| 6 GHz to 12.4 GHz | VSWR 1.92:1, Return Loss 10 dB |
|---|---|
| > 12.4 GHz to 50 GHz | VSWR 1.78:1, Return Loss 11 dB |
| Source | External, Free Run, Video, Periodic (0 s to 5 s) |
|---|---|
| Delay | 0 ms to 1670 ms; –60 s (up to sweep time) in zero span and video or external trigger |
| Holdoff | 0 ms to 5000 ms |
| Slope | Rising, Falling, Both |
| Hysteresis | 0 dB to 200 dB |
| Smart Measurements | Channel Power, Occupied Bandwidth, Adjacent Channel Power |
|---|---|
| Zero Span Sweep Time | 0.02 ms to 60 s |
| Sweep (Trace) Points | Settable range from 10 to 10,001 points; the default is 501 points |
| Minimum Capture Time | 0 s to 10 s |
| Sweep Time Accuracy | ± 2% in Zero Span |
| Traces | Up to six traces |
| Trace Type | Clear / Write, Trace Average, Max Hold, Min Hold, Rolling Average, Rolling Max Hold, Rolling Min Hold |
| Detector Type per Trace | Peak, RMS / Avg, Negative |
| Spectrogram Trace Time Cursor | Up to six Time Cursors to recall historical trace data by trace number or time |
| Markers | Up to 12 Markers |
| Marker Mode | Normal, Delta, Fixed |
| Limit Line Envelope | Create Envelope, Update Envelope, Points (41 max), Offset, Shape Square/Slope |
| RF In |
V Connector (1.85 mm), male 50Ω
50 GHz and 70 GHz instruments; compatible with 2.4 mm connectors
|
|---|---|
| USB Interface | USB 3.0, Type C Connector |
| External Reference In | MCX(f), 50Ω, 10 MHz |
| External Trigger In | MCX(f), 50Ω, TTL Levels |
| Display Resolution | 16:9 / 16:10 Aspect Ratio (>1280 x 720 / 1280 x 800) |
|---|---|
| Operating System | Windows® 7, 8.1, 10; 64-bit |
| Recommended Minimum Configuration | Quad Core i7 fourth generation or higher CPU, 16 GB RAM, 128 GB Data Storage, USB 3.0 |
| Environmental Standard |
MIL-PRF-28800F Class 3
Not including Windows Tablet/Laptop/PC
|
|---|---|
| Operating Temperature Range | 0 ºC to 50 ºC |
| Storage Temperature Range | –40 ºC to 71 ºC |
| Maximum Relative Humidity | 95 % RH at 30 ºC, non-condensing |
| Vibration, Sinusoidal | 5 Hz to 55 Hz |
| Vibration, Random | 10 Hz to 500 Hz |
| Half Sine Shock | 30 g |
| Altitude | 4600 meters, operating and non-operating |
| Explosive Atmosphere | MIL-PRF-28800F Section 4.5.6.3, MIL-STD-810G, Method 511.5, Procedure 1 |
| European Union EMC |
2014/30/EU, EN 61326:2013, CISPR 11/EN 55011, IEC/EN 61000-4-2/3/4/5/6/8/11
Not including Windows Tablet/Laptop/PC
|
|---|---|
| Low Voltage Directive | 2014/35/EU |
| Safety | EN 61010-1:2010 |
| RoHS Directive | 2011/65/EU applies to instruments with CE marking placed on the market after July 22, 2017 |
| Australia and New Zealand | RCM AS/NZS 4417:2012 |
| South Korea | KCC-R-R-A2J-1015 |
| Canada | ICES-1(A)/NMB-1(A) |
| Size |
155 mm x 84 mm x 27 mm (6.1 in x 3.3 in x 1.1 in)
Not including Windows Tablet/Laptop/PC
|
|---|---|
| Weight |
255 g (9.0 oz)
Not including Windows Tablet/Laptop/PC
|
| Calibration Cycle | Recommended calibration cycle is 12 months. |
|---|---|
| Warranty |
Standard one-year warranty
The product web page lists a standard three-year warranty; the technical data sheet states one year
|
Specifications are taken from the manufacturer's documentation. See the datasheet for complete and current values.
Applications
- 5G and mmWave device development
- Automotive radar testing
- Satellite communications
- Wireless backhaul
- 802.11ad/WiGig spectral mask testing
- Radio astronomy
- Antenna beam pattern testing
- On-wafer spectrum measurements
- RF component and device characterization on the production line
- Microwave radio link testing
- Electronic warfare and radar
Included
- 2000-1859-R USB 3.0 Type C to Type A Cable, 1 m
- 2000-1605-R BNC(m) to MCX(m) Cable (qty 2)
- Certificate of Calibration and Conformance
Options & Accessories
| Option | Description |
|---|---|
| MS2762A-0050-0097 | Accredited Calibration to ISO17025 and ANSI/NCSL Z540-1 — Includes calibration certificate, test report, and uncertainty data |
| MS2762A-0050-0098 | Standard Calibration to ISO17025 and ANSI/NCSL Z540-1 — Includes calibration certificate |
| MS2762A-0050-0099 | Premium Calibration to ISO17025 and ANSI/NCSL Z540-1 — Includes calibration certificate, test report, and uncertainty data |
| 2000-1929-R | Low Noise Amplifier, 18 GHz to 42 GHz, 28 dB Gain, V(m) to V(f) — Fits models MS276xA-0050 and MS276xA-0070; Noise Figure 4 dB; Max RF input level -5 dBm (0 dBm damage level) |
| 2000-1933-R | USB power bank (for use with the MS276xA Low Noise Amplifier accessory) |
| 34VFK50A | Coaxial Adapter, DC to 43.5 GHz, V(f) to K(m), 50Ω |
| 34VFKF50A | Coaxial Adapter, DC to 43.5 GHz, V(f) to K(f), 50Ω |
| 34VV50 | Coaxial Adapter, DC to 65 GHz, V(m) to V(m), 50Ω |
| 34VVF50 | Coaxial Adapter, DC to 65 GHz, V(f) to V(m), 50Ω |
| 34VFVF50 | Coaxial Adapter, DC to 65 GHz, V(f) to V(f), 50Ω |
| 2000-1880-R | Coaxial Adapter, V (f) to N (m), DC to 18 GHz, 50 Ω |
| 2000-1881-R | Coaxial Adapter, V (f) to N (f), DC to 18 GHz, 50 Ω |
| 1091-456-R | Adapter, 49.9 to 67.0 GHz, WR15 to V(f) |
| 1091-457-R | Adapter, 39.3 to 59.7 GHz, WR19 to V(f) |
| 1091-458-R | Adapter, 33.0 to 50.1 GHz, WR22 to V(f) |
| 1091-459-R | Adapter, 26.4 to 40.1 GHz, WR28 to V(f) |
| 35WR22VF | Precision Waveguide Coaxial Adapter, 33 GHz to 50 GHz, WR22 to V(f) |
| 35WR19VF | Precision Waveguide Coaxial Adapter, 40 GHz to 60 GHz, WR19 to V(f) |
| 41VA-3 | Fixed Attenuator, Precision, DC to 70 GHz, 1W, 3 dB, V(m) to V(f) |
| 41VA-6 | Fixed Attenuator, Precision, DC to 70 GHz, 1W, 6 dB, V(m) to V(f) |
| 41VA-10 | Fixed Attenuator, Precision, DC to 70 GHz, 1W, 10 dB, V(m) to V(f) |
| 41VA-20 | Fixed Attenuator, Precision, DC to 70 GHz, 1W, 20 dB, V(m) to V(f) |
| 41VA-30 | Fixed Attenuator, Precision, DC to 70 GHz, 1W, 30 dB, V(m) to V(f) |
| 41VA-40 | Fixed Attenuator, Precision, DC to 70 GHz, 1W, 40 dB, V(m) to V(f) |
| 3670V50A-1 | Test Port Cable, DC to 70 GHz, V(f) to V(m), 30.5 cm (1 ft) |
| 3670V50A-2 | Test Port Cable, DC to 70 GHz, V(f) to V(m), 61.0 cm (2 ft) |
| 2000-1867-R | Directional Horn Antenna, 17.6 GHz to 26.7 GHz, WR42, 25 dBi gain |
| 2000-1868-R | Directional Horn Antenna, 26.4 GHz to 40.1 GHz, WR28, 25 dBi gain |
| 2000-1869-R | Directional Horn Antenna, 33.0 GHz to 50.1 GHz, WR22, 25 dBi gain |
| 2000-1870-R | Directional Horn Antenna, 39.3 GHz to 59.7 GHz, WR19, 25 dBi gain |
| 01-201 | Torque Wrench, 0.9 N·m (8 lbf·in) for K, V, SMA, 3.5 mm, 2.4 mm connectors |
| 2000-1888-R | USB 3.0 Powered Extension Cable, 10 m, (32 ft) — Up to two can be used in series for a total length of 20 m |
| 2000-1918-R | 4-port 200 m USB Multimode Fiber Extender System |